Search NASA⌕ Search

SEARCH · Search NASA

Results for “Two Body Point Absorber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance Analysis and Tank Test Validation of a Hybrid Wave-Current Energy Converter with a Single Power Takeoff

Marine and hydrokinetic (MHK) energy, including ocean waves, tidal current, ocean current and river current, has been recognized as a promising power source due to its full-day availability and high energy potential. At this stage, ocean current energy, tidal energy and ocean wave energy are currently the most competitive sourves among all the categories of MHK. The state of art MHK energy harvesting technology mainly focus on harvesting either ocean wave energy or current energy, but not both. However, a significant amount of ocean waves and tidal/ ocean current coexist in many sites and traditional devices that harvest from a single form of MHK energy, cannot make full use of the coexisting ocean energy. Furthermore, MHK energy harvesting devices need to advance to be cost-effective and competitive with other energy sources. This is difficult to achieve. Ocean wave excitation is irregular, which means that ocean wave height and wave periods are unpredictable and excitation forces on energy harvesting devices can have large variance in amplitude and frequency. Such problems/ restrictions can be possibly addressed by the concept of a hybrid energy converter. In this sense, a hybrid wave-current ocean energy conveter (HWCEC) that simutaneously harvests energy from current and wave with one single power takeoff (PTO) is designed.The wave energy is extracted through relative heaving motion between a floating buoy and a submerged second body, while the current energy is extracted using a marine current turbine (MCT). Energy from both sources are integrated by a hybrid PTO whose concept is based on a mechanical motion rectifier (MMR). In this study, different working modes are investigated together with switching criteria.Simulations were conducted with hydrodynamic coefficients obtained from computational fluid dynamics analysis and boundary element method. Tank tests were conducted for a HWCEC under coexisting wave and current inputs. For comparison, separate baseline tests of a turbine and a two-body point absorber, each acting in isolation, are conducted. Experimental results validate the dynamic modeling and show that a HWCEC can increase the output power with a range between 29-87 percent over either current turbine and wave energy converter acting individually, and it can reduce by up to 70 percent the peak-to-average power ratio compared with the wave energy converter on the tested conditions.Such results demonstrate the potential of the HWCEC as an efficient and cost-effective design.

16 TIDAL AND WAVE POWER↗

Comparative study and test on a two-body wave energy point absorber under various constraints.

Power generation and motion response of the floating wave energy converters is of great importance in the research topic of ocean energy harvesting. As a classic design for harvesting the ocean wave energy, the wave energy point absorber is commonly studied theoretically using the idealized 1DOF and 2DOF dynamic model based on the number of the free body within the system. Whereas the mooring system is usually ignored and only the heave motion is considered. In this paper, a point absorber is designed prototyped and tested in a water tank under three different constrains, the single body 1DOF, the two body 2DOF and the two body 6DOF. All the designs and configurations are presented in detail. Numerical analysis is conducted and presented as well to help understand the test results deeper. The test results indicate that the two body system can be tuned to match with the wave excitation and achieve higher energy absorption. In addition, the compared results between the 2DOF configuration and 6DOF configuration show that the classic 2DOF dynamic model is able to predict the performance of the point absorber with mooring well.

Li, Xiaofan↗

Numerical analysis and wave tank validation on the optimal design of a two-body wave energy converter

To improve the performance of a ‘point absorber’ type wave energy converter (WEC), an additional submerged body can be deployed. The submerged body can be used to increase the equivalent excitation force on the WEC, as well as provide resonance tuning. This paper presents numerical analysis and experimental validation of a two-body point absorber type WEC using a mechanical motion rectifier (MMR) based power takeoff. The two-body point absorber consists of a floating buoy connected to a neutrally buoyant submerged body via the power-takeoff. The mechanical motion rectifier and a ball screw translate the relative heave motion of the two bodies into unidirectional rotation, which in turn spins a generator. Frequency domain analysis suggests there is an optimal submerged body mass for maximum WEC power absorption. Regular wave simulations in the time domain are compared to the results obtained in the frequency domain. While the time domain and frequency domain results predict the same optimal mass ratio, time domain analysis provides a more complex and accurate power result. To validate the time domain model, experimental wave tank testing is conducted using a 1:30 scale model WEC. The experiment shows the two-body WEC can produce twice the amount of power as the single-body WEC with same floating buoy and can be further increased by PTO design and power electronics optimization. Furthermore, wave tank testing shows the two-body WEC has a capture width ratio up to 58% at 59 kW/m and 51% at 36 kW/m.

16 TIDAL AND WAVE POWER↗

On the short-term uncertainty in performance f a point absorber wave energy converter

Of interest, in this study, is the quantification of uncertainty in the performance of a two-body wave point absorber (Reference Model 3 or RM3), which serves as a wave energy converter (WEC). We demonstrate how simulation tools may be used to establish short-term relationships between any performance parameter of the WEC device and wave height in individual sea states. We demonstrate this methodology for two sea states. Efficient structural reliability methods, validated using more expensive Monte Carlo sampling, allow the estimation of uncertainty in performance of the device. Such methods, when combined with metocean data quantifying the likelihood of different sea states, can be useful in long-term studies and in reliability-based design.

16 TIDAL AND WAVE POWER↗

Umbilical Fatigue Analysis for a Wave Energy Converter

Unique umbilical designs for wave energy converters (WECs), including the ability to handle significantly larger motions and loads over long deployments, are often required when conventional marine umbilical designs for offshore oil and gas and offshore wind may not meet the design and cost needs of wave energy technologies. This study details a fatigue analysis of a dynamic power umbilical attached to a two-body floating point absorber WEC system, using the sea states provided for the PacWave testing facilities. The 6 degrees of freedom motion time history for the WEC was simulated, and the motions of the attachment point for the umbilical on the WEC and respective sea states were used to analyze the dynamic motions and fatigue of the connected power umbilical to predict the fatigue life. The results show that the fatigue damage observed is more significant in shallow water, and extensive fatigue damage may occur because of the larger curvature response of the umbilical. The umbilical configurations departing at 90 deg off incoming waves were found to have the highest fatigue life attributed to less extension or compression of the umbilical. However, additional bend stiffener/limiter features may need to be incorporated into the buoyancy section and touchdown regions to minimize curvature-induced fatigue.

50 EE - Wind and Water Power Program - Water (EE-4↗

Wave Energy Prize - 1/50th Testing - Oscilla Power Triton Point Absorber

This submission of data includes all the 1/50th scale testing data completed on the Wave Energy Prize for the Oscilla Power team, and includes: - 1/50th test data (raw & processed) - 1/50th test data video and pictures - 1/50th Test plans and testing documents - SSTF_Submission (summarized results)

1/50th scale↗

National Marine Renewable Energy Center Upgrades - LUPA

The data provided is part of a power take off damping optimization study. The power take off damping coefficient was swept from 0 to approximately 7000 N/m/s during a single regular wave test with a real time control of the motor/generator. The generated power from the LUPA (Lab Upgrade Point Absorber) wave energy converter is reported by the motor drive in watts. The csv files in this submission are the corresponding raw time series outputs for each mode of operation of LUPA (one body heave only, two body heave only, and two body six degrees of freedom). Data comes from testing in the Large WaveFlume (LWF) at the O.H. Hinsdale Wave Research Laboratory in Corvallis, OR.

16 TIDAL AND WAVE POWER↗

RM3 Wave Tank Validation Model

An approximately 1/75th scale point absorber wave energy absorber was built to validate the testing systems of a 16k gallon single paddle wave tank. The model was build based on the RM3 design and incorporated a linear position sensor, a force transducer, and wetness detection sensors. The data set also includes motion tracking data of the device's two bodies acquired from 4x Qualisys cameras. The tank wave spectrum is measured by 4 ultrasonic water height sensors.

16 TIDAL AND WAVE POWER↗

Hypersonic Flow Control Using Upstream Focused Energy Deposition

A numerical study of centerline and off-centerline power deposition at a point upstream of a two-dimensional blunt body at Mach 6.5 at 30 km altitude are presented. The full Navier-Stokes equations are used. Wave drag, lift, and pitching moment are presented as a function of amount of power absorbed in the flow and absorption point location. It is shown that wave drag is considerably reduced. Modifications to the pressure distribution in the flow field due to the injected energy create lift and a pitching moment when the injection is off-centerline. This flow control concept may lead to effective ways to improve the performance and to stabilize and control hypersonic vehicles.

Riggins David W.↗

Optimum power analysis of a self-reactive wave energy point absorber with mechanically-driven power take-offs

This paper studies a self-reactive ocean wave energy converter (WEC) where energy is absorbed through the relative motion between a floating buoy on the ocean surface and a submerged body. Two types of direct-drive power take off (PTO) systems are examined. One adopts a ball screw system in inverse driving mode with mechanical motion rectifier (MMR) that converts the oscillating bi-directional input heave motion into unidirectional rotation to drive an electromagnetic generator, and another one uses a ball screw system to directly drive the generator (called non-MMR). Dynamic models for both types of PTOs are established and integrated with the overall WEC system model in both the time and frequency domains. Numerical simulation is used to investigate the dynamic performance of both PTOs. The influences of the PTO inerter, which is from the rotational inertia of the flywheel and generator, and the WEC drag damping coefficient are discussed and explored. The analytical closed-form solution for the optimum condition of the non-MMR system is derived based on the criterion of maximum power absorption, and numerical simulation yields the optimum condition for the MMR system. Overall, the results under regular and irregular waves show that the PTO inerter in the MMR system can improve the power absorption for small wave periods and maintain the same performance for large wave periods. The PTO inerter in the non-MMR system shifts the peak frequency. The WEC drag damping negatively influences the power absorption in both PTO systems, especially at large wave periods.

16 TIDAL AND WAVE POWER↗

Wave Energy Prize - 1/20th Testing - Oscilla Power Triton Point Absorber

Data from the 1/20th scale testing data completed on the Wave Energy Prize for the Oscilla Power team, including the 1/20th Test Plan, raw test data, video, photos, and data analysis results. The top level objective of the 1/20th scale device testing is to obtain the necessary measurements required for determining Average Climate Capture Width per Characteristic Capital Expenditure (ACE) and the Hydrodynamic Performance Quality (HPQ), key metrics for determining the WEPrize winners.

1/20th scale↗

Performance of High-Resolution Mo/Cu Transition Edge Sensors Fabricated Using a Lift-Off Process

The soft X-ray band below ≈0.5 keV is expected to provide rich information on metallicity, temperature, and distribution of hot gas in our galaxy and the intergalactic medium. Resolving these densely spaced emission lines requires energy resolution on the order of 1--2 eV. The low count rates from diffuse astrophysical sources also necessitate large collection areas, particularly for a sounding rocket instrument with short exposure times and limited resources. This translates to large pixel sizes (about 1 mm 2 ) for a reasonable number of read-out channels. To achieve the required energy resolution with 200 nm thin Au absorbers (heat capacity C about 1 pJ/K), we are developing TES microcalorimeters with very high temperature sensitivity (αI), low enough current sensitivity (βI), and minimal excess noise (M). Out of the various fabrication approaches for the TES bilayer we have explored, the lift-off approach (as pioneered for Mo/Au TES by Joel Weber at NIST) so far is the simplest to execute. The simple square TES geometries we have tested to date show promising results for αI and βI. Measured complex impedance and noise for bare devices without absorbers are well described by two-body thermal models and their excess noise is found to be consistent with predictions for mixed-down Johnson noise by Wessels et al. More sensitive measurements with larger heat capacity are planned to accurately determine excess noise. In this paper, we give an overview of the process and summarize results of our detailed characterization measurements for thermal conductance G, αI, βI, and noise for several devices across a range of bias points.

Felix T Jaeckel↗

Minimizers with discontinuous velocities for the electromagnetic variational method

The electromagnetic two-body problem has neutral differential delay equations of motion that, for generic boundary data, can have solutions with discontinuous derivatives. If one wants to use these neutral differential delay equations with arbitrary boundary data, solutions with discontinuous derivatives must be expected and allowed. Surprisingly, Wheeler-Feynman electrodynamics has a boundary value variational method for which minimizer trajectories with discontinuous derivatives are also expected, as we show here. The variational method defines continuous trajectories with piecewise defined velocities and accelerations, and electromagnetic fields defined by the Euler-Lagrange equations on trajectory points. Here we use the piecewise defined minimizers with the Lienard-Wierchert formulas to define generalized electromagnetic fields almost everywhere (but on sets of points of zero measure where the advanced/retarded velocities and/or accelerations are discontinuous). Along with this generalization we formulate the generalized absorber hypothesis that the far fields vanish asymptotically almost everywhere and show that localized orbits with far fields vanishing almost everywhere must have discontinuous velocities on sewing chains of breaking points. We give the general solution for localized orbits with vanishing far fields by solving a (linear) neutral differential delay equation for these far fields. We discuss the physics of orbits with discontinuous derivatives stressing the differences to the variational methods of classical mechanics and the existence of a spinorial four-current associated with the generalized variational electrodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters

Purpose: Sophisticated small animal irradiators, incorporating cone-beam-CT image-guidance, have recently been developed which enable exploration of the efficacy of advanced radiation treatments in the preclinical setting. Microstereotactic-body-radiation-therapy (microSBRT) is one technique of interest, utilizing field sizes in the range of 1–15 mm. Verification of the accuracy of microSBRT treatment delivery is challenging due to the lack of available methods to comprehensively measure dose distributions in representative phantoms with sufficiently high spatial resolution and in 3 dimensions (3D). This work introduces a potential solution in the form of anatomically accurate rodent-morphic 3D dosimeters compatible with ultrahigh resolution (0.3 mm{sup 3}) optical computed tomography (optical-CT) dose read-out. Methods: Rodent-morphic dosimeters were produced by 3D-printing molds of rodent anatomy directly from contours defined on x-ray CT data sets of rats and mice, and using these molds to create tissue-equivalent radiochromic 3D dosimeters from Presage. Anatomically accurate spines were incorporated into some dosimeters, by first 3D printing the spine mold, then forming a high-Z bone equivalent spine insert. This spine insert was then set inside the tissue equivalent body mold. The high-Z spinal insert enabled representative cone-beam CT IGRT targeting. On irradiation, a linear radiochromic change in optical-density occurs in the dosimeter, which is proportional to absorbed dose, and was read out using optical-CT in high-resolution (0.5 mm isotropic voxels). Optical-CT data were converted to absolute dose in two ways: (i) using a calibration curve derived from other Presage dosimeters from the same batch, and (ii) by independent measurement of calibrated dose at a point using a novel detector comprised of a yttrium oxide based nanocrystalline scintillator, with a submillimeter active length. A microSBRT spinal treatment was delivered consisting of a 180° continuous arc at 225 kVp with a 20 × 10 mm field size. Dose response was evaluated using both the Presage/optical-CT 3D dosimetry system described above, and independent verification in select planes using EBT2 radiochromic film placed inside rodent-morphic dosimeters that had been sectioned in half. Results: Rodent-morphic 3D dosimeters were successfully produced from Presage radiochromic material by utilizing 3D printed molds of rat CT contours. The dosimeters were found to be compatible with optical-CT dose readout in high-resolution 3D (0.5 mm isotropic voxels) with minimal artifacts or noise. Cone-beam CT image guidance was possible with these dosimeters due to sufficient contrast between high-Z spinal inserts and tissue equivalent Presage material (CNR ∼10 on CBCT images). Dose at isocenter measured with optical-CT was found to agree with nanoscintillator measurement to within 2.8%. Maximum dose in line profiles taken through Presage and film dose slices agreed within 3%, with FWHM measurements through each profile found to agree within 2%. Conclusions: This work demonstrates the feasibility of using 3D printing technology to make anatomically accurate Presage rodent-morphic dosimeters incorporating spinal-mimicking inserts. High quality optical-CT 3D dosimetry is feasible on these dosimeters, despite the irregular surfaces and implanted inserts. The ability to measure dose distributions in anatomically accurate phantoms represents a powerful useful additional verification tool for preclinical microSBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

UMass 2-Body WEC Techno-Economic Assessment

The University of Massachusetts (UMass) is developing a 2-body wave energy converter (WEC) device that is converting mechanical power into electricity using a mechanical motion rectifier that allows the system to couple to a flywheel. UMass has completed numerical modeling, wave tank testing, and PTO sub-system testing and needed assistance in developing a techno-economic model to enable optimization of their topology, comparison to a generic heaving point absorber topology, and guide the next steps in their development efforts. The core objective was to develop a techno-economic approach and modeling tool that allows benchmarking of the two topologies across a wide range of scales to evaluate their respective competitiveness in different application spaces. This data includes the final report as well as a supporting spreadsheet containing the data produced for this report.

16 TIDAL AND WAVE POWER↗

A general model for stray dose calculation of static and intensity-modulated photon radiation

Purpose: There is an increasing number of cancer survivors who are at risk of developing late effects caused by ionizing radiation such as induction of second tumors. Hence, the determination of out-of-field dose for a particular treatment plan in the patient’s anatomy is of great importance. The purpose of this study was to analytically model the stray dose according to its three major components. Methods: For patient scatter, a mechanistic model was developed. For collimator scatter and head leakage, an empirical approach was used. The models utilize a nominal beam energy of 6 MeV to describe two linear accelerator types of a single vendor. The parameters of the models were adjusted using ionization chamber measurements registering total absorbed dose in simple geometries. Whole-body dose measurements using thermoluminescent dosimeters in an anthropomorphic phantom for static and intensity-modulated treatment plans were compared to the 3D out-of-field dose distributions calculated by a combined model. Results: The absolute mean difference between the whole-body predicted and the measured out-of-field dose of four different plans was 11% with a maximum difference below 44%. Computation time of 36 000 dose points for one field was around 30 s. By combining the model-calculated stray dose with the treatment planning system dose, the whole-body dose distribution can be viewed in the treatment planning system. Conclusions: The results suggest that the model is accurate, fast and can be used for a wide range of treatment modalities to calculate the whole-body dose distribution for clinical analysis. For similar energy spectra, the mechanistic patient scatter model can be used independently of treatment machine or beam orientation.

60 APPLIED LIFE SCIENCES↗