Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dual Event Generator IOC (siocDualTiming) v1.0

Dual Timing IOC is an EPICS IOC that uses the "Dual Event Generator Support (dual-evg-support) v1.0" (track code: 2026-009) module to perform control and status of the "Dual Event Generator (dual-evg) v1.0" (track code: 2023-012) project, both of them previously disclosed.

Russo, Lucas [Lawrence Berkeley National Laborator↗

Charged Particle Tracking for the GlueX Detector

The GlueX experiment is a new experiment under construction at the Thomas Jefferson National Accelerator Facility designed to study gluonic degrees of freedom via the production of ``hybrid'' mesons with exotic quantum numbers. At full luminosity, the trigger rate is expected to be on the order of 150 kHz and the data rate to tape is expected to be on the order of 300 MB/s. In order to reduce the reconstruction time, the current GlueX analysis framework is multi-threaded such that multiple events can be analyzed in parallel on multi-core machines. The tracking code presents the largest bottleneck in the event reconstruction. By taking advantage of Single-Instruction, Multiple-Data (SIMD) instructions in the three-vector and matrix operations needed in the tracking code, the reconstruction can be sped up considerably. The current status of the tracking reconstruction for GlueX will be presented.

Taylor, Simon↗

The first clinical implementation of electromagnetic transponder-guided MLC tracking

Purpose: We report on the clinical process, quality assurance, and geometric and dosimetric results of the first clinical implementation of electromagnetic transponder-guided MLC tracking which occurred on 28 November 2013 at the Northern Sydney Cancer Centre. Methods: An electromagnetic transponder-based positioning system (Calypso) was modified to send the target position output to in-house-developed MLC tracking code, which adjusts the leaf positions to optimally align the treatment beam with the real-time target position. Clinical process and quality assurance procedures were developed and performed. The first clinical implementation of electromagnetic transponder-guided MLC tracking was for a prostate cancer patient being treated with dual-arc VMAT (RapidArc). For the first fraction of the first patient treatment of electromagnetic transponder-guided MLC tracking we recorded the in-room time and transponder positions, and performed dose reconstruction to estimate the delivered dose and also the dose received had MLC tracking not been used. Results: The total in-room time was 21 min with 2 min of beam delivery. No additional time was needed for MLC tracking and there were no beam holds. The average prostate position from the initial setup was 1.2 mm, mostly an anterior shift. Dose reconstruction analysis of the delivered dose with MLC tracking showed similar isodose and target dose volume histograms to the planned treatment and a 4.6% increase in the fractional rectal V{sub 60}. Dose reconstruction without motion compensation showed a 30% increase in the fractional rectal V{sub 60} from that planned, even for the small motion. Conclusions: The real-time beam-target correction method, electromagnetic transponder-guided MLC tracking, has been translated to the clinic. This achievement represents a milestone in improving geometric and dosimetric accuracy, and by inference treatment outcomes, in cancer radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiparticle Simulation of Intrabeam Scattering for SuperB

In this communication we present the structure of a multiparticle tracking code to investigate intrabeam scattering effects in low emittance colliders. Simulation results obtained with particular reference to the SuperB parameters are compared with those of conventional IBS theories.and with those of a novel semi-analythical model able to predict IBS effect in terms of emittance growths. Intrabeam scattering (IBS) is associated with multiple small angle scattering events leading to emittance growth. In most electron storage rings, the growth rates arising from IBS are usually much longer than damping times due to synchrotron radiation, and its effect is not observed. However, IBS growth rates increase with bunch charge density, and for machines such as SuperB, that operate with high bunch charges and very low emittances, the IBS growth rates can be large enough to observe significant emittance increase. Several formalisms have been developed for calculating IBS growth rates in storage rings, notably those by Piwinski, Bjorken and Mtingwa, and their high energy approximations. Calculations show that IBS should be manageable in both SuperB rings. However these analytical models, based on Gaussian bunch distributions, cannot investigate some interesting aspects of IBS such as its impact during the damping process and its effect on the beam distribution. We developed a multiparticle tracking code, based on the Zenkevich-Bolshakov algorithm, to investigate these effects. In this communication we present the structure of the code and some simulation results obtained with particular reference to the SuperB parameters. Simulation results are compared with those of conventional IBS theories.

43 PARTICLE ACCELERATORS↗

Study of Single and Coupled-Bunch Instabilities for NSLS-II

We study single and coupled-bunch instabilities for the NSLS-II storage ring with a recently developed parallel tracking code. For accurate modelling of the coupled-bunch instability, we investigate improvements to current point-bunch models to take into account finite bunch-size effects. Accurate modelling of single and coupled-bunch instabilities is of crucial importance for the machine performance of light sources such as NSLS-II, that provide high current beams. The complexity of the model consists in the accurate calculation of the impedance of the various components of the ring that can excite single and multibunch instabilities via short and long range wakefields. Moreover, a full account of the coupling between transverse and longitudinal dynamics must be taken into account to study effects such as chromaticity and Landau cavity effects. A parallel algorithm for the study of single and coupled-bunch instabilities has been implemented in a particle tracking code. The theoretical framework for single bunch instabilities is the same used in the code TRANFT, while for coupled-bunch instabilities a self-consistent algorithm has been implemented to allow the study of finite bunch-size effects and multibunch effects in arbitrary filling modes. In this paper we present numerical studies of the microwave instability for NSLS-II and discuss the self-consistent algorithm for simulation of coupled-bunch instabilities.

43 PARTICLE ACCELERATORS↗

Analysis of coupled-bunch instabilities for the NSLS-II storage ring with a 500MHz 7-cell PETRA-III cavity

The NSLS-II storage ring is designed to operate with superconducting RF-cavities with the aim to store an average current of 500 mA distributed in 1080 bunches, with a gap in the uniform filling for ion clearing. At the early stage of the commissioning (phase 1), characterized by a bare lattice without damping wigglers and without Landau cavities, a normal conducting 7-cell PETRA-III RF-cavity structure has been installed with the goal to store an average current of 25 mA. In this paper we discuss our analysis of coupled-bunch instabilities driven by the Higher Order Modes (HOMs) of the 7-cell PETRA-III RF-cavity. As a cure of the instabilities, we apply a well-known scheme based on a proper detuning of the HOMs frequencies based upon cavity temperature change, and the use of the beneficial effect of the slow head–tail damping at positive chromaticity to increase the transverse coupled-bunch instability thresholds. In addition, we discuss measurements of coupled-bunch instabilities observed during the phase 1 commissioning of the NSLS-II storage ring. In our analysis we rely, in the longitudinal case, on the theory of coupled-bunch instability for uniform fillings, while in the transverse case we complement our studies with numerical simulations with OASIS, a novel parallel particle tracking code for self-consistent simulations of collective effects driven by short and long-range wakefields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-DE-210-05: Improved Accuracy of Liver Feature Motion Estimation in B-Mode Ultrasound for Image-Guided Radiation Therapy

Purpose: In similarity-measure based motion estimation incremental tracking (or template update) is challenging due to quantization, bias and accumulation of tracking errors. A method is presented which aims to improve the accuracy of incrementally tracked liver feature motion in long ultrasound sequences. Methods: Liver ultrasound data from five healthy volunteers under free breathing were used (15 to 17 Hz imaging rate, 2.9 to 5.5 minutes in length). A normalised cross-correlation template matching algorithm was implemented to estimate tissue motion. Blood vessel motion was manually annotated for comparison with three tracking code implementations: (i) naive incremental tracking (IT), (ii) IT plus a similarity threshold (ST) template-update method and (iii) ST coupled with a prediction-based state observer, known as the alpha-beta filter (ABST). Results: The ABST method produced substantial improvements in vessel tracking accuracy for two-dimensional vessel motion ranging from 7.9 mm to 40.4 mm (with mean respiratory period: 4.0 ± 1.1 s). The mean and 95% tracking errors were 1.6 mm and 1.4 mm, respectively (compared to 6.2 mm and 9.1 mm, respectively for naive incremental tracking). Conclusions: High confidence in the output motion estimation data is required for ultrasound-based motion estimation for radiation therapy beam tracking and gating. The method presented has potential for monitoring liver vessel translational motion in high frame rate B-mode data with the required accuracy. This work is support by Cancer Research UK Programme Grant C33589/A19727.

60 APPLIED LIFE SCIENCES↗

Predicting tungsten erosion and leakage properties for the new V-shaped small angle slot divertor in DIII-D

Impurity transport modeling of the new tungsten (W)-coated, V-shaped small angle slot (SAS) divertor in the DIII-D tokamak was conducted using the SOLPS-ITER plasma edge code package and the DIVIMP impurity tracking code. The inboard baffle of the current SAS divertor will be shifted closer to the outboard baffle, creating a V-corner at the slot vertex. In addition, the outboard baffle will be coated with 10–15 μm of W for experiments studying high-Z sourcing and leakage in a closed divertor. Modeling of the 'SAS-VW' divertor predicts that these changes to the inner baffle will reduce W gross erosion by 40× relative to the existing SAS divertor when the outer strike point (OSP) is at the V-corner and the ion B × ∇B drift is towards the divertor, driven primarily by significant cooling near the slot vertex. Most W erosion in SAS-VW is expected to occur near the slot entrance, which may pose a higher risk to core contamination than W eroded deeper in the slot. Furthermore, adding a new sheath-based prompt redeposition model increases the sensitivity of redeposition estimates to near-target plasma conditions and may provide more accurate predictions of net erosion. Moving the OSP outboard from the slot vertex ~4 cm onto the W-coated region yields a 40× increase in the gross erosion rate and a 50% decrease in the core leakage fraction. Thus slight variations in strike point location may counteract the potential benefits of the tightly-baffled V slot on minimizing erosion. This impurity transport modeling provides useful guidance for future experiments on the SAS-VW divertor focused on high-Z erosion/redeposition, scrape-off layer transport, and core leakage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GPU Acceleration of Spin Tracking in Colliding Beam Accelerators

The RHIC polarized proton program is at the stage of reaching its design goal of polarization, i.e. 70%. A robust and powerful spin tracking program is very critical for the understanding of spin dynamics and helpful in achieving high polarization. Currently, the RHIC spin tracking code is limited by single particle tracking due to the very high computing power. The goal of this project is to greatly improve the spin tracking computing power to explore more beam/machine parameters.

99 GENERAL AND MISCELLANEOUS↗

Robust impurity detection and tracking for tokamaks

A robust impurity detection and tracking code, able to generate large sets of dust tracks from tokamak camera footage, is presented. This machine learning–based code is tested with cameras from the Joint European Torus, Doublet-III-D, and Magnum-PSI and is able to generate dust tracks with a 65 – 100 % classification accuracy. Moreover, the number dust particles detected from a single camera shot can be up to the order of 1000. Several areas of improvement for the code are highlighted, such as generating more significant training data sets and accounting for selection biases. Finally, although the code is tested with dust in single two-dimensional camera views, it could easily be applied to multiple-camera stereoscopic reconstruction or nondust impurities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-A-BRA-01: Introduction

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-02: Making the Most of a One Hour Lecture with Alternative Teaching Methodologies: Implementing Project-Based and Flipped Learning

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-03: Creative Stimulation: A Flexible Hands-On Approach to Building a Deeper Understanding of Critical Concepts in Radiation Physics

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-04: Incorporating Active Learning Into Medical Physics Education

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-05: Panel Discussion

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-00: Education Council Symposium: Revitalizing Your Medical Physics Classroom: Some Examples and Thoughts from the Trenches

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Edge Zonal Flows and Blob Propagation in Alcator C-Mod

Here we describe recent measurements of the 2-D motion of turbulence in the edge and scrape-off layer (SOL) of the Alcator C-Mod tokamak. This data was taken using the outer midplane gas puff imaging (GPI) camera, which views a 6 cm radial by 6 cm poloidal region near the separatrix just below the outer midplane [1]. The data were taken in Ohmic or RF heated L-mode plasmas at 400,000 frames/sec for {approx}50 msec/shot using a Phantom 710 camera in a 64 x 64 pixel format. The resulting 2-D vs. time movies [2] can resolve the structure and motion of the turbulence on a spatial scale covering 0.3-6 cm. The images were analyzed using either a 2-D cross-correlation code (Sec. 2) or a 2-D blob tracking code (Sec. 3).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗