Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

Time Resolved Particle Image Velocimetry in Nozzle Flow

Temporally resolved particle image velocimetry (TR-PIV) is the newest and most exciting tool recently developed to support our continuing efforts to characterize and improve our understanding of the decay of turbulence in jet flows—a critical element for understanding the acoustic properties of the flow. A new TR-PIV system has been developed at the NASA Glenn Research Center which is capable of acquiring planar PIV image frame pairs at up to 25 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered six nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centred along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space–time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

Temporally Resolved Particle Image Velocimetry↗

Time-resolved particle image velocimetry measurements of the turbulent Richtmyer–Meshkov instability

Experiments are presented on the Richtmyer–Meshkov instability (RMI) with a three-dimensional, multi-mode initial perturbation. The experiments use a vertical shock tube, where a stably stratified interface is formed between air and sulphur hexafluoride (SF 6 ) via counterflow. A perturbation is imposed at the interface by vertical oscillation of the gas column, forming Faraday waves. The interface is accelerated by a Mach 1.17 (in air) shock wave, and the development of the mixing region between the gases is investigated using particle image velocimetry. Following shock acceleration, a reflected shock wave from the bottom of the shock tube interacts with the mixing layer a second time (reshock). The experiment is initialized with both high and low amplitude perturbations to examine the effect of the perturbation amplitude on measured quantities. The instability growth exponent (θ) is determined from the kinetic energy field using the width of the mixing layer and the decay of kinetic energy, which are found to be in agreement when the flow is most strongly excited. A growth exponent of θ ≈ 0.5 is found for all cases except the high-amplitude reshocked regime (where θ ≈ 0.33). High-amplitude experiments exhibit the transitional outer Reynolds number (Re ≡ hh˙/ν >10 4 ) required for mixing transition following the incident shock, and both experiments are elevated well above this threshold following reshock. However, neither set of experiments meet the more stringent requirements proposed by Zhou et al. (Phys. Rev.E, vol. 67, issue 5, 2003) which include the time dependent aspect of the RMI, an observation which is also made when examining the spectra.

42 ENGINEERING↗

Two-dimensional burn velocity and analysis of burn products of nitromethane at high pressure

We have studied the laser-initiated deflagration of nitromethane (CH 3 NO 2 ) under high static pressure in the diamond anvil cell. Time-resolved images of the deflagrations have been obtained using intensified CCDs (ICCD). In contrast with previous work, we rely on spontaneous emission from the reaction, rather than changes in the speckle pattern produced by artificial illumination of the sample. Furthermore, as opposed to the 1D records obtained previously with streak cameras, ICCDs permit imaging of the burn in two dimensions providing the ability to directly observe anisotropic deflagration behavior. Here, we report several examples of this behavior and discuss its possible origins. We have also investigated the products of the reaction using Raman spectroscopy. At pressures below 25 GPa, the burn product is observed to be opaque and has a Raman spectrum consistent with a carbonaceous soot. At pressures above 25 GPa, the burn product is observed to be transparent (consistent with earlier reports) and its Raman spectrum reveals the presence of molecular N 2 and a nitrogen-carbonate species. The latter species can be recovered to ambient pressure and has a Raman spectrum consistent with ammonium carbonate or ammonium bicarbonate. To aid interpretation of the Raman spectra, measurements have also been made on the isotopologues CH 3 15 NO 2 and 13 CH 3 NO 2 . This work establishes the importance of advanced time-resolved imaging to reveal the details of deflagration under high pressure and further advances our understanding of the corresponding chemistry.

Deflagration↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Longitudinal position dependence of dark line defect growth rate in high-power diode lasers at 790 nm

Using a nondestructive, in situ near-infrared defect imaging technique, we obtained time-resolved images of dark line defect (DLD) growth in the cavities of several high-power 790-nm diode lasers and calculated individual DLD growth rates. A clear longitudinal spatial dependence in the DLD growth rate was observed, in which the DLD growth rate was faster near the anti-reflective (AR) facet. Longitudinal spatial hole burning simulation results indicate that the total photon density increases toward the AR facet, while the carrier density decreases toward the AR facet. Here, these results suggest that photon absorption plays a key role in enhancing DLD growth beyond the contribution of the traditional carrier capture mechanism. Asymmetric DLD growth that was preferentially directed toward the high-reflectivity facet was also observed, providing further support for the role of photon absorption in the growth process. To account for these findings, we propose a photon-accelerated mechanism for the enhancement of DLD growth in which the slower carrier capture process in the traditional recombination-enhanced dislocation glide mechanism is replaced by a faster photon absorption process.

Engineering - Electronic and electrical engineerin↗

Space-resolved spectra of laser-produced plasmas in the XUV

The design and imaging properties of an XUV (extreme ultraviolet, 200-550 A) normal-incidence slitless spectrograph, the spectrum obtained from laser-generated plasmas, and the monochromatic plasma images are described. The electron temperature of the plasmas, electron density as a function of position in the plasma, and the thickness of material penetrated by the laser pulse are determined. Elements from Z = 6 to Z = 28 were investigated, in addition to Nb. Secondary plasma-emission regions were observed 2-3 mm from the flat (thick or thin) targets. Time-integrated photographs of the expanding plasmas were recorded by the slitless spectrograph. A technique for obtaining time-resolved images of the plasmas in picosecond time intervals is proposed, and problems in the design of a stigmatic XUV spectrograph are discussed.

Feldman, U.↗

The influence of laser energy on deuterium emission characteristics from a Zircaloy-4 plasma

Laser-produced plasma coupled with optical emission spectroscopy (OES) is a promising technique for detecting certain isotopes, with unique capabilities such as standoff and rapid detection and minimal to no sample preparation requirements. The key figure-of-merit for isotopic analysis using optical spectroscopy tools is the linewidth relative to the isotope shift. Although the isotopes of hydrogen (1H, 2H, and 3H) possess large isotopic shifts (1H–2H ≈ 180 pm, 1H–3H ≈ 240 pm), being a light element, the H transitions are susceptible to various broadening mechanisms in the plasma environment. One of the critical parameters that influence the linewidth of a transition in an LPP is the incident laser energy. In the present study, we evaluated the role of laser energy on plume expansion dynamics, deuterium emission intensity, and linewidth in a nanosecond laser-produced Zircaloy-4 plasma. The changes in 2Hα emission intensity and linewidth were investigated for varying laser fluence and time after plasma onset. Spatially resolved and spatially integrated OES were performed and compared to investigate the emission spectral features and linewidth of 2Hα. Monochromatic two-dimensional time-resolved imaging was also performed to understand the morphology of the deuterium and protium emission relative to all species in the plume. Our results showed that 1Hα and 2Hα emissions predominantly occur closer to the target. Measurements of 2Hα linewidth approached similar values at later times of plasma evolution regardless of the laser energy. The linewidths of the 2Hα transition showed insignificant differences between spatially resolved and spatially integrated measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence of restricted heat transport in National Ignition Facility Hohlraums

We present experimental evidence of restricted electron thermal conduction in the high-Z coronal plasma regions of laser-driven Hohlraums on the National Ignition Facility. Four separate measurements, three of which are direct observations of Hohlraum dynamics, corroborate this finding. (1) The velocity of the coronal plasma ablated and heated by the outer-cone laser beams is determined by time-dependent imaging of the gold plasma plume, or “bubble.” The velocities of the incoming plume (perpendicular to the Hohlraum axis) are consistent with high-fidelity 2D radiation-hydrodynamic simulations using flux-limited thermal electron conduction with a flux multiplier f = 0.03. Simulations using f = 0.15, which is very nearly classical Spitzer–Härm transport, predict plume velocities slower than measured. (2) Specific features in time-resolved images of the Hohlraum wall at an angle of 19° are also more consistent with f = 0.03 simulations compared to f = 0.15. (3) Spectroscopic tracers were added to the Hohlraum wall in the outer-beam bubble region. The ratios of hydrogen-like to helium-like line emission are sensitive to the electron temperature of the bubble. The hydrogen-like to helium-like ratios extracted from the time-integrated spectra of manganese and cobalt tracers from two observation angles are consistent with f = 0.03 and not with f = 0.15. (4) The time of peak capsule emission, or “bang time,” an integrated measurement, is also more consistent with f = 0.03 than with f = 0.15. Overall, while these findings do not identify the causes of restricted thermal conduction in Hohlraums, they motivate future experiments to test specific hypotheses and focus on model development in the regions of the plasma exhibiting restricted transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging suprathermal x-rays from a laboratory plasma jet using PIN-diode-based and scintillator-based 1D pinhole/coded aperture cameras

A PIN-diode-based 1D x-ray camera and a scintillator-based 1D x-ray camera, both with a microsecond to submicrosecond time resolution, have been developed to perform time-resolved imaging of transient, low-intensity, suprathermal x-rays associated with magnetohydrodynamic instabilities disrupting a plasma jet. These cameras have a high detection efficiency over a broad x-ray band, a wide field of view, and the capability to produce >50 time-resolved frames with a ≤1 μs time resolution. The x-ray images are formed by a pinhole or by a coded aperture placed outside a vacuum chamber in which the plasma jet is launched. The 1D imaging shows that the location of the x-ray source is either a few centimeters away from an inner disk electrode or near a spatially translatable metal frame that is 30–40 cm away from the electrode. Compared to a pinhole, a coded aperture increases the signal collection efficiency but also introduces unwanted artifacts.

Instruments & Instrumentation↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗

First study of Hohlraum x-ray preheat asymmetry inside an ICF capsule

In indirect drive inertial confinement fusion (ICF), laser induced Hohlraum preheat radiation (so-called M-band, >1.8 keV) asymmetry will lead to asymmetric ablation front and ablator–fuel interface hydrodynamic instability growth in an imploding capsule. First experiments to infer the M-band asymmetries at the capsule were performed on the National Ignition Facility for high density carbon (HDC) ICF capsules in low density fill (0.3 mg/cc 4 He) Au Hohlraums by time resolved imaging of 2.3 keV fluorescence emission of a smaller Mo sphere placed inside the capsule. In this study, the measured Mo emission is pole hot (P 2 > 0) since M-band is generated mainly by the outer laser beams as their irradiance at the Hohlraum wall is 5× higher than for the inner beams. P 2 has a greater negative than positive swing vs time [Δ(P 2 /P 0 )/Δt ~ 0.2/ns], giving insight into laser heated Hohlraum dynamics. P 4 asymmetry is small at the sphere due to efficient geometric smoothing of Hohlraum asymmetries at large Hohlraum -to-capsule ratios. The M-band P 2 history is qualitatively reproduced by radiation hydrodynamic HYDRA simulations. The smaller P 2 than that calculated earlier suggests either less outer beam spot motion and/or preheat emission. At late times, the observed P 2 swing is larger and P 4 is more negative than simulated, which could be due to inner beams being stopped more in the outer beams wall plasma bubble than simulated. Asymmetry at the HDC capsule inner surface (“ice–ablator interface”) is also inferred from the Mo emission asymmetry by an analytic viewfactor model, accounting for the Mo/HDC radius difference and HDC capsule opacity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contrasting the characteristics of atmospheric pressure plasma jets operated with single and double dielectric material: physicochemical characteristics and application to bacterial killing

Abstract This study reports an experimental comparison of two types of atmospheric pressure plasma jets in terms of their fundamental plasma characteristics and efficacy in bacterial sterilization. The plasma jets are fabricated by inserting a high voltage electrode inside a one-end closed (double DBD plasma jet) or both ends open (single DBD plasma jet) quartz tubes which are further enclosed inside a second quartz tube containing a ground electrode. Both plasma jets are operated in contact with water surface by using a unipolar pulsed DC power supply with helium as the working gas. Results from electrical and time-resolved imaging show that the single DBD configuration induces 3–4 times higher accumulation of charges onto the water surface with significantly faster propagation of plasma bullets. These results are accompanied by the higher discharge intensity as well as stronger emissions from short-lived reactive species which were analyzed through optical emission spectroscopy at the plasma-water interface. The rotational temperature for the single DBD configuration was observed to be higher making it unsafe for direct treatments of sensitive biological targets. These characteristics of the single DBD configuration result in the production of more than two times higher concentration of H 2 O 2 in plasma activated water. Shielding of the HV electrode reduces the plasma potential which in turn reduces the electric field & electron energy at the plasma-water interface. The reduced electric field for the double DBD configuration was lower by ≈463 Td than the single DBD configuration. The bactericidal efficacy of the two configurations of the plasma jets were tested against Escherichia coli , a well studied Gram-negative bacterium that can be commensal and pathogenic in human body. Our results demonstrate that although single DBD plasma jet result in stronger antibacterial effects, the double DBD configuration could be safer.

Physics↗

Time Resolved Stereo Particle Image Velocimetry Measurements of the Instabilities Downstream of a Backward-Facing Step in a Swept-Wing Boundary Layer

Time-resolved particle image velocimetry (TRPIV) measurements are performed down-stream of a swept backward-facing step, with a height of 49% of the boundary-layer thickness. The results agree well qualitatively with previously reported hotwire measurements, though the amplitudes of the fluctuating components measured using TRPIV are higher. Nonetheless, the low-amplitude instabilities in the flow are fairly well resolved using TR- PIV. Proper orthogonal decomposition is used to study the development of the traveling cross flow and Tollmien-Schlichting (TS) instabilities downstream of the step and to study how they interact to form the large velocity spikes that ultimately lead to transition. A secondary mode within the traveling cross flow frequency band develops with a wavelength close to that of the stationary cross flow instability, so that at a certain point in the phase, it causes an increase in the spanwise modulation initially caused by the stationary cross flow mode. This increased modulation leads to an increase in the amplitude of the TS mode, which, itself, is highly modulated through interactions with the stationary cross flow. When the traveling cross flow and TS modes align in time and space, the large velocity spikes occur. Thus, these three instabilities, which are individually of low amplitude when the spikes start to occur (U'rms/Ue <0.03), interact and combine to cause a large flow disturbance that eventually leads to transition.

Eppink, Jenna L.↗

Milestone report for MRT 8479: High Yield Xray Imager Preliminary Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi-MJ yield shots. Also, a new radiation tolerance CMOS imaging array is being developed to eliminate the significant background noise which limits the data quality of PDIXI. The HYXI Preliminary Design Review was completed at the end of Q4 FY23. The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the new CMOS imaging array. Initial time integrated NIF data will be collected in Q2 FY25, first time resolved imaging with Daedalus starting in Q2 FY26 and the final performance qualification of the complete HYXI system is scheduled for Q2 FY27.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗