Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time of Flight (ToF)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Assessment of velocity/trajectory measurement technologies during a particle capture event

Since the early 1960s, the means to measure the time of flight (TOF) of dust grain within a mechanical detection array has existed, first in the laboratory and then in space experiments. Laboratory hypervelocity dust particle accelerators have used electrostatic detection of charge on accelerated particles for TOF and particle mass detections. These laboratory studies have led to the development of ultra-thin-film sensors that have been used for TOF measurements in dust particle space experiments. The prototypes for such devices were ultra-thin-film capacitors that were used in the OGO series of satellites. The main goal of the experimental work to be described is the development of the capability to determine the velocity vector or trajectory of a dust grain traversing an integrated dust detection array. The results of these studies have shown that the capability of detecting the charge liberated by hypervelocity dust grains with diameters in the micrometer range can be detected. Based on these results, detection systems have been designed to provide a precise analysis of the physical and dynamic properties of micrometer and submicrometer dust grains, namely the design verification unit (DVU). Through unique combinations of in situ detection systems, direct measurements of particle surface charge, velocity, momentum, kinetic energy, and trajectory have been achieved. From these measurements, the remaining physical parameters of mass, size, and density can be determined.

Tanner, William G.↗

Elemental mass spectroscopy of remote surfaces from laser-induced plasmas

The elemental mass analysis of laser-produced ions from Al, Cu, Ge, Ag, and a lunar simulant target when irradiated by a 400-mJ, 8-ns, Nd: YAG laser at 1 x 10(exp 9) W/cm(exp 2), is reported. Ions traveled down a 11.1-m evacuated tube to an ion-trap 1-m time-of-flight (TOF) mass spectrometer where an elemental mass spectrum was recorded. The amount of target material removed per laser pulse and the ionization fraction were measured. The ion spatial distribution was measured at 11.1-m distance and found to be near a fourth-power cosine distribution. These results indicate the ability to mass analyze a surface over a distance of many kilometers for lunar and asteroid surface elemental mass analysis by a remote satellite or lunar rover.

Situ, W.↗

A Novel Ultrasonic Method for Characterizing Microstructural Gradients in Tubular Structures

Ultrasonic velocity and time-of-flight (TOF) imaging that uses back surface reflections to gage volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse echo ultrasonic velocity and TOF imaging is that the image shows the effects of thickness as well as microstructural variations, unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse echo TOF based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples which, eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material in plate like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex shaped structures- those having (hollow) tubular or curved geometry. The experimental inspection technique and results are described as applied to a polymer matrix composite "proof of concept" tube that contains machined patches of various depths and an as manufactured monolithic silicon nitride ceramic tube that might be used in "real world" applications.

Roth, Don J.↗

Extraterrestrial Helium (He@C60) Trapped in Fullerenes in the Sudbury Impact Structure

Fullerenes (C60 and C70) have recently been identified in a shock-produced breccia (Onaping Formation) associated with the 1.85-Ga Sudbury Impact Crater. The presence of parts-per-million levels of fullerenes in this impact structure raises interesting questions about the processes that led to the formation of fullerenes and the potential for delivery of intact organic material to the Earth by a large bolide (e.g., asteroid or comet). Two possible scenarios for the presence of fullerenes in the Sudbury impact deposits are that (1) fullerenes are synthesized within the impact plume from the C contained in the bolide; or (2) fullerenes are already present in the bolide and survived the impact event. The correlation of C and trapped noble gas atoms in meteorites is well established. Primitive meteorites contain several trapped noble gas components that have anomalous isotopic compositions, some of which may have a presolar origin. Several C-bearing phases, including SiC, graphite, and diamond, have been recognized as carriers of trapped noble gases. It has also been suggested that fullerenes (C60 and C70) might be a carrier of noble gas components in carbonaceous chondrites. Recently, fullerenes have been detected in separate samples in the Allende meteorite. Carbon-60 is large enough to enclose the noble gases He, Ne, Ar, Kr, and Xe, but it is too small to contain diatomic gases such as N2 or triatomic gases such as CO2. Recent experimental work has demonstrated that noble gases of a specific isotopic composition can be introduced into synthetic fullerenes at high temperatures and pressures; these encapsulated gases can then be released by the breaking of one or more C bonds during step-heating under vacuum. These thermal-release patterns for He encapsulated within the C60 molecule (He@C60) are similar to the patterns for acid residues of carbonaceous chondrites, suggesting that fullerenes could be an additional carrier of trapped noble gases in acid residues of meteorites. Analysis and Results: In order to characterize the noble gas compositions of the Sudbury fullerenes, we undertook a systematic study of acid-resistant residues throughout the C-rich layer (Black member) of the Onaping Formation. Samples were demineralized and extracted using standard techniques. The Onaping extracts were analyzed using several techniques, including UV-Vis adsorption, electro spray mass spectrometry, and laser desorption (linear and reflectron) time-of-flight (TOF) mass spectrometry (LDMS). The Sudbury fullerenes were then separated and purified using HPLC coupled with a photo diode array detector. The HPLC extracts containing the purified fullerenes were loaded into a metal tube furnace within a glove box under a N atmosphere in preparation for noble gas analyses. The 3-He and 4-He content of the fullerene extracts was measured using previously reported standard techniques . Discussion: Fullerenes (C60 and C70) in the Sudbury Impact Structure have been found to contain trapped He with a 3-He/4-He ratio greater than 5 x 10(exp -4). The 3-He/4-He ratio exceeds the accepted solar value by more than 30% and is more than 10x higher than the maximum reported mantle value. Terrestrial nuclear reactions or cosmic-my bombardment are not sufficient to generate such a high ratio. The 3-He/4-He ratios in the Sudbury fullerenes are similar to those determined for interplanetary dust particles. The greater-than-solar ratios of 3-He/4-He in the Sudbury fullerenes may indicate a presolar origin, although alternative mechanisms occurring in the ISM to explain these high ratios (e.g., spallation reactions, selective He implantation, etc.) cannot be entirely ruled out. We are currently attempting to isolate enough fullerene material to measure anomalous Ne (or Kr or Xe) contained within the C60 (e.g., the "pure" 22-Ne component) and thus determine whether the Sudbury fullerenes are indeed presolar in origin.

Becker, L.↗

Scattering/Transmission of Energetic H+,He+, and O+ Through a Thin Composite Si/Lexan/C Foil

The need for a thin foil to serve both as an extreme ultraviolet (EUV) radiation attenuator and as a secondary electron generator for time-of-flight (TOF) instruments and energetic neutral atom (ENA) imagers has led us to test the scattering and transmission characteristics of a layered foil of nominal aerial thicknesses of 5 micrograms (raised dot) per square centimeter Si, 4 micrograms (raised dot) per square centimeter Lexan (C16H14O3), and 1 microgram (raised dot) per square centimeter C. We report the scattering/transmission results of subjecting this foil to H(+), He(+), and O(+) beams of energies less than or equal to 120 keV. The scattering of these particles, defined by the half-angular-width at half-maximum (HWHM), decreases with increasing energy and found to be 10 degrees for 10 keV H(+), 22 keV for He(+), and 100 keV for O(+). The 50% transmission threshold for these particles was found to be 3.9 keV for H(+), 8.6 keV for He(+), and 49.5 keV for O(+). Computer simulations of H(+)-foil interactions using SRIM96 agree well with the H(+) data, while yielding less scattering and higher transmission than indicated by the O(+) data.

Adrian, M. L.↗

Scattering/Transmission of Energetic H(sup +), He(sup +), and O(sup +) Through a Thin Composite Si/Lexan/C Foil

The need for a thin foil to serve both as an extreme ultraviolet (EUV) radiation attenuator and as a secondary electron generator for time-of-flight (TOF) instruments and energetic neutral atom (ENA) imagers has led us to test the scattering and transmission characteristics of a layered foil of nominal aerial thicknesses of 5 microns/sq cm Si, 4 microns/sq.cm Lexan ((C16)H(14)O3), and 1 micron/sq.cm C. We report the scattering and transmission results of subjecting this foil to H(sup +), He(sup +), and O(sup +) beams of energy less than 120 keV. The scattering of these particles, defined by the half-angular-width at half-maximum (HWHM), decreases with increasing energy and is found to be 10 deg for 10 keV H(sup +), 22 keV for He(sup +), and 100 keV for O(sup +). The 50% transmission threshold for these particles was found to be 3.9 keV for H(sup +), 8.6 keV for He(sup +), and 49.5 keV for O(sup +). Additionally, ion transmission shows evidence of resonance scattering from a rectangular potential independent of incident ion mass. Particularly evident is a local transmission minimum at 70 keV possessing a Gaussian-width of 20 keV. For incident energies below 50 keV, computer simulations of H+-foil interactions using SRIM96 agree well with the H(sup +) data, while yielding less scattering and higher transmission than indicated by the O(sup +) data.

Adrian, M. L.↗

Evaluating Mass Analyzers as Candidates for Small, Portable, Rugged Single Point Mass Spectrometers for Analysis of Permanent Gases

For Space Shuttle launch safety, there is a need to monitor the concentration Of H2, He, O2, and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida.

Arkin, C. Richard↗

Fullerenes, fulleranes and polycyclic aromatic hydrocarbons in the Allende meteorite

In this paper, we confirm our earlier observations of fullerenes (C60 and C70) in the Allende meteorite (Becker et al., 1994a, 1995). Fullerene C60 was also detected in two separate C-rich (approximately 0.5-1.0%) dark inclusions (Heymann et al., 1987) that were hand picked from the Allende sample. The amounts of C60 detected were approximately 5 and approximately 10 ppb, respectively, which is considerably less than what was detected in the Allende 15/21 sample (approximately 100 ppb; Becker et al., 1994a, 1995). This suggests that fullerenes are heterogeneously distributed in the meteorite. In addition, we present evidence for fulleranes, (C60Hx), detected in separate samples by laser desorption (reflectron) time-of-flight (TOF) mass spectrometry (LDMS). The LDMS spectra for the Allende extracts were remarkably similar to the spectra generated for the synthetic fullerane mixtures. Several fullerane products were synthesized using a Rh catalyst (Becker et al., 1993a) and separated using high-performance liquid chromatography (HPLC). Polycyclic aromatic hydrocarbons (PAHs) were also observed ppm levels) that included benzofluoranthene and corannulene, a cup-shaped molecule that has been proposed as a precursor molecule to the formation of fullerenes in the gas phase (Pope et al., 1993).

NASA Center ARC↗

Composition of Pickup Ions at Titan Observed by the Cassini Plasma Spectrometer

Pickup ions have been observed in Saturn's rotating magnetosphere near Titan by the Cassini Plasma Spectrometer (CAPS) instrument during the Cassini orbiter's recent flybys of the moon. A preliminary analysis of the CAPS Time of Flight (TOF) spectra of the pickup ions observed during the TA flyby indicated the presence of H(+), H2(+), N(+)/CH2(+), CH4(+), and N2(+). These ions slow down Saturn's magnetospheric plasma beyond Titan's ionosphere through mass loading. Because of its relatively high mass and high concentration, CH4(+) is the dominant mass loading ion. The other ions make negligible contributions to the mass loading process except for N2(+) just above the ionopause, where its concentration becomes important. With the exception of CH2(+), the pickup ion sources are the neutral exosphere constituents H, H2, N, CH4, and N2, where CH2 is a fragment of the parents CH4 and CH4(+). A more detailed analysis of CAPS TOF spectra and empirical cracking patterns is carried out to determine the relative concentrations of N(+) and CH2(+). Although, the 28 amu ion was identified as N2(+), consistent with the dominance of its neutral source, N2, just above the ionopause, the ionospheric ion HCNH(+) may also be present. The possible leakage of this and other ionospheric ions such as CH5(+) into the pickup ion /mass loading region is also examined by further analysis of the corresponding TOF spectra.

Hartle, R.↗

Electron Impact Ionization and Dissociative Ionization of C2H2

By utilizing a crossed electron beam collision geometry, a combination of time-of-flight (TOF) and quadrupole mass spectrometers, and the relative flow technique1 normalized values of cross sections and appearance energies (AP) were obtained for the formation of singly and multiply ionized species resulting from the ionization and dissociation of C2H2. Details ont he apparatus and technique have been published previously.2,3.

Electron Ionization↗

Miniature Mass Spectrometers on Space and Planetary Missions

Space flight mass spectrometers contribute our understanding of the origin and evolution of our solar system and even of life itself. This fundamental role has motivated increasing interest in miniature mass spectrometry for planetary missions. Several remarkable new instruments are en route or under development to investigate the composition of planetary bodies such as Mars and comets. For instance, the Sample Analysis at Mars (SAM) suite on the 2009 Mars Science Laboratory (MSL) mission includes a quadrupole mass spectrometer with a sophisticated gas processing system as well as pyrolysis and chemical derivatization protocols for solid samples. Future missions will require even lighter, lower power, and yet more capable mass spectrometers, particularly to analyze samples in situ on planetary surfaces. We have been developing laser-based mass spectrometers for elemental and organic/molecular analysis of rock, ice, or fine particle samples. These typically use time-of-flight (TOF) mass analyzers, which are readily miniaturized and can detect both atomic species and complex organics that occur in a variety of planetary materials. For example, nonvolatile polycyclic aromatic hydrocarbons and kerogen-like macromolecular carbon are found in some carbonaceous meteorites, which derived from asteroid parent bodies. A single focused laser pulse is able to volatilize and ionize some of these compounds for direct TOF analysis. While this is possible without any sample preparation or contact, sensitivity and quantitative performance can improve significantly with some sample handling. As such we have also been examining robotic mechanisms and protocols to accompany space flight mass spectrometers. In addition, sensors in early development may significantly improve these capabilities, via use of techniques such as switchable polarity, ambient pressure, or resonant ionization; tandem mass spectrometry (TOF or ion trap); and chemical imaging.

Brinckerhoff, William↗

Transient Plume Model Testing Using LADEE Spacecraft Attitude Control System Operations

We have learned it is conceivable that the Neutral Mass Spectrometer on board the Lunarr Atmosphere Dust Environment Explorer (LADEE) could measure gases from surface-reflected Attitude Control System (ACS) thruster plume. At minimum altitude, the measurement would be maximized, and gravitational influence minimized ("short" time-of-flight (TOF) situation) Could use to verify aspects of thruster plume modeling Model the transient disturbance to NMS measurements due to ACS gases reflected from lunar surface Observe evolution of various model characteristics as measured by NMS Species magnitudes, TOF measurements, angular distribution, species separation effects

Woronowicz, Michael↗

Radiation Design of Ion Mass Spectrometers

In the harsh radiation environment of Jupiter and with the JUpiter ICy moon Explorer (JUICE) mission including two Europa flybys where local intensities are approx. 150 krad/month behind 100 mils of Al shielding, so background from penetrating radiation can be a serious issue for detectors inside an Ion Mass Spectrometer (IMS). This can especially be important for minor ion detection designs. Detectors of choice for time-of-flight (TOF) designs are microchannel plates (MCP) and some designs may include solid state detectors (SSD). The standard approach is to use shielding designs so background event rates are low enough that the detector max rates and lifetimes are first not exceeded and then the more stringent requirement that the desired measurement can successfully be made (i.e., desired signal is sufficiently greater than background noise after background subtraction is made). GEANT codes are typically used along with various electronic techniques, but such designs need to know how the detectors will respond to the simulated primary and secondary radiations produced within the instrument. We will be presenting some preliminary measurements made on the response of MCPs to energetic electrons (20 ke V to 1400 ke V) using a Miniature TOF (MTOF) device and the High Energy Facility at Goddard Space Flight Center which has a Van de Graaff accelerator.

Sittler, Ed↗

Laser Ablation Mass Spectrometer (LAMS) as a Standoff Analyzer in Space Missions for Airless Bodies

A laser ablation mass spectrometer (LAMS) based on a time-of-flight (TOF) analyzer with adjustable drift length is proposed as a standoff elemental composition sensor for space missions to airless bodies. It is found that the use of a retarding potential analyzer in combination with a two-stage reflectron enables LAMS to be operated at variable drift length. For field-free drift lengths between 33 cm to 100 cm, at least unit mass resolution can be maintained solely by adjustment of internal voltages, and without resorting to drastic reductions in sensitivity. Therefore, LAMS should be able to be mounted on a robotic arm and analyze samples at standoff distances of up to several tens of cm, permitting high operational flexibility and wide area coverage of heterogeneous regolith on airless bodies.

Li, X.↗

Advanced Electronics for the SONTRAC Neutron Spectrometer

Solar neutrons are the tell-tale of highly energetic processes (e.g. solar flares) at the Sun in which particle acceleration is taking place over a broad range in energy. Unlike charged radiation, neutrons escape unscathed from the ambient magnetic fields, providing a view of particle acceleration unhindered by the effects of transport. High-energy neutrons are challenging to measure with the traditional double scatter technique based on time-of-flight (ToF). This technique is limited by the finite flight path and active scintillator sizes required by small satellite platforms. The new SOlar Neutron TRACking (SONTRAC) concept, based on scintillating-fiber bundles, will provide high resolution imaging of fast neutrons at energies where the bulk of solar and magnetospheric neutrons resides. Recent development of the new SONTRAC instrument concept's advanced electronics and processing algorithms are presented.

SiPM readout↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

Fast neutrons (energies >0.5 MeV) contribute to the radiation exposure of space hardware and astronaut crew, enable greater understanding of planetary atmospheric and surface compositions and allow unique measurements of solar particle acceleration. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement. These measurements are challenging due to size constraints on satellites, particularly newer small satellites. The SOlar Neutron TRACking instrument (SONTRAC) is a small satellite neutron detector that utilizes fine-grained scintillating fiber bundles with 1-mm pitch silicon photomultiplier (SiPM) array readout. Signal processing is accomplished with multichannel ASICs. SONTRAC is able to image fast neutron (between 20-200 MeV) scatters in a compact scalable package. We discuss below the numerous applications of this technology and recent progress on the development and performance characteristics of the prototype instrument.

Georgia A de Nolfo↗

Lunar Asset Messaging and On Orbit Navigation

NASA has titled its 2020 thrust for the Moon, Artemis. The increased focus on the Moon as a destination for future human and robotic expeditions necessitates general purpose navigational and communications infrastructure reducing their complexity to help establish a sustained presence. A framework through which Lunar missions can relay communications and localize their positions shifts the burden from the individual mission and enables resource allocation tailored to mission-specific goals. During the summer of 2020, student interns under the Innovation to Flight (i2F) program at the National Aeronautics and Space Administration’s (NASA) Jet Propulsion Laboratory (JPL) in collaboration with the University of Colorado Boulder designed, built, and tested a prototype framework capable of providing surface assets with communication and positioning services. The team utilized the existing i2F CubeSat bus in addition to developing several CubeSat engineering development units (EDUs), a ground vehicle, and a ground station to simulate a scenario in which a lunar surface mission is supported by these services. A primary goal of the summer was to develop a method for localizing the ground vehicle through trilateration. Distances are inferred from the round-trip time of flight (ToF) of radio signals between an asset and several elements. Signals were sent and received using LimeSDR software defined radios on-board both the ground vehicle and the EDUs; ToF and trilateration were calculated on a Qualcomm Snapdragon development board located within the LA MOON payload data system. The ModalAI chipset on the Qualcomm was instrumental in executing visual based position estimation. Communications was facilitated through a bent-pipe approach addressing the NASA requirement to provide solutions for in communication denied locations. The ground vehicle relayed information to other surface assets in addition to its ground station through the supporting constellation. This project demonstrates the feasibility of a lunar CubeSat constellation for the support of surface assets and explores packaging and operations of the components critical to trilateration and bent-pipe communication into a standard CubeSat form factor. When implemented, this framework will open a door for new surface missions designed with lower power requirements and increased operational access.

Huang, Calvin↗

Ruggedizing a Commercial Depth Camera for Novel Lunar Exploration.

The novel contribution of this instrument is to take the first depth images on the moon. A commercial Kinect camera from Microsoft has been ruggedized for a CLPS mission to the Lunar South Pole. The 12-megapixel color camera is combined with a 1-megapixel color time-of-flight (ToF) depth sensor. The solid-state depth sensor/LIDAR provides greater resolution, a wider field of view, pixel binning, and reduced power consumption. The high-resolution data collected from the mission can be used to construct a near-field virtual environment of the lunar surface for scientific applications. The depth camera can provide a 360-degree view of the target area by combining ToF data with RGB imagery and rover turning. The unit was evaluated for space flight compliant materials and parts at NASA Ames. The microphone array, RF shield, front face, and outer body parts were removed to reduce mass. Plastic parts were replaced with vacuum-compatible materials; manufactured cables were added to properly interface with the host rover, built by Lunar Outpost. The environmental testing was performed on the Kinect with Random Vibration/Sine Testing (Fig 1a), per GEVS (NASA’s General Environmental Verification Standard for spaceflight launch survival). Thermal Vacuum testing cycled the instrument between expected hot (+ 85 C) and cold survival temperatures, as well as +50 C and -25 C operational temps (Fig 1b). The instrument functioned nominally at the conclusion of vibration and thermal cycling tests. The Azure Kinect is manifested on the Nova-C lander which flies on the Intuitive Machines mission IM-2, landing at the lunar south pole for a mission duration of 14 days (one lunar daylight cycle). The unit will be integrated to the MAPP (Mobile Autonomous Prospecting Platform) rover at Lunar Outpost. The Azure Kinect with ToF feature will improve the resolution of lunar geology data near the south pole and enable ground-based VR experience of details of the lunar surface (Fig 1c).

V. Jha↗