Search NASA⌕ Search

SEARCH · Search NASA

Results for “Torsional Spring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance Testing of an Integrated Magnetic Power Take-Off

A wave energy converter (WEC) and the power take-off (PTO) generator system can be represented by using a mass-spring-dampener model. By incorporating a negative stiffness spring within the PTO, the overall stiffness of the PTO can be lowered allowing the impedance of the PTO to be more closely matched with the WEC. By designing for impedance matching the WEC can greatly enhance its power generation capability. This project has involved the design, fabrication and testing of a new type of linear-stroke length and rotary stroke length adjustable negative stiffness magnetic springs for use within a wave energy converter (WEC). The magnetic springs were studied by using 3-D finite element analysis with the objective of creating high energy density and a long linear stroke length. After the construction and testing of both a proof-of-principle adjustable linear and rotary magnetic spring prototype the rotary (torsional) magnetic spring was selected for scaling up analysis. The selected scaled-up proof-of-principle magnetic spring had a peak torque of 850 Nm with a ±45 degree stroke length. By translating the inner rotor relative to the outer rotor, the stiffness could be adjusted to be either negative or positive stiffness. During this project a magnetic lead screw was also studied, and it was shown that by combining the magnetic lead screw with a linearly translating magnetic spring a very long rotary stroke length could be attained. However, as the magnetic lead screw increased complexity and reduced overall energy density relative to a rotary (torsional) spring, this design approach was not further pursed. Dynamometer testing of the variable stiffness magnetic springs was first completed by Portland State University and following this the magnetic spring performance was independently verified by Sandia National Laboratory (Sandia). A WEC analysis when using a variable stiffness magnetic spring was completed by using the WecOptTool. WecOptTool is an open-source WEC optimization software developed by Sandia that supports efficient power take-off (PTO) and control optimization. Wave condition data from the Oregon PacWave test-site was used in this study. The analysis showed that a WEC with a tunable stiffness value could consistently achieve about 80% of its maximum theoretical power production. The use of a tunable stiffness WEC, rather than zero-stiffness or a constant stiffness WEC was also shown to lead to a smaller maximum PTO force requirement. The variable stiffness magnetic spring was integrated into an experimental WEC developed by Sandia, called a Wave-Bot. Sandia successfully completed water-tank testing of the Wave-Bot at the Navy’s Carderock, Maryland, wave-basin test site. The wave-basin testing helped to experimentally demonstrate the operating capabilities and increased power generation capability of a WEC containing an integrated variable stiffness magnetic spring. A WEC capacity factor analysis was also completed. The capacity factor was defined as the ratio of annual average WEC generator power to the maximum (RMS) generated power. This capacity factor provided a means of identifying the ratio of potential revenue to cost. It was calculated that if a tunable variable stiffness magnetic spring has RMS constraints it could operate with a capacity factor above 30%. This is comparable to a wind turbine’s capacity factor.

16 TIDAL AND WAVE POWER↗

Bellows joint absorbs torsional deflections in duct system

Long, thin-walled bellows compressed into a short length absorbs the same amount of torsional deflection as the same tube in full length condition and saves in cost, complexity and space. This bellows has lower torsional spring rate to absorb the bulk of the duct assembly tortional deflections, leaving the other bellows free to absorb axial and angular deflections.

Daniels, C. M.↗

Model support roll balance and roll coupling

The design concepts of two specialized wind tunnel model support mechanisms are described. The forced oscillation roll balance mechanism was designed to meet the specific requirement to measure aerodynamic forces and moments to permit determination of the damping-in-roll parameters of winged configurations. A variable speed motor is used to oscillate the model by means of an offset crank. The oscillating motion is resisted by a torsion spring to provide a restoring torque and is attached to the section forward of the strain-gage balance. This spring action allows the model to be oscillated at a frequency for velocity resonance, whereby the mechanical spring and any aerodynamic spring balance. This spring action allows the model to be oscillated at a frequency for velocity resonance, whereby the mechanical spring and any aerodynamic spring balance out the model inertia. The only torque then required to oscillate the model at that particular frequency is equal to that due to aerodynamic damping. The second mechanism, a roll coupling for remotely rotating a model, was designed to invert or roll a model about its longitudinal axis when mounted for testing.

Sharpes, R. E.↗

Flutter analysis of two parallel elastically coupled flat plates

Flutter of two parallel elastically coupled flat plates was investigated analytically. A closed-form solution including both aerodynamic and structural damping is presented for flutter of flat orthotropic plates coupled by an elastic medium. Both plates are simply supported along the side edges but are supported by deflectional, rotational, and torsional springs of arbitrary stiffness at the leading and trailing edges. Two-dimensional quasi-steady aerodynamics was utilized in the solution. Since the large number of variables present in the problem precludes extensive parametric studies, results are presented to indicate the basic flutter characteristics of coupled two-plate systems and to assess the validity of previously published modal solutions for similar problems.

Shore, C. P.↗

Development of the space shuttle body flap actuation subsystem

Development of the Body Flap Actuation Subsystem for Space Shuttles included alterations from the original design to mechanical stops, planet gears, control valves, and solenoid valves. The mechanical stops were redesigned to absorb stall load and rotating inertia of the hydraulic motors instead of only stall load. The institution of a quill shaft (torsion spring) was a successful solution. The planet gears in the geared rotary actuators developed cracks during testing. This failure was alleviated via modification to the gears. A motor pressurization - brake release timing technique was developed thru analysis and testing. This resulted in a control valve configuration which would not permit freewheeling of the body flap surface. Finally, several solenoid valve configurations were tested to obtain the desired performance. Conceptual redesigns and modifications were weighted against each other to optimize a solution. Tradeoffs were usually made between life, performance, failure tolerance, and reliability versus weight, envelope, and maintainability.

Boggs, C. R.↗

A three-dimensional adaptive grid method

A three-dimensional solution-adaptive-grid scheme is described which is suitable for complex fluid flows. This method, using tension and torsion spring analogies, was previously developed and successfully applied for two-dimensional flows. In the present work, a collection of three-dimensional flow fields are used to demonstrate the feasibility and versatility of this concept to include an added dimension. Flow fields considered include: (1) supersonic flow past an aerodynamic afterbody with a propulsive jet at incidence to the free stream, (2) supersonic flow past a blunt fin mounted on a solid wall, and (3) supersonic flow over a bump. In addition to generating three-dimensional solution-adapted grids, the method can also be used effectively as an initial grid generator. The utility of the method lies in: (1) optimum distribution of discrete grid points, (2) improvement of accuracy, (3) improved computational efficiency, (4) minimization of data base sizes, and (5) simplified three-dimensional grid generation.

Nakahashi, K.↗

Synchronously Deployable Truss Structures

Structure lightweight, readily deployed, and has reliable joints. New truss concept, designated as "pac truss," developed. Features easy deployment without need for complex mechanisms. Structures of this type deployed in free flight by controlled release of stored energy in torsional springs at selected hinges located throughout structure. Double-folding technique used in beam model applicable to flat planar trusses, allowing structures of large expanse to fold into compact packages and be deployed for space-platform applications.

Rhodes, M. D.↗

Structural optimization of thin shells using finite element method

The objective of the present work was the structural optimization of thin shell structures that are subjected to stress and displacement constraints. In order to accomplish this, the structural optimization computer program DESAP1 was modified and improved. In the static analysis part of the DESAP1 computer program the torsional spring elements, which are used to analyze thin, shallow shell structures, were eliminated by modifying the membrane stiffness matrix of the triangular elements in the local coordinate system and adding a fictitious rotational stiffness matrix. This simplified the DESAP1 program input, improved the accuracy of the analysis, and saved computation time. In the optimization part of the DESAP1 program the stress ratio formula, which redesigns the thickness of each finite element of the structure, was solved by an analytical method. This scheme replaced the iterative solution that was previously used in the DESAP1 program, thus increasing the accuracy and speed of the design. The modified program was used to design a thin, cylindrical shell structure with optimum weight, and the results are reported in this paper.

Gotsis, Pascal K.↗

Space marching calculations about hypersonic configurations using a solution-adaptive mesh algorithm

A solution-adaptive marching algorithm is developed and applied to a three-dimensional parabolized Navier-Stokes equation solver. The resulting algorithm obtains accurate solutions by using a spatial-marching/adaptive grid procedure. The adaptation step redistributes grid points line by line in both crossflow directions, with grid point motion controlled by forces analogous to tensional and torsional spring forces with the tensional force proportional to the error measure or weighting functions. The solution-adaptive marching procedure is applied to the hypersonic flow about two generic aircraft configurations. The first of these is an all-body-type geometry with elliptical cross sections and is studied at angles of attack of 0.5, and 15 deg. The second geometry is a generic blended-wing-body design. Results are presented that demonstrate the improvements in flowfield resolution obtainable with the solution-adaptive marching procedure over conventional fixed grid techniques. Computed pitot pressure profiles obtained using the solution-adaptive algorithm show improved agreement with experimental data compared to predictions obtained using a fixed grid.

Harvey, Albert D.↗

Nonhydrodynamic Characteristics of the Oscillating Screen Viscometer

Extraction of the viscosity from the oscillating screen's response function requires knowledge of it resonance frequency omega(sub 0) and of the prefactor k(sub tr)/k(theta), where k(sub tr) is a transducer coefficient and k(sub theta) is the torsion spring constant. The determination of these parameters is described. The effect of a possible anomaly in the dielectric constant near the critical point of xenon will be negligible.

Berg, Robert F.↗

Particle Characterization in Rocket Exhaust Plumes

A method to characterize particles in rocket exhaust plumes is developed. The particle velocity, size, and material composition are determined from crater characteristics resulting from impacts into aluminum and copper targets passed through the plume. The targets are mounted on a steel arm approximately 21 inches (53 cm) long which is rotated through the plume at sufficient velocity to prevent material failure resulting from thermal effects. A Scanning Electron Microscope (SEM) with secondary x-ray detectors is used to determine the particle material, and a standard optical measurement microscope is used to determine the crater diameter and depth. The crater diameter and depth are used in turn, as inputs to a ballistics computer code to estimate the velocity and size of the particle. The target has a safe residence time in the plume of approximately 50 ms before reaching an unacceptably high temperature. The = must mach a velocity of 104 ft/s (32 m/s) before entering the plume to produce the design residence time of 20 ms. The arm is actuated by a torsion spring with a 5-inch (13 cm) outer diameter, 0.625-inch (16 mm wire diameter, and 11 coils. A prototype of the entire rocket exhaust particle impact characterization system (PICS) was constructed and statically tested.

Callen, E. Eugene, Jr.↗

Thrust Stand for Vertically Oriented Electric Propulsion Performance Evaluation

A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally-stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A non-contact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational restoring force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN-level thrusts, while those tests conducted on 200 lbm thruster yielded a resolution of roughly 2.5 micro at thrust levels of 0.5 N and greater.

Moeller, Trevor↗

Simulation System for Training in Laparoscopic Surgery

A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set up to simulate the insertion of a flexible catheter in a bile duct. [As thus configured, the system can also be used to simulate other endoscopic procedures (e.g., bronchoscopy and colonoscopy) that include the insertion of flexible tubes into flexible ducts.] A hybrid approach has been followed in developing the software for real-time simulation of the visual and haptic interactions (1) between forceps and the catheter, (2) between the forceps and the duct, and (3) between the catheter and the duct. The deformations of the duct are simulated by finite-element and modalanalysis procedures, using only the most significant vibration modes of the duct for computing deformations and interaction forces. The catheter is modeled as a set of virtual particles uniformly distributed along the center line of the catheter and connected to each other via linear and torsional springs and damping elements. The interactions between the forceps and the duct as well as the catheter are simulated by use of a ray-based haptic-interaction- simulating technique in which the forceps are modeled as connected line segments.

Basdogan, Cagatay↗

Design and Test of a Deployable Radiation Cover for the REgolith X-Ray Imaging Spectrometer

The REgolith X-ray Imaging Spectrometer (REXIS) instrument contains a one-time deployable radiation cover that is opened using a shape memory alloy actuator (a "Frangibolt") from TiNi Aerospace and two torsion springs. The door will be held closed by the bolt for several years in cold storage during travel to the target asteroid, Bennu, and it is imperative to gain confidence that the door will open at predicted operational temperatures. This paper briefly covers the main design features of the radiation cover and measures taken to mitigate risks to cover deployment. As the chosen FD04 model Frangibolt actuator has minimal flight heritage, the main focus of this paper is the testing, results and conclusions with the FD04 while discussing key lessons learned with respect to the use of the FD04 actuator in this application.

Carte, David B.↗

Spacecraft Common Deployable Boom Hinge Deploy and Latching Mechanisms

JPL is developing deployable radio frequency (RF) reflector booms for spaceflight usage on two different earth orbiter projects scheduled to launch in the early 2020’s. The static alignment and thermal stability requirements for these RF reflector booms are challenging. A common mechanism design has been developed for the deployment and latching of boom hinges which avoids significant parasitic loads on the alignment critical structures after completion of mechanism function. The mechanism design includes a high-aspect ratio torsion spring with viscous damper for hinge closure as well as an actuator-driven flexured hook and roller latch for joint preloading. This paper describes noteworthy mechanism design details, test results, challenges, and lessons learned during the development effort.

Renson, Marcel↗

Computer simulation of multigrid body dynamics and control

The objective is to set up and analyze benchmark problems on multibody dynamics and to verify the predictions of two multibody computer simulation codes. TREETOPS and DISCOS have been used to run three example problems - one degree-of-freedom spring mass dashpot system, an inverted pendulum system, and a triple pendulum. To study the dynamics and control interaction, an inverted planar pendulum with an external body force and a torsional control spring was modeled as a hinge connected two-rigid body system. TREETOPS and DISCOS affected the time history simulation of this problem. System state space variables and their time derivatives from two simulation codes were compared.

Swaminadham, M.↗

Nonlinear Equations of Motion for Cantilever Rotor Blades in Hover with Pitch Link Flexibility, Twist, Precone, Droop, Sweep, Torque Offset, and Blade Root Offset

Nonlinear equations of motion for a cantilever rotor blade are derived for the hovering flight condition. The blade is assumed to have twist, precone, droop, sweep, torque offset and blade root offset, and the elastic axis and the axes of center of mass, tension, and aerodynamic center coincident at the quarter chord. The blade is cantilevered in bending, but has a torsional root spring to simulate pitch link flexibility. Aerodynamic forces acting on the blade are derived from strip theory based on quasi-steady two-dimensional airfoil theory. The equations are hybrid, consisting of one integro-differential equation for root torsion and three integro-partial differential equations for flatwise and chordwise bending and elastic torsion. The equations are specialized for a uniform blade and reduced to nonlinear ordinary differential equations by Galerkin's method. They are linearized for small perturbation motions about the equilibrium operating condition. Modal analysis leads to formulation of a standard eigenvalue problem where the elements of the stability matrix depend on the solution of the equilibrium equations. Two different forms of the root torsion equation are derived that yield virtually identical numerical results. This provides a reasonable check for the accuracy of the equations.

Hodges, D. H.↗

Two SMA-Actuated Miniature Mechanisms

The figures depict two miniature mechanisms actuated by strips made of shape-memory alloy (SMA). A typical SMA is a nickel-titanium alloy known by the trade name "Flexinol" or "Nitinol." In preparation for a typical application, a suitably sized and shaped piece of an SMA is deformed by a predetermined amount at the lower of two operating temperatures, then mounted in a mechanism. When stroking of the mechanism in one direction is desired, the piece of SMA is heated above a transition temperature to make it return to the "remembered" undeformed state. When stroking of the mechanism in the opposite direction is desired, the SMA is cooled below the transition temperature to make it return to the deformed state. Also, the SMA alloy chosen for a specific application is one that has a transition temperature somewhat above the ambient temperature, so that stroking in one direction or the opposite direction can be achieved by heating the SMA, or refraining from heating the SMA, respectively, above the transition temperature. In the present mechanisms as in typical other SMA mechanisms, the heating is effected by electric currents applied via electrical contacts at the ends of the SMA strips. The purpose served by the mechanism of Figure 1 is to lock or release a flexible latch attachment. In preparation for use in this mechanism, two initially straight SMA strips are deformed into curved springs that, when mounted in the mechanism at ambient temperature, clamp the knob at the lower end of the flexible latch attachment. When heated above their transition temperature by an electric current, the SMA strips return to their original straight configuration, thereby releasing the knob. This mechanism is redundant in the sense that as long as at least one of the two SMA strips straightens when commanded to do so, the knob is released. The mechanism of Figure 2 is suited to any of a variety of applications in which there are requirements for a small mechanism that affords lowtorque rotary actuation through a finite angular range. As shown here, the mechanism is used to rotate a coverlatch pin to a release position. In this case, a straight and flat SMA strip is torsionally deformed to a twist angle of about 90deg by use of a torsion bias spring. When the SMA strip is heated, it rotates to its original straight and flat condition.

Willey, Cliff E.↗