Search NASA⌕ Search

SEARCH · Search NASA

Results for “Type 304L Stainless Steel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

20 records · Page 2

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

Dissolution Flowsheet for Non-Aluminum Spent Nuclear Fuel Campaign 1

As part of the Accelerated Basin De-inventory (ABD) program, H Canyon plans to dissolve non-aluminum spent nuclear fuel (NASNF) in the 6.3D electrolytic dissolver. NASNF Campaign 1 plans to electrolytically dissolve 68 bundles of fuel assemblies from the Carolinas-Virginia Tube Reactor (CVTR), Heavy Water Components Test Reactor (HWCTR), and Experimental Boiling Water Reactor (EBWR). The fuel assemblies are intact Zircaloy or stainless steel (SS) clad UO 2 rods, tubes, and plates. The H Canyon electrolytic dissolver previously dissolved a variety of UO 2 core fuel types in SS, Zircaloy, Nichrome, or Incoloy cladding from 1969 to 1980. The objective of this study was to identify flowsheet conditions through literature review and laboratory experimentation to safely dissolve NASNF Campaign 1 bundles in the H Canyon electrolytic dissolver. Bench-scale electrolytic dissolution tests were performed to demonstrate a flowsheet for NASNF Campaign 1 bundles. The outer bundles are composed of SS or Al alloy, Al 6061-T6, and contain intact Zircaloy or SS clad UO 2 fuel assemblies. The key objectives of these tests were to determine bounding dissolver chemistries and the sparge requirement to ensure H 2 concentration remain less than 60 vol % of the lower flammability limit (LFL) during dissolution. The impact of HNO 3 concentration and the addition of fluoride on the dissolution efficiency of Zircaloy, 304L SS, Al 6061-T6, and Inconel 625 were examined. While SS, Al, and Inconel 625 readily dissolve utilizing electrolytic dissolution, Zircaloy disintegrated anodically; the surface of Zircaloy oxidized and the oxide layer spalled off and settled at the bottom of the dissolver as an insoluble material. The black flakes were identified as ZrO 2 and 85% of the Zr processed was converted to black ZrO 2 flakes when Zr was anodically disintegrated in 9.5 M HNO 3 .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗