Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Deuteron irradiation of W and WO 3 for production of high specific activity 186 Re: Challenges associated with thick target preparation

This investigation evaluated target fabrication and beam parameters for scale-up production of high specific activity 186 Re using deuteron irradiation of enriched 186 W via the 186 W(d,2n) 186 Re reaction. Thick W and WO 3 targets were prepared, characterized and evaluated in deuteron irradiations. Full-thickness targets, as determined using SRIM, were prepared by uniaxi-ally pressing powdered natural abundance W and WO 3 , or 96.86% enriched 186 W, into Al target supports. Alternatively, thick targets were prepared by pressing 186 W between two layers of graphite powder or by placing pre-sintered (1105°C, 12 hours) natural abundance WO 3 pellets into an Al target support. Assessments of structural integrity were made on each target pre-pared. Prior to irradiation, material composition analyses were conducted using SEM, XRD, and Raman spectroscopy. With-in a minimum of 24 hours post irradiation, gamma-ray spectroscopy was performed on all targets to assess production yields and radionuclidic byproducts. Problems were encountered with the structural integrity of some pressed W and WO 3 pellets before and during irradiation, and target material characterization results could be correlated with the structural integrity of the pressed target pellets. Under the conditions studied, the findings suggest that all WO 3 targets prepared and studied were unacceptable. By contrast, 186W metal was found to be a viable target material for 186 Re production. Lastly, thick targets prepared with powdered 186W pressed between layers of graphite provided a particularly robust target configuration.

43 PARTICLE ACCELERATORS↗

A TEST OF THICK-TARGET NONUNIFORM IONIZATION AS AN EXPLANATION FOR BREAKS IN SOLAR FLARE HARD X-RAY SPECTRA

Solar nonthermal hard X-ray (HXR) flare spectra often cannot be fitted by a single power law, but rather require a downward break in the photon spectrum. A possible explanation for this spectral break is nonuniform ionization in the emission region. We have developed a computer code to calculate the photon spectrum from electrons with a power-law distribution injected into a thick target in which the ionization decreases linearly from 100% to zero. We use the bremsstrahlung cross section from Haug, which closely approximates the full relativistic Bethe-Heitler cross section, and compare photon spectra computed from this model with those obtained by Kontar et al., who used a step-function ionization model and the Kramers approximation to the cross section. We find that for HXR spectra from a target with nonuniform ionization, the difference (DELTAgamma) between the power-law indexes above and below the break has an upper limit between approx0.2 and 0.7 that depends on the power-law index delta of the injected electron distribution. A broken power-law spectrum with a higher value of DELTAgamma cannot result from nonuniform ionization alone. The model is applied to spectra obtained around the peak times of 20 flares observed by the Ramaty High-Energy Solar Spectroscopic Imager from 2002 to 2004 to determine whether thick-target nonuniform ionization can explain the measured spectral breaks. A Monte Carlo method is used to determine the uncertainties of the best-fit parameters, especially on DELTAgamma. We find that 15 of the 20 flare spectra require a downward spectral break and that at least six of these could not be explained by nonuniform ionization alone because they had values of DELTAgamma with less than a 2.5% probability of being consistent with the computed upper limits from the model. The remaining nine flare spectra, based on this criterion, are consistent with the nonuniform ionization model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Prototype Thick-Target Bremsstrahlung Model with Angularly-Dependent Emission in the MCNP6 ® Code

This document summarizes the current thick-target bremsstrahlung (TTB) model in MCNP and provides test results for an alternative implementation to improve the accuracy with reduced cost compared to full electron transport. It has been observed that the current TTB model produces inaccurate results in problems where the medium is thick with respect to electrons, but the photon distribution in the problem has a strong directionality. An example of such a simulation is detectors surrounding a metal target irradiated with a radiographic beam of high energy photons. The primary cause of this discrepancy is the current TTB method emits all bremsstrahlung photons in the same direction as the primary electron produced from each (γ, e ± ) interaction, leading to artificially forward peaked photon distributions for intermediate to high-energy incident photons. To improve the TTB model, we have implemented an angularly-dependent TTB model in a developer version of the MCNP6 ® code; for developers, this was done on the branch prototype/angular_ttb in the mcnp6 repo on bitbucket. The angularly-dependent TTB model accounts for the energy and scattering of electrons as they slow down in the current material, but does not sample the computationally expensive energy straggling, secondary electron events, and tracking electrons; this approach is significantly less computationally expensive than full electron transport and can be comparable to the original TTB method for problems with sufficiently complex materials and geometry. To evaluate the method, we have modeled a simple problem of a beam of 5 MeV photons incident on a sphere of plutonium surrounded by detectors at different deflection angles. For this problem, the angularly-dependent TTB produces a photon flux within 8.0% for a 90 degree deflection angle and 0.8% along the beam axis, as compared to the electron transport solution. This is an improvement compared to a 43% and 81% discrepancy with the original TTB method, respectively. The rest of this work includes the following: the first section details the current TTB treatment in MCNP, which has not been well documented elsewhere. Then, the modified TTB algorithm is detailed and the approximations compared to the condensed history algorithm are compared. Results are given comparing the two TTB methods to the condensed history transport algorithm. The appendix includes details for code developers on relevant electron transport implementation details and potential code improvements for future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGH-RESOLUTION IMAGING OF SOLAR FLARE RIBBONS AND ITS IMPLICATION ON THE THICK-TARGET BEAM MODEL

We report on high-resolution optical and hard X-ray observations of solar flare ribbons seen during the GOES X6.5 class white-light flare of 2006 December 6. The data consist of imaging observations at 430 nm (the Fraunhofer G band) taken by the Hinode Solar Optical Telescope with the hard X-rays observed by the Reuven Ramaty High Energy Solar Spectroscopic Imager. The two sets of data show closely similar ribbon structures, strongly suggesting that the flare emissions in white light and in hard X-rays have physically linked emission mechanisms. While the source structure along the ribbons is resolved at both wavelengths (length {approx} 30''), only the G-band observations resolve the width of the ribbon, with values between {approx}0.''5 and {approx}1.''8. The unresolved hard X-ray observations reveal an even narrower ribbon in hard X-rays (the main footpoint has a width perpendicular to the ribbon of <1.''1 compared to the G-band width of {approx}1.''8) suggesting that the hard X-ray emission comes from the sharp leading edge of the G-band ribbon. Applying the thick-target beam model, the derived energy deposition rate is >5 x 10{sup 12} erg s{sup -1} cm{sup -2} provided by an electron flux of 1 x 10{sup 20} electrons s{sup -1} cm{sup -2} above 18 keV. This requires that the beam density of electrons above 18 keV be at least 1 x 10{sup 10} cm{sup -3}. Even if field lines converge toward the chromospheric footpoints, the required beam in the corona has too high a density to be described as a dilute tail population on top of a Maxwellian core. We discuss this issue and others associated with this extreme event, which poses serious questions to the standard thick target beam interpretation of solar flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Thick target measurement of the 40Ca(alpha,gamma)44Ti reaction rate

The thick-target yield for the {sup 40}Ca({alpha},{gamma}){sup 44}Ti reaction has been measured for E{sub beam} = 4.13, 4.54, and 5.36 MeV using both an activation measurement and online {gamma}-ray spectroscopy. The results of the two measurements agree. From the measured yield a reaction rate is deduced that is smaller than statistical model calculations. This implies a smaller {sup 44}Ti production in supernova compared to recently measured {sup 40}Ca({alpha},{gamma}){sup 44}Ti reaction rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tri-stage quasimonoenergetic proton acceleration from a multi-species thick target

We show that quasimonoenergetic proton beams can be generated through a multi-ion thick target irradiated by a circularly polarized laser pulse. After disrupted by the transverse instabilities in the laser pressure acceleration process, heavy ions as majority species can still provide a co-moving electric field. Different from the dynamics using ultrathin foil, protons with small doped rates can experience a full tri-stage quasimonoenergetic acceleration (hole boring, sheath boosting, and free expansion stages) in this scenario. A theoretical model is developed to explain the proton energy evolution in detail and verified by two-dimensional particle-in-cell simulations. Finally, the scaling of proton energy with laser intensity indicates that the 200 MeV proton beam with narrow energy spread (3%–10%) and sufficiently large charges (10 10 –10 11 ) required for medical applications can be obtained using 100s TW class laser systems in near future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies

Several Monte Carlo systems were benchmarked against published measurements of bremsstrahlung yield from thick targets for 10-30 MV beams. The quantity measured was photon fluence at 1 m per unit energy per incident electron (spectra), and total photon fluence, integrated over energy, per incident electron (photon yield). Results were reported at 10-30 MV on the beam axis for Al and Pb targets and at 15 MV at angles out to 90 degree sign for Be, Al, and Pb targets. Beam energy was revised with improved accuracy of 0.5% using an improved energy calibration of the accelerator. Recently released versions of the Monte Carlo systems EGSNRC, GEANT4, and PENELOPE were benchmarked against the published measurements using the revised beam energies. Monte Carlo simulation was capable of calculation of photon yield in the experimental geometry to 5% out to 30 degree sign , 10% at wider angles, and photon spectra to 10% at intermediate photon energies, 15% at lower energies. Accuracy of measured photon yield from 0 to 30 degree sign was 5%, 1 s.d., increasing to 7% for the larger angles. EGSNRC and PENELOPE results were within 2 s.d. of the measured photon yield at all beam energies and angles, GEANT4 within 3 s.d. Photon yield at nonzero angles for angles covering conventional field sizes used in radiotherapy (out to 10 degree sign ), measured with an accuracy of 3%, was calculated within 1 s.d. of measurement for EGSNRC, 2 s.d. for PENELOPE and GEANT4. Calculated spectra closely matched measurement at photon energies over 5 MeV. Photon spectra near 5 MeV were underestimated by as much as 10% by all three codes. The photon spectra below 2-3 MeV for the Be and Al targets and small angles were overestimated by up to 15% when using EGSNRC and PENELOPE, 20% with GEANT4. EGSNRC results with the NIST option for the bremsstrahlung cross section were preferred over the alternative cross section available in EGSNRC and over EGS4. GEANT4 results calculated with the ''low energy'' physics list were more accurate than those calculated with the ''standard'' physics list.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 13}N+p elastic resonance scattering via a thick-target method

The {sup 13}N+p elastic resonance scattering has been studied in inverse kinematics via a thick-target method. A {sup 13}N secondary beam of 47.8{+-}1.5 MeV produced by the {sup 2}H({sup 12}C,{sup 13}N)n reaction was used to bombard a 9.33 mg/cm{sup 2} (CH{sub 2}){sub n} target. The recoil protons were detected by a {delta}E-E silicon counter telescope at {theta}{sub lab}=15 deg. The performance of the setup was checked by {sup 12}C+p elastic resonance scattering with the same (CH{sub 2}){sub n} target. The excitation function for the {sup 13}N(p,p) elastic scattering was obtained in the energy interval of E{sub c.m.}{approx}0.5-3.2 MeV and was analyzed by using a multilevel R-matrix code MULTI7. Several low-lying excited states in {sup 14}O were surveyed. Our results confirm a very recent 2{sup -} assignment to the 6.8 MeV level and agree with the observation of a new 0{sup -} level at 5.7 MeV with a width of 400(45) keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of target thickness on the generation of high-density ion bunches by ultrashort circularly polarized laser pulses

Ion acceleration by ultrashort circularly polarized laser pulse in a solid-density target is investigated using two-dimensional particle-in-cell simulation. The ions are accelerated and compressed by the continuously extending space-charge field created by the evacuation and compression of the target electrons by the laser light pressure. For a sufficiently thin target, the accelerated and compressed ions can reach and exit from the rear surface as a high-density high-energy ion bunch. The peak ion energy depends on the target thickness and reaches maximum when the compressed ion layer can just reach the rear target surface. The compressed ion layer exhibits lateral striation which can be suppressed by using a sharp-rising laser pulse.

43 PARTICLE ACCELERATORS↗

Secondary neutron yields from thick-target GCR accelerator experiments - 25434

This work overviews recent experiments conducted at the NASA Space Radiation Laboratory which sought to experimentally verify model predictions of an optimal spacecraft shielding thickness and provide data which can be used to quantify uncertainties in the physics models within the standard particle transport codes which presently, in some places, poorly predict data and whose results can vary significantly from code to code. Now that the multi-year experiment campaign is complete, some of the overarching trends in the data can be studied; though this work only provides a cursory look at these overarching trends. A small set of the neutron yields measured in these experiments are showcased here. The experiment employed two thick targets along a beamline to emulate the walls of a spacecraft being bombarded by galactic cosmic rays. Time-of-flight techniques were used to characterize neutrons produced in the upstream target while a novel pulse height deconvolution methodology was developed and implemented to characterize neutrons produced in the downstream target. (authors)

43 PARTICLE ACCELERATORS↗

CORONAL THICK TARGET HARD X-RAY EMISSIONS AND RADIO EMISSIONS

A distinctive class of hard X-ray (HXR) sources located in the corona was recently found, which implies that the collisionally thick target model (CTTM) applies even to the corona. We investigated whether this idea can be independently verified by microwave radiations which have been known as the best companion to HXRs. This study is conducted on the GOES M2.3 class flare which occurred on 2002 September 9 and was observed by the Reuven Ramaty High-Energy Solar Spectroscopic Imager and the Owens Valley Solar Array. Interpreting the observed energy-dependent variation of HXR source size under the CTTM, the coronal density should be as high as 5 Multiplication-Sign 10{sup 11} cm{sup -3} over a distance of up to 12''. To explain the cutoff feature of the microwave spectrum at 3 GHz, however, we require a density no higher than 1 Multiplication-Sign 10{sup 11} cm{sup -3}. Additional constraints must be placed on the temperature and magnetic field of the coronal source in order to reproduce the microwave spectrum as a whole. First, a spectral feature called the Razin suppression requires a magnetic field in a range of 250-350 G along with high viewing angles around 75 Degree-Sign . Second, to avoid excess fluxes at high frequencies due to the free-free emission that was not observed, we need a high temperature {>=}2 Multiplication-Sign 10{sup 7} K. These two microwave spectral features, Razin suppression and free-free emissions, become more significant at regions of high thermal plasma density and are essential for validating and determining additional parameters of the coronal HXR sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Picosecond lifetime measurements of resonances using a thick-target invariant-mass technique

Here, a new technique is presented for measuring the half-lives of resonances in the picosecond range using presently available invariant-mass apparatus and a thick target. For short-lived resonances, the energy losses of the decay fragments in the target material change their relative velocities giving rise to a poor invariant-mass resolution. However, for longer-lived resonances that travel through the remaining target material before decaying outside of the target, this dominant contribution to the resolution is eliminated. The measured invariant-mass peak will then display a narrow peak from these events which sits on a wider structure associated with the remaining events that decay in the target. The fraction of the events in the narrow peak is related to the probability that the resonance leaves the target before decaying and hence is related to the lifetime. This technique is exercised for the 2.685-MeV resonance in 33 Cl which decays by emitting an f -wave proton. A half-life of T 1/2 =5.7$^{+4.1}_{-2.5}$ ps was measured which is consistent with values inferred from other known properties of this resonance.

lifetimes & widths↗

Determination of the mean energy of fast electron losses and anisotropies through thick-target emission on WEST

Abstract A new method to obtain the mean energy of fast electron losses in fusion plasmas using a versatile multi-energy hard x-ray (HXR) detector is presented. The method is based on measuring the thick-target emission of tungsten in the divertor region produced by fast electron losses interacting with the target and modeling the tungsten spectra by a Monte Carlo code which simulates the interaction between a beam of electrons and a solid target. The mean energy of the fast electron losses is determined through the comparison between the experimental and synthetic emission. The results show that fast electron losses during lower hybrid current drive discharges at WEST have a mean energy of 90–140 keV and represent only 2% of the total heat flux at the target. Additionally, anisotropic HXR emission has been detected for the first time at the WEST core and edge plasma, with opposite directions. It is due to the forward-peak emission of two distinctive populations of fast electrons: co-current fast electrons in the core and counter-current fast electron losses at the inner strike point. In view of future experiments like ITER where electron cyclotron current drive will generate a fast electron population, this technique could serve as a real-time monitor of fast electron losses and eventually feed an actuator on the current drive generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular distribution of thick-target bremsstrahlung produced by electrons with initial energies ranging from 10 to 20 keV incident on Ag

Experimental results are presented comparing the intensities of the bremsstrahlung produced by electrons with initial energies ranging from 10 to 20 keV incident on a thick Ag target, measured at forward angles in the range of 0 degree sign to 55 degree sign . When the data are corrected for attenuation due to photon absorption within the target, the results indicate that the detected radiation is distributed anisotropically only at photon energies k that are approximately equal to the initial energy of the incident electrons E{sub 0}. The results of our experiments suggest that, as k/E{sub 0}{yields} 0, the detected radiation essentially becomes isotropic due primarily to the scattering of electrons within the target. A comparison to the theory of Kissel et al.[At. Data Nucl. Data Tables 28, 381 (1983)] suggests that the angular distribution of bremsstrahlung emitted by electrons incident on thick targets is similar to the angular distribution of bremsstrahlung emitted by electrons incident on free-atom targets only when k/E{sub 0}{approx_equal} 1. The experimental data also are in approximate agreement with the angular distribution predictions of the Monte Carlo program penelope.

74 ATOMIC AND MOLECULAR PHYSICS↗

Searching for states analogous to the C 12 Hoyle state in heavier nuclei using the thick target inverse kinematics technique

Identification of α-cluster states analogous to the C 12 Hoyle state in heavier α-conjugate nuclei can provide tests of the existence of α condensates in nuclei. Such states are predicted for O 16 , Ne 20 , Mg 24 , Si 28 , etc., at excitation energies slightly above the multi- α-particle decay threshold but have not yet been experimentally identified. The thick target inverse kinematics (TTIK) technique can be used to study the breakup of excited self-conjugate nuclei into many α particles. The reaction Ne 20 + α was studied using a Ne 20 beam at 12 MeV/nucleon from the K150 cyclotron at Texas A&M University. The TTIK method was used to study both single α-particle emission and multiple α-particle decays. Events with α multiplicity up to four were analyzed. The analysis of the three α-particle emission data allowed the identification of the Hoyle state and other C 12 excited states decaying into three α particles. The results are shown and compared with other data available in the literature. Although the statistics for events with α-multiplicity four is low, the data show a structure at about 15.2 MeV that could indicate the existence in O 16 of a state analogous to the C 12 Hoyle state. Moreover, the reconstructed excitation energy of Mg 24 for these events peaks at around 34 MeV, very close to the predicted excitation energy for an excited state analogous to the C 12 Hoyle state in Mg 24 . The structure is further confirmed by the reanalysis of α-multiplicity-four events from a previous experiment performed at 9.7 MeV/nucleon with a similar, but lower granularity, experimental setup.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of N 15 + α resonant structures in F 19 using the thick target in inverse kinematics scattering method

The spectroscopy of F 19 is of interest for nuclear astrophysics and nuclear structure. In astrophysics, fluorine and the reactions producing and destroying it play a key role in constraining models of stars in different evolutionary stages, such as the asymptotic giant branch (AGB) stars, responsible of the production of about half of the elements heavier than Fe. In nuclear structure, F 19 has been subject to many investigations aiming at the identification of α and more exotic cluster structures. Also, its spectroscopy is very useful to constrain the nuclear properties of the 19 Ne mirror nucleus. Here in this work, we report on the measurement of the 15 N α elastic scattering using the thick target inverse kinematics approach, allowing us to span a very large fluorine excitation energy range (~6-10 MeV). The use of 15 N α scattering proves very useful to study α clustering in F 19 thanks to the likelihood for populating states with such a structure. Indeed, the R-matrix analysis of the measured differential cross sections shows the occurrence of many candidate α-cluster states of F 19 . It also calls for the redefinition of the spin-parity and widths of a number of F 19 states with respect to what reported in the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thick target neutron yields from Beryllium, Carbon, Tungsten, and Lead targets irradiated by 26.7 MeV/nucleon 4 H e ions

The angular and energy distributions of secondary neutrons produced from 26.7 MeV/nucleon 4 He ions, stopping in thick Be, C, W and Pb targets are measured by the time of flight method. The GEANT4, PHITS, and FLUKA Monte Carlo simulation codes with different physics models are employed to simulate the neutron yields and the results are compared with the experimental data. For the thick Be and C targets, GEANT4 with INCL++ reproduces the experimental data reasonably well. Whereas PHITS with JQMD-2.0 overestimates the neutron yields at intermediate energies and FLUKA with PEANUT underestimated the neutron yields at intermediate energies. For W and Pb targets, FLUKA with PEANUT physics model agree with experimental data best. PHITS with JQMD-2.0 overestimates the neutron yield at intermediate energies at 0°, and GEANT4 with INCL++ underestimates the neutron yield at intermediate energies at three angles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmission Nuclear Resonance Fluorescence Measurements of 238U in Thick Targets

Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86 g/cm2. The 238U content n the targets varied from 0 to 8.5percent (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to he average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter 238U measurements indicates general agreement in observed excited states. Two new 238U excited states and possibly a third state have also been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗