Search NASA⌕ Search

SEARCH · Search NASA

Results for “Urban thermal environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

32 records · Page 2

NASA's surface biology and geology designated observable: A perspective on surface imaging algorithms

The 2017-2027 National Academies' Decadal Survey, Thriving on Our Changing Planet, recommended Surface Biology and Geology (SBG) as a "Designated Targeted Observable" (DO). The SBG DO is based on the need for capabilities to acquire global, high spatial resolution, visible to shortwave infrared (VSWIR; 380 - 2500 nm; ~30 m pixel resolution) hyperspectral (imaging spectroscopy) and multispectral midwave and thermal infrared (MWIR: 3-5 µm; TIR: 8-12 µm; ~60 m pixel resolution) measurements with sub-monthly temporal revisits over terrestrial, freshwater, and coastal marine habitats. To address the various mission design needs, an SBG Algorithms Working Group of multidisciplinary researchers has been formed to review and evaluate the algorithms applicable to the SBG DO across a wide range of Earth science disciplines, including terrestrial and aquatic ecology, atmospheric science, geology, and hydrology. Here, we summarize current state-of-the-practice VSWIR and TIR algorithms that use airborne or orbital spectral imaging observations to address the SBG DO priorities identified by the Decadal Survey: (i) terrestrial vegetation physiology, functional traits, and health; (ii) inland and coastal aquatic ecosystems physiology, functional traits, and health; (iii) snow and ice accumulation, melting, and albedo; (iv) active surface composition (eruptions, landslides, evolving landscapes, hazard risks); (v) effects of changing land use on surface energy, water, momentum, and carbon fluxes; and (vi) managing agriculture, natural habitats, water use/quality, and urban development. We review existing algorithms in the following categories: snow/ice, aquatic environments, geology, and terrestrial vegetation, and summarize the community-state-of-practice in each category. Finally, this effort synthesizes the findings of more than 130 scientists.

54 ENVIRONMENTAL SCIENCES↗

Land-Surface Temperature Transitions at the Bankhead National Forest (LASTT-BNF) Field Campaign Report

Land surface types that are common in the Southeast United States (e.g., forests, agriculture, urban) can play key roles in the regulation of surface-atmosphere energy exchange and boundary-layer evolution in the region (Hinkle et al. 2024). Heterogeneity in these land-surface types and associated emissivities can drive strong transitions in land surface temperature (LST), which is an important component of the surface energy balance. Within the forested canopy surrounding the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s field deployment at the Bankhead National Forest (BNF) in Alabama main site (M1) (Kuang et al. 2026), the different components of the vegetation and ground surface can create strong gradients in surface temperature that can influence the canopy thermal environment and vegetative function (e.g., stress, transpiration), both of which can have important, yet poorly characterized, controls on lower atmospheric processes (e.g., thermal turbulence, secondary circulations).

54 ENVIRONMENTAL SCIENCES↗

PurpleAir Sensors as Effective Indicators of PM Exposure in Urban Areas

Particulate matter that is 2.5 microns or less in diameter (PM 2.5 ) is a biproduct of combustion reactions used for energy production. Populations that are exposed to consistently high levels of aerosolized PM 2.5 face serious health risks. This project compared low-cost PM 2.5 sensors with federally recognized methods to look for a cost-effective way to expand the air quality monitor network. Within metropolitan areas that face inconsistent spatial distribution of PM 2.5 , there may not be the necessary network density to indicate neighborhood-levels of PM 2.5 . This project aimed to examine the sensitivity of low-cost PM 2.5 sensor measurements on a neighborhood scale (< 4 km diameter) in an urban area to prevent citizens from being exposed to unsafe levels of PM 2.5 without their knowledge. Using publicly available sensor data from Livermore, CA and Bakersfield, CA, it was determined, based on the revealed patterns, that the analyzed low-cost sensors were able to display representative PM 2.5 levels for neighborhoodscale areas exposed to pollution from PM 2.5 sources.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Urban Acoustic Noise in the Las Vegas, NV Region

Ambient infrasound noise in quiet, rural environments has been extensively studied and well-characterized through noise models for several decades. More recently, creating noise models for high-noise rural environments has also become an area of active research. However, far less work has been done to create generalized low-frequency noise models for urban areas. The high ambient noise levels expected in cities and other highly populated areas means that these environments are regarded as poor locations for acoustic sensors, and historically, sensor deployment in urban areas were avoided for this reason. However, there are several advantages to placing sensors in urban environments, including convenience of deployment and maintenance, and increasingly, necessity, as more previously rural areas become populated. This study seeks to characterize trends in low-frequency urban noise by creating a background noise model for Las Vegas, NV, using the Las Vegas Infrasound Array (LVIA): a network of eleven infrasound sensors deployed throughout the city. Data included in this study spans from 2019 to 2021 and provides a largely uninterrupted record of noise levels in the city from 0.1–500 Hz, with only minor discontinuities on individual stations. We organize raw data from the LVIA sensors into hourly power spectral density (PSD) averages for each station and select from these PSDs to create frequency distributions for time periods of interest . These frequency distributions are converted into probability density functions (PDFs), which are then used to evaluate variations in frequency and amplitude over daily to seasonal timescale s. In addition to PDFs, the median, 5 th percentile, and 95 th percentile amplitude values are calculated across the entire frequency range. This methodology follows a well-established process for noise model creation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Self-Sustainable IoT-Based Remote Sensing Powered by Energy Harvesting Using Stacked Piezoelectric Transducer and Thermoelectric Generator

We propose a self-powered remote multi-sensing system for traffic sensing which is powered by the collective energy harvested from the mechanical vibration of the road caused by the passing vehicles and from the temperature gradient between the asphalt of the road and the soil underneath. A stacked piezoelectric transducer converts mechanical vibrations into electrical energy and a thermoelectric generator harvests the thermal energy from the thermal gradient. Electrical energy signals from the stacked piezoelectric transducer and the thermoelectric generators are converted into usable DC power to recharge the battery using AC-DC and DC-DC converters working simultaneously. The multi-sensing system comprises an embedded system with a microcontroller that acquires data from the sensors and sends the sensory data to an IoT transceiver which transmits the data as RF packets to an ethernet gateway. The gateway converts the RF packets into Internet Protocol (IP) packets and sends them to a remote server. Laboratory and road-testing results showed over 98% sensory data accuracy with the system functioning solely powered by the energy harvested from the alternative energy sources. The successful maximum transmission distance obtained between the IoT, and the gateway was approximately 1 mile, which is a considerable transmission distance achieved in an urban environment. Successful operation of the self-powered multi-sensing system under both laboratory and road conditions contributes considerably to the fields of energy harvesting and self-powered remote sensing systems. The energy flow chart and efficiency for the steps in the system were found to be mechanical power from vehicles to the energy harvester of 0.25%, stacked PZT transducer efficiency was found to be 37%, and for the TEGs the efficiency is 11%. AC-to-DC and DC-to-DC converters’ efficiencies were found to be 90% and 11%. The wireless communication RF transceiver efficiency was found to be 62.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High‐Performance Low‐Emissivity Paints Enabled by N‐Doped Poly(benzodifurandione) (n‐PBDF) for Energy‐Efficient Buildings

Abstract Low‐emissivity (low‐e) paints reduce radiative heat exchange between buildings and the environment, stabilizing indoor climates and lowering air conditioning demand. However, low‐cost, durable, and colored low‐e paints have yet to be demonstrated. Here, an approach is proposed using n‐doped poly(benzodifurandione) (n‐PBDF), a transparent organic conducting polymer, coated over colored commercial paints. This achieves a low thermal emissivity of 0.19 in the mid‐infrared spectrum, attributed to the efficient charge transport of delocalized π‐electrons in n‐PBDF structure. The reduction in thermal emissivity aids in regulating building temperatures by minimizing heat transfer between buildings and their surroundings across diverse climate zones and seasons. The n‐PBDF coating preserves the underlying paint's color due to its high visible transparency, meeting aesthetic requirements. It also shows strong stability in accelerated indoor weathering tests, ensuring long‐term performance. Simulations estimate annual HVAC energy savings of over 10,800 kWh in San Francisco and 5,500 kWh in Chicago for the typical mid‐rise apartments. The paint's versatility, scalability, and durability make it suitable for buildings, vehicles, and greenhouses, aiding urban heat island mitigation.

Liu, Xiaojie [School of Mechanical Engineering and↗

Emerging Per- and Polyfluoroalkyl Substances in Tap Water from the American Healthy Homes Survey II

Humans experience widespread exposure to anthropogenic per- and polyfluoroalkyl substances (PFAS) through various media, which can lead to a wide range of negative health impacts. Tap water is an important source of exposure in communities with any degree of contamination but routine or large-scale PFAS monitoring often depends on targeted analytical methods limited to measuring specific PFAS. We analyzed 680 tap water samples from the American Healthy Homes Survey II for PFAS using non-targeted analysis (NTA) to expand the range of detectable PFAS. Based on detection frequency and relative abundance, about half of the identified PFAS were found only by NTA. We identified (with varying degrees of confidence) 75 distinct PFAS, including 57 exclusively detected by NTA. The identified PFAS are members of seven structural subclasses differentiated by their head groups and degree of fluorination. Clustering analysis categorized the PFAS into four coabundance groups dominated by specific PFAS subclasses. One group uniquely identified by NTA contains zwitterionic PFAS and other PFAS transformation products which are likely associated with aqueous firefighting foam contaminants in a small number of spatially correlated samples. These results help further characterize the scope of exposure to emerging PFAS experienced by the U.S. population via tap water and augment nationwide targeted-PFAS monitoring programs.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Thermal, water, and land cover factors led to contrasting urban and rural vegetation resilience to extreme hot months

Abstract With continuing global warming and urbanization, it is increasingly important to understand the resilience of urban vegetation to extreme high temperatures, but few studies have examined urban vegetation at large scale or both concurrent and delayed responses. In this study, we performed an urban–rural comparison using the Enhanced Vegetation Index and months that exceed the historical 90th percentile in mean temperature (referred to as “hot months”) across 85 major cities in the contiguous United States. We found that hot months initially enhanced vegetation greenness but could cause a decline afterwards, especially for persistent (≥4 months) and intense (≥+2 °C) episodes in summer. The urban responses were more positive than rural in the western United States or in winter, but more negative during spring–autumn in the eastern United States. The east–west difference can be attributed to the higher optimal growth temperatures and lower water stress levels of the western urban vegetation than the rural. The urban responses also had smaller magnitudes than the rural responses, especially in deciduous forest biomes, and least in evergreen forest biomes. Within each biome, analysis at 1 km pixel level showed that impervious fraction and vegetation cover, local urban heat island intensity, and water stress were the key drivers of urban–rural differences. These findings advance our understanding of how prolonged exposure to warm extremes, particularly within urban environments, affects vegetation greenness and vitality. Urban planners and ecosystem managers should prioritize the long and intense events and the key drivers in fostering urban vegetation resilience to heat waves.

54 ENVIRONMENTAL SCIENCES↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Citizen science coupled with machine learning to quantify green-blue infrastructure cooling potential in Maricopa County, Arizona

Here, this study investigates the spatiotemporal cooling performance of green and blue infrastructure (GBI) in the Dobson Ranch urban neighborhood in Phoenix, Arizona. We leveraged citizen science near-surface (2 m) air temperature (Tair) measurements to train a highly accurate Tair predicting LightGBM machine learning model (R 2 : 0.986, MAE: 0.251 °C, RMSE: 0.585 °C). On June 16, 2024, the park area exhibited approximately 1 °C cooling effect (relative to the neighborhood mean) during both day and night. In contrast, the nearby artificial lake exhibited a stronger cooling effect of 2.4 °C during the day but a slight warming of 0.3 °C at night. At 00:00, locations 50 m downwind of the park were 0.3 °C warmer than the park, while locations 50 m upwind were 0.8 °C warmer. At 11:00, we observed that the downwind area is 0.8 °C cooler and the upwind area is 0.6 °C warmer—at the same 50 m distances relative to the park. We also observed 1 °C cooler and warmer effects respectively at the same 50 m downwind and upwind locations at 19:00 on June 17, 2024. Our data-driven analysis highlights potential limitations of car-traverse measurements, showing that failure to account for temporal variations during the traverse can lead to overestimation of Tair at night and underestimation during the day. Our analysis also showed only a weak correlation (coefficient: 0.48) between Landsat-derived land surface temperature (LST) and model predicted Tair at the time of the local Landsat overpass (∼11.00). This highlights the potential error of relying solely on LST for human thermal exposure analysis—particularly within the heterogenous built-environment.

54 ENVIRONMENTAL SCIENCES↗

Energy efficiency and thermal resilience analysis for row houses using representative building energy models

Row houses, a prevalent medium-density urban archetype, were popularized during industrial era to accommodate the working class in the U.S. cities. Today, many of these structures are deteriorating, exacerbating the energy cost for residents with limited economic resources. Moreover, many households that lack Air Conditioning (AC) are vulnerable to extreme summer heat, an issue expected to worsen in the future. Energy-efficient retrofits can help mitigate these challenges. However, current literature provides limited insight into how existing building energy codes impact the energy efficiency and thermal resilience of row houses in current and future weather scenarios. This study provides a detailed method to address this gap by employing calibrated representative energy models of row houses as a baseline, and evaluating the annual energy savings and summertime thermal safety improvements from code compliant retrofits under current and future typical weather conditions. Using Baltimore City as a case study, results show that under current weather, retrofitting row houses yields significant energy savings along with notable thermal resilience improvements. The end unit row house realizes higher energy savings, whereas the interior unit experiences greater thermal resilience improvement after retrofitting. In future, retrofitted row houses can still save energy, but residents will face numerous hours of fatal indoor temperatures without AC in summer. Additionally, findings reveal stark zone-wise variations in thermal safety, and elevated humidity risks in certain zones post-retrofit, emphasizing the need for zonal retrofit strategies and better natural ventilation strategies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗