Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Space charge studies in FFAG using the tracking code Zgoubi

A method is implemented in Zgoubi that allows the computation of space charge effects in 2D distributions and with some restrictions in 3D distributions. It relies on decomposing field maps or analytical elements into slices and applying a space charge kick to the particles. The aim of this study is to investigate the accuracy of this technique, its limitations/advantages by comparisons with other linear/nonlinear computation methods and codes, and to apply it to high power fixed field ring design studies.

43 PARTICLE ACCELERATORS↗

Exploring code portability solutions for HEP with a particle tracking test code

Traditionally, high energy physics (HEP) experiments have relied on x86 CPUs for the majority of their significant computing needs. As the field looks ahead to the next generation of experiments such as DUNE and the High-Luminosity LHC, the computing demands are expected to increase dramatically. To cope with this increase, it will be necessary to take advantage of all available computing resources, including GPUs from different vendors. A broad landscape of code portability tools—including compiler pragma-based approaches, abstraction libraries, and other tools—allow the same source code to run efficiently on multiple architectures. In this paper, we use a test code taken from a HEP tracking algorithm to compare the performance and experience of implementing different portability solutions. While in several cases portable implementations perform close to the reference code version, we find that the performance varies significantly depending on the details of the implementation. Achieving optimal performance is not easy, even for relatively simple applications such as the test codes considered in this work. Several factors can affect the performance, such as the choice of the memory layout, the memory pinning strategy, and the compiler used. The compilers and tools are being actively developed, so future developments may be critical for their deployment in HEP experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Developments in the Code RITRACKS (Relativistic Ion Tracks)

The code RITRACKS (Relativistic Ion Tracks) was developed to simulate detailed stochastic radiation track structures of ions of different types and energies. Many new capabilities were added to the code during the recent years. Several options were added to specify the times at which the tracks appear in the irradiated volume, allowing the simulation of dose-rate effects. The code has been used to simulate energy deposition in several targets: spherical, ellipsoidal and cylindrical. More recently, density changes as well as a spherical shell were implemented for spherical targets, in order to simulate energy deposition in walled tissue equivalent proportional counters. RITRACKS is used as a part of the new program BDSTracks (Biological Damage by Stochastic Tracks) to simulate several types of chromosome aberrations in various irradiation conditions. The simulation of damage to various DNA structures (linear and chromatin fiber) by direct and indirect effects has been improved and is ongoing. Many improvements were also made to the graphic user interface (GUI), including the addition of several labels allowing changes of units. A new GUI has been added to display the electron ejection vectors. The parallel calculation capabilities, notably the pre- and post-simulation processing on Windows and Linux machines have been reviewed to make them more portable between different systems. The calculation part is currently maintained in an Atlassian Stash® repository for code tracking and possibly future collaboration.

Plante, Ianik↗

Method and Apparatus for Determining Position Using Global Positioning Satellites

A global positioning satellite receiver having an antenna for receiving a L1 signal from a satellite is presented. The L1 signal is processed by a preamplifier stage including a band pass filter and a low noise amplifier and output as a radio frequency (RF) signal. A mixer receives and de-spreads the RF signal in response to a pseudo-random noise code, i,e., Gold code, generated by an internal pseudo-random noise code generator. A microprocessor enters a code tracking loop, such that during the code tracking loop, it addresses the pseudorandom code generator to cause the pseudo-random code generator to sequentially output pseudo-random codes corresponding to satellite codes used to spread the L1 signal, until correlation occurs. When an output of the mixer is indicative of the occurrence of correlation between the RF signal and the generated pseudo-random codes, the microprocessor caters an operational state which slows the receiver code sequence to stay locked with the satellite cede sequence. The output of the mixer is provided to a detector which, in turn, controls certain routines of the microprocessor. The microprocessor will output pseudo range information according to an interrupt routine in response detection of correlation. The pseudo range information is to be telemetered to a ground station which determines the position of the global positioning satellite receiver.

John L Ward↗

Method and apparatus for determining position using global positioning satellites

A global positioning satellite receiver having an antenna for receiving a L1 signal from a satellite. The L1 signal is processed by a preamplifier stage including a band pass filter and a low noise amplifier and output as a radio frequency (RF) signal. A mixer receives and de-spreads the RF signal in response to a pseudo-random noise code, i.e., Gold code, generated by an internal pseudo-random noise code generator. A microprocessor enters a code tracking loop, such that during the code tracking loop, it addresses the pseudo-random code generator to cause the pseudo-random code generator to sequentially output pseudo-random codes corresponding to satellite codes used to spread the L1 signal, until correlation occurs. When an output of the mixer is indicative of the occurrence of correlation between the RF signal and the generated pseudo-random codes, the microprocessor enters an operational state which slows the receiver code sequence to stay locked with the satellite code sequence. The output of the mixer is provided to a detector which, in turn, controls certain routines of the microprocessor. The microprocessor will output pseudo range information according to an interrupt routine in response detection of correlation. The pseudo range information is to be telemetered to a ground station which determines the position of the global positioning satellite receiver.

Ward, John↗

Bar-Code System Tracks Test Equipment

Administration of complicated system speeded and simplified. Computer system uses bar codes to keep track of more than 2,200 items of test equipment. BETUS (Barcode Equipment Tracking and Utilization System), maintains data base on what items borrowed, who is using them and where, and when calibrated. Keeps records on tools and small electronic components. Saves on equipment purchases and recovers missing equipment more quickly. Cuts check-in and checkout time by 90 percent.

Rogers, Jacob R.↗

Spread spectrum acquisition and tracking performance for Shuttle communication links

The spread spectrum acquisition and tracking performance for the Shuttle S-band and Ku-band communication links are analyzed and compared to test results. The S-band link requirements are more severe than those of the Ku-band links, hence, different despreader designs were developed for the two systems. The S-band despreader acquires pseudonoise code lock by examining all possible code phases in half chip steps while the Ku-band despreader acquires pseudonoise code lock by continuously sweeping a tau-jitter loop. Both despreaders employ a tau-jitter loop for code tracking. The code tracking performance is computed for the tau-jitter loop and compared to that of the more complex delay lock loop.

Alem, W. K.↗

Using machine learning for particle track identification in the CLAS12 detector

Particle track reconstruction is the most computationally intensive process in nuclear physics experiments. Traditional algorithms use a combinatorial approach that exhaustively tests track measurements ("hits") to identify those that form an actual particle trajectory. In this article, we describe the development of four machine learning (ML) models that assist the tracking algorithm by identifying valid track candidates from the measurements in drift chambers. Several types of machine learning models were tested, including: Convolutional Neural Networks (CNN), Multi-Layer Perceptrons (MLP), Extremely Randomized Trees (ERT) and Recurrent Neural Networks (RNN). As a result of this work, an MLP network classifier was implemented as part of the CLAS12 reconstruction software to provide the tracking code with recommended track candidates. The resulting software achieved accuracy of greater than 99% and resulted in an end-to-end speedup of 35% compared to existing algorithms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dual Event Generator IOC (siocDualTiming) v1.0

Dual Timing IOC is an EPICS IOC that uses the "Dual Event Generator Support (dual-evg-support) v1.0" (track code: 2026-009) module to perform control and status of the "Dual Event Generator (dual-evg) v1.0" (track code: 2023-012) project, both of them previously disclosed.

Russo, Lucas [Lawrence Berkeley National Laborator↗

Charged Particle Tracking for the GlueX Detector

The GlueX experiment is a new experiment under construction at the Thomas Jefferson National Accelerator Facility designed to study gluonic degrees of freedom via the production of ``hybrid'' mesons with exotic quantum numbers. At full luminosity, the trigger rate is expected to be on the order of 150 kHz and the data rate to tape is expected to be on the order of 300 MB/s. In order to reduce the reconstruction time, the current GlueX analysis framework is multi-threaded such that multiple events can be analyzed in parallel on multi-core machines. The tracking code presents the largest bottleneck in the event reconstruction. By taking advantage of Single-Instruction, Multiple-Data (SIMD) instructions in the three-vector and matrix operations needed in the tracking code, the reconstruction can be sped up considerably. The current status of the tracking reconstruction for GlueX will be presented.

Taylor, Simon↗

The first clinical implementation of electromagnetic transponder-guided MLC tracking

Purpose: We report on the clinical process, quality assurance, and geometric and dosimetric results of the first clinical implementation of electromagnetic transponder-guided MLC tracking which occurred on 28 November 2013 at the Northern Sydney Cancer Centre. Methods: An electromagnetic transponder-based positioning system (Calypso) was modified to send the target position output to in-house-developed MLC tracking code, which adjusts the leaf positions to optimally align the treatment beam with the real-time target position. Clinical process and quality assurance procedures were developed and performed. The first clinical implementation of electromagnetic transponder-guided MLC tracking was for a prostate cancer patient being treated with dual-arc VMAT (RapidArc). For the first fraction of the first patient treatment of electromagnetic transponder-guided MLC tracking we recorded the in-room time and transponder positions, and performed dose reconstruction to estimate the delivered dose and also the dose received had MLC tracking not been used. Results: The total in-room time was 21 min with 2 min of beam delivery. No additional time was needed for MLC tracking and there were no beam holds. The average prostate position from the initial setup was 1.2 mm, mostly an anterior shift. Dose reconstruction analysis of the delivered dose with MLC tracking showed similar isodose and target dose volume histograms to the planned treatment and a 4.6% increase in the fractional rectal V{sub 60}. Dose reconstruction without motion compensation showed a 30% increase in the fractional rectal V{sub 60} from that planned, even for the small motion. Conclusions: The real-time beam-target correction method, electromagnetic transponder-guided MLC tracking, has been translated to the clinic. This achievement represents a milestone in improving geometric and dosimetric accuracy, and by inference treatment outcomes, in cancer radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiparticle Simulation of Intrabeam Scattering for SuperB

In this communication we present the structure of a multiparticle tracking code to investigate intrabeam scattering effects in low emittance colliders. Simulation results obtained with particular reference to the SuperB parameters are compared with those of conventional IBS theories.and with those of a novel semi-analythical model able to predict IBS effect in terms of emittance growths. Intrabeam scattering (IBS) is associated with multiple small angle scattering events leading to emittance growth. In most electron storage rings, the growth rates arising from IBS are usually much longer than damping times due to synchrotron radiation, and its effect is not observed. However, IBS growth rates increase with bunch charge density, and for machines such as SuperB, that operate with high bunch charges and very low emittances, the IBS growth rates can be large enough to observe significant emittance increase. Several formalisms have been developed for calculating IBS growth rates in storage rings, notably those by Piwinski, Bjorken and Mtingwa, and their high energy approximations. Calculations show that IBS should be manageable in both SuperB rings. However these analytical models, based on Gaussian bunch distributions, cannot investigate some interesting aspects of IBS such as its impact during the damping process and its effect on the beam distribution. We developed a multiparticle tracking code, based on the Zenkevich-Bolshakov algorithm, to investigate these effects. In this communication we present the structure of the code and some simulation results obtained with particular reference to the SuperB parameters. Simulation results are compared with those of conventional IBS theories.

43 PARTICLE ACCELERATORS↗

Study of Single and Coupled-Bunch Instabilities for NSLS-II

We study single and coupled-bunch instabilities for the NSLS-II storage ring with a recently developed parallel tracking code. For accurate modelling of the coupled-bunch instability, we investigate improvements to current point-bunch models to take into account finite bunch-size effects. Accurate modelling of single and coupled-bunch instabilities is of crucial importance for the machine performance of light sources such as NSLS-II, that provide high current beams. The complexity of the model consists in the accurate calculation of the impedance of the various components of the ring that can excite single and multibunch instabilities via short and long range wakefields. Moreover, a full account of the coupling between transverse and longitudinal dynamics must be taken into account to study effects such as chromaticity and Landau cavity effects. A parallel algorithm for the study of single and coupled-bunch instabilities has been implemented in a particle tracking code. The theoretical framework for single bunch instabilities is the same used in the code TRANFT, while for coupled-bunch instabilities a self-consistent algorithm has been implemented to allow the study of finite bunch-size effects and multibunch effects in arbitrary filling modes. In this paper we present numerical studies of the microwave instability for NSLS-II and discuss the self-consistent algorithm for simulation of coupled-bunch instabilities.

43 PARTICLE ACCELERATORS↗

Analysis of coupled-bunch instabilities for the NSLS-II storage ring with a 500MHz 7-cell PETRA-III cavity

The NSLS-II storage ring is designed to operate with superconducting RF-cavities with the aim to store an average current of 500 mA distributed in 1080 bunches, with a gap in the uniform filling for ion clearing. At the early stage of the commissioning (phase 1), characterized by a bare lattice without damping wigglers and without Landau cavities, a normal conducting 7-cell PETRA-III RF-cavity structure has been installed with the goal to store an average current of 25 mA. In this paper we discuss our analysis of coupled-bunch instabilities driven by the Higher Order Modes (HOMs) of the 7-cell PETRA-III RF-cavity. As a cure of the instabilities, we apply a well-known scheme based on a proper detuning of the HOMs frequencies based upon cavity temperature change, and the use of the beneficial effect of the slow head–tail damping at positive chromaticity to increase the transverse coupled-bunch instability thresholds. In addition, we discuss measurements of coupled-bunch instabilities observed during the phase 1 commissioning of the NSLS-II storage ring. In our analysis we rely, in the longitudinal case, on the theory of coupled-bunch instability for uniform fillings, while in the transverse case we complement our studies with numerical simulations with OASIS, a novel parallel particle tracking code for self-consistent simulations of collective effects driven by short and long-range wakefields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗