Search NASASearch

SEARCH · Search NASA

Results for “ULTRAVIOLET RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

On-target uniformity of the OMEGA 60-beam inertial confinement fusion laser

Successful direct-drive inertial confinement fusion (ICF) experiments require excellent on-target laser 9 irradiance uniformity maintained over the duration of the pulse. Achieving this symmetry relies on maintaining an 10 energy, power, and fluence balance among all beams in a multibeam laser system. As a result of the improvements 11 described in this paper, the OMEGA 60-beam laser performance has been assessed at approximately 2% on-target 12 irradiance nonuniformity using an updated performance assessment metric that accounts for the laser diagnostic noise 13 floor. The performance is measurement-limited, prompting the need for an improved diagnostic suite. This manuscript 14 provides a comprehensive first-order assessment of extant status of on-target energy, power, and fluence uniformity 15 and explores avenues for improvements.

Diagnostics

Molecular theory capability: LANL-PEM-Atomic implements universal descriptions of molecular photoionization

Photoionization of atomic ions, the process through which atoms in bound states absorb radiation by losing electrons, is a vital part of describing radiative transfer in mission-relevant dynamics. The photoionization of molecules dominates radiative transfer of ultraviolet (UV) and extreme UV (EUV) radiation in colder atmospheres (temperature < 30,000 degrees Kelvin). Consequently, air, which is quite transparent to our eyes (i.e., in the visible frequency regime) is remarkably opaque to radiation in much of the UV and EUV frequency regimes. This opacity makes air and other gas systems quite efficient at absorbing UV and EUV radiation, which heats the gas until ionization makes it transparent. This effect is important in describing a host of relevant phenomena, ranging from charge separation in high-altitude nuclear events and the dynamics of a nuclear fireball to the electrostatic discharges (sparks) that complicate weapons disassembly at Pantex.

74 ATOMIC AND MOLECULAR PHYSICS

Estimating UV-B, UV-Erithemic, and UV-A Irradiances From Global Horizontal Irradiance and MERRA-2 Ozone Column Information

The ground ultraviolet (UV) solar radiation is relevant due to its impacts on plastics degradation (mainly UVA) and on human health (UVB and erithemic UV (UVE)). UV ground measurements are not as ubiquitous as the relatively common global horizontal irradiance (GHI) measurements. Three simple models that estimate the UVA, UVB, and UVE components of solar irradiance from GHI and ozone column information are locally adjusted and validated. Five one-minute datasets from three sites in southeastern South America and two in the United States are used for simultaneous solar irradiance and UV data. All sites correspond to temperate mid-latitude regions. Simultaneous atmospheric total ozone column information is obtained from the reanalysis modern-era retrospective analysis for research and applications (MERRA-2) database for each site. Aside from locally adjusted models, average models with a single set of coefficients are also evaluated. For instance, the best average model is able to estimate UVE with a typical uncertainty below 12% and mean biases between +-3%, relative to the average of the measurements. Similar results are reported for the UVB and UVA components. These results, which can be useful in regions with similar climate and geography, provide a simple way to estimate UV irradiance under all-sky conditions with known uncertainty. This is an alternative to global satellite-based UV estimates, which can have high uncertainties at specific locations. Because MERRA-2 information has a global coverage, when coupled with good satellite-based estimates for GHI, UV irradiances can be estimated by this method over a large territory.

environmental UV radiation

Probing coherent electronic superpositions of singly and doubly excited states of krypton with extreme-ultraviolet four-wave-mixing spectroscopy

Radiative nonlinear four-wave mixing can monitor the evolution of electronic wave packets, providing access to lifetimes and quantifying the light-induced couplings between excited states. In this article, we report the observation of quantum beats in an autoionizing electronic wave packet in krypton, probed using this technique. Analysis of the signal reveals that these beats originate from the contribution of previously unassigned, doubly excited states interacting with singly excited ones. We introduce a minimal theoretical model, based on multichannel quantum-defect theory, which quantitatively reproduces both the wave-packet dynamics and the static spectrum. This work combines a versatile, noncommensurate XUV-IR-based experimental scheme with a tractable model, establishing a powerful approach for the metrology and control of complex, correlated electronic states.

74 ATOMIC AND MOLECULAR PHYSICS

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

The effect of ICRH and NBI on tungsten transport in neon edge radiation cooled discharges in TEXTOR

Tungsten is planned to be the plasma-facing material for the main chamber and divertor in future devices like ITER, SPARC, and DTT. To address risks associated with tungsten, R&D is being carried out on various toroidal confinement devices. One particular research question is related to the optimum heating mix for ITER. To investigate the influence of the heating scheme on the release and transport of tungsten, a comparison of neutral beam injection (NBI) and ion cyclotron resonance frequency (ICRF) heating was carried out in TEXTOR tungsten test limiter experiments. The experiments were performed under standard L-mode conditions and in radiative improved-mode operation with neon seeding and boronized walls covering the graphite plasma-facing components. The plasma was heated with hydrogen or deuterium NBI alone or with deuterium NBI in combination with H-minority, ion cyclotron resonance heating. A movable solid tungsten limiter was inserted through a limiter lock system into the edge plasma. The impurity release from this limiter was evaluated from visible spectroscopy. The tungsten concentrations in the plasma core were determined by extreme ultraviolet spectroscopy and bolometry. With deuterium NBI alone, strong central radiation and accumulation of W was observed. This can, however, be avoided by adding ICRF heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION

Evidence of electron microbunching in laser-driven modulated downramp injection and prospects for beam-driven implementation

Plasma accelerators can generate high-energy, high-brightness electron beams over centimeter-scale distances, offering novel pathways to compact x-ray free-electron lasers. Generating beams pre-bunched at the desired radiation wavelength would significantly enhance longitudinal coherence and reduce saturation length. Plasma density-modulated downramp injection offers an in-situ way to generate such beams with nanometer-scale bunching. Here we report the first experimental evidence of this mechanism in a laser-driven wakefield accelerator, showing that modulated density downramps generate modulated electron energy spectra absent in unmodulated cases. Particle-in-cell simulations reproduce these observations and reveal bunching factors of 0.05 at 0.4 μm, with a compression factor of approximately 7. Building on this demonstration, we propose a beam-driven implementation for FACET-II to generate multi-GeV beams pre-bunched at hundreds of nanometers wavelength, with sub-micrometer emittance, kiloampere peak current, and sub-percent slice energy spread. Two-stage magnetic compression enables tunable bunching from optical to extreme ultraviolet wavelengths while achieving peak currents exceeding 100 kA. Coherent transition radiation calculations confirm diagnostic feasibility. This approach offers a promising path towards compact, high-energy pre-bunched electron sources for advanced photon science applications.

electron microbunching

Energetic Electrons Accelerated and Trapped in a Magnetic Bottle above a Solar Flare Arcade

Where and how flares efficiently accelerate charged particles remains an unresolved question. Recent studies revealed that a “magnetic bottle” structure, which forms near the bottom of a large-scale reconnection current sheet above the flare arcade, is an excellent candidate for confining and accelerating charged particles. However, further understanding its role requires linking the various observational signatures to the underlying coupled plasma and particle processes. Here we present the first study combining multiwavelength observations with data-informed macroscopic magnetohydrodynamics and particle modeling in a realistic eruptive flare geometry. The presence of an above-the-loop-top magnetic bottle structure is strongly supported by the observations, which feature not only a local minimum of magnetic field strength but also abruptly slowing plasma downflows. It also coincides with a compact above-the-loop-top hard X-ray source and an extended microwave source that bestrides the flare arcade. Spatially resolved spectral analysis suggests that nonthermal electrons are highly concentrated in this region. Our model returns synthetic emission signatures that are well matched to the observations. The results suggest that the energetic electrons are strongly trapped in the magnetic bottle region due to turbulence, with only a small fraction managing to escape. The electrons are primarily accelerated by plasma compression and facilitated by a fast-mode termination shock via the Fermi mechanism. Our results provide concrete support for the magnetic bottle as the primary electron acceleration site in eruptive solar flares. They also offer new insights into understanding the previously reported small population of flare-accelerated electrons entering interplanetary space.

79 ASTRONOMY AND ASTROPHYSICS

Effects of Proton Irradiation on the Performance of Skipper CCDs

Skipper CCDs are a mature detector technology that has been suggested for future space telescope instruments requiring sub-electron readout noise in the near-ultraviolet to the near-infrared. While modern skipper CCDs inherit from the radiation-tolerant p-channel detectors developed by LBNL, the effects of high doses of ionizing radiation on skipper CCDs (such as those expected in space) remains largely unmeasured. We report preliminary results on the performance of p-channel skipper CCDs following irradiation with 217-MeV protons at the Northwestern Medicine Proton Center. The total nonionizing energy loss (NIEL) experienced by the detectors exceeds 6 years at the Sun-Earth Lagrange Point 2 (L2). We demonstrate that the skipper amplifier continues to function as expected following this irradiation. Owing to the low readout noise of these detectors, controlled irradiation tests can be used to sensitively characterize the charge transfer inefficiency, dark current, and the density and time constants of charge traps as a function of proton fluence. We conclude with a brief outlook toward future tests of these detectors at other proton and gamma-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Scintillation of colloidal nanocrystals

Scintillators are materials that convert ionizing radiation in the form of particles or photons into low-energy photons in the ultraviolet to near-infrared spectral range. Here, this work reviews efforts to use colloidal nanocrystals as scintillator materials. To date, research on colloidal nanocrystals as scintillators has focused on doped phosphor systems, quantum dots and related structures, and perovskite-based nanocrystals. Among various material classes and forms, colloidal semiconductor nanocrystals stand out thanks to their appealing fluorescence properties, yet understanding of their radioluminescence and cathodoluminescence is incomplete. This review discusses fundamental limits and material design challenges toward achieving high brightness, fast speed, and durable scintillator performance with nanocrystal scintillators. First, this review describes the basic principles and efficiency limitations of scintillation, particularly the large influence of multiple exciton generation in many nanocrystal species, as well as performance metrics. Second, methods for measurement are described. Third, we review the results of the main classes of nanocrystal scintillators, including quantum dots and related particles, perovskites, and doped-phosphor particles. Fourth, scintillation imaging is discussed in terms of the relevant performance metrics and results obtained using nanocrystal materials. Finally, we note the strengths and weaknesses of nanocrystal scintillators and discuss potential areas of further development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Progress in the development of an ultrafast pulsed ponderomotive phase plate for cryo-electron tomography

Cryo-electron tomography (cryo-ET) is a powerful modality for resolving cellular structures in their native state. While single-particle cryo-electron microscopy excels in determining protein structures purified from recombinant or endogenous sources due to an abundance of particles, weak contrast issues are accentuated in cryo-ET by low copy numbers in crowded cellular milieux. Continuous laser phase plates offer improved contrast in cryo-ET; however, their implementation demands exceptionally high-peak optical intensities. Instead, a novel experimental approach to enhance contrast in cryo-ET is to manipulate the phase of scattered pulsed electrons using ultrafast pulsed photons. Here, we outline the experimental design of a proof-of-concept electron microscope and demonstrate synchronization between electron packets and laser pulses. Furthermore, we show ultrabright photoemission of electrons from an alloy field emission tip using femtosecond ultraviolet pulses. These experiments pave the way toward exploring the utility of the ponderomotive effect using pulsed radiation to increase phase contrast in cryo-ET of subcellular protein complexes in situ, thus advancing the field of cell biology.

Du, Daniel X. [Columbia Univ., New York, NY (Unite

Downwelling Shortwave and Longwave Irradiance from CC-RIDER on Mount Soledad

The Clouds and Climate - Remote Integrated Deployment of Radiometers (CC-RIDER) is a suite of five Eppley Laboratory (Inc.) instruments that was deployed during EPCAPE at the secondary Mount Soledad site in La Jolla, CA. A primary and backup Precision Spectral Pyranometer (PSP Primary, PSP Backup) measured broadband downwelling shortwave irradiance in the spectral interval 280-2800 nm. A third Precision Spectral Pyranometer (PSP NIR) was fitted with a near-infrared long pass filter and measured downwelling shortwave irradiance in the spectral interval 780-2800 nm. A Total Ultraviolet Radiometer (TUVR) measured broadband downwelling broadband ultraviolet irradiance in the spectral interval 295-385 nm. A Precision Infrared Radiometer (PIR) Pyrgeometer measured downwelling broadband longwave irradiance in the spectral interval 3.5 - 50 microns. Data collection began on 18 April 2023 at 21:31 UTC and ended on 20 February 2024 at 22:34 UTC. Data were recorded by a Campbell Scientific (Inc.) CR1000X datalogger in one-minute intervals, for a total of 443584 data records. The datalogger was solar powered enabling data collection to proceed without interruption from start to finish.

Clouds and Climate – Remote Integrated DEployement

Poincaré beams from a free electron laser

Poincaré beams are light beams that have spatially inhomogeneous polarization structure that spans a finite portion of the Poincaré sphere. This feature bestows the beams with intriguing topological properties and has led to a surge in research on their fundamental characteristics, their controlled generation and on emerging applications. Here we present an experimental demonstration of a Poincaré beam generated in the extreme ultraviolet (16.7 nm) at the FERMI free electron laser (FEL). The ‘star’ type Poincaré beam is generated by exploiting the phase and intensity structure intrinsic to FEL radiation without relying on optical elements. Here, we controlled the spatial polarization distribution through a precise overlap and power balance between two FEL pulses, each with different transverse phase distributions and orthogonal circular polarizations. The spatial polarization structure was mapped in detail and shows extensive coverage of the Poincaré sphere, in agreement with analytic predictions. This method of in situ Poincaré beam production in FELs enables straightforward flexibility in the orientation and balance of polarization states, and can readily be extended to other vector beams and to shorter wavelengths enabling novel science applications in modern light sources.

Morgan, Jenny [SLAC National Accelerator Laborator

Metal ion dopant-induced famatinite to chalcostibite phase transformation of copper antimony sulphide colloidal nanostructures: effect on photophysical and pseudocapacitance properties

Here, the strategic doping of transition metal ions into copper antimony sulphide (CAS) semiconducting nanostructures can significantly influence their photophysical and pseudocapacitive properties, for which there are few reports and therefore is the focus of this study. Accordingly, highly crystalline metal ion (Mn 2+ , Fe 2+ , Co 2+ , Ni 2+ and Zn 2+ ) doped off-stoichiometric copper rich/poor, antimony-rich/poor, and sulphur-poor CAS nanostructures (10–23 nm) were grown via colloidal (hot-injection) synthesis using metal diethyldithiocarbamate precursors. Importantly, metal ion doping significantly influences the structure and composition of the off-stoichiometric CAS nanostructures. Data from powder X-ray diffraction, Raman spectroscopy, high-resolution scanning/transmission electron microscopy, and energy dispersive X-ray spectroscopy confirm that the heavier metal ion dopants induce a novel phase transformation from famatinite (fCAS) to chalcostibite (cCAS) nanostructures. The influence of the metal ion dopants is also observed in the optical properties of as-synthesized nanostructures. This involves blue-shifted ultraviolet-visible absorption, reduced Urbach tailing, and tunable bandgaps between 2.17 and 2.38 eV. Also, the doped nanostructures display broad visible-near infrared photoluminescence via a triple radiative pathway with relatively short decay lifetimes between 0.2 and 6.1 ns. This is mediated by electronic transitions involving intrinsic (copper/antimony/sulphur interstitial) and extrinsic (metal ion interstitial) defect states. Additionally, electrodes prepared from Mn 2+ -doped fCAS nanostructures show enhanced pseudocapacitance via Na+ surface adsorption and intercalation relative to undoped fCAS electrodes, while Zn 2+ -doped cCAS electrodes exhibit pseudocapacitance via a combination of Na+ surface adsorption, intercalation, and redox reactions. These electrodes exhibit reduced charge transfer resistance, improved electronic conductivity and notably enhanced specific capacitance (∼222 F g −1 ), and charge transport, as measured in 1 M Na 2 SO 4 electrolyte via cyclic voltammetry and electrochemical impedance spectroscopy. To this end, the discovery of the metal ion-induced phase transformation presents a new avenue for optimizing the functional properties of fCAS and cCAS nanostructures, highlighting the critical role of metal ion-related defects in controlling the optical and electrochemical properties, towards potential solar absorption and energy storage applications.

25 ENERGY STORAGE

VERITAS and Multiwavelength Observations of the Blazar B3 2247+381 in Response to an IceCube Neutrino Alert

While the sources of the diffuse astrophysical neutrino flux detected by the IceCube Neutrino Observatory are still largely unknown, one of the promising methods to improve our understanding of them is investigating the potential temporal and spatial correlations between neutrino alerts and the electromagnetic radiation from blazars. We report on the multiwavelength target-of-opportunity observations of the blazar B3 2247+381, taken in response to an IceCube multiplet alert for a cluster of muon neutrino events compatible with the source location between 2022 May 20 and 2022 November 10. B3 2247+381 was not detected with VERITAS during this time period. The source was found to be in a low-flux state in the optical, ultraviolet, and gamma-ray bands for the time interval corresponding to the neutrino event, but was detected in the hard X-ray band with NuSTAR during this period. We find the multiwavelength spectral energy distribution is described well using a simple one-zone leptonic synchrotron self-Compton radiation model. Moreover, assuming the neutrinos originate from hadronic processes within the jet, the neutrino flux would be accompanied by a photon flux from the cascade emission, and the integrated photon flux required in such a case would significantly exceed the total multiwavelength fluxes and the VERITAS upper limits presented here. The lack of flaring activity observed with VERITAS, combined with the low multiwavelength flux levels, as well as the significance of the neutrino excess being at a 3σ level (uncorrected for trials), makes B3 2247+381 an unlikely source of the IceCube multiplet. We conclude that the neutrino excess is likely a background fluctuation.

79 ASTRONOMY AND ASTROPHYSICS