A Novel Solid Electrolyte Oxygen Sensor System for In-Situ Measurement and Process Control
In 1993 the oxygen partial pressure was firstly measured inside a plasma wind tunnel using conventional {lambda}-probes. Since then, a considerable amount of knowledge has been gained in using these sensors in ground test facilities and space. However, these commercially available sensors were too large in scale and weight. Consequently, a new development of solid electrolyte sensors called FIPEX more feasible for space was initiated. Due to space driven benefits, interest arose to use FIPEX technique in terrestrial applications e.g. to monitor sputter plants for float glass coating. Therefore, the VacuSen registered sensor was developed. The characterization of VacuSen registered at nominal sensor temperature T{sub S} = 680 deg. C resulted in a sensor current according to I{sub S} = b{center_dot}p{sub O2}{sup 0{center_dot}8{+-}0{center_dot}05} I[{mu}A] in the operation range between p{sub tot} = 1{center_dot}10{sup -3} to 5 Pa. From pulse width modulation (PWM) temperature control, additional information allows to measure ptot according to p{sub tot} = a{center_dot}RPWM{sup 0{center_dot}107{+-}0{center_dot}005} thus enlarging the operation range to p{sub tot} = 1{center_dot}10{sup -3} to 1{center_dot}10{sup 5} Pa. A one point calibration routine with air, ideally at p{sub tot} = 5 Pa in order to determine both calibration parameters a and b simultaneously, is proposed.