Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time of Flight (ToF)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the diffusion of Kr in UO 2 and ADOPT TM using time-of-flight elastic recoil detection analysis (ToF-erda)

A combination of 300 keV 84 Kr ion implantation and Time-of-Flight Elastic Recoil Detection Analysis is utilized to investigate the diffusion of Kr in UO 2 and ADOPT TM fuels. Composition depth-profiles on the nanometer scale were obtained, both for as-implanted samples and after annealing at 800°C for 1 hour. Observed drifts in the 84 Kr profiles could be associated with short-range diffusion mechanisms. The approach employed here provides the possibility to make direct comparisons with atomistic scale modelling data, and can be of service as a separate effect test in line with the Accelerated Fuel Qualification initiative.

ADOPT UO2↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep learning-based temporal deconvolution for photon time-of-flight distribution retrieval

The acquisition of the time of flight (ToF) of photons has found numerous applications in the biomedical field. Over the last decades, a few strategies have been proposed to deconvolve the temporal instrument response function (IRF) that distorts the experimental time-resolved data. However, these methods require burdensome computational strategies and regularization terms to mitigate noise contributions. Herein, we propose a deep learning model specifically to perform the deconvolution task in fluorescence lifetime imaging (FLI). The model is trained and validated with representative simulated FLI data with the goal of retrieving the true photon ToF distribution. Its performance and robustness are validated with well-controlled in vitro experiments using three time-resolved imaging modalities with markedly different temporal IRFs. The model aptitude is further established with in vivo preclinical investigation. Overall, these in vitro and in vivo validations demonstrate the flexibility and accuracy of deep learning model-based deconvolution in time-resolved FLI and diffuse optical imaging.

Pandey, Vikas (ORCID:0000000154771095)↗

Method and apparatus for radiation detection based on time-of-flight within optical fibers

A radiation detection system using time of flight (TOF) information within multiple optical fiber complexes coupled with a scintillating material at intersections of repeatedly crossing over shape. Light detectors are placed at the ends of each fiber to detect scintillation events. A timing processor is collecting light detector signal to compute TOF difference and estimate the location and strength of radioactivity. The system is scalable in one dimension, capable of being shaped or curved, and customizable in terms of special resolution and sensitivity. The system is suitable for long range and coarse radiation detection.

Lee, Seung Jae↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Spatiotemporal evolution of emission and absorption signatures in a laser-produced plasma

Here we report spatiotemporal evolution of emission and absorption signatures of Al species in a nanosecond (ns) laser-produced plasma (LPP). The plasmas were generated from an Inconel target, which contained ~0:4 wt. % Al, using 1064 nm, ≈6 ns full width half maximum pulses from an Nd:YAG laser at an Ar cover gas pressure of ≈34 Torr. The temporal distributions of the Al I (394.4 nm) transition were collected from various spatial points within the plasma employing time-of-flight (TOF) emission and laser absorption spectroscopy, and they provide kinetics of the excited state and ground state population of the selected transition. The emission and absorption signatures showed multiple peaks in their temporal profiles, although they appeared at different spatial locations and times after the plasma onset. The absorption temporal profiles showed an early time signature representing shock wave propagation into the ambient gas. We also used emission and absorption spectral features for measuring various physical properties of the plasma. The absorption spectral profiles are utilized for measuring linewidths, column density, and kinetic temperature, while emission spectra were used to measure excitation temperature. A comparison between excitation and kinetic temperature was made at various spatial points in the plasma. Our results highlight that the TOF measurements provide a resourceful tool for showing the spatiotemporal LPP dynamics with higher spatial and temporal resolution than is possible with spectral measurements but are difficult to interpret without additional information on excitation temperatures and linewidths. The combination of absorption and emission TOF and spectral measurements thus provides a more complete picture of LPP spatiotemporal dynamics than is possible using any one technique alone.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SUDA: A SUrface Dust Analyser for Compositional Mapping of the Galilean Moon Europa

Abstract The Surface Dust Analyser (SUDA) is a mass spectrometer onboard the Europa Clipper mission for investigating the surface composition of the Galilean moon Europa. Atmosphereless planetary moons such as the Galilean satellites are wrapped into a ballistic dust exosphere populated by tiny samples from the moon’s surface produced by impacts of fast micrometeoroids. SUDA will measure the composition of such surface ejecta during close flybys of Europa to obtain key chemical signatures for revealing the satellite’s composition such as organic molecules and salts, history, and geological evolution. Because of their ballistic orbits, detected ejecta can be traced back to the surface with a spatial resolution roughly equal to the instantaneous altitude of the spacecraft. SUDA is a Time-Of-Flight (TOF), reflectron-type impact mass spectrometer, optimized for a high mass resolution which only weakly depends on the impact location. The instrument will measure the mass, speed, charge, elemental, molecular, and isotopic composition of impacting grains. The instrument’s small size of$268 ~\mathrm {mm} \times 250 ~\mathrm {mm} \times 171$ 268 mm × 250 mm × 171 $~\mathrm {mm}$ mm , radiation-hard design, and rather large sensitive area of 220 cm 2 matches well the challenging demands of the Clipper mission.

Astronomy & Astrophysics↗

Evaluation of electron lifetime for Te inclusions free CdZnTe

Te secondary phase defects are known as major obstacle for improving charge carriers transport properties of CdTe compounds material. The enhanced detector performance was reported for Te inclusions free CZT detector implemented through two-step annealing (i.e., first in Cd and second in Te). Here, we applied the time-of-flight (TOF) technique to measure the electron lifetime in as-grown and two-step annealed CZT material. TOF has several advantages over Hecht equation fitting such as independence of the electric field distribution, direct measurement of carrier lifetime, and high accuracy for high mobility-lifetime product CZT material. The detector performance improved drastically for the two-step annealed CZT detector except which containing inordinate number and size of prismatic punching defects. The average electron lifetime increased more than 10 times after successful two-step annealing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Progress on Associated-Particle Imaging Algorithms, 2022

The present work describes progress on developing imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating among critical materials or extracting three-dimensional (3D) geometrical information from single-sided or transmission measurements. The present work is divided into three approaches: 1.Iterative reconstruction of inelastic gamma-ray emissions to perform 3D time-of-flight (TOF) imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution. 2.Decomposition of registered neutron and x-ray radiographs into an assumed material list for each pixel in the image. 3.Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles. Progress for each approach is summarized for fiscal year (FY) 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

Angular scattering of protons through ultrathin graphene foils: Application for time-of-flight instrumentation

Space plasma instruments often rely on ultrathin carbon foils for incident ion detection, time-of-flight (TOF) mass spectrometry, and ionization of energetic neutral atoms. Angular scattering and energy loss of ions or neutral atoms in the foil can degrade instrument performance, including sensitivity and mass resolution; thus, there is an ongoing effort to manufacture thinner foils. Using new 3-layer graphene foils manufactured at the Los Alamos National Laboratory, we demonstrate that these are the thinnest foils reported to date and discuss future testing required for application in space instrumentation. We characterize the angular scattering distribution for 3–30 keV protons through the foils, which is used as a proxy for the foil thickness. We show that these foils are ~2.5–4.5 times thinner than the state-of-the-art carbon foils and ~1.6 times thinner than other graphene foils described in the literature. We find that the inverse relationship between angular scattering and energy no longer holds, reaffirming that this may indicate a new domain of beam–foil interactions for ultrathin (few-layer) graphene foils.

47 OTHER INSTRUMENTATION↗

µRWELL-PICOSEC: The Development of Fast Timing Resistive Micro-WELL Detector Technology.

We present the development of a new concept of fast timing gaseous detector, the ?RWELL-PICOSEC detector based on Resistive Micro-Well (?RWELL) technology to provide timing resolution in the tens of picosecond range for application as time-of-flight (TOF) technology in the particle physics and medical instrumentation fields. The ?RWELL-PICOSEC technology combined a Cerenkov radiator for the generation of Cerenkov photons from high energy charged particles, a photocathode for the conversion of the produced photons into primary electrons and the ?RWELL foil for the multiplication of the electron to produce large signal on pad segmentation readout. The proof of concept of ?RWELL-PICOSEC is demonstrated with a small single-channel prototype and preliminary timing performance of 90 ps has been measured. Optimization study the amplification structure of ?RWELL-PICOSEC for the improvement of timing resolution is discussed and results on timing performance studies in beam at CERN are presented. The development of large area (100 mm × 100 mm) ?RWELL-PICOSEC and associated multichannel fast readout electronics and data acquisition system are also reported

Weisenberger, Andrew↗

On the instrument-dependent appearance of ion dissociation events in atom probe tomography mass spectra

The successful application of atom probe tomography (APT) relies on the accurate interpretation of the mass spectrum (i.e. m/z histogram) from a sample. Some materials yield mass spectra that are amenable to a straightforward peak assignment/ranging, however, there are many materials that produce mass spectra with features that defy simple interpretation. One such example is Ga 2 O 3 which yields mass spectra containing several broad and difficult to interpret features. Herein, we study the GaO 2+ → O 1+ + Ga 1+ dissociation and we explain how this dissociation process gives rise to broad and previously unassigned features in the mass spectrum. Trajectory simulations are performed for the dissociation reaction utilizing realistic electrostatic models and compared to experiments using commercially available straight flight and reflectron based local electrode (LE) APT instruments. It is shown that the appearance of these features is strongly dependent on the specific design of the time-of-flight (ToF) mass analyzer. Additionally, we explore how various experimental parameters can affect the appearance of the dissociation process in the one-dimensional (1D) mass spectrum and in the two-dimensional (2D) correlation histogram. While the focus of this work is on a particular dissociation process related to Ga 2 O 3 , the understanding gained in the course of these simulations and experiments should be applicable to the interpretation of dissociation processes in other materials.

47 OTHER INSTRUMENTATION↗

POWTEX visits POWGEN

The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗