Search NASA⌕ Search

SEARCH · Search NASA

Results for “VOF method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

27 records · Page 2

Vector-Ordering Filter Procedure for Data Reduction

The vector-ordering filter (VOF) technique involves a procedure for sampling a large population of data vectors to select a subset of data vectors that fully characterize the state space of the large population. The VOF technique enables a large reduction of the volume of data that must be handled in the automated monitoring system and method discussed in the two immediately preceding articles. In so doing, the VOF technique enables the development of data-driven mathematical models of a monitored asset from sets of data that would otherwise exceed the memory capacities of conventional engineering computers. Data-driven mathematical models have been shown to offer high fidelity for purposes of control and monitoring of assets. In practice, a collection of asset-operating observations is acquired with the intention that the collection contain observations characteristic of the full dynamic range of operation of the asset. Often, such a collection contains an extremely large number of observations, many of which are redundant. The VOF technique fills the need for a means to extract, from the original collection of observational data, a reduced data matrix that excludes redundant data while maintaining the full statistical character and dynamic range of the original data. The reduced data matrix can then be used as the input data for development of a mathematical model of the monitored asset, or as training data for a neural-network substitute for an explicit mathematical model of the asset. Alternatively, the reduced data matrix can, itself, be used directly as a mathematical model of the monitored asset, as is commonly done in multivariate state-estimation techniques. The original data are collected from the asset over a range of operating states and are put in matrix form. Each column vector in the original data matrix represents the signal values acquired at a particular operational state of the asset. Thus, the number of columns of the original data matrix equals the number of observed states and the number of rows in this matrix equals the number of signals acquired at each observation. In the VOF technique, one extracts the reduced data matrix from the original data matrix through the selection of a representative subset of the column (state) vectors.

Bickford, Randall L.↗

Experimental and Computational Investigation of Flow Boiling in Microgravity

This study explores use of Computational Fluid Dynamics (CFD) to predict near-saturated flow boiling of FC-72 in microgravity. The computational method employs transient analysis to predict detailed interfacial behavior and heat transfer characteristics along a rectangular channel heated along two opposite walls. Predicted results are validated against experimental temperature measurements and high-speed video images captured during a series of parabolic aircraft maneuvers for three sets of operating conditions which include variations of both mass velocity and wall heat flux. The computational method is based on the multi-phase volume of fluid (VOF) model, which is combined with appropriate phase change and turbulence models, and accounts for both shear-lift force on bubbles and conjugate heat transfer along the heating walls. A key advantage of the CFD method is ability to capture details that are very difficult to measure experimentally, including detailed spatial variations of bubble shape, void fraction, mixture fluid temperature, liquid velocity, and vapor velocity, results for which are presented for each of the three test cases. Different flow regimes predicted along the heated length exhibit a number of dominant mechanisms including bubble nucleation, bubble growth, coalescence, vapor blankets, interfacial waviness, and residual liquid sub-layer, all of which agree well with experiment. Vapor velocity is shown to increase appreciably along the heated length because of increased void fraction, while liquid velocity experiences large fluctuations. Non-equilibrium effects are accentuated with increasing mass velocity, contributing minor deviations of fluid temperature from simulations compared to those predicted by the analytical method. Predicted wall temperature is fairly uniform in the middle of the heated length but increases in the entrance region, due to sensible heat transfer in the subcooled liquid, and decreases toward the exit, mostly because of flow acceleration resulting from increased void fraction.

two-phase cooling; flow boiling; CFD; microgravity↗

Validation of High-Resolution CFD Method for Slosh Damping Extraction of Baffled Tanks

The predicted slosh damping values from Loci-Stream-VOF agree with experimental data very well for all fill levels in the vicinity of the baffle. Grid refinement study is conducted and shows that the current predictions are grid independent. The increase of slosh damping due to the baffle is shown to arise from: a) surface breakup; b) cascade of energy from the low order slosh mode to higher modes; and c) recirculation inside liquid phase around baffle. The damping is a function of slosh amplitude, consistent with previous observation. Miles equation under predicts damping in the upper dome section.

Yang, H. Q.↗

Development of an Atomization Methodology for Spray Combustion

In liquid rocket propulsion, the knowledge and the understanding of liquid-gas interfacial phenomena are very important. This is important for predicting the onset of cavitation occurring in swirl injection elements used in STME, as well as atomization processes in shear-induced injectors (co-axial) and impinging injector elements. From the fact that all the physical processes including droplet size distribution, droplet dispersion, mixing and combustion are controlled by atomization processes, it is expected that the successful incorporation of the volume of fraction (VOF) will greatly enhance the analytical capability of predicting spray combustion processes in liquid-fueled engines. In this paper, a methodology is developed to define and track interfaces between two fluids in non-orthogonal, body-fitted grids using a single fractional volume of fluid (VOF) variable to describe the distribution of the liquid phase in a gas-liquid flow field. This method was implemented in a mature CFD code MAST (Multiphase All-Speed Transient) utilizing the general PISO-C algorithm. For the preliminary study on the analysis of spray combustion and tracking of the interface between two phases, we will report on the progress of the simulation of the instability on the liquid column; the surface wave instability and the droplet breakup from the liquid surface.

Seung, S. P.↗

Validation of Cryogenic Propellant Tank Self-Pressurization by Leveraging Reduced Order Modeling within Computational Fluid Dynamics Simulation

Validation of cryogenic propellant tank self-pressurization was performed using a hybrid Computational Fluid Dynamics (CFD) and reduced order modeling methodology. Data from a liquid hydrogen ground test conducted at the K-site facility at the National Aeronautics and Space Administration (NASA) Glenn Research Center was used for the validation effort. Liquid phase dynamics were explicitly resolved with a CFD tool. Vapor phase dynamics were modeled as a point mass that communicated heat from the tank wall to the liquid phase via a boundary condition used at the gas-liquid interface. The method proved to be more accurate, robust, and efficient than explicit resolution of the dynamics using a standard Volume of Fluid (VOF) methodology. The subject pressurization process was found to be heavily dependent upon both the relatively high liquid temperature gradient near the gas-liquid interface and the natural convection flow path. Modeling the gas-liquid interface as an immovable surface eliminated temperature gradient destroying gas-liquid interface velocities observed in VOF simulations, and correspondingly enabled more rapid simulation since interface advection was not allowed. The single phase computational domain also facilitated the ability to demonstrate spatial resolution convergence of natural convection cells within the liquid which significantly impacted the tank pressurization rate. This work was used to demonstrate the critical physics for tank self-pressurization and numerical methodologies that may be used to best resolve those physics. The findings informed development and operation of production level CFD tools used in the Fluid Dynamics Branch at NASA Marshall Space Flight Center.

J. M. Brodnick↗

Validation of High-Resolution CFD Method for Slosh Damping Extraction of Baffled Tanks

Determination of slosh damping is a very challenging task as there is no analytical solution. The damping physics involve the vorticity dissipation which requires the full solution of the nonlinear Navier-Stokes equations. As a result, previous investigations and knowledge were mainly carried out by extensive experimental studies. A Volume-Of-Fluid (VOF) based CFD program developed at NASA MSFC was applied to extract slosh damping in a baffled tank from the first principle. First, experimental data using water with subscale smooth wall tank were used as the baseline validation. CFD simulation was demonstrated to be capable of accurately predicting natural frequency and very low damping value from the smooth wall tank at different fill levels. The damping due to a ring baffle at different liquid fill levels from barrel section and into the upper dome was then investigated to understand the slosh damping physics due to the presence of a ring baffle. Based on this study, the Root-Mean-Square error of our CFD simulation in estimating slosh damping was less than 4.8%, and the maximum error was less than 8.5%. Scalability of subscale baffled tank test using water was investigated using the validated CFD tool, and it was found that unlike the smooth wall case, slosh damping with baffle is almost independent of the working fluid and it is reasonable to apply water test data to the full scale LOX tank when the damping from baffle is dominant. On the other hand, for the smooth wall, the damping value must be scaled according to the Reynolds number. Comparison of experimental data, CFD, with the classical and modified Miles equations for upper dome was made, and the limitations of these semi-empirical equations were identified.

Yang, H. Q.↗

Validation of High-Resolution CFD Method for Slosh Damping Extraction of Baffled Cryogenic Propellant Tanks

Propellant slosh is a potential source of disturbance critical to the stability of space vehicles. The slosh dynamics are typically represented by a mechanical model of a spring-mass-damper. This mechanical model is then included in the equation of motion of the entire vehicle for Guidance, Navigation and Control analysis. A Volume-Of-Fluid (VOF) based Computational Fluid Dynamics (CFD) program developed at MSFC was applied to extract slosh damping in the baffled tank from the first principle. First the experimental data using water with sub-scale smooth wall tank were used as the baseline validation. It is demonstrated that CFD can indeed accurately predict low damping values from the smooth wall at different fill levels. The damping due to a ring baffles at different depths from the free surface was then simulated, and fairly good agreement with experimental measurement was observed. Comparison with an empirical correlation of Miles equation is also made.

Yang, H. Q.↗

Loci/STREAM Sharp Interface Model Validation of Cryogenic Propellant Tank Self-Pressurization

This paper documents a model validation effort for the prediction of cryogenic propellant tank selfpressurization physics using the Loci/STREAM sharp interface CFD model developed at NASA MSFC. Cryogenic fluid management (CFM) applications for long duration spaceflight missions require accurate modeling of heat transfer and thermodynamics. Therefore, detailed validation of those physics is important to ensure simulation accuracy. In the past, the MSFC Propulsion Fluid Dynamics Branch has validated and used the Loci/STREAM Volume of Fluid (VOF) module extensively for propellant slosh applications, which are dominated by fluid motion. For cases where the interface gas/liquid interface is essentially static, the Loci/STREAM sharp interface was developed for more rapid and efficient CFM analysis. In the present study, Loci/STREAM sharp interface simulations were compared with the NASA K-site self-pressurization experiment of a flight weight, partially full, LH2 tank in normal gravity. This study investigated several parametric effects and made a number of important observations on the performance of the Loci/STREAM sharp interface method: - First, a homogeneous model was derived to verify the CFD model. The homogeneous model assumes both gas and liquid phases are uniform and are at saturation temperature. The predicted pressure rise rates at 3.5 W/m2 and 2.0 W/m2 with a 49% fill level are all lower than the experimental measurement. This is expected due to the observed temperature stratification near the gas-liquid interface during testing. - The k-w and k-e turbulence models predict comparable pressurization rates, which are much lower than the experiment measurement. On the other hand, the pressure values and pressurization rates from both models are almost the same as those of the homogeneous model. The current turbulence model is too diffusive and is not capable of capturing the thermal stratification in the liquid and ullage. - When using the laminar flow model, the pressurization rate is found to be very close to the experimental value when a quasi-steady flow field is allowed to develop by continuously venting the tank prior to pressurization as was done during testing. On the other hand, without initial venting, the rate is not constant. Additionally, the development time to reach a quasi-steady flow field differed from the experiment due to the lack of turbulent mixing away from the gas-liquid interface that is expected in reality. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 15% of the experimental value for 49% fill level at 3.5 W/m 2 and is within 18% for 2.0 W/m 2 heat loading. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 18% of the experimental value for a 29% fill level and within 15% for an 83% fill level.

H. Q. Yang↗

Investigation of Damping Physics and CFD Tool Validation for Simulation of Baffled Tanks at Variable Slosh Amplitude

To meet the flight control damping requirement, baffles of various configurations have been devised to increase the natural viscous damping and decrease the magnitude of the slosh forces and torques. In the design of slosh baffles, the most widely used damping equation is the one derived by Miles, which is based on the experiments of Keulegan and Carpenter. This equation has been used in predicting damping of the baffled tanks in different diameters ranging from 12 to 112 inches. The analytical expression of Miles equation is easy to use, especially in the design of complex baffle system. Previous investigations revealed that some experiments had shown good agreements with the prediction method of Miles, whereas other experiments have shown significant deviations. For example, damping from Miles equation differs from experimental measurements by as much as 100 percent over a range of tank diameters from 12 to 112 inches, oscillation amplitudes from 0.1 to 1.5 baffle widths, and baffle depths of 0.3 to 0.5 tank radius. Previously, much of this difference has been attributed to experimental scatter. A systematical study is needed to understand the damping physics of baffled tanks, to identify the difference between Miles equation and experimental measurement, and to develop new semi-empirical relations to better represent the real damping physics. The approach of this study is to use CFD technology to shed light on the damping mechanisms of a baffled tank. First, a 1-D Navier-Stokes equation representing different length scales and time scales in the baffle damping physics is developed and analyzed. A well validated CFD solver, developed at NASA MSFC, Loci-STREAM-VOF, is applied to study vorticity field around the baffle and around the fluid interface to highlight the dissipation mechanisms at different slosh amplitudes. Previous measurement data are then used to validate the CFD damping results. The study found several critical parameters controlling fluid damping from a baffle: local slosh amplitude to baffle thickness (A/t), surface liquid depth to tank radius (h/R), local slosh amplitude to baffle width (A/W); and non-dimensional slosh frequency. The simulation highlights three significant damping regimes where different mechanisms dominate. The study proves that the previously found discrepancies between Miles equation and experimental measurement are not due to the measurement scatter, but rather due to different damping mechanisms at various slosh amplitudes. The limitations on the use of Miles equation are discussed based on the flow regime.

Yang, H. Q.↗