Vacuum system for the Boiling Liquid-Metal Heat Transfer Facility
Vacuum system for boiling liquid metal heat transfer facility
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Vacuum system for boiling liquid metal heat transfer facility
Bakeout procedures for small glass ultrahigh vacuum systems with small oxygen to carbon monoxide conversion
UV spectrophotometer for continuous measurement in vacuum systems of polyphenyl diffusion pump fluid film thickness
Ozone effect on stability of Dc-704 fluid in diffusion pump vacuum system
Internal surfaces of the glass component of a vacuum system are exposed to cesium in gaseous form to reduce helium permeation. The cesium gas is derived from decomposition of cesium nitrate through heating. Several minutes of exposure of the internal surfaces of the glass vessel are sufficient to complete the treatment.
Sealing caps devised for boltholes on vacuum-system flanges. Used in place of leak-prone gaskets, and provide solid metal-to-metal interfaces. Each sealing cap contains square-cut circular groove in which O-ring placed. Mounted on studs protruding into access ports, providing positive seal around each bolthole. Each cap mates directly with surface of flange, in solid metal-to-metal fit, with O-ring completely captured in groove. Assembly immune to misalignment, leakage caused by vibration, and creeping distortion caused by weight of port. O-ring material chosen for resistance to high temperature; with appropriate choice of material, temperature raised to as much as 315 degrees C.
Mathematical model for cost estimates and optimal control of ultrahigh vacuum system
The theory, algorithms, and test data correlation analysis of a math model developed to predict performance of the Space Station Freedom Vacuum Exhaust System are presented. The theory used to predict the flow characteristics of viscous, transition, and molecular flow is presented in detail. Development of user subroutines which predict the flow characteristics in conjunction with the SINDA'85/FLUINT analysis software are discussed. The resistance-capacitance network approach with application to vacuum system analysis is demonstrated and results from the model are correlated with test data. The model was developed to predict the performance of the Space Station Freedom Vacuum Exhaust System. However, the unique use of the user subroutines developed in this model and written into the SINDA'85/FLUINT thermal analysis model provides a powerful tool that can be used to predict the transient performance of vacuum systems and gas flow in tubes of virtually any geometry. This can be accomplished using a resistance-capacitance (R-C) method very similar to the methods used to perform thermal analyses.
A series of experiments designed to investigate the effect of irradiating a portion of a vacuum system with ultraviolet (UV) light are discussed. Data obtained with the quartz crystal microbalance show that, under ultraviolet irradiation, clean and contaminated mean different things than in situations that do not involve irradiation. The history of the chamber appears to be of paramount importance, not the pumping mechanism. UV irradiation check for contamination is recommended in critical experiments.
Silicone-rubber adhesive is applied externally to seal hair-line cracks in sections of high vacuum system while system is partially evacuated. No pretreatment of surface is required since adhesive will be drawn into crack while diffusion or ion pump is off.
Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.
Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.
Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.
Closed cycle refrigeration loop in which trays holding molecular sorbent are made to serve as cooling baffles improves the performance of high vacuum systems. High performance is obtained with almost no decrease in pumping speed.
The use of silicone rubber adhesive (particularly, G.E. RTV-108) for sealing large leaks in high vacuum systems subject to mechanical and thermal stresses is shown to be more effective than that of epoxy cements. The sealant is applied externally to the leak while the system is partially evacuated so that it is drawn into the hole.
A laser interferometer gravitational wave observatory (LIGO) is being developed with sensitivities which will have a high probability of detecting gravitational waves from astrophysical sources. A major component of LIGO is a total of 16 km of 1.2 m (48 inch) diameter tube at a pressure of less than 10 to the minus 8th power torr. It will be of 304L stainless steel procured directly from the steel mills with the initial hydrogen content specially reduced. Projections of the outgassing rates of hydrogen and of water vapor as a function of time are given and the uncertainties discussed. Based on these, a preliminary analysis of the vacuum system is presented.
A Multiple Internal Seal Ring (MISR) Micro-Electro-Mechanical System (MEMS) vacuum package that hermetically seals MEMS devices using MISR. The method bonds a capping plate having metal seal rings to a base plate having metal seal rings by wafer bonding the capping plate wafer to the base plate wafer. Bulk electrodes may be used to provide conductive paths between the seal rings on the base plate and the capping plate. All seals are made using only metal-to-metal seal rings deposited on the polished surfaces of the base plate and capping plate wafers. However, multiple electrical feed-through metal traces are provided by fabricating via holes through the capping plate for electrical connection from the outside of the package through the via-holes to the inside of the package. Each metal seal ring serves the dual purposes of hermetic sealing and providing the electrical feed-through metal trace.
A Multiple Internal Seal Ring (MISR) Micro-Electro-Mechanical System (MEMS) vacuum packaging method that hermetically seals MEMS devices using MISR. The method bonds a capping plate having metal seal rings to a base plate having metal seal rings by wafer bonding the capping plate wafer to the base plate wafer. Bulk electrodes may be used to provide conductive paths between the seal rings on the base plate and the capping plate. All seals are made using only metal-to-metal seal rings deposited on the polished surfaces of the base plate and capping plate wafers. However, multiple electrical feed-through metal traces are provided by fabricating via holes through the capping plate for electrical connection from the outside of the package through the via-holes to the inside of the package. Each metal seal ring serves the dual purposes of hermetic sealing and providing the electrical feed-through metal trace.