Search NASA⌕ Search

SEARCH · Search NASA

Results for “VEN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Multiscale approaches for optimizing the impact of strain on Na-ion battery cycle life

Abstract The high costs and geopolitical challenges inherent to the lithium-ion (Li-ion) battery supply chain have driven a rising interest in the development of sodium-ion (Na-ion) batteries as a potential alternative. Unfortunately, the larger ionic radius of Na limits the reversibility of cycling because of the extensive atomic rearrangements that accompany Na-ion insertion, which in turn limit diffusion and charging speed, and lead to rapid degradation of the electrodes. The Center for Strain Optimization for Renewable Energy (STORE) was established to address these challenges and develop new electrode materials for Na-ion cells. This article discusses the current state-of-the-art materials used in Na-ion cells and several directions that STORE believes are critical to understand and control the structural and volumetric changes during the reversible (de)insertion of large cations. Graphical abstract Highlights Understanding the fundamental way materials respond to localized strains at the atomic length-scale is a critical first step in the development of highly reversible, long cycle life, Na-ion insertion hosts. This perspective explores a variety of methods that can be employed to mitigate the detrimental effects of large strain. The insights gained from these investigations should help lay the foundation for the creation of more economical and sustainable batteries that could have immediate impact on global energy infrastructure. Discussion Although there is near universal agreement that electrochemical energy storage must be an integral part of a green-energy future, there is less agreement about how to reduce the cost of energy storage. Replacing high-cost lithium-ion cells with lower-cost sodium-ion batteries is one option frequently considered in future energy models, but the details of what can be achieve with optimized sodium cell performance remains unclear. Here we posit that developing methods to mitigating strain on the electrode particle length scale is a key factor for achieving long-cycle-life sodium-ion batteries. Mitigating strain on the atomic scale suppress electrode-level volume change. Allowing for fast cycling in materials without the problems of electrode cracking or delamination. We further posit that understanding volume change in sodium-ion electrodes at a fundamental level will lead to the designing new sodium-ion electrode materials that will allow for efficient, stable, lower-cost energy storage.

Brady, Michael J.↗

Pathways Toward Electric Mobility: Communities LEAP in Hennepin County, Minnesota

This report presents the findings from a comprehensive community engagement initiative focused on advancing equitable transportation electrification in Hennepin County. This initiative responds to the critical need for inclusive and sustainable mobility solutions in the face of rising environmental and financial challenges in the transportation sector. This project has two goals. First, to learn what each community's priorities are and share them with the city, county, and state government to inform transportation plans and projects. Second, to bridge divides between government and community, building pathways for community-guided decision making on future transportation plans.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗