Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultrasound materials processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrical de-poling and re-poling of relaxor-PbTiO 3 piezoelectric single crystals without heat treatment

Re-poling of unexpected partially depoled piezoelectric materials conventionally needs to be first fully depoled through annealing above their Curie temperature to revive piezoelectric performances. Here, we investigated de-poling and re-poling of Pb(In 1/2 Nb 1/2 )O 3 -Pb(Mg 1/3 Nb 2/3 )O 3 -PbTiO 3 single crystals under electric fields at room temperature. We found that alternating current electric fields with amplitudes near the coercive field at low frequencies (<10 Hz) can be employed to successfully depolarize poled crystals at room temperature. We also demonstrated a reversible polarization switching process with a relaxor-PbTiO 3 single crystal ultrasound transducer without device performance degradations. This experimental observation is supported by phase-field simulation, showing that alternating current electric fields can readily induce de-poling at room temperature, while direct current electric fields induce a transient depoled state only within an uncontrollable short period of time. The findings suggest new strategies for unprecedented in-device tailoring of the polarization states of ferroelectric materials.

36 MATERIALS SCIENCE↗

A combination interferometric and morphological image processing approach to rapid quality assessment of additively manufactured cellular truss core components

Advanced manufacturing (AM) processes such as laser powder bed fusion (LPBF) are increasingly capable of fabricating components with useful and unprecedented mechanical properties by incorporating complex internal bracing structures. From the standpoint of quality control and assessment, however, internally complex assemblies present significant build-verification challenges. Here we propose a hybrid approach to the inspection involving the application of computer-aided speckle interferometry (CASI) and morphological image processing as a rapid, inexpensive, and facile method for AM quality control. The described methodology has low capital equipment costs, is full-field and non-contact, can be used in an industrial setting, and has very low requirements in terms of operator training and expertise. Consisting primarily of the combination of image processing software with a simple optical system of variable sensitivity, the method is shown to be effective for inspection of a titanium honeycomb component subjected to differential pressure. Results are compared to those achieved with computed tomography (CT), immersion ultrasound testing (UT), and optical holographic interferometry. Here we propose several possible processing strategies for automated quality assessment based on this powerful hybrid approach.

36 MATERIALS SCIENCE↗

Ultrasonic characterization of material heterogeneities in stainless steel components produced by laser powder bed fusion

We introduce pulse-echo ultrasound as a method for characterizing the impact of powder bed fusion parameters on the properties of additively manufactured stainless-steel components, their material anisotropy, and location-dependent heterogeneity. Our results indicate that accurate characterization requires careful selection of ultrasonic propagation paths, which must consider the direction of additive layering, variations in processing parameters, and the component's geometry. We employed two distinct methods to estimate material properties from ultrasonic data: One assumes isotropy, while the other accounts for anisotropic interactions during the propagation of elastic waves. When applied to samples fabricated with laser energy densities ranging from 24 to 42 J/mm³ , these methods revealed transverse isotropy and weak anisotropy (quantified by small Thomsen parameters, ε = 0.0651 and γ = 0.0092) and less than a ∼6 % change in acoustic impedance. The assumption of isotropy, in this case, leads to small errors (less than 4 % or 1 % for Young's modulus in the build or transverse directions) when estimating orthotropic material properties using ultrasonic data measured along just two orthogonal directions, one of which must align with the build direction. By comparing ultrasonic measurements — which aggregate the spatial variability in material properties along the length of elastic wave propagation into a single value — with localized measurements obtained from surface nanoindentation, we uncovered and spatially profiled significant differences between the surface and interior properties. Specifically, the surface Young's modulus decreased from approximately 210 GPa to 180 GPa within a depth of about 3 mm. We attribute this surface-localized heterogeneity in PBF-fabricated components to distinct thermal histories experienced by the surface and interior regions. Collectively, the results of this study establish a framework for the ultrasonic characterization of material heterogeneity and anisotropy in material properties and demonstrate its application in additively manufactured metal components.

36 MATERIALS SCIENCE↗

Data for: Ultrasonic characterization of material heterogeneities in stainless steel parts fabricated by powder bed fusion

These are the raw ultrasonic waveform files and nanoindentation measurements for three additively manufactured 316L stainless steel components with different fabrication parameters. Each part's length is divided into four segmented regions where their fabrication energy densities change. Part V+ begins at 33 J/mm^3 and increases in energy density by 3 J/mm^3 with each segment. Part C remains at a constant 33 J/mm^3 throughout the part. Part V- begins at 33 J/mm^3 and decreases in energy density by 3 J/mm^3 with each segment. We have found that the ultrasonic waves in regions with higher energy densities will traverse more quickly, as shown by the shorter time of flight, and vice versa. Similarly, nanoindentation measurements of reduced modulus and hardness follow this trend. We have measured the direction in which the parts were fabricated (build direction) and the segmented regions that are perpendicular to the build direction (transverse directions). The build direction longitudinal wave velocity measurements are considerably lower than their transverse direction counterparts, indicating anisotropy between the two directions. In Part C, we have removed material from one of its surfaces and recorded its ultrasonic and nanoindentation measurements with each material removal iteration. Changes in the material properties are more prominent by nanoindentation, suggesting material heterogeneity between the part's surface and interior. The README.txt file has information on how to navigate the files and process the data.

Anisotropy↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using Ultrasound and Braslet-M Occlusion Cuffs

The objective of this joint U.S. - Russian project was the development and validation of an in-flight methodology to assess a number of cardiac and vascular parameters associated with circulating volume and its manipulation in long-duration space flight. Responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound (US) before, during, and after temporary volume reduction by means of Braslet-M thigh occlusion cuffs (Russia). Materials and Methods: The study protocol was conducted in 14 sessions on 9 ISS crewmembers, with an average exposure to microgravity of 122 days. Baseline cardiovascular measurements were taken by echocardiography in multiple modes (including tissue Doppler of both ventricles) and femoral and jugular vein imaging on the International Space Station (ISS). The Braslet devices were then applied and measurements were repeated after >10 minutes. The cuffs were then released and the hemodynamic recovery process was monitored. Modified Valsalva and Mueller maneuvers were used throughout the protocol. All US data were acquired by the HDI-5000 ultrasound system aboard the ISS (ATL/Philips, USA) during remotely guided sessions. The study protocol, including the use of Braslet-M for this purpose, was approved by the ISS Human Research Multilateral Review Board (HRMRB). Results: The effects of fluid sequestration on a number of echocardiographic and vascular parameters were readily detectable by in-flight US, as were responses to respiratory maneuvers. The overall volume status assessment methodology appears to be valid and practical, with a decrease in left heart lateral E (tissue Doppler) as one of the most reliable measures. Increase in the femoral vein cross-sectional areas was consistently observed with Braslet application. Other significant differences and trends within the extensive cardiovascular data were also observed. (Decreased - RV and LV preload indices, Cardiac Output, LV E all maneuvers, LV Stroke Volume). Conclusions: This Study: 1) Addressed specific aspects of operational space medicine and space physiology, including assessment of circulating volume disturbances 2) Expanded the applications of diagnostic ultrasound imaging and Doppler techniques in microgravity. 3) Used respiratory maneuvers against the background of acute circulating volume manipulations which appear to enhance our ability to noninvasively detect volume-dependency in a number of cardiac and vascular parameters. 4) Determined that Tei index is not clinically changed therefore contractility not altered in the face of reduced preload. 5) Determined that increased Femoral Vein Area indicating blood being sequestered in lower extremities correlates with reduced preload and cardiac output. 6) That Braslet may be the only feasible means of acutely treating high pressure pulmonary edema in reduced gravity environments.

Hamilton, Douglas↗

Gradient process parameter optimization in additive friction stir deposition of aluminum alloys

As one of the most novel additive manufacturing methods, currently selection and optimization of processing parameters in additive friction stir deposition (AFSD) have mainly relied on experiments and subsequent characterization of microstructural and mechanical properties. Such approaches are both time- and resource-consuming. Therefore, an ultrasound elastography enhanced gradient process parameter optimization method was applied in the present work to obtain a window of optimized processing parameters for AFSD processing of aluminum alloy by varying both rotational and linear deposition speeds. Further, the quality of AFSD processed layer was investigated for physical nature of surface, dynamic elastic modulus, and microstructural aspects in cross-sections of the deposited layer. The efficiency in exploring process parameters was significantly enhanced by implementing a high-throughput screening experimental design based on application of gradient process parameters and continuous ultrasound elastographs. In addition, the applied ultrasonic elastography technique assisted in evaluating the homogeneity in microstructure and mechanical properties of AFSD sample over the entire gradients of the process parameters. The techniques adopted in current work can be further extended to identify suitable parameters for AFSD fabrication of components with desired mechanical properties such as hardness, fatigue, etc.

36 MATERIALS SCIENCE↗

The effect of ultrasonics on the strength properties of carbon steel processed by cold plastic deformation

A study was made of the influence of ultrasounds on the mechanical properties of OLT 35 carbon steel tubes cold-drawn on a plug ultrasonically activated by longitudinal waves. Experimental results indicate that: 1. The reduction in the values of the flow limit and tensile strength is proportional to the increase in acoustic energy introduced into the material subjected to deformation. 2. The diminution in influence of ultrasounds on tensile strength and flow rate that is due to an increased degree of deformation is explained by a reduction in specific density of the acoustic energy at the focus of deformation. 3. The relations calculated on the basis of the variation in the flow limit and tensile strength as a function of acoustic energy intensity was verified experimentally.

Atanasiu, N.↗

Ultrasound Thermal Field Imaging of Opaque Fluids

We have initiated an experimental program to develop an ultrasound system for non-intrusively imaging the thermal field in opaque fluids under an externally imposed temperature gradient. Many industrial processes involve opaque fluids, such as molten metals, semiconductors, and polymers, often in situations in which thermal gradients are important. For example, one may wish to understand semiconductor crystal growth dynamics in a Bridgman apparatus. Destructive testing of the crystal after the process is completed gives only indirect information about the fluid dynamics of the formation process. Knowledge of the coupled thermal and velocity fields during the growth process is then essential. Most techniques for non-intrusive velocity and temperature measurement in fluids are optical in nature, and hence the fluids studied must be transparent. In some cases (for example, LDV (laser Doppler velocimetry) and PIV (particle imaging velocimetry)) the velocities of small neutrally buoyant seed particles suspended in the fluid, are measured. Without particle seeding one can use the variation of the index of refraction of the fluid with temperature to visualize, through interferometric, Schlieren or shadowgraph techniques, the thermal field. The thermal field in turn gives a picture of the pattern existing in the fluid. If the object of study is opaque, non-optical techniques must be used. In this project we focus on the use of ultrasound, which propagates easily through opaque liquids and solids. To date ultrasound measurements have almost exclusively relied on the detection of sound scattered from density discontinuities inside the opaque material of interest. In most cases it has been used to visualize structural properties, but more recently the ultrasound Doppler velocimeter has become available. As in the optical case, it relies on seed particles that scatter Doppler shifted sound back to the detector. Doppler ultrasound techniques are, however, not useful for studying convective fluid flow in crystal growth, because particle seeding is unacceptable and flow velocities are typically too low to be resolved, and may be even lower in microgravity conditions where buoyancy forces are negligible. We will investigate a different use of ultrasound to probe the flows of opaque fluids non-intrusively and without the use of seed particles: our goal is to ultrasonically visualize the thermal field of opaque fluids with relatively high spatial resolution. The proposed technique relies upon the variation of sound speed with temperature of the fluid. A high frequency ultra-sound pulse passing through a fluid-filled chamber will traverse the chamber in a time determined by the relevant chamber dimension and the temperature of the fluid through which the pulse passes. With high time-resolution instrumentation that compares the excitation signal with the received pulse we can detect the influence of the fluid temperature on the pulse travel time. This is effectively an interferometric system, which in its optical form is an extremely sensitive approach to measuring thermal fields in fluids. Moreover, the temperature dependence of sound velocity in liquid metals is comparable to the temperature dependence of the speed of light required for accurate interferometric thermal images in transparent fluids. With an array of transducers scanned electronically a map of the thermal field over the chamber could be produced. An alternative approach would be to use the ultrasound analog of the shadowgraph technique. In the optical version, collimated light passes through the fluid, where it is focused or defocused locally by temperature field induced variations of the index of refraction. The resulting image reveals the thermal field through the spatial pattern of light intensity variations. By analogy, an ultrasound plane wave traversing an opaque fluid sample would be also locally focused or defocused depending on the speed of sound variations, giving rise to spatial variations in sound intensity that will reveal the thermal field pattern. These approaches could be applied to any situation in which temperature differences are expected to occur, and will rapidly provide information about the flow that simply cannot be obtained by any current intrusive or non-intrusive diagnostic technique. As materials processing in microgravity matures it will become increasingly important to have available simple and versatile diagnostic tools, such as we will develop, for studying the flows of opaque fluids under thermal forcing.

Andereck, C. David↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through-transmission mode using two transducers, or in pulse-echo mode. The transducer is a unique combination of material, design, and fabrication technique. It is based on single-crystal lead magnesium niobate lead titanate (PMN-PT) piezoelectric material. As compared to the commonly used piezoceramics, this piezocrystal has superior piezoelectric and elastic properties, which results in devices with superior bandwidth, source level, and power requirements. This design necessitates a single resonant frequency. However, by operating in a transverse length-extensional mode, with the electric field applied orthogonally to the extensional direction, resonators of different sizes can share common electrodes, resulting in a multiply-resonant structure. With carefully sized resonators, and the superior bandwidth of piezocrystal, the resonances can be made to overlap to form a smooth, wide-bandwidth characteristic.

Liang, Yu↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through transmission mode using two transducers, or in pulse-echo mode.

Liang, Yu↗

A Novel Continuous Ultrasound-Assisted Leaching Process for Rare Earth Element Extraction: Environmental and Economic Assessment

Rare earth elements (REEs) make up integral components in personal electronics, healthcare instrumentation, and modern energy technologies. REE leaching with organic acids is an environmentally friendly alternative to traditional extraction methods. Our previous study demonstrated that batch ultrasound-assisted organic acid leaching of REEs can significantly decrease environmental impacts compared to traditional bioleaching. The batch method is limited to small volumes and is unsuitable for industrial implementation. This study proposes a novel approach to increase reaction volume using a continuous ultrasound-assisted organic acid leaching method. Laboratory experiments showed that continuous ultrasound-assisted leaching increased the leaching rate (µg/h) 11.3–24.5 times compared to our previously reported batch method. Techno-economic analysis estimates the cost of the continuous approach using commercially purchased organic acids is $\$$9465/kg of extracted REEs and $\$$4325/kg of extracted REEs, using gluconic acid and citric acid, respectively. The sensitivity analysis reveals that substituting commercially purchased organic acids with microbially produced biolixiviant can reduce the process cost by approximately 99% while minimally increasing energy consumption. Environmental assessment shows that most of the emissions stemmed from the energy required to power the ultrasound reactor. We concluded that increased leaching capacity using a continuous ultrasound-assisted approach is feasible, but process modifications are needed to reduce the environmental impact.

54 - ENVIRONMENTAL SCIENCES/GLOBAL CLIMATE CHANGE ↗

Ultrasonic waveguide reflectometry for quench detection (CRADA Final Report)

Early detection of thermal runaway (quench) is critical for safely operating high-temperature superconductor (HTS) magnets. Voltage-based techniques provide late detection of quenching in HTS, which can lead to magnet burnout and system damage. Various non-voltage quench-detection approaches are therefore investigated nowadays that are based on magnetic, acoustic, and optical sensing. LBNL has been actively developing the quench detection principle based on diffuse ultrasonic wave propagation since 2017 and has demonstrated the approach's viability with several peer-reviewed publications and a patent application. Over the last decade, Etegent, LBNL partner for this proposal and effort, has been developing a sensing technology that utilizes the propagation of stress waves through the solid metallic and nonmetallic waveguides (WG). The method is based on the dependence of materials' elastic properties and the speed of sound on temperature. Compared with optical analog, acoustic WG operates at much lower frequencies, eliminating the need for expensive, complex, highly sensitive receivers and data processing. Etegent proved this technology in many harsh environments, mainly concentrated high-temperature measurements. The initial contact between LBNL and Etegent started in 2020, aiming at combining our knowledge and effort toward developing a viable ultrasound-based quench detection technique for use with HTS magnets. A preliminary study conducted jointly in 2022 found no principle restrictions for expanding the WG technology toward cryogenic temperature operation. The present CRADA work aimed at designing, building, and testing ultrasonic waveguide temperature sensors at relevant cryogenic conditions, and demonstrating this technology's applicability to detecting heating and quenching in High Temperature Superconductor (HTS)-based cables and magnets. The technical objectives of the project included: (1) Design and fabricate ultrasonic WG sensors suitable for cryogenic operation, (2) Test ultrasonic WGs under cryogenic conditions, (3) Determining a suitable way of insulating WGs to prevent ultrasonic leakage while maintaining good thermal contact with the surrounding medium, (4) WG integration and cryogenic test with HTS conductors and HTS magnets, and (5) Design and basic prototyping of a standalone WG-based quench detection system. This project adds value to the present LBNL magnet diagnostics portfolio and enables a breakthrough in addressing the HTS magnet quench detection challenge.

47 OTHER INSTRUMENTATION↗

Ultrasonic NDE Simulation for Composite Manufacturing Defects

The increased use of composites in aerospace components is expected to continue into the future. The large scale use of composites in aerospace necessitates the development of composite-appropriate nondestructive evaluation (NDE) methods to quantitatively characterize defects in as-manufactured parts and damage incurred during or post manufacturing. Ultrasonic techniques are one of the most common approaches for defect/damage detection in composite materials. One key technical challenge area included in NASA's Advanced Composite's Project is to develop optimized rapid inspection methods for composite materials. Common manufacturing defects in carbon fiber reinforced polymer (CFRP) composites include fiber waviness (in-plane and out-of-plane), porosity, and disbonds; among others. This paper is an overview of ongoing work to develop ultrasonic wavefield based methods for characterizing manufacturing waviness defects. The paper describes the development and implementation of a custom ultrasound simulation tool that is used to model ultrasonic wave interaction with in-plane fiber waviness (also known as marcelling). Wavefield data processing methods are applied to the simulation data to explore possible routes for quantitative defect characterization.

Leckey, Cara A. C.↗

Development and Validation of Quantitative Model-Based Image Reconstruction for NDE of Reinforced Steel-Lined Concrete Structures: Kal-El FY 2020

This project studied the capabilities of Model-Based Image Reconstruction (MBIR) and Machine Learning (ML) algorithms in the imaging and estimation of rebar corrosion from ultrasound signals. The application was challenging due to the introduction of a steel liner between the sensor and the concrete containing the rebar. The study focused in a synthetic specimen with a 6.35 mm thick steel liner, and a 19.05 mm diameter rebar at a depth of 44.5 mm and with four levels of corrosion; 0%, 20%, 50%, and 100% corrosion level. The corrosion was applied uniformly around the rebar, generating a ring in the perimeter of the rebar with different acoustic density. In order to generate a realistic synthetic dataset, we added random texture to the concrete of the synthetic specimens. This texture will mimic the variations encountered in real concrete specimens.We adapted our MBIR algorithm for the application and enhanced the algorithm to integrate in the physical model known specimen features, such as the steel liner thickness. The new MBIR method was able to cancel out reverberation from the steel liner and properly image the rebar. In particular, corrosion for the 50% and 100% cases were easily visible and quantitative metrics showed a slight separation for the 0% and 20% levels. The quantitative results were in agreement with the qualitative assessment. We also developed a ML XGBoost model to estimate corrosion level from the ultrasound signals. By combining the ML method with MBIR, we can pinpoint in the ultrasound signals the section that corresponds to the echoes from the rebar. The extract signals are processed by the XGBoost model for prediction. From each system scan, we obtain 15 predictions. The median prediction value is used as the final prediction. The True Acceptance Rate for the method is over 99%.

36 MATERIALS SCIENCE↗

The role of fast and slow dynamics in nonlinear resonant ultrasound spectroscopy of consolidated granular materials

Abstract Elastic nonlinearity observed in consolidated granular media can be attributed to the combination of slow and fast effects, which give rise to hysteresis and relaxation of both modulus and damping after the sample is perturbed. A consequence is a high level of complexity in the measurements of the sample linear and nonlinear elastic parameters. The results of experiments are dependent on the experimental protocol that is adopted to measure the relevant quantities and it is hard to quantify parameters with accuracy and repeatability. Here we focus on examining Nonlinear Resonant Ultrasound Spectroscopy, showing experimentally the role of slow dynamics in the process and quantifying/discussing its influence on the quantification of nonlinearity. We also propose a model to describe the process, which shows that different contributions to nonlinearity (e.g., classical and hysteretic) could be due to physical features (defects) relaxing with different relaxation times.

Science & Technology - Other Topics↗

Nondestructive ultrasonic characterization of a triple-weld-bead wire arc additively manufactured ER70S-6 S-curved wall

Understanding build-scale microstructural variation in wire arc additive manufacturing (WAAM) of low-carbon steels is essential for ensuring consistent structure–property relationships throughout large components. Conventional destructive characterization techniques, such as scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD), are time-intensive and limited to localized regions, making comprehensive evaluation of large WAAM structures challenging. In this study, a nondestructive ultrasonic approach was employed to characterize a 252 mm tall ER70S-6 S-curved WAAM wall produced using a triple-bead deposition strategy. Optical and SEM analysis revealed a repeating dual-region microstructure consisting of uniform polygonal ferrite at melt pool centers and heterogeneous ferrite with coarse and fine grains near melt pool boundaries, attributed to cyclic thermal conditions. Longitudinal ultrasonic backscatter imaging was used to evaluate the continuity of this periodicity along the full build height. The ultrasonic response exhibited a consistent repeating pattern that correlated with the observed layer-wise microstructural variation. X-ray computed tomography confirmed the absence of detectable porosity, indicating that ultrasonic contrast is primarily governed by grain morphology. Overall, the results indicate that longitudinal backscatter ultrasound is a promising nondestructive characterization technique for validating microstructural variations along the s-curved WAAM wall, with significant potential for microstructure optimization and process control.

36 MATERIALS SCIENCE↗

Applications of aerospace technology in biology and medicine

Utilization of NASA technology and its application to medicine is discussed. The introduction of new or improved commercially available medical products and incorporation of aerospace technology is outlined. A biopolar donor-recipient model of medical technology transfer is presented to provide a basis for the methodology. The methodology is designed to: (1) identify medical problems and NASA technology that, in combination, constitute opportunities for successful medical products; (2) obtain the early participation of industry in the transfer process; and (3) obtain acceptance by the medical community of new medical products based on NASA technology. Two commercial transfers were completed: the ocular screening device, a system for quick detection of vision problems in preschool children, and Porta-Fib III, a hospital monitoring unit. Two institutional transfers were completed: implant materials testing, the application of NASA fracture control technology to improve reliability of metallic prostheses, and incinerator monitoring, a quadrupole mass spectrometer to monitor combustion products of municipal incinerators. Mobility aids for the blind and ultrasound diagnosis of burn depth are also studied.

Rouse, D. J.↗