Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trace element mapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

X-ray fluorescence microscopy methods for biological tissues

Abstract Synchrotron-based X-ray fluorescence microscopy is a flexible tool for identifying the distribution of trace elements in biological specimens across a broad range of sample sizes. The technique is not particularly limited by sample type and can be performed on ancient fossils, fixed or fresh tissue specimens, and in some cases even live tissue and live cells can be studied. The technique can also be expanded to provide chemical specificity to elemental maps, either at individual points of interest in a map or across a large field of view. While virtually any sample type can be characterized with X-ray fluorescence microscopy, common biological sample preparation methods (often borrowed from other fields, such as histology) can lead to unforeseen pitfalls, resulting in altered element distributions and concentrations. A general overview of sample preparation and data-acquisition methods for X-ray fluorescence microscopy is presented, along with outlining the general approach for applying this technique to a new field of investigation for prospective new users. Considerations for improving data acquisition and quality are reviewed as well as the effects of sample preparation, with a particular focus on soft tissues. The effects of common sample pretreatment steps as well as the underlying factors that govern which, and to what extent, specific elements are likely to be altered are reviewed along with common artifacts observed in X-ray fluorescence microscopy data.

Pushie, M. Jake (ORCID:0000000174945427)↗

Changing chemistry of particulate manganese in the near- and far-field hydrothermal plumes from 15°S East Pacific Rise and its influence on metal scavenging

Dissolved Mn(II) in the hydrothermal plume is known to be microbially oxidized to form Mn(III/IV) oxides, and the Mn oxides scavenge other trace elements in seawater. In the GEOTRACES GP16 cruise, dissolved Mn (dMn) and particulate Mn (pMn) were found to be transported over 4000 km westwards from the Southern Eastern Pacific Rise. Previous studies in this plume showed different removal rates of dMn and pMn as well as pMn size distribution between the near-field (<80 km from the ridge axis) and far-field (>80 km) plumes. In order to understand Mn cycling in these plumes, spatial distribution, oxidation states, and mineral structures of Mn in small size fraction (SSF; 0.8–51 μm) and large size fraction (LSF; >51 μm) particles from the near-field and far-field plumes were examined using micro X-ray fluorescence spectrometry (μ-XRF), X-ray absorption near-edge structure spectroscopy (XANES), chemical species mapping, and extended X-ray absorption fine-structure spectroscopy (EXAFS). In the near-field plume, pMn in the SSF is dominated by oxidized Mn with Mn(III) fractions of ~30%. They are a mixture of δ-MnO 2 and triclinic birnessites that is known to be formed as a result of autocatalytic Mn(II) oxidation at the surface of freshly-formed δ-MnO2, suggesting that both microbial and autocatalytic Mn oxidation occur in the near-field plume. The LSF pMn in the near-field plume is also oxidized and often found in large aggregates several hundreds of μm in size. These aggregates settle out in the near-field and during transport, and are not found in the far-field plume. In the far-field plume where Mn oxides are not newly formed, pMn in the SSF is oxidized, but their Mn(III) fractions are smaller than in the near-field pMn. Unlike the SSF, the far-field plume LSF pMn is dominated by reduced Mn, implying very slow aggregation of pMn in the far-field plume. The different characteristics of pMn between the near-field and far-field plumes affect its scavenging of other trace elements. In the near-field plume, Co, Mo, 231 Pa are associated with pMn, but not in the far-field plume. 231 Pa is adsorbed to pFe rather than pMn in the far-field plume, and Pb is adsorbed to pFe in the entire plume. The result shows that freshly-formed Mn oxides in the near-field plume have higher scavenging capacity than the far-field plume pMn. Our findings suggest that the mineralogical age of Mn oxides may be an important parameter that controls the scavenging of many other trace elements and isotopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Blanco DECam Bulge Survey (BDBS). VI. Extinction Maps Toward Southern Galactic Bulge Globular Clusters

Abstract We present wide-field, high resolution maps of the color excess for 14 globular clusters toward the Southern Galactic bulge. The maps were derived using Gaia EDR3 astrometry and stellar photometry from the Blanco DECam Bulge Survey, which is a deep, wide-field ugriz Y photometric survey of the southern Galactic bulge. Comparisons with WISE 12 μ m images of thermal continuum emission demonstrate that the maps presented here trace interstellar extinction by dust down to 5″ scales. We use the reddening-corrected photometry of proper motion-selected cluster stars to build color–magnitude diagrams for the target globular clusters, which show residual broadening in excess of that expected from the photometric errors alone. This residual broadening is likely to be driven by star-to-star elemental abundance variations.

Astronomy & Astrophysics↗

Tools for uranium characterization in carbonate samples: case studies of natural U–Pb geochronology reference materials

Laser ablation U–Pb analyses of carbonate (LAcarb) samples has greatly expanded the potential for U–Pb dating to a variety of carbonate-producing settings. Carbonates that were previously considered impossible to date using isotope dilution methods may preserve radiogenic domains that can be dated using spatially resolved laser ablation geochronology techniques. Work is ongoing to identify reference materials and to consider best practices for LAcarb. In this study we apply standard and emerging characterization tool sets on three natural samples with the dual goal of enhancing the study of carbonates and establishing a new set of well-characterized natural reference materials for LAcarb studies. We start with the existing carbonate reference material WC-1 from the Permian Reef Complex of Texas, building on the published description to offer a deeper look at U and associated trace elements. We consider a tufa sample from the Miocene Barstow Formation of the Mojave Block, California, as a possible secondary calcite reference material due to its well-behaved U–Pb systematics. There are currently no natural dolomite standards. We present an unusual dolomite sample with very well-behaved U–Pb systematics from the Miocene of the Turkana Basin of Kenya as a possible dolomite reference material for LAcarb dating. In addition to using X-ray fluorescence (XRF) mapping and spectroscopy to better understand U in these natural samples, we have analyzed multiple aliquots of each of them for 87 Sr/ 86 Sr by thermal ionization mass spectrometry (TIMS). The Sr isotope compositions are analytically homogeneous within petrographically homogeneous regions of all three samples, and thus these materials could be used as Sr isotope standards as well. While not part of the current contribution, this combination could streamline simultaneous LA analyses of 87 Sr/ 86 Sr and U–Pb geochronology.

36 MATERIALS SCIENCE↗

Knowledge Graph for End-to-End Traceability of an Integrated Human-Earth System Model

Integrated human-Earth system models inform energy-water-land system dynamics and policies, yet their results are difficult to trace through input-data, model structure, scenario configurations, and solved outputs. Because this information is siloed across disconnected artifacts, process-based IAMs have historically lacked a unified, queryable representation. Such lack of traceability prevents researchers from systematically isolating the multi-sector drivers of complex outcomes (such as tracing water-scarcity results back to distant energy-system dynamics) or conducting holistic uncertainty attribution across hundreds of interacting parameters. To address this concern, our work documents the software engineering process of a knowledge graph that unifies these four layers for the Global Change Analysis Model (GCAM-USA_Reference scenario, GCAM v9.1). The graph was built as a relational property graph in DuckDB from the run’s own artifacts: the input-preparation dependency map (gcamdata chunk map), the model’s XML input files, the run configuration, and the results database (BaseX), successfully mapping the model’s declared structure. The resulting graph comprises 204,321 nodes and 1,687,814 edges across 16 node types and 15 edge types, with approximately 16.3 million time-series values stored separately to maintain structural efficiency. To ensure representation fidelity, every edge carries an epistemic-status annotation recording the warrant for the relationship (structural, provenance, dependency, or model-derived), and a machine-readable provenance ledger classifying the origin of every schema element. Evaluation against a fixed five-benchmark suite with locked baselines reports zero structural orphans, zero dangling edge endpoints, and 100% of output-producing technologies traceable to raw input files. Two interactive interfaces present the graph, including a serverless browser application built on DuckDB-Wasm. By establishing the first end-to-end provenance framework for an IAM, this work enables researchers and scientists to systematically audit complex policy scenarios, debug model structures, and trace policy-relevant outputs to their data origins in real time.

Artifical Intelligence↗

Influence of oxygen on performance of multi-principal element alloy as braze filler for Ni-base alloys

In manufacturing of multi-principal element alloys (MPEAs), the casting process is often a primary point of oxygen introduction to the material system, which was demonstrated by the laboratory scale button arc-melting process. Oxygen introduction raises concerns for the mechanical performance of these alloys if employed as structural materials alone or in engineering applications, such as serving as filler materials to enable joining of similar or dissimilar alloy pairs that are conventionally considered difficult to join. In this work, oxide inclusions in an as-cast off-equiatomic MnFeCoNiCu MPEA and Ni-base alloy braze joints made with this MPEA were evaluated by synchrotron x-ray diffraction mapping and electron microscopy. MnO was found to be prevalent throughout the cast MPEA and was chemically reduced during brazing by trace Al from the base material, Ni-base Alloy 600. Incomplete reaction of the MnO with Al, and some alternative reaction with Cr, left a mixture of MnO, Al 2 O 3 , and Cr 2 O 3 in the as-brazed joint, with the oxides concentrated near the braze centerline due to directional solidification. Further, in the braze joints, the non-oxide constituent phases detected were an FCC matrix and particles of Cr 23 C 6 , Cr 7 C 3 , and TiN which are all native to Alloy 600. The evolution of oxides within the brazed joints at elevated service temperatures of 600-800°C was also evaluated. While MnO and Al 2 O 3 were stable during high-temperature service, Cr 2 O 3 particles grew to several hundred microns, with dissolved oxygen in the MPEA providing a significant source for oxide growth. Comparing tensile performance of the as-brazed condition with post-service conditions showed that the evolution of oxide particles contributed to an increase in strength and decrease in ductility of the brazed joints. Evaluating particle morphologies among fracture surfaces of individual specimens demonstrated that large Cr 2 O 3 particles and continuous cluster networks of Al 2 O 3 were the features most detrimental to total elongation. Hence, unmitigated evolution of oxygen-containing species during brazing and service conditions is detrimental to the ductility of the brazed joints, which highlights the importance of oxygen control in initial manufacturing of MPEAs for engineering applications.

36 MATERIALS SCIENCE↗

FLARE: field line analysis and reconstruction for 3D boundary plasma modeling

The FLARE code is a magnetic mesh generator that is integrated within a suite of tools for the analysis of the magnetic geometry in toroidal fusion devices. A magnetic mesh is constructed from field line segments and permits fast reconstruction of field lines in 3D boundary plasma codes such as EMC3-EIRENE. Both intrinsically non-axisymmetric configurations (stellarators) and those with symmetry breaking perturbations of an axisymmetric equilibrium (tokamaks) are supported. The code itself is written in Modern Fortran with MPI support for parallel computing, and it incorporates object-oriented programming for the definition of the magnetic field and the material surface geometry. Extended derived types for a number of different magnetohydrodynamic equilibrium and plasma response models are implemented. The core element of FLARE is a field line tracer with adaptive step-size control, and this is integrated into tools for the construction of Poincaré maps and invariant manifolds of X-points. A collection of high-level procedures that generate output files for visualization is build on top of that. The analysis modules are build with Python frontends that facilitate customization of tasks and/or scripting of parameter scans.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Evolution of Galaxies and Clusters at High Spatial Resolution with Advanced X-ray Imaging Satellite (AXIS)

Stellar and black hole feedback heat and disperse surrounding cold gas clouds, launching gas flows off circumnuclear and galactic disks, producing a dynamic interstellar medium. On large scales bordering the cosmic web, feedback drives enriched gas out of galaxies and groups, seeding the intergalactic medium with heavy elements. In this way, feedback shapes galaxy evolution by shutting down star formation and ultimately curtailing the growth of structure after the peak at redshift 2–3. To understand the complex interplay between gravity and feedback, we must resolve both the key physics within galaxies and map the impact of these processes over large scales, out into the cosmic web. The Advanced X-ray Imaging Satellite (AXIS) is a proposed X-ray probe mission for the 2030s with arcsecond spatial resolution, large effective area, and low background. AXIS will untangle the interactions of winds, radiation, jets, and supernovae with the surrounding interstellar medium across the wide range of mass scales and large volumes driving galaxy evolution and trace the establishment of feedback back to the main event at cosmic noon. This white paper is part of a series commissioned for the AXIS Probe mission concept; additional AXIS white papers can be found at the AXIS website.

47 OTHER INSTRUMENTATION↗

SUDA: A SUrface Dust Analyser for Compositional Mapping of the Galilean Moon Europa

Abstract The Surface Dust Analyser (SUDA) is a mass spectrometer onboard the Europa Clipper mission for investigating the surface composition of the Galilean moon Europa. Atmosphereless planetary moons such as the Galilean satellites are wrapped into a ballistic dust exosphere populated by tiny samples from the moon’s surface produced by impacts of fast micrometeoroids. SUDA will measure the composition of such surface ejecta during close flybys of Europa to obtain key chemical signatures for revealing the satellite’s composition such as organic molecules and salts, history, and geological evolution. Because of their ballistic orbits, detected ejecta can be traced back to the surface with a spatial resolution roughly equal to the instantaneous altitude of the spacecraft. SUDA is a Time-Of-Flight (TOF), reflectron-type impact mass spectrometer, optimized for a high mass resolution which only weakly depends on the impact location. The instrument will measure the mass, speed, charge, elemental, molecular, and isotopic composition of impacting grains. The instrument’s small size of$268 ~\mathrm {mm} \times 250 ~\mathrm {mm} \times 171$ 268 mm × 250 mm × 171 $~\mathrm {mm}$ mm , radiation-hard design, and rather large sensitive area of 220 cm 2 matches well the challenging demands of the Clipper mission.

Astronomy & Astrophysics↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the structural and morphological effects of synthesis route on NpO 2

The availability of actinide standard materials for use in nuclear safeguard applications is critical, as is thorough characterization thereof. Although accurate trace element compositions and isotopic considerations are paramount for deployment of reference standards, structural characterization is also essential towards accurately describing the chemical form and potential matrix effects in candidate materials. Here, to this end, samples of NpO 2 were synthesized via a direct denitration (DD) method and probed with powder X-ray diffraction (PXRD), Raman spectroscopy, and scanning electron microscopy (SEM) for structural and morphological characterization and comparison with NpO 2 materials produced via modified direct denitration (MDD). PXRD confirmed the bulk identity of NpO 2 , and no additional phases were identified using this method. Analysis of Raman data collected using a 532 nm excitation wavelength indicates that samples are mostly phase pure; however, some variability in spectral features is observed. Analysis of additional spectroscopic data collected with a 785 nm excitation wavelength revealed variability in the relative intensity of spectral features. Raman spectroscopy indicates that the sample is primarily NpO 2 ; however, additional signals indicate possible structural disorder, oxidized species, or potential contributions from other Np phases. To further investigate the possibility of additional phase contributions within the sample of NpO 2 , Raman spectroscopic mapping was employed to examine the homogeneity of the sample produced via DD. From this analysis, we determined that despite variability in the intensity of Raman-active vibrational modes, consistent spectra are obtained throughout the area of the sample investigated. SEM images show aggregates with variable sizes and shapes, with rounded, primary particles possessing an average diameter of approximately 100 nm. Comparison of the results of these multimodal analyses to the literature indicates that the crystal chemical, spectroscopic, and microstructural properties of NpO 2 vary based on synthesis method, even if X-ray diffraction data indicate that the bulk phase is NpO 2 .

Direct denitration↗

A three-dimensional laser ray-tracing methodology for radiation-hydrodynamics simulations

We report on a methodology for performing laser ray-tracing in three spatial dimensions for radiation-hydrodynamics simulation codes. Our method, which is an extension of that developed in Haines et al., Comput. Fluids 201, 104478 (2020), utilizes an automatically generated separate mesh for the laser ray-tracing from the radiation-hydrodynamics mesh. This enables the laser mesh to be tailored to minimize ray noise with significantly fewer rays than would be required when the ray-tracing is performed on the radiation-hydrodynamics mesh, primarily by allowing the use of high-aspect-ratio cells that are not suitable for hydrodynamics solvers. For a planar target, we show that our method provides a ≈ 100× reduction in computational expense to achieve a fixed level of ray noise relative to ray-tracing directly on the radiation-hydrodynamics mesh. The relatively low ray requirement also enables efficient computation of cross-beam energy transfer. Each cell in the logically cubic laser mesh is a non-convex dodecahedron with triangular sides, and numerical integration of the ray trajectories and inverse bremsstrahlung is performed by mapping each cell to the unit cube. We will describe our methodology in detail as well as its implementation in the xRAGE radiation-hydrodynamics code, discuss performance, and present the results from applying the methodology to test problems with analytic solutions for laser ray-tracing through a quadratic density gradient with an analytic solution as well as for a laser-driven heat front. In 3D radiation-hydrodynamics simulations of laser-driven experiments performed on the National Ignition Facility, laser ray-tracing with our methodology uses less than 1% of total computational time while introducing acceptably low levels of ray noise.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LABQ3: Bayesian method for quantification of mineral compositions and nano-scale elemental mapping of 3D synchrotron XCT data

Quantitative analysis of mineral compositions is essential in understanding geochemical, mineralogical and environmental processes. Fine-resolution 3D imaging is widely done using synchrotron X-ray computed tomography (XCT), but existing analyses are limited to visualization and segmentation. This paper presents a new method, Linear Attenuation Bayesian Quantitative 3D-mapper (LABQ3), based on the linearity of X-ray attenuation with respect to elemental concentrations. To address the random variability in attenuation measurements, LABQ3 employs Bayesian decision theory to minimize classification error, using reference attenuation distributions from scans of pure mineral standards. To demonstrate LABQ3 and test its performance, we studied precipitated carbonate samples. XCT scans were done at multiple energies using the transmission X-ray microscope (TXM) at beamline 32-ID-C of the Advanced Photon Source at Argonne National Laboratory. The reconstructed 3D images have a voxel size of 20 nm. Analyses revealed rich nano-scale compositional heterogeneity within individual particles. A mixture of calcium and cadmium produced an overall stoichiometric composition of (Ca 0.78 ,Cd 0.22 )CO 3 , with some voxels containing nearly pure CdCO 3 . The addition of zinc led to an overall stoichiometric composition of 33% Ca, 28% Cd, 39% Zn, with a nearly pure CaCO 3 core and compositional zonation through the rim. These compositional gradients are related to temporal sequences of carbonate mineral formation where Cd precipitated at the beginning in (Ca,Cd)CO 3 , while Cd and Zn precipitated at the end in (Ca, Cd,Zn)CO 3 . Results differ from bulk analyses using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), showing that LABQ3 provides particle-specific insights. LABQ3 distinguishes itself by quantifying chemical compositions along a continuum, making it different from XCT analyses based on segmentation. LABQ3 allows simultaneous acquisition of morphology and chemical composition in 3D, facilitating the interpretation of chemical gradients of trace elements, quantification of solid solution compositions, inferences about temporal sequences of mineral precipitation, and addressing other concerns about solid-phase chemistry.

58 GEOSCIENCES↗

Imaging Zn and Ni distributions in leaves of different ages of the hyperaccumulator Noccaea caerulescens by synchrotron-based X-ray fluorescence

Mapping of leaves of hyperaccumulators can provide insights into the mechanisms these species utilize to accumulate high metal concentrations. We used synchrotron-based X-ray fluorescence (SXRF) to perform Zn and Ni imaging in leaves of different ages of Noccaea caerulescens. A mature leaf of the related non-hyperaccumulator Thlaspi arvense was also imaged. The concentrations of Zn, Ni, Co, and Cr in N. caerulescens grown on an ultramafic soil were 9-, 10-, 12-, and 3-fold higher than T. arvense. N. caerulescens showed an exceptional ability to accumulate Zn from the soil, posing a bioconcentration factor of 6.7. T. arvense had Zn and Ni distributed uniformly in the leaf blade with doubling fluorescence counts in the tip and margins, suggesting a strategy to excrete metals and avoid toxicity. On the other hand, N. caerulescens displayed distinctly different Zn and Ni accumulation patterns, regardless of the age or metal concentration in the leaves. Zinc was mainly distributed in the cells surrounding the central and secondary veins. Nickel accumulated in the margins and tips of the leaf blade. Finally, given the time required to image large leaves in synchrotron facilities, small leaves can be used to represent the leaf distribution of Zn and Ni in N. caerulescens.

36 MATERIALS SCIENCE↗