Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Injection of Direct-Sequence Spread Spectrum Pilot Tones into Beamline Components as a Means of Downconverter Stabilization and Real-Time Receiver Calibration

Beamline components used for diagnostic elements often rely on thermal stabilization, continual physical maintenance (ie. tuning), and frequent beam-based calibrations to maintain specified performance. Direct-sequence spread spectrum (DSSS) pilot tones injected into a particular element and combined with the beam-derived signal can subsequently be separated and used to assess performance degradation. In addition, the DSSS tone can be used as a real-time calibration signal, without interference to the intended diagnostic signal. This paper demonstrates such a technique in the design of a Beam Current Monitor downconverter system, as an intended upgrade to the CEBAF Beam Loss Accounting system. A brief spread-spectrum primer is included, as well as a description of appropriate spreading codes and their generation.

Musson, John↗

Injection of Direct-Sequence Spread Spectrum Pilot Tones into Beamline Components as a Means of Downconverter Stabilization and Real-Time Receiver Calibration

Beamline components used for diagnostic elements often rely on thermal stabilization, continual physical maintenance (ie. tuning), and frequent beam-based calibrations to maintain specified performance. Direct-sequence spread spectrum (DSSS) pilot tones injected into a particular element and combined with the beam-derived signal can subsequently be separated and used to assess performance degradation. In addition, the DSSS tone can be used as a real-time calibration signal, without interference to the intended diagnostic signal. This paper demonstrates such a technique in the design of a Beam Current Monitor downconverter system, as an intended upgrade to the CEBAF Beam Loss Accounting system. A brief spread-spectrum primer is included, as well as a description of appropriate spreading codes and their generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operating Experience Review of the INL HTE Gas Monitoring System

This paper describes the operations of several types of gas monitors in use at the Idaho National Laboratory (INL) High Temperature Electrolysis Experiment (HTE) laboratory. The gases monitored at hydrogen, carbon monoxide, carbon dioxide, and oxygen. The operating time, calibration, and unwanted alarms are described. The calibration session time durations are described. Some simple statistics are given for the reliability of these monitors and the results are compared to operating experiences of other types of monitors.

08 HYDROGEN↗

Calibration of time of flight detectors using laser-driven neutron source

Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Hybrid MPI/OpenMP Approach for Parallel Groundwater Model Calibration on Multicore Computers

Groundwater model calibration is becoming increasingly computationally time intensive. We describe a hybrid MPI/OpenMP approach to exploit two levels of parallelism in software and hardware to reduce calibration time on multicore computers with minimal parallelization effort. At first, HydroGeoChem 5.0 (HGC5) is parallelized using OpenMP for a uranium transport model with over a hundred species involving nearly a hundred reactions, and a field scale coupled flow and transport model. In the first application, a single parallelizable loop is identified to consume over 97% of the total computational time. With a few lines of OpenMP compiler directives inserted into the code, the computational time reduces about ten times on a compute node with 16 cores. The performance is further improved by selectively parallelizing a few more loops. For the field scale application, parallelizable loops in 15 of the 174 subroutines in HGC5 are identified to take more than 99% of the execution time. By adding the preconditioned conjugate gradient solver and BICGSTAB, and using a coloring scheme to separate the elements, nodes, and boundary sides, the subroutines for finite element assembly, soil property update, and boundary condition application are parallelized, resulting in a speedup of about 10 on a 16-core compute node. The Levenberg-Marquardt (LM) algorithm is added into HGC5 with the Jacobian calculation and lambda search parallelized using MPI. With this hybrid approach, compute nodes at the number of adjustable parameters (when the forward difference is used for Jacobian approximation), or twice that number (if the center difference is used), are used to reduce the calibration time from days and weeks to a few hours for the two applications. This approach can be extended to global optimization scheme and Monte Carol analysis where thousands of compute nodes can be efficiently utilized.

54 ENVIRONMENTAL SCIENCES↗

Diagnosing ICF gamma-ray physics

Gamma rays produced in an ICF environment open up a host of physics opportunities we are just beginning to explore. A branch of the DT fusion reaction, with a branching ratio on the order of 2e-5 {gamma}/n, produces 16.7 MeV {gamma}-rays. These {gamma}-rays provide a direct measure of fusion reaction rate (unlike x-rays) without being compromised by Doppler spreading (unlike neutrons). Reaction-rate history measurements, such as nuclear bang time and burn width, are fundamental quantities that will be used to optimize ignition on the National Ignition Facility (NIF). Gas Cherenkov Detectors (GCD) that convert fusion {gamma}-rays to UV/visible Cherenkov photons for collection by fast optical recording systems established their usefulness in illuminating ICF physics in several experimental campaigns at OMEGA. Demonstrated absolute timing calibrations allow bang time measurements with accuracy better than 30 ps. System impulse response better than 95 ps fwhm have been made possible by the combination of low temporal dispersion GCDs, ultra-fast microchannel-plate photomultiplier tubes (PMT), and high-bandwidth Mach Zehnder fiber optic data links and digitizers, resulting in burn width measurement accuracy better than 10ps. Inherent variable energy-thresholding capability allows use of GCDs as {gamma}-ray spectrometers to explore other interesting nuclear processes. Recent measurements of the 4.44 MeV {sup 12}C(n,n{prime}) {gamma}-rays produced as 14.1 MeV DT fusion neutrons pass through plastic capsules is paving the way for a new CH ablator areal density measurement. Insertion of various neutron target materials near target chamber center (TCC) producing secondary, neutron-induced {gamma}y-rays are being used to study other nuclear interactions and as in-situ sources to calibrate detector response and DT branching ratio. NIF Gamma Reaction History (GRH) diagnostics, based on the GCD concept, are now being developed based on optimization of sensitivity, bandwidth, dynamic range, cost, and NIF-specific logistics, requirements and extreme radiation environment. Implementation will occur in two phases: (1) four PMT-based channels mounted to the outside of the target chamber at {approx}6m from TCC (GRH-6m) for the 3e13-3e16 DT neutron yield range expected during the early ignition-tuning campaigns; and (2) several channels located just inside the target bay shield wall at 15 m from TCC (GRH-15m) with optical paths leading through the cement shield wall to well-shielded streak cameras and PMTs for the 1e16-1e20 yield range expected during the DT ignition campaign. Multiple channels at each phase will allow for increased redundancy, reliability, accuracy and flexibility. This suite of diagnostics will make possible exploration of interesting {gamma}-ray physics well beyond the ignition campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependency of EBT2 film calibration curve on postirradiation time

Purpose: The Ashland Inc. product EBT2 film model is a widely used quality assurance tool, especially for verification of 2-dimensional dose distributions. In general, the calibration film and the dose measurement film are irradiated, scanned, and calibrated at the same postirradiation time (PIT), 1-2 days after the films are irradiated. However, for a busy clinic or in some special situations, the PIT for the dose measurement film may be different from that of the calibration film. In this case, the measured dose will be incorrect. This paper proposed a film calibration method that includes the effect of PIT. Methods: The dose versus film optical density was fitted to a power function with three parameters. One of these parameters was PIT dependent, while the other two were found to be almost constant with a standard deviation of the mean less than 4%. The PIT-dependent parameter was fitted to another power function of PIT. The EBT2 film model was calibrated using the PDD method with 14 different PITs ranging from 1 h to 2 months. Ten of the fourteen PITs were used for finding the fitting parameters, and the other four were used for testing the model. Results: The verification test shows that the differences between the delivered doses and the film doses calculated with this modeling were mainly within 2% for delivered doses above 60 cGy, and the total uncertainties were generally under 5%. The errors and total uncertainties of film dose calculation were independent of the PIT using the proposed calibration procedure. However, the fitting uncertainty increased with decreasing dose or PIT, but stayed below 1.3% for this study. Conclusions: The EBT2 film dose can be modeled as a function of PIT. For the ease of routine calibration, five PITs were suggested to be used. It is recommended that two PITs be located in the fast developing period (1∼6 h), one in 1 ∼ 2 days, one around a week, and one around a month.

61 RADIATION PROTECTION AND DOSIMETRY↗

A feasibility study to determine cooling time and burnup of ATR fuel using a nondestructive technique and three types of gamma-ray detectors

The goal of this work was to perform a feasibility study and establish measurement techniques to determine the burnup of the Advanced Test Reactor (ATR) fuels at the Idaho National Laboratory (INL). Three different detectors of high purity germanium (HPGe), lanthanum bromide (LaBr{sub 3}), and high pressure xenon (HPXe) in two detection system configurations of below and above the water pool were used in this study. The last two detectors were used for the first time in fuel burnup measurements. The results showed that a better quality spectra can be achieved with the above the water pool configuration. Both short and long cooling time fuels were investigated in order to determine which measurement technique, absolute or fission product ratio, is better suited in each scenario and also to establish what type of detector should be used in each case for the best burnup measurement. The burnup and cooling time calibrations were established using experimental absolute activities or isotopic ratios and ORIGEN burnup calculations. A method was developed to do burnup and cooling time calibrations using fission isotopes activities without the need to know the exact geometry. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computer Model Calibration with Time Series Data Using Deep Learning and Quantile Regression

Computer models play a key role in many scientific and engineering problems. One major source of uncertainty in computer model experiments is input parameter uncertainty. Computer model calibration is a formal statistical procedure to infer input parameters by combining information from model runs and observational data. The existing standard calibration framework suffers from inferential issues when the model output and observational data are high-dimensional dependent data, such as large time series, due to the difficulty in building an emulator and the nonidentifiability between effects from input parameters and data-model discrepancy. To overcome these challenges, we, in this work, propose a new calibration framework based on a deep neural network (DNN) with long short-term memory layers that directly emulates the inverse relationship between the model output and input parameters. Adopting the “learning with noise” idea, we train our DNN model to filter out the effects from data-model discrepancy on input parameter inference. We also formulate a new way to construct interval predictions for DNN using quantile regression to quantify the uncertainty in input parameter estimates. Through a simulation study and real data application with the Weather Research and Forecasting Model Hydrological modeling system (WRF-Hydro), we show our approach can yield accurate point estimates and well-calibrated interval estimates for input parameters.

97 MATHEMATICS AND COMPUTING↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System Calibration Including Time Delay Estimation for GNSS/INS-Assisted Pushbroom Scanners Onboard UAV Platforms

Unmanned aerial vehicles (UAVs ) equipped with imaging sensors and integrated global navigation satellite system/inertial navigation system (GNSS/INS ) units are used for numerous applications. Deriving reliable 3D coordinates from such UAVs is contingent on accurate geometric calibration, which encompasses the estimation of mounting parameters and synchronization errors. Through a rigorous impact analysis of such systematic errors, this article proposes a direct approach for spatial and temporal calibration (estimating system parameters through a bundle adjustment procedure) of a GNSS/INS -assisted pushbroom scanner onboard a UAV platform. The calibration results show that the horizontal and vertical accuracies are within the ground sampling distance of the sensor. Unlike for frame camera systems, this article also shows that the indirect approach is not a feasible solution for pushbroom scanners due to their limited ability for decoupling system parameters. This finding provides further support that the direct approach is recommended for spatial and temporal calibration of UAV pushbroom scanner systems.

47 OTHER INSTRUMENTATION↗

Monte Carlo simulations of time-of-flight PET with double-ended readout: calibration, coincidence resolving times and statistical lower bounds

Here, this paper demonstrates through Monte Carlo simulations that a practical positron emission tomograph with (1) deep scintillators for efficient detection, (2) double-ended readout for depth-of-interaction information, (3) fixed-level analog triggering, and (4) accurate calibration and timing data corrections can achieve a coincidence resolving time (CRT) that is not far above the statistical lower bound. One Monte Carlo algorithm simulates a calibration procedure that uses data from a positron point source. Annihilation events with an interaction near the entrance surface of one scintillator are selected, and data from the two photodetectors on the other scintillator provide depth-dependent timing corrections. Another Monte Carlo algorithm simulates normal operation using these corrections and determines the CRT. A third Monte Carlo algorithm determines the CRT statistical lower bound by generating a series of random interaction depths, and for each interaction a set of random photoelectron times for each of the two photodetectors. The most likely interaction times are determined by shifting the depth-dependent probability density function to maximize the joint likelihood for all the photoelectron times in each set. Example calculations are tabulated for different numbers of photoelectrons and photodetector time jitters for three 3 × 3 × 30 mm 3 scintillators: Lu 2 SiO 5 :Ce,Ca (LSO), LaBr 3 :Ce, and a hypothetical ultra-fast scintillator. To isolate the factors that depend on the scintillator length and the ability to estimate the DOI, CRT values are tabulated for perfect scintillator-photodetectors. For LSO with 4000 photoelectrons and single photoelectron time jitter of the photodetector J = 0.2 ns (FWHM), the CRT value using the statistically weighted average of corrected trigger times is 0.098 ns FWHM and the statistical lower bound is 0.091 ns FWHM. For LaBr 3 :Ce with 8000 photoelectrons and J = 0.2 ns FWHM, the CRT values are 0.070 and 0.063 ns FWHM, respectively. For the ultra-fast scintillator with 1 ns decay time, 4000 photoelectrons, and J = 0.2 ns FWHM, the CRT values are 0.021 and 0.017 ns FWHM, respectively. Lastly, the examples also show that calibration and correction for depth-dependent variations in pulse height and in annihilation and optical photon transit times are necessary to achieve these CRT values.

60 APPLIED LIFE SCIENCES↗

X-Ray Imaging Spectrometer for Recording Calibrated Time-Resolved K-Shell Spectra from Magnetically Confined Fusion Plasmas

Based on transmission crystal spectrometers recently optimized for recording high-resolution K-shell spectra from laser generated plasmas, an imaging spectrometer has been designed to record Mo and W K-shell spectra from magnetically confined plasmas. The spectrometer can be used to diagnose the electron energy distribution and transport of metal ions from the wall and divertor to the core plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Multi-Layer Phoswich Radioxenon Detection System (7th Qtr Report), Reporting Period 10/01/07 - 12/31/07

Description of activities conducted this report period: (1) Electronics Development--To improve the overall performance of the two-channel digital pulse processor (DPP2), the PCB has been redesigned and the new printed board is now under assembly. The system is enhanced with two new fast ADCs from Analog Devices (AD9230-250), each with a sampling rate of 250 MHz and a resolution of 12 bits. The data bus uses a high performance Low Voltage Differential Signaling (LVDS) standard. The offset and gain of each channel are separately controlled digitally by the GUI software. (2) GUI Software Development--A GUI is being developed using the Python programming language. All functions from the preceding MATLAB code have been re-implemented including basic waveform readout, pulse shape discrimination, and plotting of energy spectra. In addition, the GUI can be used to control sampling runs based on the number of pulses captured, either in real or live time. Calibration coefficients and pulse shape discrimination boundaries can be changed on the fly so that the detector may be characterized experimentally. Plots generated by the GUI can be exported as graphic data. At present, the software has only been tested using one channel, pending availability of the new DPP board (DPP2). However, the functions have been written to allow easy expansion to two channels. (3) Light Collection Modeling--The XEPHWICH design has been modeled to determine its light capture efficiency. Research in the 7th quarter includes additional simulations representing significant increase in data resolution, well over an order of magnitude greater than previous simulations. The final data set represents approximately 11 billion visible photons divided equally among 110 thousand data points. A laboratory experiment is being designed and executed to experimentally determine light capture efficiency as a function of position within the scintillators. (4) Radioxenon Fission Source--We have designed and constructed a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. The aluminum housing and all vacuum fittings have been assembled, awaiting an HEU transfer from PNNL. Students have worked closely with PNNL and OSU Radiation Safety personnel to facilitate transfer of the HEU. The OSU TRIGA Reactor Operations Committee has approved the experiment. (5) Spectral (beta) Recognition--Spectral identification by a neural network developed in our laboratory was compared to that of solvers of a linear system of equations. Data indicate that our neural network is capable of identifying three beta emission sources ({sup 14}C, {sup 36}Cl, and {sup 99}Tc) simultaneously with reliability to within 3%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗