Search NASA⌕ Search

SEARCH · Search NASA

Results for “VEINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

History of Metal Veins in Acapulcoite-Lodranite Clan Meteorite GRA 95209

Graves Nunataks (GRA) 95209 has been hailed as the missing link of core formation processes in the acapulcoitelodranite parent asteroid because of the presence of a complex cm-scale metal vein network. Because the apparent liquid temperature of the metal vein (approximately 1500 C) is higher than inferred for the metamorphic grade of the meteorite, questions regarding the vein s original composition, temperature, and mechanism of emplacement have arisen. We have determined trace siderophile element compositions of metals in veins and surrounding matrix in an effort to clarify matters. We analyzed metals in GRA 95209 in a portion of thick metal vein and adjacent metal-rich (30-40 modal%), sulfide poor (less than 1%) matrix by EPMA and LA-ICP-MS for major and trace siderophile elements using methods described by [3]. We also examined metals from a metal-poor (approximately 15 modal%) and relatively sulfide-rich (2-5 modal%) region of the sample. Kamacite is the dominant metal phase in all portions of the sample. In comparison to matrix metal, vein metal contains more schreibersite and less tetrataenite, and is less commonly associated with Fe,Mn,Mg-bearing phosphates and graphite. Vein kamacite contains higher Co, P, and Cr and lower Cu and Ge. These minor variations aside, all metal types in GRA 95209 are fairly homogeneous in terms of their levels of enrichment of compatible siderophile elements (e.g. Pt, Ir, Os) relative to incompatible siderophile elements (e.g. As, Pd, Au), consistent with the loss of metal-sulfide partial melt that characterizes much of the clan. Whatever compositional differences between matrix and vein metal that may have originally existed, they have since largely co-equilibrated to similar restitic trace element compositions. We agree with [2] that metal veins, in their present state, do not represent a liquid composition. The original vein liquid was much more S-rich and emplaced at correspondingly lower liquid temperatures. Much of the Fe,Ni component solidified in cm scale conduits while S-rich melts were expelled and continued to migrate by percolation. The higher troilite content in metal poor regions of the sample results mostly from trapping of a small portion of these melts. The troilite is not remnant primary sulfide. Strong depletions of W, Mo, and especially Ga (greater than 50%, greater than 60%, and greater than 90% depletion, respectively) in metals of the metalpoor GRA 95209 lithology are localized at scales of 10-100 micrometers in the vicinity of graphite spherules. These depletions must have occurred below the temperatures at which cm-scale equilibration occurred, and future work will seek to determine their cause.

Herrin, J. S.↗

Toward an Optimal Position for IVC Filters: Computational Modeling of the Impact of Renal Vein Inflow

The purpose of this report is to evaluate the hemodynamic effects of renal vein inflow and filter position on unoccluded and partially occluded IVC filters using three-dimensional computational fluid dynamics. Three-dimensional models of the TrapEase and Gunther Celect IVC filters, spherical thrombi, and an IVC with renal veins were constructed. Hemodynamics of steady-state flow was examined for unoccluded and partially occluded TrapEase and Gunther Celect IVC filters in varying proximity to the renal veins. Flow past the unoccluded filters demonstrated minimal disruption. Natural regions of stagnant/recirculating flow in the IVC are observed superior to the bilateral renal vein inflows, and high flow velocities and elevated shear stresses are observed in the vicinity of renal inflow. Spherical thrombi induce stagnant and/or recirculating flow downstream of the thrombus. Placement of the TrapEase filter in the suprarenal vein position resulted in a large area of low shear stress/stagnant flow within the filter just downstream of thrombus trapped in the upstream trapping position. Filter position with respect to renal vein inflow influences the hemodynamics of filter trapping. Placement of the TrapEase filter in a suprarenal location may be thrombogenic with redundant areas of stagnant/recirculating flow and low shear stress along the caval wall due to the upstream trapping position and the naturally occurring region of stagnant flow from the renal veins. Infrarenal vein placement of IVC filters in a near juxtarenal position with the downstream cone near the renal vein inflow likely confers increased levels of mechanical lysis of trapped thrombi due to increased shear stress from renal vein inflow.

59 BASIC BIOLOGICAL SCIENCES↗

Wide-blocky veins explained by dependency of crystal growth rate on fracture surface type: Insights from phase-field modeling

Vein microstructures contain a wealth of information on coupled chemical and mechanical processes of fracturing, fluid transport, and crystal growth. Numerical simulations have been used for exploring the factors controlling the development of vein microstructures; however, they have not been quantitatively validated against natural veins. Here we combined phase-field modeling with microtextural analysis of previously unexplained wide-blocky calcite veins in natural limestone and of the fresh fracture surface in this limestone. Results show that the wide-blocky vein textures can only be reproduced if ~10%–20% of crystals grow faster than the rest. This fraction corresponds to the amount of transgranularly broken grains that were observed on the experimental fracture surfaces, which are dominantly intergranular. We hypothesize that transgranular fractures allow faster growth of vein minerals due to the lack of clay coatings and other nucleation discontinuities that are common along intergranular cracks. Our simulation results show remarkable similarity to the natural veins and reproduce the nonlinear relationship between vein crystal width and vein aperture. This allows accurate simulations of crystal growth processes and related permeability evolution in fractured rocks.

Geology↗

Percutaneous Transsplenic Access to the Portal Vein for Management of Vascular Complication in Patients with Chronic Liver Disease

Purpose: To evaluate the safety and feasibility of percutaneous transsplenic access to the portal vein for management of vascular complication in patients with chronic liver diseases. Methods: Between Sept 2009 and April 2011, percutaneous transsplenic access to the portal vein was attempted in nine patients with chronic liver disease. Splenic vein puncture was performed under ultrasonographic guidance with a Chiba needle, followed by introduction of a 4 to 9F sheath. Four patients with hematemesis or hematochezia underwent variceal embolization. Another two patients underwent portosystemic shunt embolization in order to improve portal venous blood flow. Portal vein recanalization was attempted in three patients with a transplanted liver. The percutaneous transsplenic access site was closed using coils and glue. Results: Percutaneous transsplenic splenic vein catheterization was performed successfully in all patients. Gastric or jejunal varix embolization with glue and lipiodol mixture was performed successfully in four patients. In two patients with a massive portosystemic shunt, embolization of the shunting vessel with a vascular plug, microcoils, glue, and lipiodol mixture was achieved successfully. Portal vein recanalization was attempted in three patients with a transplanted liver; however, only one patient was treated successfully. Complete closure of the percutaneous transsplenic tract was achieved using coils and glue without bleeding complication in all patients. Conclusion: Percutaneous transsplenic access to the portal vein can be an alternative route for portography and further endovascular management in patients for whom conventional approaches are difficult or impossible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Percutaneous Radiofrequency Ablation of Portal Vein Tumor Thrombus: Safety and Feasibility

We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation (RFA) using an endovascular bipolar RF device. A 0.035-inch guidewire was introduced into a tributary of the portal vein and through which a 5G guide catheter was introduced into the main portal vein. After manipulation of the guide catheter over the thrombus under digital subtraction angiography, the endovascular RF device was inserted and activated around the thrombus. There were no observed technique specific complications, such as hemorrhage, vessel perforation, or infection. Post-RFA portography showed partial recanalization of portal vein. RFA of portal vein tumor thrombus in patients with hepatocellular carcinoma is technically feasible and warrants further investigation to assess efficacy compared with current recanalization techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Helical I-125 Seed Implant in the Portal Vein

Purpose: To evaluate the feasibility of helical iodine-125 (I-125) seed portal vein implantation. Materials and Methods: Helical I-125 seed implants were placed into the portal vein of healthy pigs through the transjugular (n = 3) or percutaneous transhepatic (n = 3) route. Six pigs received follow-up at 9 weeks after implantation. Blood tests were performed preimplantation, and at 1 and 9 weeks after implantation. Contrast-enhanced computed tomography (CT) and single-photon emission computed tomography combined with CT (SPECT-CT) were acquired after implantation. Post-implantation CT was imported to the treatment planning system (TPS) for dose verification. At 9 weeks after implantation, another CT was performed before histopathological examination. Results: All implantations were successful, and the helical implants were fixed to the portal vein. CT showed no implant migration or portal vein thrombosis. The average dose to 90% of the target volume calculated from TPS was 68.4 Gy. SPECT-CT revealed an irregular isodose around the implant, in which the hottest spot was near the central portal vein lumen. All pigs were in good condition at the 9-week follow-up. Histopathology studies confirmed no portal vein thrombosis. Pigs showed no signs of bleeding, necrosis, or perforation of the peripheral tissue or organs. Intimal hyperplasia was observed at the two ends of the implant. A mild inflammatory response was detected in the bile duct and adjacent liver tissues, yet there was no apparent inflammation of the hepatic arteries. Conclusion: The helical I-125 seed implants can be inserted into the portal veins of healthy pigs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-65: Motion Difference Between the Pancreas and Nearby Veins for Pancreas Motion Monitoring Using Ultrasound During Radiation Therapy

Purpose: As it is generally difficult to outline the pancreas on an ultrasound b-mode image, visualized structures such as the portal or the splenic veins are assumed to have the same motion as the pancreas. These structures can be used as a surrogate for monitoring pancreas motion during radiation therapy (RT) delivery using ultrasound. To verify this assumption, we studied the motion difference between the head of the pancreas, the portal vein, the tail of the pancreas, and splenic vein. Methods: 4DCT data acquired during RT simulation were analyzed for a total of 5 randomly selected patients with pancreatic cancer. The data was sorted into 10 respiratory phases from 0% to 90% (0%: end of the inspiration, 50%: end of expiration) . The head of the pancreas (HP), tail of the pancreas (TP), portal vein (PV), and splenic vein (SV) were contoured on all 10 phases. The volume change and motion were measured in the left-right (LR), anterior-superior (AP), and superior-inferior (SI) directions. Results: The volume change for all patients/phases were: 1.2 ± 3% for HP, 0.78 ± 1.6% for PV, 2.5 ± 2.9% for TP, and 0.53 ± 2.1% for SV. Motion for each structure was estimated from the centroid displacements due to the uniformity of the structures and the small volume change. The measured motion between HP and PV was: LR: 0.1 ± 0.17 mm, AP: 0.04 ± 0.1 mm, SI: 0.17 ± 0.16 mm and between TP and the PV was: LR: 0.05 ± 0.3 mm, AP: 0.1 ± 0.4 mm, SI: 0.01 ± 0.022 mm. Conclusion: There are small motion differences between the portal vein and the head of the pancreas, and the splenic vein and the tail of the pancreas. This suggests the feasibility of utilizing these features for monitoring the pancreas motion during radiation therapy.

60 APPLIED LIFE SCIENCES↗

Boron and Lithium in Calcium Sulfate Veins: Tracking Precipitation of Diagenetic Materials in Vera Rubin Ridge, Gale Crater

The NASA Curiosity rover's ChemCam instrument suite has detected boron in calcium-sulfate-filled fractures throughout the sedimentary strata of Gale crater including Vera Rubin ridge. The presence of elevated B concentration provides insights into Martian subsurface aqueous processes. Here, we extend the data set of B in Ca-sulfate veins across Gale crater, comparing the detection frequency and relative abundances with Li. We report 33 new detections of B within veins analyzed between Sols 1548 and 2311 where detections increase in Pettegrove Point and Jura members, which form Vera Rubin ridge. The presence of B and Li in the Ca-sulfate veins is possibly due to dissolution of preexisting B in clays of the bedrock by acids or neutral water and redistribution of the elements into the veins. Elevated frequency of B detection in veins of Gale crater correlates with presence of dehydration features such as desiccation cracks, altered clay minerals and detections of evaporites such as Mg-sulfates and chloride salts in the host rocks. The increased observations of B also coincide with decreased Li concentration in the veins (average Li concentration of veins drops by ~15 ppm). Boron and Li have varying solubilities, and Li does not form salts as readily upon dehydration as B, causing it to remain in the solution. So the weak negative correlation between B and Li may reflect the crystallization sequence during dehydration on Vera Rubin ridge.

58 GEOSCIENCES↗

Genetics of varicose veins reveals polygenic architecture and genetic overlap with arterial and venous disease

Varicose veins represent a common cause of cardiovascular morbidity, with limited available medical therapies. Although varicose veins are heritable and epidemiologic studies have identified several candidate varicose vein risk factors, the molecular and genetic basis remains uncertain. Here we analyzed the contribution of common genetic variants to varicose veins using data from the Veterans Affairs Million Veteran Program and four other large biobanks. Among 49,765 individuals with varicose veins and 1,334,301 disease-free controls, we identified 139 risk loci. We identified genetic overlap between varicose veins, other vascular diseases and dozens of anthropometric factors. Using Mendelian randomization, we prioritized therapeutic targets via integration of proteomic and transcriptomic data. Finally, topological enrichment analyses confirmed the biologic roles of endothelial shear flow disruption, inflammation, vascular remodeling and angiogenesis. Further, these findings may facilitate future efforts to develop nonsurgical therapies for varicose veins.

59 BASIC BIOLOGICAL SCIENCES↗

Prolonged lobar hypoxia in vivo enhances the responsivity of isolated pulmonary veins to hypoxia

The hypoxic response of pulmonary vessels isolated from eight sheep whose right apical lobes (RAL) had inspired 100% N2 for 20 h was studied. The RAL of these conscious sheep inspired hypoxic gas and the remainder of the lung inspired air. During hypoxia, RAL perfusion was 33 +/- 3% of its air value, carotid arterial PO2 averaged 86 +/- 3 mm Hg and pulmonary perfusion pressure was not significantly different from the initial control period when the RAL inspired air. At the end of the hypoxic exposure, the sheep were killed, and pulmonary artery and vein rings (0.5 to 2 mm inner diameter) were isolated from both the RAL and the right cardiac lobe, which served as the control lobe (CL). Arteries from the RAL and CL did not contract in response to 6% O2/6% CO2/88% N2 (hypoxia). In contrast, RAL veins did contract vigorously in response to hypoxia, whereas CL veins did not contract or contracted only minimally. Rubbing of the endothelium or prior incubation of RAL veins with catalase (1,200 units/ml), indomethacin (10(-5) M), or the thromboxane A2/prostaglandin H2 (TxA2/PGH2) receptor antagonist, SQ 29,548 (3 X 10(-6) M) each significantly reduced the response to hypoxia. RAL veins were also found to be more reactive than CL veins to the prostaglandin endoperoxide analogue U46619. We conclude that prolonged lobar hypoxia in vivo increases the responsivity of isolated pulmonary veins to hypoxia. These contractions may result from an increase in reactive O2 species, which in turn modify production of, metabolism of, and/or tissue responsivity to TxA2/PGH2.

NASA Discipline Cardiopulmonary↗

Trans-Splenic Portal Vein Embolization: A Technique to Avoid Damage to the Future Liver Remnant

Portal vein embolization (PVE) induces hypertrophy of the future liver remnant (FLR) in patients undergoing extensive hepatic resection. Portal vein access for PVE via the ipsilateral hepatic lobe (designated for resection) places veins targeted for embolization at acute angles to the access site requiring reverse curve catheters for access. This approach also involves access close to tumors in the ipsilateral lobe and requires care to avoid traversing tumor. Alternatively, a contralateral approach (through the FLR) risks damage to the FLR due to iatrogenic trauma or non-target embolization. Two patients successfully underwent PVE via trans-splenic portal vein access, allowing easy access to the ipsilateral portal veins and eliminating risk of damage to FLR. Technique and advantages of trans-splenic portal vein access to perform PVE are described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MicroRNA-92a -mediated endothelial to mesenchymal transition controls vein graft neointimal lesion formation

Highlights: • TGF-β triggers microRNA-92a mediated EndMT by targeting ITGA5 is key role in vein graft vascular remodeling. • Silencing of microRNA-92a-mediated endothelial to mesenchymal transition inhibits vein graft neointimal hyperplasia. • Local adeno-associated virus delivery gene therapy deregulation of microRNA-92a-mediated EndMT may represent promising therapeutic approach for vein grafts failure. Long-term failure of vein grafts due to neointimal hyperplasia remains an important problem in coronary artery bypass graft surgery. Endothelial to mesenchymal transition (EndMT) contributes to vein graft vascular remodeling. However, there is little study on microRNA-mediated EndMT contributions to neointimal formation in vein graft. We hypothesized that microRNA-92a (miR-92a) might play an important role in determining EndMT contributions to neointimal formation.

60 APPLIED LIFE SCIENCES↗

Transsinusoidal Portal Vein Embolization with Ethylene Vinyl Alcohol Copolymer (Onyx): A Feasibility Study in Pigs

Purpose: Portal vein embolization is performed to increase the future liver remnant before liver surgery in patients with liver malignancies. This study assesses the feasibility of a transsinusoidal approach for portal vein embolization (PVE) with the ethylene vinyl alcohol copolymer, Onyx. Methods: Indirect portography through contrast injection in the cranial mesenteric artery was performed in eight healthy pigs. Onyx was slowly injected through a microcatheter from a wedged position in the hepatic vein and advanced through the liver lobules into the portal system. The progression of Onyx was followed under fluoroscopy, and the extent of embolization was monitored by indirect portography. The pigs were euthanized immediately (n = 2), at 7 days (n = 4), or at 21 days postprocedure (n = 2). All pigs underwent necropsy and the ex vivo livers were grossly and histopathologically analyzed. Results: Transsinusoidal PVE was successfully performed in five of eight pigs (63%). In 14 of 21 injections (67%), a segmental portal vein could be filled completely. A mean of 1.6 liver lobes per pig was embolized (range 1-2 lobes). There were no periprocedural adverse events. Focal capsular scarring was visible on the surface of two resected livers, yet the capsules remained intact. Histopathological examination showed no signs of recanalization or abscess formation. Mild inflammatory reaction to Onyx was observed in the perivascular parenchyma. Conclusions: The porcine portal vein can be embolized through injection of Onyx from a wedged position in the hepatic vein. Possible complications of transsinusoidal PVE and the effect on contralateral hypertrophy need further study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation of wide-blocky calcite veins by extreme growth competition

Liassic limestones on the coast of Somerset in the UK contain dense arrays of calcite microveins with a common, but poorly understood microstructure, characterized by laterally wide crystals that form bridges across the vein. We investigated the mechanisms of formation and evolution of these ‘wide-blocky’ vein microstructures using a combination of high-resolution analytical methods, including virtual petrography, optical cathodoluminescence and scanning electron microscopy techniques (e.g. energy-dispersive X-ray spectrometry, back-scattered electron imaging, cathodoluminescence and electron back-scattered diffraction), laboratory experiments and multiphase field modelling. Our results indicate that the studied veins formed in open, fluid-filled fractures, each in a single opening and sealing episode. As shown by the optical and electron back-scattered diffraction images, the vein crystals grew epitaxially on grains of the wall rock and we hypothesize that their growth rates differed depending on whether the crystals were on a wall rock grain substrate that fractured intergranularly (slow growth rates) or transgranularly (rapid growth rates). Our multiphase field models support this hypothesis, showing that wide, blocky crystals only form where there are significant differences in the growth rate and are dependent on the type of seed grain. These results provide strong evidence for extreme growth competition, a process that we propose controls vein-filling in many micritic carbonate reservoirs, as well as demonstrate that the characteristics of the fracture wall can affect the filling processes in syntaxial veins. Supplementary material: The description and images of the studied thin sections are available at https://doi.org/10.6084/m9.figshare.c.5172371 . High-resolution optical microscopy mosaics (under plane-polarized- and crossed polarized light) of the thin section collection in PetroScan file format are available on request from the authors.

Geology↗

Three Dimensional Petrography of Kernouve: A Story of Vein Formation, Compaction, and Metamorphism

Metallic veins in ordinary chondrites, like those found in Kernouve (H5, S1), have been attributed to impact or shock processes on the parent body. However, Kernouve is widely known to exhibit few traditional signs of shock loading and has a very old {sup 39}Ar-{sup 40}Ar age (4.46 Ga), making the significance of vein formation in Kernouve unclear. One possibility is early vein formation followed by partial obliteration due to thermal metamorphism. We examine this scenario here. The metal vein in Kernouve can be explained as a pre-metamorphic shock-induced structure, given the evidence for current weak compaction and low shock stage. However, it is not clear how one explains high porosity and low shock stage if the meteorite experienced early shock sufficiently strong to mobilize metal into a vein-like structure. Some combination of unusual conditions during shock (e.g. high temperatures) or mobility of metal during metamorphism may be needed. One possible mechanism occurring early on the H chondrite parent body follows: blocks of slightly indurated but porous material were disturbed by an impact which caused a physical concentration of metallic phases akin to slickensides. Shearing of these materials caused the warm, ductile metal grains to be concentrated on rock surfaces. This process would have imparted the rocks with indicators cited by as shock induced. This event happened early in the history of the chondrite otherwise shearing forces would have imparted a preferred orientation upon the metal grains. Subsequent annealing due to radiogenic heating erased any preferential orientation and further coalesced the vein metal. The final compaction of the material occurred yielding the porosity seen in the samples today. The material escaped other major shock episodes.

79 ASTRONOMY AND ASTROPHYSICS↗

Endovenous Laser Ablation of Incompetent Perforator Veins: A New Technique in Treatment of Chronic Venous Disease

The aim of this study was to assess the feasibility of endovenous laser ablation of incompetent perforator veins in a patient with incompetency of the small saphenous vein and multiple perforator veins. Two different methods were used to ablate seven perforator veins with a laser giving 50-60 J/cm energy. Total occlusion was observed in six perforators, and partial ablation in one perforator, at 1-month follow-up. To our knowledge, endovenous laser ablation of incompetent perforator veins is easy and a good therapeutic method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Retrospective Comparative Study of Tunneled Haemodialysis Catheters Inserted Through Occluded or Collateral Veins Versus Conventional Methods

Tunneled hemodialysis catheters become essential in dialysis access when there is no possibility of using a functioning arteriovenous fistula. Collateral or occluded veins visible on ultrasound are used for puncture and passage of catheters into the central venous system. Chronically occluded veins are crossed with guidewires to allow dilatation and subsequent passage of hemodialysis catheters. We performed a retrospective analysis of patient demographics, comorbidities, procedural complications, functional survival, performance, and history of previous vascular access. The study group was compared with two control groups in which dialysis catheters were inserted either by radiologists in the interventional suite or by clinicians on the wards. Nineteen patients from the study group were compared with same number of patients in both control groups. The mean age of the study group was higher compared with the control groups. There was no significant difference in mean functional survival, infection rates, dialysis pump speeds in the first 2 weeks, and procedural complications between the study group and the controls. The study group had a significantly higher number of previous vascular access interventions, longer dialysis careers, and more comorbidities. Tunneled dialysis catheter placement by way of collateral or occluded veins appears safe and effective. These techniques give the operator further options when faced with patients possessing challenging vascular access. Indeed, there may be a case for preferential use of these veins to keep patent central veins in reserve.

62 RADIOLOGY AND NUCLEAR MEDICINE↗