Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tuned probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A probe for real-time images of particle beams and their analyses in a merged-beams apparatus

A real-time charged particle beam probe was developed, which can be used both as a beam diagnostic (beam tuning) and to quantitatively determine the three-dimensional density distribution of a beam. The probe consists of a microchannel plate, an aluminized phosphor screen deposited on a fiber-optic faceplate, a flexible fiber-optic bundle, and a charge injection device (CID) in tandem. Digital or analog video output of the CID is fed into a computer or oscilloscope, respectively, for analysis or observation. The probe can be moved continuously along the beams' paths to obtain 'pictures' of the beam at any desired interval, thus giving three-dimensional form factors. The beams, singly or simultaneously, may be observed on the monitor facilitating the task of beam adjustment for optimum overlap. The digital output is used for quantitative computation of the beam overlaps. The device is linear with beam intensity, but the performance degrades with time due to beam damage of the microchannel plate.

Forand, J. L.↗

Reverberation Chamber Uniformity Validation and Radiated Susceptibility Test Procedures for the NASA High Intensity Radiated Fields Laboratory

The NASA Langley Research Center's High Intensity Radiated Fields Laboratory has developed a capability based on the RTCA/DO-160F Section 20 guidelines for radiated electromagnetic susceptibility testing in reverberation chambers. Phase 1 of the test procedure utilizes mode-tuned stirrer techniques and E-field probe measurements to validate chamber uniformity, determines chamber loading effects, and defines a radiated susceptibility test process. The test procedure is segmented into numbered operations that are largely software controlled. This document is intended as a laboratory test reference and includes diagrams of test setups, equipment lists, as well as test results and analysis. Phase 2 of development is discussed.

Koppen, Sandra V.↗

Simultaneous measurements of velocity, temperature, and pressure using rapid CW wavelength-modulation laser-induced fluorescence of OH

The beam from a rapid-tuning single-frequency laser was used to probe the R1(7) and R1(11) A2Sigma(+) - X2Pi(0,0) line pair of OH at a 45-deg incident angle in a combustion-driven, supersonic free jet. Absorption line shapes were recorded in spatially resolved, single-point fluorescence. The Doppler shift, intensity ratio, and collisional broadening of the measured line pair were used to determine velocity, temperature, and pressure. The repetition rate of the measurement was 3 kHz.

Chang, A. Y.↗

Phase control of electromagnetically induced transparency and its applications to tunable group velocity and atom localization

We show that, by simple modifications of the usual three-level lambda-type scheme used in electromagnetically induced transparency (EIT) schemes, phase dependence in the response of the atomic medium to a weak probe field can be introduced. This gives rise to phase dependent susceptibility. By properly controlling phase and amplitudes of the drive fields we obtain variety of interesting effects. On one hand we obtain phase control of the group velocity of a probe field passing through medium to the extend that continuous tuning of the group velocity from subluminal to superluminal and back is possible. While on the other hand, by choosing one of the drive fields to be a standing wave field inside a cavity, we obtain sub-wavelength localization of moving atoms passing through the cavity field.

Zubairy, M. Suhail↗

Advanced electromagnetic methods for aerospace vehicles

The Advanced Helicopter Electromagnetics is centered on issues that advance technology related to helicopter electromagnetics. Progress was made on three major topics: composite materials; precipitation static corona discharge; and antenna technology. In composite materials, the research has focused on the measurements of their electrical properties, and the modeling of material discontinuities and their effect on the radiation pattern of antennas mounted on or near material surfaces. The electrical properties were used to model antenna performance when mounted on composite materials. Since helicopter platforms include several antenna systems at VHF and UHF bands, measuring techniques are being explored that can be used to measure the properties at these bands. The effort on corona discharge and precipitation static was directed toward the development of a new two dimensional Voltage Finite Difference Time Domain computer program. Results indicate the feasibility of using potentials for simulating electromagnetic problems in the cases where potentials become primary sources. In antenna technology the focus was on Polarization Diverse Conformal Microstrip Antennas, Cavity Backed Slot Antennas, and Varactor Tuned Circular Patch Antennas. Numerical codes were developed for the analysis of two probe fed rectangular and circular microstrip patch antennas fed by resistive and reactive power divider networks.

Balanis, Constantine A.↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3x10(exp 17) and 9x10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17)/cu cm. The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Measuring ionospheric electron density using the plasma frequency probe

During the past decade, the plasma frequency probe (PFP) has evolved into an accurate, proven method of measuring electron density in the ionosphere above about 90 km. The instrument uses an electrically short antenna mounted on a sounding rocket that is immersed in the plasma and notes the frequency where the antenna impedance is large and nonreactive. This frequency is closely related to the plasma frequency, which is a direct function of free electron concentration. The probe uses phase-locked loop technology to follow a changing electron density. Several sections of the plasma frequency probe circuitry are unique, especially the voltage-controlled oscillator that uses both an electronically tuned capacitor and inductor to give the wide tuning range needed for electron density measurements. The results from two recent sounding rocket flights (Thunderstorm II and CRIT II) under vastly different plasma conditions demonstrate the capabilities of the PFP and show the importance of in situ electron density measurements of understanding plasma processes.

Jensen, Mark D.↗

Tuning Concept for Resonant Cavities

Deviations from resonance detected by sampling phases. Automatic tuner feedback control system derives error signal from E and H plane probe signals. Control objective to maintain phase difference between E and H at 90 degrees. Technique estimated to sensitive to fractional frequency deviation of about 5 X 10-16 and applicable not only to masers but also other microwave elements, including klystrons, general purpose oscillators, and frequency standards.

Sydnor, R. L.↗

Simultaneous measurements of velocity and pressure fields in subsonic and supersonic flows through image-intensified detection of laser-induced fluorescence

An optical technique is presented for combined, spatially resolved measurements of two-dimensional velocity and pressure fields in compressible flows. The single-mode frequency of an argon laser is fixed in the wing of an absorption line of iodine molecules, seeded in an underexpanded round jet of nitrogen gas. The emitted fluorescence, being proportional to the amount of absorbed radiation and hence the absorption line-shape function, is detected with an intensified 100 x 100 photodiode array camera. A single-microchannel-plate image intensifier is fiber-optically coupled to the array in order to improve time resolution and SNR. Three components of the velocity vector in a cross-sectional plane are sequentially probed with four laser sheets from three different directions. By shifting the laser frequency in one of the sheets with a piezo-tuned intra-cavity etalon, the slope of the absorption line can be measured in situ in order to provide the required scaling factor for the velocity measurement. With its short measurement times of less than 250 ms, this method is well suited for blow-down wind tunnel experiments.

Hiller, B.↗

Remote sensing of the thermosphere, plasmasphere, and exosphere

An instrument package for remotely measuring thermospheric, exospheric, and plasmaspheric structure and composition is described. This instrument will be flown aboard the second test flight of the Black Brant XII rocket, with an expected apogee of about 1300 km. The experiment package consists of a spectrophotometer to measure He I 584 A, O II 834 A, O I 989 A, hydrogen Lyman beta (1025 A), hydrogen Lyman alpha (1216 A), and O I 1304 A transitions, and a photometer to measure the He II 304 A emission. The He II 304 A photometer consists of a layered synthetic microstructure mirror tuned at 304 A to focus incidence radiation onto a detector. The high altitude to be attained by the rocket is ideally suited to probe the coupling of the various atmospheric regions through the simultaneous measurement of the altitude distributions of several major thermospheric, ionospheric, and exospheric constituents.

Chakrabarti, S.↗

The Radio Plasma Imager Investigation on the IMAGE Spacecraft

Radio plasma imaging uses total reflection of electromagnetic waves from plasmas whose plasma frequencies equal the radio sounding frequency and whose electron density gradients are parallel to the wave normals. The Radio Plasma Imager (RPI) has two orthogonal 500-m long dipole antennas in the spin plane for near omni-directional transmission. The third antenna is a 20-m dipole. Echoes from the magnetopause, plasmasphere and cusp will be received with three orthogonal antennas, allowing the determination of their angle-of-arrival. Thus it will be possible to create image fragments of the reflecting density structures. The instrument can execute a large variety of programmable measuring programs operating at frequencies between 3 kHz and 3 MHz. Tuning of the transmit antennas provides optimum power transfer from the 10 W transmitter to the antennas. The instrument can operate in three active sounding modes: (1) remote sounding to probe magnetospheric boundaries, (2) local (relaxation) sounding to probe the local plasma, and (3) whistler stimulation sounding. In addition, there is a passive mode to record natural emissions, and to determine the local electron density and temperature by using a thermal noise spectroscopy technique.

Reinisch, Bodo W.↗

Design Overview of the DM Radio Pathfinder Experiment

We introduce the DM Radio, a dual search for axion and hidden photon dark matter using a tunable superconducting lumped-element resonator. We discuss the prototype DM Radio Pathfinder experiment, which will probe hidden photons in the 500 peV (100 kHz)-50 neV (10 MHz) mass range. We detail the design of the various components: the LC resonant detector, the resonant frequency tuning procedure, the differential SQUID readout circuit, the shielding, and the cryogenic mounting structure. We present the current status of the pathfinder experiment and illustrate it's potential science reach in the context of the larger experimental program.

axion↗

Dielectric measurement using an open ended coaxial line with an extended center conductor

Permittivity may be determined by measuring the complex reflection coefficient of an open-ended coaxial line placed in contact with a test sample. This method works best for liquid samples. For the measurement of non-liquid materials problems can arise. A perfect preparation is needed to provide a good contact between the tip and the dielectric medium. At times, the dimension of the sensor cannot be freely chosen, as is the case for the measurement of the dielectric constant of the xylem layer of a living tree. The influence of the installation of the sensor on a tree's water status must be minimized by using a small sensor. In such cases the capacitance cannot be optimized. By extending the center conductor of the open-ended coaxial line, some of these problems can be avoided. This provides an additional tool to tune the capacitance of the sensor by adjusting the length of the extension. Therefore the measurement accuracy can be optimized. The sensor also becomes sensitive to a larger volume. A comparative study of a flush and extended tipped probes shows that the ability to measure the dielectric constant of trees has been notably increased due to the extension of the center conductor.

Wegmueller, Urs↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid- state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W. Yu↗