Search NASA⌕ Search

SEARCH · Search NASA

Results for “Title”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Environmental Baseline Survey Report for the Title Transfer of Land Parcel ED-4 at the East Tennessee Technology Park, Oak Ridge, Tennessee

This environmental baseline survey (EBS) report documents the baseline environmental conditions of a land parcel referred to as 'ED-4' (ED-4) at the U. S. Department of Energy's (DOE's) East Tennessee Technology Park (ETTP). DOE is proposing to transfer the title of this land to the Heritage Center, LLC. Parcel ED-4 is a land parcel that consists of two noncontiguous areas comprising a total of approximately 18 acres located east of the ETTP. The western tract of ED-4 encompasses approximately 8.5 acres in the northeastern quadrant of the intersection of Boulevard Road and Highway 58. The eastern tract encompasses an area of approximately 9.5 acres in the northwestern quadrant of the intersection of Blair Road and Highway 58 (the Oak Ridge Turnpike). Aerial photographs and site maps from throughout the history of the ETTP, going back to its initial development in the 1940s as the Oak Ridge Gaseous Diffusion Plant (ORGDP), indicate that this area has been undeveloped woodland with the exception of three support facilities for workers constructing the ORGDP since federal acquisition in 1943. These three support facilities, which were located in the western tract of ED-4, included a recreation hall, the Town Hall Camp Operations Building, and the Property Warehouse. A railroad spur also formerly occupied a portion of Parcel ED-4. These former facilities only occupied approximately 5 percent of the total area of Parcel ED-4. This report provides supporting information for the transfer of this government-owned property at ETTP to a non-federal entity. This EBS is based upon the requirements of Sect. 120(h) of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). In order to support a Clean Parcel Determination (CPD) in accordance with CERCLA Sect. 120(h)(4)(d), groundwater and sediment samples were collected within, and adjacent to, the Parcel ED-4 study area. The potential for DOE to make a CPD for ED-4 is further supported by a No Further Investigation (NFI) determination made on land that adjoins ED-4 to the east (DOE 1997a) and to the south (DOE 1997b).

54 ENVIRONMENTAL SCIENCES↗

Dataset for the paper titled "Investigating the relationship between bolide entry angle and apparent direction of infrasound signal arrivals"

This dataset includes outputs generated for the journal publication titled: "Investigating the relationship between bolide entry angle and apparent direction of infrasound signal arrivals". The outputs include .csv files with model-generated synthetic trajectories of asteroids entering Earth at a variety of impact and approach (azimuthal) angles. All outputs are based on hypothetical but realistic scenarios.

Herrera, Natalie [Sandia National Laboratories (SN↗

Data-model files associated with the manuscript titled "The Importance of Explicitly Representing the Streambed in Watershed Models" (Shuai et al., 2023 HP)

This data package contains the model inputs and outputs used in the manuscript titled "The Importance of Explicitly Representing the Streambed in Watershed Models" (Shuai et al., 2023 HP). The data.zip file contains the data used to drive the Advanced Terrestrial Simulator (ATS) model simulations. The model.zip file contains the XML input file for ATS. The notebook.zip file contains the Jupyter notebooks for pre- and post- processing model results. The figures.zip file contains the raw figures associated with the manuscript. We generated this data package in support of the manuscript and research reproducibility. The background of this study is that the streambed itself has not been explicitly represented in watershed models, although the streambed characteristics are significantly different from those of its surrounding soil. We aim to answer the following questions: 1) How do streambed properties including hydraulic conductivity, thickness and resolution impact the groundwater-surface water exchange fluxes across the streambed? 2) Is an explicit representation of streambed important in watershed modeling?; 3) Is a high-resolution streambed needed for watershed simulations?

54 ENVIRONMENTAL SCIENCES↗

Data supporting the article titled "Heterogeneous Multiphase Flow Properties of Volcanic Rocks and Implications for Noble Gas Transport from Underground Nuclear Explosions"

The submission is a Reproducible Research (RR) data archive that contains the supporting multiphase fluid flow and curve fitting results of the Vadose Zone Journal article titled: "Heterogeneous Multiphase Flow Properties of Volcanic Rocks and Implications for Noble Gas Transport from Underground Nuclear Explosions." The article's DOI number is the following: https://doi.org/10.1002/vzj2.20123. Please see the "Methods and Materials" section of the journal article and the ReadMe.txt in the RR_ARCHIVE folder for further details. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND Number: SAND2021-3407 O.

mercury injection capillary pressure↗

2015 Uranium Mill Tailings Radiation Control Act (UMTRCA) Title ll Annual Report, L-Bar, New Mexico Disposal Site

The L-Bar, New Mexico, Uranium Mill Tailings Radiation Control Act (UMTRCA) Title II Disposal Site was inspected on August 18, 2015. The tailings impoundment was in excellent condition. Erosion and vegetation measurements to monitor the condition of the impoundment cover indicated that no erosion is occurring, and perennial vegetation foliar cover at the measurement plots increased substantially compared to previous years due to above-average precipitation for the year. A short segment of the perimeter fence near the site entrance was realigned in spring 2015 because a gully was undermining the fence corner. Loose fence strands at another location were repaired during the inspection, and a section of fence needs to be realigned to avoid areas affected by deep gullies and sediment deposition. Inspectors identified no other maintenance needs or cause for a follow-up inspection. Groundwater monitoring is required every 3 years. The next monitoring event will be in 2016.

54 ENVIRONMENTAL SCIENCES↗

Control of Interface- and Mesoscopic Structure in High Performance Organic Solar Cells: Towards a Predictive Device Paradigm [and earlier project titles]. Final Technical Report for DE-FG02-98ER45737

This document represents the cumulative, final technical report for Grant No. DE-FG02-98ER45737, the title of which has changed with each funding period, but the research pursued is within a coherent overall theme of methods and technique developments that exploit contrast at the carbon absorption edge to characterize complex organic materials and the use of these synchrotron radiation-based methods for important research challenges in polymer physics and Materials Science. The last three funding periods focused on organic devices and in particular organic solar cells (OSCs), owing to their extra-ordinarily complex morphology, yet high potential as a cheap and printable power-conversion technology.

14 SOLAR ENERGY↗

Final report of activities for the LDRD-express project #223796 titled: “Fluid models of charged species transport: numerical methods with mathematically guaranteed properties”, PI: Ignacio Tomas, Co-PI: John Shadid

This report summarizes the findings and outcomes of the LDRD-express project with title “Fluid models of charged species transport: numerical methods with mathematically guaranteed properties”. The primary motivation of this project was the computational/mathematical exploration of the ideas advanced aiming to improve the state-of-the-art on numerical methods for the one-fluid Euler-Poisson models and gain some understanding on the Euler-Maxwell model. Euler-Poisson and Euler-Maxwell, by themselves are not the most technically relevant PDE plasma-models. However, both of them are elementary building blocks of PDE-models used in actual technical applications and include most (if not all) of their mathematical difficulties. Outside the classical ideal MHD models, rigorous mathematical and numerical understanding of one-fluid models is still a quite undeveloped research area, and the treatment/understanding of boundary conditions is minimal (borderline non-existent) at this point in time. This report focuses primarily on bulk-behaviour of Euler-Poisson’s model, touching boundary conditions only tangentially.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Standardized Protocol for Real-Time APIs as Required by Title 23 CFR 680.116(c)

Improving the ability of drivers to easily locate working and available chargers is key to improving the public charging experience. Electric vehicle charging providers who are recipients of federal funds through the National Electric Vehicle Infrastructure (NEVI) Formula Program, Charging and Fueling Infrastructure (CFI) Discretionary Grant Program, and other funding programs as identified under Title 23 of the U.S. Code must deploy and maintain an application programming interface (API) to access information about charging stations they operate.1 This includes information about individual charging ports, pricing, and availability in accordance with the Federal Highway Administration’s National Electric Vehicle Infrastructure Standards and Requirements, 23 CFR 680.116(c), herein referred to as the minimum standards (Federal Highway Administration 2023). Specifically outlined in the minimum standards, states and other designated recipients are required to ensure that charging station information including location, connector type, power level, real-time status, and real-time price to charge are available free of charge to third-party software developers through an API. These requirements are intended to enable effective communication with consumers about available charging stations and help consumers make informed decisions about trip planning, including when and where to charge. This document provides a standardized protocol for how to structure data, data update frequency, and practices for making the data required to be shared via API usable for improving public transparency and the customer experience. These are recommendations only and do not modify the Federal Highway Administration’s minimum standards in any way.

33 ADVANCED PROPULSION SYSTEMS↗

Recommended Changes to Specifications for Demand Controlled Ventilation in California's Title 24 Building Energy Efficiency Standards

In demand-controlled ventilation (DCV), rates of outdoor air ventilation are automatically modulated as occupant density varies. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. DCV is most often used in spaces with highly variable and sometime dense occupancy. In almost all cases, carbon dioxide (CO{sub 2}) sensors installed in buildings provide the signal to the ventilation rate control system. People produce and exhale CO{sub 2} as a consequence of their normal metabolic processes; thus, the concentrations of CO{sub 2} inside occupied buildings are higher than the concentrations of CO{sub 2} in the outdoor air. The magnitude of the indoor-outdoor CO{sub 2} concentration difference decreases as the building's ventilation rate per person increases. The difference between the indoor and outdoor CO{sub 2} concentration is also a proxy for the indoor concentrations of other occupant-generated bioeffluents, such as body odors. Reviews of the research literature on DCV indicate a significant potential for energy savings, particularly in buildings or spaces with a high and variable occupancy. Based on modeling, cooling energy savings from applications of DCV are as high as 20%. With support from the California Energy Commission and the U.S. Department of Energy, the Lawrence Berkeley National Laboratory has performed research on the performance of CO{sub 2} sensing technologies and optical people counters for DCV. In addition, modeling was performed to evaluate the potential energy savings and cost effectiveness of using DCV in general office spaces within the range of California climates. The above-described research has implications for the specifications pertaining to DCV in section 121 of the California Title 24 Standard. Consequently, this document suggests possible changes in these specifications based on the research findings. The suggested changes in specifications were developed in consultation with staff from the Iowa Energy Center who evaluated the accuracy of new CO{sub 2} sensors in laboratory-based research. In addition, staff of the California Energy Commission, and their consultants in the area of DCV, provided input for the suggested changes in specifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data supporting manuscript from L. Sheneman, G. Stephanopoulos, A.E. Vasdekis titled "Deep learning classification of lipid droplets in quantitative phase images" as currently under review at PLOS ONE. This includes: 1) raw and binary labeled Quantitative Phase Images (QPI) of Y. lipolytica cells used in the analyses described within the manuscript. 2) various derived data including classifier scores, etc.

Data supporting manuscript from L. Sheneman, G. Stephanopoulos, A.E. Vasdekis titled "Deep learning classification of lipid droplets in quantitative phase images" as currently under review at PLOS ONE. This includes: 1) raw and binary labeled Quantitative Phase Images (QPI) of Y. lipolytica cells used in the analyses described within the manuscript. 2) various derived data including classifier scores, etc.

ANN↗

National Research Council Dialogue to Assess Progress on NASA's Title of CRM Capability Roadmap Development: General Background and Introduction

Contents include the following: General Background and Introduction of Capability Roadmaps "Title." Agency Objective. Strategic Planning Transformation. Advanced Planning Organizational Roles. Public Involvement in Strategic Planning. Strategic Roadmaps and Schedule. Capability Roadmaps and Schedule. Purpose of NRC Review. Capability Roadmap Development (Progress to Date).

Crooke, Julie A.↗

A Title 40 Code of Federal Regulations Part 191 Evaluation of Buried Transuranic Waste at the Nevada Test Site

In 1986, 21 m{sup 3} of transuranic (TRU) waste was inadvertently buried in a shallow land burial trench at the Area 5 Radioactive Waste Management Site on the Nevada Test Site (NTS). The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office is considered five options for management of the buried TRU waste. One option is to leave the waste in-place if the disposal can meet the requirements of Title 40 Code of Federal Regulations (CFR) Part 191, 'Environmental Radiation Protection Standard for Management and Disposal of Spent Nuclear Fuel, High-Level, and Transuranic Radioactive Wastes'. This paper describes analyses that assess the likelihood that TRU waste in shallow land burial can meet the 40 CFR 191 standards for a geologic repository. The simulated probability of the cumulative release exceeding 1 and 10 times the 40 CFR 191.13 containment requirements is estimated to be 0.009 and less than 0.0001, respectively. The cumulative release is most sensitive to the number of groundwater withdrawal wells drilled through the disposal trench. The mean total effective dose equivalent for a member of the public is estimated to reach a maximum of 0.014 milli-Sievert (mSv) at 10,000 years, or approximately 10 percent of the 0.15 mSv 40 CFR 191.15 individual protection requirement. The dose is predominantly from inhalation of short-lived Rn-222 progeny in air produced by low-level waste disposed in the same trench. The transuranic radionuclide released in greatest amounts, Pu-239, contributes only 0.4 percent of the dose. The member of public dose is most sensitive to the U-234 inventory and the radon emanation coefficient. Reasonable assurance of compliance with the Subpart C groundwater protection standard is provided by site characterization data and hydrologic processes modeling which support a conclusion of no groundwater pathway within 10,000 years. Limited quantities of transuranic waste in a shallow land burial trench at the NTS can meet the requirements of 40 CFR 191. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Title 40 Code of Federal Regulations Part 191 Evaluation of Buried Transuranic Waste at the Nevada Test Site

In 1986, 21 m{sup 3} of transuranic (TRU) waste was inadvertently buried in a shallow land burial trench at the Area 5 Radioactive Waste Management Site on the Nevada Test Site (NTS). The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office is considered five options for management of the buried TRU waste. One option is to leave the waste in-place if the disposal can meet the requirements of Title 40 Code of Federal Regulations (CFR) Part 191, 'Environmental Radiation Protection Standard for Management and Disposal of Spent Nuclear Fuel, High-Level, and Transuranic Radioactive Wastes'. This paper describes analyses that assess the likelihood that TRU waste in shallow land burial can meet the 40 CFR 191 standards for a geologic repository. The simulated probability of the cumulative release exceeding 1 and 10 times the 40 CFR 191.13 containment requirements is estimated to be 0.009 and less than 0.0001, respectively. The cumulative release is most sensitive to the number of groundwater withdrawal wells drilled through the disposal trench. The mean total effective dose equivalent for a member of the public is estimated to reach a maximum of 0.014 milliSievert (mSv) at 10,000 years, or approximately 10 percent of the 0.15 mSv 40 CFR 191.15 individual protection requirement. The dose is predominantly from inhalation of short-lived Rn-222 progeny in air produced by low-level waste disposed in the same trench. The transuranic radionuclide released in greatest amounts, Pu-239, contributes only 0.4 percent of the dose. The member of public dose is most sensitive to the U-234 inventory and the radon emanation coefficient. Reasonable assurance of compliance with the Subpart C groundwater protection standard is provided by site characterization data and hydrologic processes modeling which support a conclusion of no groundwater pathway within 10,000 years. Limited quantities of transuranic waste in a shallow land burial trench at the NTS can meet the requirements of 40 CFR 191.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗