Search NASA⌕ Search

SEARCH · Search NASA

Results for “UPPER AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Field demonstration of a tracer method to track simulated exhaled air trajectories and mixing in three connected rooms with upper-room GUV

We conducted tracer gas experiments in three connected nursery rooms to track simulated exhaled air trajectories and mixing. We emulated exhaled air with a pulse release of ethanol and measured its concentration with 2s time resolution with spatially distributed metal oxide sensors in both the upper and occupied levels of the room. We found that the overhead cooling supply air enhanced vertical air mixing within the rooms. When a room had higher supply airflow than the others, the tracer gas mixed quickly in that room because the supply air dominated the room mixing, thereby isolating it from air mixing with the other rooms. When the forced air system was not operating, the tracer gas resided longer in the upper room before descending. The tracer method also depicts air trajectories from different release locations by detecting the release point and affecting nearby sensors. These experiments support the potential of this method to be used in the field for understanding air trajectories in rooms with upper-room GUV.

Um, Chai Yoon↗

Use Attainability Analysis for Upper Sandia Canyon

This document presents a use attainability analysis (UAA) for the perennial segment of Upper Sandia Canyon, which is located within the Los Alamos National Laboratory (LANL) property near Los Alamos, New Mexico.1 This UAA is consistent with 20.6.4.15 New Mexico Administrative Code (NMAC) (New Mexico Environment Department [NMED] 2011c), which describes the perennial segment as “Sandia Canyon from Sigma Canyon upstream to LANL [National Pollutant Discharge Elimination System] NPDES outfall 001.” The perennial segment’s designated uses are coldwater aquatic life, livestock watering, wildlife habitat, and secondary contact. 40 Code of Federal Regulations (CFR) § 131.10(g) permits a state to remove a designated use that is not an existing use (as defined in 40 CFR §131.3), if a UAA demonstrates that naturally occurring pollutant concentrations prevent the attainment of the use or if physical conditions related to the natural features of the water body preclude the attainment of the aquatic life protection use. This UAA considers whether natural physical conditions in Upper Sandia Canyon, specifically air and/or water temperatures, prevent the designated aquatic life use water temperature limits (i.e., coldwater) from being attained in the perennial segment. The weight of evidence presented in this UAA supports the conclusion that, based on air-water temperature modeling and instream thermograph data, the coolwater aquatic life designated use is currently the attainable use. Accordingly, it is recommended that the coolwater aquatic life designated use replace the coldwater aquatic life designated use in the Upper Sandia Canyon assessment unit (AU).

54 ENVIRONMENTAL SCIENCES↗

On the Relationship Between the Marine Cold Air Outbreak M Parameter and Low-Level Cloud Heights in the Midlatitudes

Focusing on conditions of subsidence when low clouds are present, ground-based observations in both the North Atlantic and the Southern Ocean reveal strong relationships between cloud boundary (base and top heights) and different measures of lower tropospheric instability. The difference in potential temperature between the surface and 800 hPa (a metric called M) provides a stronger relationship than measures of inversion strength such as the lower tropospheric stability and estimated inversion strength. This is because (1) inversion strength itself does not correlate well with cloud boundaries, and (2) M contains information that appears important for cloud boundaries. These include the surface forcing through the use of sea surface rather than near-surface air temperature and an upper level close to the real cloud top. These results expand upon previous work on the importance of M as a predictor of cloud morphology. However, important differences are found in low-cloud conditions for the North Atlantic as compared to the Southern Ocean (for a given value of M): stronger inversions, deeper boundary layers, and much larger sea level pressures. Therefore, the relationship between cloud boundaries and M differs between the two regions. A general circulation model provides similar relationships as observed between M and both cloud top height and temperature but tends to place clouds higher and at colder temperatures than observed for a given M. This might cause issues with the representation of precipitation, cloud cover and radiation in the Southern Ocean.

54 ENVIRONMENTAL SCIENCES↗

More Realistic Intermediate Depth Dry Firn Densification in the Energy Exascale Earth System Model (E3SM)

Abstract Earth system models account for seasonal snow cover, but many do not accommodate the deeper snowpack on ice sheets (aka firn) that slowly transforms to ice under accumulating snowfall. To accommodate and resolve firn depths of up to 60 m in the Energy Exascale Earth System Model's land surface model (ELM), we add 11 layers to its snowpack and evaluate three dry snow compaction equations in multi‐century simulations. After comparing results from ELM simulations (forced with atmospheric reanalysis) with empirical data, we find that implementing into ELM a two‐stage firn densification model produces more accurate dry firn densities at intermediate depths of 20–60 m. Compared to modeling firn using the equations in the (12 layer) Community Land Model (version 5), switching to the two‐stage firn densification model (with 16 layers) significantly decreases root‐mean‐square errors in upper 60 m dry firn densities by an average of 41 kg m −3 (31%). Simulations with three different firn density parameterizations show that the two‐stage firn densification model should be used for applications that prioritize accurate upper 60 m firn air content (FAC) in regions where the mean annual surface temperature is greater than roughly −31°C. Because snow metamorphism, firn density, and FAC are major components in modeling ice sheet surface albedo, melt water retention, and climatic mass balance, these developments advance broader efforts to simulate the response of land ice to atmospheric forcing in Earth system models.

58 GEOSCIENCES↗

The Extraordinary March 2022 East Antarctica “Heat” Wave. Part I: Observations and Meteorological Drivers

Abstract Between 15 and 19 March 2022, East Antarctica experienced an exceptional heat wave with widespread 30°–40°C temperature anomalies across the ice sheet. This record-shattering event saw numerous monthly temperature records being broken including a new all-time temperature record of −9.4°C on 18 March at Concordia Station despite March typically being a transition month to the Antarctic coreless winter. The driver for these temperature extremes was an intense atmospheric river advecting subtropical/midlatitude heat and moisture deep into the Antarctic interior. The scope of the temperature records spurred a large, diverse collaborative effort to study the heat wave’s meteorological drivers, impacts, and historical climate context. Here we focus on describing those temperature records along with the intricate meteorological drivers that led to the most intense atmospheric river observed over East Antarctica. These efforts describe the Rossby wave activity forced from intense tropical convection over the Indian Ocean. This led to an atmospheric river and warm conveyor belt intensification near the coastline, which reinforced atmospheric blocking deep into East Antarctica. The resulting moisture flux and upper-level warm-air advection eroded the typical surface temperature inversions over the ice sheet. At the peak of the heat wave, an area of 3.3 million km 2 in East Antarctica exceeded previous March monthly temperature records. Despite a temperature anomaly return time of about 100 years, a closer recurrence of such an event is possible under future climate projections. In Part II we describe the various impacts this extreme event had on the East Antarctic cryosphere. Significance Statement In March 2022, a heat wave and atmospheric river caused some of the highest temperature anomalies ever observed globally and captured the attention of the Antarctic science community. Using our diverse collective expertise, we explored the causes of the event and have placed it within a historical climate context. One key takeaway is that Antarctic climate extremes are highly sensitive to perturbations in the midlatitudes and subtropics. This heat wave redefined our expectations of the Antarctic climate. Despite the rare chance of occurrence based on past climate, a future temperature extreme event of similar magnitude is possible, especially given anthropogenic climate change.

Wille, Jonathan D.↗

Model predictive control for active insulation in building envelopes

Active insulation systems (AISs) refer to building envelopes with insulation materials that can change their thermal conductivity and are coupled with thermal mass to reduce building energy consumption and peak power. In this research, a novel optimal control approach is proposed to evaluate the maximum theoretical energy and cost-saving potential of AISs. A time-varying model predictive control (TV-MPC) controller was used to optimally select the AIS mode and simultaneously determine the operation of the heating, ventilation and air conditioning (HVAC) system so that the maximum saving potential of the entire system can be realized. To comprehensively evaluate the power shifting flexibility of AISs, two optimization objectives—minimizing weekly electric energy consumption and minimizing weekly electricity cost—were considered. The summer season simulation results show that under the first objective, more than 50% electric and thermal energy was saved when the upper boundary of the indoor air temperature was set to 25 °C. Furthermore under the second optimization objective, 38% of the cost was saved. It can be expected that the developed approach can be easily applied to multiple types of AISs with different mechanisms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flood Estimation under Snowmelt and Rain-on-Snow Processes in Alaska: A Military Installation Perspective

Accurate flood estimation in snow-dominated and high-latitude regions remains challenging due to complex interactions among rainfall, snowmelt, and rain-on-snow (ROS) processes, which are not captured in conventional precipitation-based intensity-duration-frequency (PREC-IDF) curves. This study evaluates the Next-Generation IDF (NG-IDF) framework, an extension of PREC-IDF that incorporates total water available for runoff (precipitation minus changes in snow water equivalent), in two contrasting Alaskan watersheds of Department of Defense (DoD) significance: the Little Chena River Basin (LCRB) in interior Alaska, a tributary of the Chena River that flows through Fort Wainwright and near Eielson Air Force Base, and the Upper Ship Creek Basin (USCB), which drains Joint Base Elmendorf-Richardson near Anchorage. Using long-term SNOTEL observations and event-based rainfall-runoff modeling, NG-IDF and PREC-IDF flood estimates were compared against observation-based flood frequency analyses. Results show that NG-IDF consistently reduces flood-estimation bias by 15–20% relative to PREC-IDF, particularly for snowmelt- and ROS-dominated events. In the interior LCRB, permafrost conditions can substantially amplify flood responses during snowmelt events, an effect not explicitly represented in standard design tools. These findings demonstrate that NG-IDF provides a more physically consistent and transferable framework for flood estimation in cold regions, with potential relevance to mission-critical DoD installation resilience. Projected increases in ROS frequency and permafrost degradation across Alaska further emphasize the need to integrate physics-based hydrologic models that explicitly represent snow and permafrost processes to enhance design resilience and operational readiness for military and other critical infrastructure.

Yan, Hongxiang (ORCID:000000022387403X)↗

Source Levels of In‐Cloud Air in Shallow Cumulus: Consistency Between Paluch Diagram and Lagrangian Particle Tracking

Abstract The Paluch diagram is a widely used tool for interpreting aircraft measurements of shallow cumulus clouds. A prior study conducted by Heus et al. (2008,https://doi.org/10.1175/2008jas2572.1) concluded that the source levels of in‐cloud air inferred from the Paluch diagram exhibit biases, sometimes of several hundred meters, in comparison to those derived from Lagrangian particle tracking. In this short study we revisit this comparison. The results indicate that the upper source levels of in‐cloud air determined from the Lagrangian Particle Tracking and the Paluch diagram are consistent, and the choice of statistical methods is crucial. The significance of this research lies in confirming the reliability of the Paluch analysis, enabling its confident application to aircraft data.

Meteorology & Atmospheric Sciences↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Upper troposphere dust belt formation processes vary seasonally and spatially in the Northern Hemisphere

Dust aerosols impact global energy balance substantially by acting as efficient ice nuclei to alter cold cloud properties. However, the estimate of dust indirect effect remains uncertain due to simulating dust distributions poorly and lacking reliable dust observations, especially in the upper-troposphere. Here, we characterize and understand upper-troposphere dust sources and transport with an improved dust dataset derived from A-train satellite lidar and radar measurements and an air parcel trajectory model. The distinct upper-troposphere dust belt over the northern hemisphere has seasonally varying base and top heights of 3.65 ± 2.84 and 8.35 ± 1.50 km above mean sea level and its column loading is strongest during spring (March-April-May). The out-of-phase annual cycles of mid-level dust concentration and westerly wind over source regions control the seasonal upper-tropospheric dust loading variations. African deserts contribute the most (46.3%) to the upper-troposphere dust belt in spring and the synoptic trough is the leading (49%) dust lifting mechanism.

54 ENVIRONMENTAL SCIENCES↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating the origin of the far-field reflection interference fringe (RIF) of microdroplets

We show that the reflection interference fringe (RIF) is formed on a screen far away from the microdroplets placed on a prism-based substrate, which have low contact angles and thin droplet heights, caused by the dual convex–concave profile of the droplet, not a pure convex profile. The geometric formulation shows that the interference fringes are caused by the optical path difference when the reflected rays from the upper convex profile at the droplet–air interface interfere with reflection from the lower concave profile at oblique angles lower than the critical angle. Analytic solutions are obtained for the droplet height and the contact angle out of the fringe number and the fringe radius in RIF from the geometric formulation. Furthermore, the ray tracing simulation is conducted using the custom-designed code. The geometric formulation and the ray tracing show excellent agreement with the experimental observation in the relation between the droplet height and the fringe number and the relation between the contact angle and the fringe radius. This study is remarkable as the droplet's dual profile cannot be easily observed with the existing techniques. However, the RIF technique can effectively verify the existence of a dual profile of the microdroplets in a simple setup. In this work, the RIF technique is successfully developed as a new optical diagnostic technique to determine the microdroplet features, such as the dual profile, the height, the contact angle, the inflection point, and the precursor film thickness, by simply measuring the RIF patterns on the far-field screen.

42 ENGINEERING↗

What Drives Upper-Ocean Temperature Variability in Coupled Climate Models and Observations?

Abstract A key question in climate modeling is to what extent sea surface temperature and upper-ocean heat content are driven passively by air–sea heat fluxes, as opposed to forcing by ocean dynamics. This paper investigates the question using a climate model at different resolutions, and observations, for monthly variability. At the grid scale in a high-resolution climate model with resolved mesoscale ocean eddies, ocean dynamics (i.e., ocean heat flux convergence) dominates upper 50 m heat content variability over most of the globe. For deeper depths of integration to 400 m, the heat content variability at the grid scale is almost totally controlled by ocean heat flux convergence. However, a strong dependence on spatial scale is found—for the upper 50 m of ocean, after smoothing the data to around 7°, air–sea heat fluxes, augmented by Ekman heat transports, dominate. For deeper depths of integration to 400 m, the transition scale becomes larger and is above 10° in western boundary currents. Comparison of climate model results with observations show that the small-scale influence of ocean intrinsic variability is well captured by the high-resolution model but is missing from a comparable model with parameterized ocean-eddy effects. In the deep tropics, ocean dynamics dominates in all cases and all scales. In the subtropical gyres at large scales, air–sea heat fluxes play the biggest role. In the midlatitudes, at large scales >10°, atmosphere-driven air–sea heat fluxes and Ekman heat transport variability are the dominant processes except in the western boundary currents for the 400 m heat content.

54 ENVIRONMENTAL SCIENCES↗

Aircraft-derived particle fluxes distinguish entrainment zone and decoupled layer nucleation in marine boundary layers

The vertical distribution of freshly nucleated aerosol particles in the marine boundary layer remains poorly constrained, limiting our ability to represent new particle formation in climate models. Here we characterize 3–10 nm particle events, termed small particle events (SPEs), by deriving their vertical turbulent fluxes from aircraft measurements during the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) campaign. To overcome stationarity limitations of traditional eddy covariance methods, we applied continuous wavelet transform analysis to data collected during June–July 2017 and January–February 2018 flights over the Azores. Our flux-based analysis revealed two distinct SPE scenarios with different vertical structures and spatial extents. The first featured nucleation in the entrainment zone, where free tropospheric air entrains into the boundary layer. The second showed nucleation in the decoupled layer, a stratified region between the well-mixed surface layer and cloud-topped upper boundary layer. In both cases, convergence of air masses from different layers diluted preexisting aerosol surface area to very low levels, creating conditions favorable for nucleation and generating strong downward particle fluxes. SPEs occurred in 15 % of flights, challenging prevailing theoretical expectations that new particle formation should rarely occur in marine boundary layers due to high condensation and coagulation sink capacity of sea spray aerosols. Aircraft-derived particle fluxes provide first observational constraints on the vertical location and source strength of likely nucleation regions in the remote marine boundary layer, improving aerosol source representations in climate models and reducing uncertainties in aerosol-cloud interactions.

Rasheeda Satheesh, Ajmal [North Carolina State Uni↗

Piston with insulating air gap formed by additive manufacturing

The present disclosure provides a piston, comprising: a skirt having an upper body portion; and a crown formed on the upper body portion by an additive manufacturing process, the crown including at least one air gap formed and positioned to reduce heat transfer from combustion to at least one cooling gallery formed in the piston.

Kelleher, Jordan E.↗

Piston with insulating air gap formed by additive manufacturing

The present disclosure provides a piston, comprising: a skirt having an upper body portion; and a crown formed on the upper body portion by an additive manufacturing process, the crown including at least one air gap formed and positioned to reduce heat transfer from combustion to at least one cooling gallery formed in the piston.

Kelleher, Jordan E.↗

Interannual variability and trends of summertime PM2.5-based air quality in the Intermountain West

Abstract Summertime air quality is a growing public health concern in the populated region of Northern Utah. Whereas winter air pollution is highly linked with local atmospheric temperature inversions associated with upper atmospheric high-pressure and radiational cooling in valleys, the relationship between climate factors and the frequency of poor air quality during summer is still unknown. Analyzing the last 20 years of data, we demonstrated that summertime unhealthy days (as defined by PM2.5 air quality index level) in Northern Utah highly correlate with the number of dry-hot days, wildfire size, and an upper atmospheric ridge over the Northwestern United States. The persistent atmospheric ridge enhances lightning-caused fire burned areas in northwestern states and then transports the wildfire smoke toward Northern Utah. Similarly, climate model simulations confirm observational findings, such as an increasing trend of the upper atmospheric ridge and summertime dry days in the northwestern states. Such metrics developed in this study could be used to establish longer-term monitoring and seasonal forecasting for air quality and its compounding factors, which is currently limited to forecasting products for only several days.

54 ENVIRONMENTAL SCIENCES↗

Air bearing apparatus for calibrating force measurement devices

An air bearing for calibrating a force measurement device comprises an inner wall, an outer wall, an upper wall, a lower wall, an internal chamber, an object retention opening, and a plurality of air outlets. The inner wall and outer wall each have a cylindrical shape with the outer wall being concentric with the inner wall. The upper wall and lower wall each have an annular shape and are attached to the inner wall and the outer wall. The internal chamber is formed by inner surfaces of the four walls, and is configured to retain compressed air. The object retention opening is formed by an outer surface of the inner wall and is configured to receive and retain an object. The air outlets are positioned along the inner wall and are configured to allow compressed air to flow from the internal chamber to the object retention opening.

Steuber, Jason↗