Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time-of-flight neutron diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Lorentz factor for time-of-flight neutron Bragg and total scattering

We report the three fundamental origins of the Lorentz factor for neutron time-of-flight powder diffraction are revisited. A detailed derivation of the Lorentz factor is presented in the context of diffuse scattering modelling in reciprocal space when perfect periodicity is assumed, and the total scattering pattern is constructed in its discrete form – the factor in this case becomes 1/Q 2 (or d 2 ). Discussion is also presented with respect to practical data reduction where a vanadium measurement is usually taken as the normalization factor (to account for various factors such as detector efficiency), and it is shown that the existence of the Lorentz factor is independent of such a normalization process.

36 MATERIALS SCIENCE↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Neutron diffraction probing hydrogen in monoclinic H 2 VOPO 4

Light hydrogen atoms are resolvable with neutrons; however, the massive incoherent background inhibits the diffraction quality. To improve the signal, isotope treatment by deuteration becomes a prerequisite for a successful crystallographic understanding of hydrogen-containing materials by neutron diffraction. Thanks to the low-background and high-resolution time-of-flight neutron diffractometer, this work demonstrates a direct and successful measurement of high-quality neutron diffraction patterns of H 2 VOPO 4 powders, a precursor of a high-capacity alkali-ion battery cathode. The Rietveld refinement identifies the hydrogen coordinates, occupancy, and thermal parameters in the H 2 VOPO 4 lattice. Finally, the result highlights the unique capability of neutron diffraction for the structure characterization of hydrogen-containing materials, potentially without requiring costly and possibly artifact-inducing deuteration for neutron diffraction.

36 MATERIALS SCIENCE↗

Neutron diffraction: a primer

Because of the neutron’s special properties, neutron diffraction may be considered one of the most powerful techniques for structure determination of crystalline and related matter. Neutrons can be released from nuclear fission, from spallation processes, and also from low-energy nuclear reactions, and they can then be used in powder, time-of-flight, texture, single crystal, and other techniques, all of which are perfectly suited to clarify crystal and magnetic structures. With high neutron flux and sufficient brilliance, neutron diffraction also excels for diffuse scattering, for in situ and operando studies as well as for high-pressure experiments of today’s materials. For these, the wave-like neutron’s infinite advantage (isotope specific, magnetic) is crucial to answering important scientific questions, for example, on the structure and dynamics of light atoms in energy conversion and storage materials, magnetic matter, or protein structures. In this primer, we summarize the current state of neutron diffraction (and how it came to be), but also look at recent advances and new ideas, e.g., the design of new instruments, and what follows from that.

36 MATERIALS SCIENCE↗

Synthesizing pseudo-Kossel lines from neutron transmission data. II. Validation with neutron diffraction data

A new method to recover the orientation matrix of a single crystal with a known unit cell by analyzing synthesized pseudo-Kossel lines from time-of-flight neutron transmission data has been outlined in a companion article [Dessieux et al. (2023). J. Appl. Cryst. 56, https://dx.doi.org/10.1107/S1600576723001346; referred to here as Article I]. In this work, validation of this new technique is presented by employing experimental neutron transmission and diffraction measurements performed on two copper single-crystal specimens. Time-of-flight spectra were recorded during rotation (ω) of the single crystals about a vertical axis perpendicular to the incident neutron beam. The λ–ω maps recorded in transmission are utilized to determine the crystal orientation with respect to the neutron beam, following the procedure presented in Article I. Further, to validate the indexing procedure, the crystal orientations are compared with those obtained via conventional methods using the diffraction data. The resulting pseudo-Kossel lines across the 2D detectors are also observed for the first time.

36 MATERIALS SCIENCE↗

POWTEX visits POWGEN

The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Charged Defects in Ferroelectrics by the Switching Spectroscopy Piezoresponse Force Microscopy

Monitoring the charged defect concentration at the nanoscale is of critical importance for both the fundamental science and applications of ferroelectrics. However, up-to-date, high-resolution study methods for the investigation of structural defects, such as transmission electron microscopy, X-ray tomography, etc., are expensive and demand complicated sample preparation. Here, with an example of the lanthanum-doped bismuth ferrite ceramics, a novel method is proposed based on the switching spectroscopy piezoresponse force microscopy (SSPFM) that allows probing the electric potential from buried subsurface charged defects in the ferroelectric materials with a nanometer-scale spatial resolution. When compared with the composition-sensitive methods, such as neutron diffraction, X-ray photoelectron spectroscopy, and local time-of-flight secondary ion mass spectrometry, the SSPFM sensitivity to the variation of the electric potential from the charged defects is shown to be equivalent to less than 0.3 at% of the defect concentration. Additionally, the possibility to locally evaluate dynamics of the polarization screening caused by the charged defects is demonstrated, which is of significant interest for further understanding defect-mediated processes in ferroelectrics.

42 ENGINEERING↗

Status Report on Design of In-situ Thermomechanical Testing at LANSCE

Nuclear fuel encounters severe thermomechanical environments in which its mechanical response is determined by its microstructure, temperature and stress level histories. Simulating the response of such microstructures is crucial for predicting both performance and transient fuel mechanical responses and experimental verification of such predictions is therefore of great interest. While most of the deformation in a nuclear fuel rod occurs in the cladding, deformation of the fuel itself is still of interest with deformation mechanisms at operating temperature and above including creep, swelling, cracking as well as pellet-clad interaction. Characterization of these properties and understanding of the underlying deformation phenomena at operating or excursion temperatures is therefore of great importance for development and ultimately licensing of improved and novel nuclear fuel forms. Diffraction techniques offer unique insight on the atomistic (e.g. crystal structure) and microstructure (e.g. phase transformations, texture, defects) length scales and have a long history of providing unique data to inform relevant deformation models that enable the required predictive capabilities. For example, dislocations lead to diffraction peak broadening that can be characterized to estimate the dislocation density and study the role of dislocations on the deformation while measuring lattice strains allows to studie load sharing in two phase materials. In this report the requirements for a sample environment for high temperature deformation of nuclear fuels are defined. The HIPPO neutron time-of-flight diffractometer at LANSCE will host this sample environment and is also described. This instrument covers diffraction angles from 140° to 40° and is also equipped with an event-mode neutron imaging detector system, enabling energy-resolved neutron imaging in parallel with the diffraction that could measure sample temperature from Doppler broadening of neutron absorption resonances or measure pore densities from changes in the attenuation. Designs of devices to characterize thermomechanical properties of nuclear fuel without diffraction are also considered to guide the design. While this report is focused on applications for nuclear fuels, the device can also characterize cladding, moderator or structural materials and therefore contribute to other fields of research and development for advanced reactors. The temperatures planned to be reached are above 2000℃, thus enabling characterization of LWR reactor fuels under accident scenarios but also reaching temperatures of fuels developed for nuclear thermal propulsion and providing opportunities to characterize those. In conjunction with the energy-resolved neutron imaging detector, this setup would allow to measure neutron cross-sections at high temperatures, filling a gap towards development of reactors operating at high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

GSAS-II (GENERAL STRUCTURE AND ALAYSIS SYSTEM-II)

GSAS-II is a comprehensive data analysis and simulation software package for determining atomistic structures from single-crystal and powder diffraction data. X-ray, neutron and electron data may be used. Constant-wavelength, time-of-flight and pink-beam sources may be employed and analyses may combine different types of data. The package is oriented towards materials characterization problems, but protein crystallography, pair-distribution function analysis, small-angle scattering and reflectometry analysis are all included. GSAS-II provides tools for indexing and solving structures from powder diffraction data, in addition to structure, data and results visualization tools

TOBY, BRIANH↗

Texture measurements on quartz single crystals to validate coordinate systems for neutron time-of-flight texture analysis

In crystallographic texture analysis, ensuring that sample directions are preserved from experiment to the resulting orientation distribution is crucial to obtain physical meaning from diffraction data. This work details a procedure to ensure instrument and sample coordinates are consistent when analyzing diffraction data with a Rietveld refinement using the texture analysis software MAUD . A quartz crystal is measured on the HIPPO diffractometer at Los Alamos National Laboratory for this purpose. The methods described here can be applied to any diffraction instrument measuring orientation distributions in polycrystalline materials.

36 MATERIALS SCIENCE↗

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

High-Temperature Neutron Diffraction Study of Vanadium and Vanadium–Niobium Null-Matrix Alloy for Spectrum Normalization

This study systematically evaluates a vanadium–niobium (V 94.1 Nb 5.9 ) null-matrix alloy as a reference material for neutron spectrum normalization and compares its performance with that of pure vanadium under identical experimental conditions. Neutron diffraction experiments are conducted on the VULCAN Engineering Materials Diffractometer at the Spallation Neutron Source, Oak Ridge National Laboratory, over a temperature range from room temperature to 1200 °C under vacuum. Pure vanadium exhibited distinct Bragg peaks across all temperatures, with its diffraction behavior influenced by both sample orientation and temperature. As the temperature increased, the diffraction peaks shifted to larger d-spacings and decreased in intensity, while spectral deviation near d ≈ 2.8 Å exceeded 10% at 1200 °C. In contrast, the V–Nb alloy produced a nearly featureless spectrum over the full d-spacing range, confirming near-complete cancellation of coherent scattering over the wide temperature range. Its spectra were insensitive to sample orientation, temperature, and microstructural evolution, with spectral deviation around d ≈ 2.8 Å exceeded 5% at 1200 °C. In conclusion, these results demonstrate that the V–Nb null-matrix alloy provides a thermally stable, efficient, and reliable normalization standard for time-of-flight diffractometers or other instrument where it is needed, enabling reduced data acquisition time and improved data quality in high-temperature neutron diffraction experiments.

Alloys↗

BERT Non-Destructively Probes the Microstructure of Dissimilar Welds [Poster]

Energy-resolved neutron imaging (ERNI) utilizes contrast provided by diffraction. Microstructure with >100µm grains as in cast, annealed or welded materials is difficult to characterize by X-ray or electron-based methods $\Rightarrow$ Well-suited for neutron Bragg-edge radiography. BERT was applied to dissimilar welds of Inconel on steel produced by additive manufacturing. Viewing the sample at time-of-flight/energy/wavelength where a single grain orientation dominates the attenuation allows to map grain orientations. Similarly to electron-backscatter diffraction (EBSD) but on cm length scales and through-thickness. Combined with texture measurements on the HIPPO instrument, identifying major grain orientations, 2D and 3D grain orientation maps are feasible. Results can guide development of thermo-mechanical treatment avoiding or introducing such microstructures, characterize dissimilar welds, interpretation of acoustic signals for quality control, guide destructive examination with X-rays/electrons, or provide data for codes predicting such microstructures.

36 MATERIALS SCIENCE↗

Second Target Station (STS) Project: PIONEER Technical Report

PIONEER is a time-of-flight single-crystal neutron diffractometer at the Second Target Station (STS), aiming at providing the world-leading capability to measure tiny crystals (~0.001 mm 3 , i.e., X-ray diffraction size), ultra-thin epitaxial films (~10 nm thicknesses), and weak structural transitions and complex magnetism. The instrument will take advantage of STS source characteristics and utilize advancements in neutron optics to largely reduce the sample-volume requirement for single-crystal neutron diffraction. PIONEER will have a high-flux mode with multiple beam size options to improve the signal-to-background ratio in various sample environments. It will also provide a high Q-resolution mode by limiting beam divergence to study periodically modulated structures with characteristic lengths no less than 100 Å. Furthermore, it supports half-polarized neutron diffraction for investigating complex magnetism and local susceptibility. This report first overviews the proposed science case and the derived requirement. And then, the chosen technical solutions and expected performance will be described.

36 MATERIALS SCIENCE↗

M-STAR: Magnetism second target advanced reflectometer at the Spallation Neutron Source

M-STAR is a next generation polarized neutron reflectometer with advanced capabilities. A new focusing guide concept is optimized for samples with dimensions down to a millimeter range. A proposed hybrid pulse-skipping chopper will enable experiments at constant geometry at one incident angle in a broad range of wavevector transfer Q up to 0.3 A –1 for specular, off-specular, and GISANS measurements. M-STAR will empower nanoscience and spintronics studies routinely on small samples (~2 × 2 mm 2 ) and of atomic-scale thickness using versatile experimental conditions of magnetic and/or electric fields, light, and temperature applied in situ to novel complex device-like nanosystems with multiple buried interfaces. M-STAR will enable improved grazing incidence diffraction measurements, as a surface-sensitive depth-resolved probe of, e.g., the out-of-plane component of atomic magnetic moments in ferromagnetic, antiferromagnetic, and more complex structures as well as in-plane atomic-scale structures inaccessible with contemporary diffractometry and reflectometry. New horizons will be opened by the development of an option to probe near-surface dynamics with inelastic grazing incidence scattering in the time-of-flight mode. These novel options in combination with ideally matched parameters of the second target station will place M-STAR in the world’s leading position for high resolution polarized reflectometry.

47 OTHER INSTRUMENTATION↗

Thermodynamics, local structure, and transport of protons in triple-conducing oxide, BaCo 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3-δ (BCFZY4411)

Triple-conducting oxides (TCOs) are an emerging class of mixed ionic and electronically conducting materials that show great promise for oxygen reduction/oxygen evolution (ORR/OER) electrocatalysis—primarily in high-temperature ceramic electrochemical cells— but also in aqueous alkaline environments. Their high activity is attributed, at least in part, to their ability to incorporate and transport three mobile charge carriers: protons, oxygen vacancies, and electron-holes Despite their promise, fundamental studies of TCOs are challenging, as transport dynamics from three charge carriers cannot be fully disentangled via traditional electrical measurement techniques. Characterizing proton dynamics in TCOs is particularly difficult as protons are generally the minority carrier, and their conduction response is typically obscured by the oxygen vacancies and electron holes. Here, we demonstrate successful isolation of the proton behavior in an archetypal TCO, BaCo 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3-δ (BCFZY4411), using a combination of non-electrical techniques. We determine proton uptake and oxygen non-stoichiometry (δ) using thermogravimetric analysis (TGA). X-ray absorption near edge structure (XANES) and neutron diffraction (ND) are used to validate the oxidation state of Co and the δ values obtained through TGA. We apply 1H solid-state magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) to provide insights into local structure, dynamics, and proton kinetics. Finally, the proton transport properties are further quantified using tracer isotope exchange with time-of-flight secondary ion mass spectrometry (ToF-SIMS). Despite the very low proton concentrations in BCFZY4411 (<0.2% under most conditions), our analysis suggests that the oxygen Manuscript File Click here to view linked References 2 reduction and evolution reactions are nevertheless limited by the oxygen ion kinetics (e.g., oxygen surface exchange) rather than the proton kinetics at the reduced operating temperatures (<500 °C) that are targeted for electrochemical cell applications. These findings provide a comprehensive understanding of proton behavior in BCFZY4411 and pave the way for advancing the fundamental study of TCOs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detector pixel calibration of time-of-flight neutron diffractometers accelerated by machine learning

Modern time-of-flight neutron diffractometers at spallation neutron source are equipped with two dimensional detectors with fine pixelations. The flight path of neutrons from the moderator to the sample and to the detector needs to be precisely calibrated at detector pixel level using standard powders so the diffraction data from all the detector pixels can be correctly time-focused to produce high resolution diffraction peaks. The number of pixels can reach to millions which makes a single-pixel calibration process time-consuming, or even impossible, with conventional fitting routine. Here we presented a machine learning aided calibration process via a “training and predict” process by training machine learning models with the relations between the individual pixel time-of-flight diffraction pattern and fitted diffraction constant. The training models take a portion of the available pixels to predict the diffraction constants precisely and rapidly for massive pixel diffraction patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗