3-D Modeling of the CFR Engine for the Investigation of Knock on Natural Gas

Abstract: Engine knock and misfire are barriers to pathways leading to higher efficiency natural gas (NG) engines, where the general tendency to knock is highly dependent on engine operating conditions and the fuel reactivity. The problem is further complicated by low emissions limits and the wide range of chemical reactivity in pipeline quality NG, making the understanding of fuel- engine interactions essential to achieving high efficiencies in spark-ignited NG engines. The present work highlights a three-dimensional computational fluid dynamics (CFD) model of the Cooperative Fuel Research (CFR) engine to investigate knock behavior when running on NG. Using a Converge CFD model of the CFR engine fuel-engine interactions that lead to knock with NG, including effects of fuel reactivity, engine operating parameters, and exhaust gas recirculation, are being investigated. A GT-Power model is used to estimate appropriate initial conditions in the Converge CFD model, including cylinder wall, piston, valves, and port surface temperatures as well as residual gas fraction. In order to validate the model, in-cylinder pressure data taken with a CFR engine is compared to model predictions while varying compression ratio, CA50, and BMEP.

CFR Engine, Converge CFD, knock, Natural Gas↗

Thermal Evaluations for Hypothetically Drain-Down Spent Fuel Storage Facility at SRS

The L-Area Spent Nuclear Fuel (SNF) underwater storage facility at Savannah River Site (SRS), referred to as L-Basin SNF facility, has an array of Vertical Tube Storage (VTS) racks and a group of High Flux Irradiation Reactor (HFIR) fuel cores. The underwater facility is integrally designed as a wet SNF storage system with a chemically-controlled water pool. The SNF storage racks are seismically qualified. The L-Basin pool holds about 3.4 million gallons of water with concrete wall thickness of about 5 ft and water depths of 17 ft to 30 ft. The facility has mainly two different elevation levels of 30 ft and 17 ft below the ground level. At the level 30 ft below the ground, a maximum of 110 racks of VTS and 5 racks of Dry Cave can be stored. At the level of 17 ft below the ground, 120 HFIR cores can be stored, considering that each rack contains two HFIR cores. In case of a hypothetical accident, all cooling water in the storage pool may be drained away, resulting in dry SNF storage condition. The primary objective of the work is to estimate the maximum fuel temperature in a conservative manner when the L-Basin facility is completely dry due to the hypothetical drain-down of the pool water. A three-dimensional Computational Fluid Dynamics (CFD) modeling approach was taken for the thermal evaluations of the water-drained SNF storage facility. The modeling calculations were performed, assuming that all of the storage racks in L-Basin are fully loaded with SNF assemblies containing decay heat sources. In the case of full loading, the L-Basin facility stores 14,600 SNF assemblies in VTS racks and 120 cores in HFIR racks. The thermal analysis results of the L-Basin model yielded maximum temperatures of VTS and HFIR fuel assemblies for different fuel loading scenarios and boundary conditions of the SNF storage racks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Hydrogasification Process for Co-Production of Substitute Natural Gas (SNG) and Electric Power from Western Coals

This report presents the results of the research and development conducted on an Advanced Hydrogasification Process (AHP) conceived and developed by Arizona Public Service Company (APS) under U.S. Department of Energy (DOE) contract: DE-FC26-06NT42759 for Substitute Natural Gas (SNG) production from western coal. A double-wall (i.e., a hydrogasification contained within a pressure shell) down-flow hydrogasification reactor was designed, engineered, constructed, commissioned and operated by APS, Phoenix, AZ. The reactor is ASME-certified under Section VIII with a rating of 1150 pounds per square inch gage (psig) maximum allowable working pressure at 1950 degrees Fahrenheit (°F). The reaction zone had a 1.75 inch inner diameter and 13 feet length. The initial testing of a sub-bituminous coal demonstrated ~ 50% carbon conversion and ~10% methane yield in the product gas under 1625°F, 1000 psig pressure, with a 11 seconds (s) residence time, and 0.4 hydrogen-to-coal mass ratio. Liquid by-products mainly contained Benzene, Toluene, Xylene (BTX) and tar. Char collected from the bottom of the reactor had 9000-British thermal units per pound (Btu/lb) heating value. A three-dimensional (3D) computational fluid dynamic model simulation of the hydrodynamics around the reactor head was utilized to design the nozzles for injecting the hydrogen into the gasifier to optimize gas-solid mixing to achieve improved carbon conversion. The report also presents the evaluation of using algae for carbon dioxide (CO 2 ) management and biofuel production. Nannochloropsis, Selenastrum and Scenedesmus were determined to be the best algae strains for the project purpose and were studied in an outdoor system which included a 6-meter (6M) radius cultivator with a total surface area of 113 square meters (m 2 ) and a total culture volume between 10,000 to 15,000 liters (L); a CO 2 on-demand feeding system; an on-line data collection system for temperature, pH, Photosynthetically Activate Radiation (PAR) and dissolved oxygen (DO); and a ~2 gallons per minute (gpm) algae culture dewatering system. Among the three algae strains, Scenedesmus showed the most tolerance to temperature and irradiance conditions in Phoenix and the best self-settling characteristics. Experimental findings and operational strategies determined through these tests guided the operation of the algae cultivation system for the scale-up study. Effect of power plant flue gas, especially heavy metals, on algae growth and biomass adsorption were evaluated as well.

01 COAL, LIGNITE, AND PEAT↗

Temperature Rise on Liner Surfaces of Fuel Cell Electric Vehicle Tanks during Fueling Process

Herein, the temperature of the inner tank walls, or plastic liners, of composite pressure tanks in fuel cell electric vehicles during fueling using three‐dimensional computational fluid dynamics (CFD) models is evaluated. The liner materials are limited to 85.0 °C to prevent thermal stress causing material failure that would result in a hydrogen leak. Therefore, the temperature of hydrogen gas must be limited to below 85.0 °C during the fueling process as dictated by the current fueling protocol. However, there are limited experimental or simulation data confirming that the temperature changes do not exceed the threshold. Herein, the liner temperatures with CFD tank models for two sizes of type IV tanks representative of the upper and lower system bounds that are close to the SAE J2601 fueling protocol (36.0 and 244.0 L) are evaluated. First, each model's reliability is validated with experimental data and then analyzed, and the data are used to evaluate the maximum hydrogen and liner temperatures under real‐world fueling conditions. The evaluation shows that the maximum liner surface temperature of each tank model is at least 7 °C lower than that of the hydrogen. Additionally, there is at least 12 °C difference found between the upper limit and actual liner temperatures.

33 ADVANCED PROPULSION SYSTEMS↗

Simulation of an Industrial Tangentially Fired Boiler Firing Metallurgical Gases

In industrial environments, boiler units are widely used to supply heat and electrical power. At an integrated steel mill, industrial boilers combust a variable mixture of metallurgical gases combined with additional fuels to generate high-pressure superheated steam. Most tangentially fired boilers have experienced water wall tube failures in the combustion zone, which are thought to be caused by some deficiency in the combustion process. The challenge faced in this present process is that there are very limited means to observe the boiler operation. In our study, a three-dimensional computational fluid dynamics (CFD) modeling and simulation of an industrial tangentially fired boiler firing metallurgical gases was conducted. Eddy dissipation combustion model was applied on this multiple fuel combustion process. Simulation results obtained from the developed CFD model were validated by industrial experiments. Furthermore, a quick comparison of the flame shape from the simulation to the actual flame in the boiler showed a good agreement. We also analyzed the flow field and temperature distribution inside the tangentially fired boiler under the operation conditions, and a wall water tube overheating problem was observed and directly related to the flow

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric Study of Panel PCM–Air Heat Exchanger Designs

Heat exchangers, devices for the transfer of heat between two or more working fluids, are extensively used in cooling applications and heating applications. Heat exchangers in buildings are typically components of space-conditioning systems, as well as of water-heating applications. Heat exchangers are also sometimes used in applications that require storage and release of energy at specific times. Phase change materials (PCMs) enhance these heat-exchange processes, given their ability to melt and solidify at a fixed range of temperatures, absorbing or releasing significant amounts of latent heat. Five different configurations of PCM–air heat exchangers for thermal control in buildings are analyzed in this work. The heat exchangers were fitted with PCM encapsulated in plastic and composite pouches of various shapes, and packaged in stackable panel layers. Three-dimensional computational fluid dynamics (CFD) modeling of coupled incompressible fluid and conjugate heat transfer were performed on the designs. The phase change process was numerically modelled using the apparent heat capacity method. Steady-state CFD simulations provided quantification of pressure drop as a function of air flow velocity. Transient simulation results describe the thermal evolution of PCM in the pouches, helping to determine the best performing configuration with respect to total thermal charging time.

10 SYNTHETIC FUELS↗

3D CFD ELECTROCHEMICAL AND HEAT TRANSFER MODEL OF AN INTERNALLY MANIFOLDED SOLID OXIDE ELECTROLYSIS CELL

A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to model high-temperature electrolysis cell performance and steam electrolysis in an internally manifolded planar solid oxide electrolysis cell (SOEC) stack. This design is being evaluated at the Idaho National Laboratory for hydrogen production from nuclear power and process heat. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user-defined subroutine was modified for this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, operating potential, steam-electrode gas composition, oxygen-electrode gas composition, current density and hydrogen production over a range of stack operating conditions. Single-cell and five-cell results will be presented. Flow distribution through both models is discussed. Flow enters from the bottom, distributes through the inlet plenum, flows across the cells, gathers in the outlet plenum and flows downward making an upside-down ''U'' shaped flow pattern. Flow and concentration variations exist downstream of the inlet holes. Predicted mean outlet hydrogen and steam concentrations vary linearly with current density, as expected. Effects of variations in operating temperature, gas flow rate, oxygen-electrode and steam-electrode current density, and contact resistance from the base case are presented. Contour plots of local electrolyte temperature, current density, and Nernst potential indicate the effects of heat transfer, reaction cooling/heating, and change in local gas composition. Results are discussed for using this design in the electrolysis mode. Discussion of thermal neutral voltage, enthalpy of reaction, hydrogen production, cell thermal efficiency, cell electrical efficiency, and Gibbs free energy are discussed and reported herein.

08 HYDROGEN↗

3-D CFD MODEL OF A MULTI-CELL HIGH TEMPERATURE ELECTROLYSIS STACK

A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to model high-temperature electrolysis stack performance and steam electrolysis in the Idaho National Laboratory (INL) Integrated Lab Scale (ILS) experiment. The model is made of 60 planar cells stacked on top of each other operated as Solid Oxide Electrolysis Cells (SOEC). Details of the model geometry are specific to a stack that was fabricated by Ceramatec, Inc. and tested at INL. Inlet and outlet plenum flow and distribution are considered. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user defined subroutine was modified for this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, Nernst potential, operating potential, activation over-potential, anode-side gas composition, cathode-side gas composition, current density, and hydrogen production over a range of stack operating conditions. Variations in flow distribution and species concentration are discussed. End effects of flow and per-cell voltage are also considered.

08 HYDROGEN↗

3D CFD Electrochemical and Heat Transfer Model of an Integrated-Planar Solid Oxide Electrolysis Cells

A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to assess hightemperature electrolysis performance of an Integrated Planar porous-tube-supported Solid Oxide Electrolysis Cell (IPSOEC). The model includes ten integrated planar cells in a segmented-in-series geometry deposited on a flattened ceramic support tube. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) module adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user-defined subroutine was modified for this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, Nernst potential, operating potential, activation over-potential, anode-side gas composition, cathode-side gas composition, current density and hydrogen production over a range of stack operating conditions. Predicted mean outlet hydrogen and steam concentrations vary linearly with current density, as expected. Contour plots of local electrolyte temperature, current density, and Nernst potential indicated the effects of heat transfer, endothermic reaction, Ohmic heating, and change in local gas composition. Results are discussed for using this design in the electrolysis mode. Discussion of thermal neutral voltage, enthalpy of reaction, hydrogen production is reported herein. Predictions show negative pressure in the H2 electrode, indicating a possible limit of H2O diffusion through the ceramic tube. Minimum temperatures occur in the fuel and air downstream corner of the ceramic tube for voltages below the thermal neutral point.

Source record↗

3D CFD Electrochemical and Heat Transfer Model of an Integrated-Planar Solid Oxide Electrolysis Cells

A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to model high-temperature electrolysis cell performance and steam electrolysis in a new novel integrated planar porous-tube supported solid oxide electrolysis cell (SOEC). The model is of several integrated planar cells attached to a ceramic support tube. This design is being evaluated with modeling at the Idaho National Laboratory. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user-defined subroutine was modified for this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, Nernst potential, operating potential, activation over-potential, anode-side gas composition, cathode-side gas composition, current density and hydrogen production over a range of stack operating conditions. Mean per-cell area-specific-resistance (ASR) values decrease with increasing current density. Predicted mean outlet hydrogen and steam concentrations vary linearly with current density, as expected. Effects of variations in operating temperature, gas flow rate, cathode and anode exchange current density, and contact resistance from the base case are presented. Contour plots of local electrolyte temperature, current density, and Nernst potential indicated the effects of heat transfer, reaction cooling/heating, and change in local gas composition. Results are discussed for using this design in the electrolysis mode. Discussion of thermal neutral voltage, enthalpy of reaction, hydrogen production, cell thermal efficiency, cell electrical efficiency, and Gibbs free energy are discussed and reported herein.

08 HYDROGEN↗

Transient Heat and Material Flow Modeling of Friction Stir Processing of Magnesium Alloy using Threaded Tool

A three-dimensional transient computational fluid dynamics (CFD) model was developed to investigate the material flow and heat transfer during friction stir processing (FSP) in an AZ31B magnesium alloy. The material was assumed to be a non-Newtonian viscoplastic fluid, and the Zener-Hollomon parameter was used to describe the dependence of material viscosity on temperature and strain rate. The material constants used in the constitutive equation were determined experimentally from compression tests of the AZ31B Mg alloy under a wide range of strain rates and temperatures. A dynamic mesh method, combining both Lagrangian and Eulerian formulations, was used to capture the material flow induced by the movement of the threaded tool pin. Massless inert particles were embedded in the simulation domain to track the detailed history of material flow. The actual FSP was also carried out on a wrought Mg plate where temperature profiles were recorded by embedding thermocouples. The predicted transient temperature history was found to be consistent with that measured during FSP. Finally, the influence of the thread on the simulated results of thermal history and material flow was studied by comparing two models: one with threaded pin and the other with smooth pin surface.

36 MATERIALS SCIENCE↗

Resolving Anodic Current and Temperature Distributions in a Polymer Electrolyte Membrane Water Electrolysis Cell Using a Pseudo-Two-Phase Computational Fluid Dynamics Model

Expanding upon our prior experimental work, we constructed a three-dimensional model of a polymer electrolyte membrane water electrolyzer using computational fluid dynamics. We applied the assumption of pseudo-two-phase flow, the flow of two phases with equal velocity. Experimental data were used to obtain parameters and to determine the conditions under which this model was valid. Anodic distributions of current density, temperature, liquid saturation, and relative humidity were obtained at various flow rates. The overall current density and temperature difference from inlet to outlet at the anode agreed strongly with experimental measurements under most circumstances. This verification allowed us to further examine the apparent gas coverage calculated from experimental and model temperature data. Results suggested a low liquid saturation and low relative humidity at the anode due to the consumption of liquid water and water vapor. However, we questioned the accuracy of the pseudo-two-phase assumption at low water feed rates. We concluded that the model was applicable to systems with liquid water feed rates greater than 0.6 ml min -1 cm -2 . Therefore, it is a fair screening method that can advise which operating conditions lead to excessive temperatures or drying at the anode, thereby promoting the longevity of the membrane and catalyst.

25 ENERGY STORAGE↗

Forest structural complexity and ignition pattern influence simulated prescribed fire effects

Background: Forest structural characteristics, the burning environment, and the choice of ignition pattern each influence prescribed fire behaviors and resulting fire effects; however, few studies examine the influences and interactions of these factors. Understanding how interactions among these drivers can influence prescribed fire behavior and effects is crucial for executing prescribed fires that can safely and effectively meet management objectives. To analyze the interactions between the fuels complex and ignition patterns, we used FIRETEC, a three-dimensional computational fluid dynamics fire behavior model, to simulate fire behavior and effects across a range of horizontal and vertical forest structural complexities. For each forest structure, we then simulated three different prescribed fires each with a unique ignition pattern: strip-head, dot, and alternating dot. Results: Forest structural complexity and ignition pattern affected the proportions of simulated crown scorch, consumption, and damage for prescribed fires in a dry, fire-prone ecosystem. Prescribed fires in forests with complex canopy structures resulted in increased crown consumption, scorch, and damage compared to less spatially complex forests. The choice of using a strip-head ignition pattern over either a dot or alternating-dot pattern increased the degree of crown foliage scorched and damaged, though did not affect the proportion of crown consumed. We found no evidence of an interaction between forest structural complexity and ignition pattern on canopy fuel consumption, scorch, or damage. Conclusions: We found that forest structure and ignition pattern, two powerful drivers of fire behavior that forest managers can readily account for or even manipulate, can be leveraged to influence fire behavior and the resultant fire effects of prescribed fire. These simulation findings have critical implications for how managers can plan and perform forest thinning and prescribed burn treatments to meet risk management or ecological objectives.

54 ENVIRONMENTAL SCIENCES↗

A Study of Propane Combustion in a Spark-Ignited Cooperative Fuel Research (CFR) Engine

Liquefied petroleum gas (LPG), whose primary composition is propane, is a promising candidate for heavy-duty vehicle applications as a diesel fuel alternative due to its CO 2 reduction potential and high knock resistance. To realize diesel-like efficiencies, spark-ignited LPG engines are proposed to operate near knock-limit over a wide range of operating conditions, which necessitates an investigation of fuel-engine interactions that leads to end-gas autoignition with propane combustion. This work presents both experimental and numerical studies of stoichiometric propane combustion in a sparkignited (SI) cooperative fuel research (CFR) engine. Engine experiments are initially conducted at different compression ratio (CR) values, and the effects of CR on engine combustion are characterized. A three-pressure analysis (TPA) model based on the two-zone combustion concept is developed in GT-Power and validated using test results to estimate in-cylinder wall temperatures, residual gas fraction, etc. This model is further utilized to examine end-gas chemistry by enabling the SI turbulent flame combustion and unburned gas chemical kinetics modules. Finally, a three-dimensional (3D) computational fluid dynamic (CFD) model of the CFR engine is developed in CONVERGE, where the G-equation and SAGE detailed chemical kinetics models are implemented for combustion modeling. Here, a 153 species reduced chemical kinetics mechanism derived from the detailed NUIGMech1.1 mechanism based on the ignition delay and laminar flame speed (LFS) studies is used to generate an LFS lookup table and to describe end-gas autoignition chemistry. Multi-cycle Reynolds-averaged Navier-Stokes (RANS) simulations are then performed for the tested CRs, and the numerical model is shown to be capable of predicting the propane combustion characteristics, particularly the end-gas autoignition behavior.

20 FOSSIL-FUELED POWER PLANTS↗

ROM-Based Surrogate Systems Modeling of EBR-II

We report the System Analysis Module (SAM), developed and maintained by Argonne National Laboratory, is designed to provide whole-plant transient safety analysis capabilities for a number of advanced non-light water reactors, including sodium-cooled fast reactor (SFR), lead-cooled fast reactor (LFR), and molten salt reactor (MSR)/fluoride-salt-cooled high-temperature reactor (FHR) designs. SAM is primarily constructed as a systems-level analysis tool, with the potential to incorporate reduced order models from three-dimensional computational fluid dynamics (CFD) simulations to improve characterization of complex, multidimensional physics. It is recognized that the computational expense associated with CFD can be intractable for various engineering analyses, such as uncertainty quantification, inference, and design optimization. This paper explores the reducibility of a SAM model using recent advances in randomized linear algebra techniques, which attempt to find recurring patterns in the various realizations generated by a model after randomly perturbing all its input parameters. The reduction is described in terms of fewer degrees of freedom (DOFs), referred to as the active DOFs, for the model variables such as input model parameters and model responses. The results indicate that there is significant room for additional reduction that may be leveraged for additional computational gains when employing SAM for engineering-intensive analyses that require repeated model executions. Different from physics-based reduction approaches, the proposed approach allows one to estimate upper bounds on the reduction errors, which are rigorously developed in this work. Finally, different methods for surrogate model construction, such as regression and neural network-based training, are employed to correlate the input and output active DOFs, which are related back to the original variables using matrix-based linear transformations.

42 ENGINEERING↗

Reliability of Lumped Thermodynamic Hydrogen Fueling Model under Slow-Fill Conditions

This study verifies the reliability of lumped thermodynamic fuel cell electric vehicle (FCEV) tank model under considerably slow-fill conditions. Many countries put efforts into research and development of FCEVs. As part of the efforts, thermodynamic hydrogen fueling models have been developed to understand the hydrogen temperature in the onboard tanks of FCEVs during the fueling process. Most of the models treat the hydrogen inside the tanks to be a lumped system and assume the hydrogen temperature to be uniform throughout the tanks. In other words, the hydrogen temperature is treated as average bulk temperature. This study certifies whether treating the hydrogen temperature in a tank as the bulk gas temperature is suitable by evaluating the temperature distributions inside the tank by a three-dimensional computational fluid dynamics (3D CFD) model.

DIRECT ENERGY CONVERSION,HYDROGEN↗

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

THERMAL MODELING ANALYSIS OF SRS 70 TON CASK

The primary objective of this work was to perform the thermal calculations to evaluate the Material Test Reactor (MTR) fuel assembly temperatures inside the SRS 70-Ton Cask loaded with various bundle powers. MTR fuel consists of HFBR, MURR, MIT, and NIST. The MURR fuel was used to develop a bounding case since it is the fuel with the highest heat load. The results will be provided for technical input for the SRS 70 Ton Cask Onsite Safety Assessment. The calculation results show that for the SRS 70 ton dry cask with 2750 watts total heat source with a maximum bundle heat of 670 watts and 9 bundles of MURR bounding fuel, the highest fuel assembly temperatures are below about 263 C. Maximum top surface temperature of the plastic cover is about 112 C, much lower than its melting temperature 260 C. For 12 bundles of MURR bounding fuel with 2750 watts total heat and a maximum fuel bundle of 482 watts, the highest fuel assembly temperatures are bounded by the 9 bundle case. The component temperatures of the cask were calculated by a three-dimensional computational fluid dynamics approach. The modeling calculations were performed by considering daily-averaged solar heat flux.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗