Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validation Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SCM overview & the EBR-II shutdown heat removal tests validation.

Pronghorn is an engineering-scale, coarse-mesh, thermal-hydraulics tool for supporting reactor-core simulations of advanced nuclear reactors. Most of the current efforts in Pronghorn have been devoted in developing porous finite-volume capabilities and adapting closure correlations for coarse-mesh thermal-hydraulics modeling. However, for liquid-metal reactors (LMRs) with wire-wrapped fuel pin assemblies, a pin-level thermal-hydraulic resolution is required for most safety case studies (pin rupture, channel blockage, etc.). For this purpose, a new Subchannel application is developed in MOOSE, which affords the required flow field resolution, while still preserving an engineering-scale approach. This new solver can be natively coupled to Pronghorn and other MOOSE objects to enable full-core, multi-physics, multi-scale engineering studies. This presentation presents the main features of the SCM code and demonstrates a validation case based on the EBR-II SHRT tests.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Validation testing of 239 Pu IAEA INDEN, LANL and LLNL 239 Pu files from May 2022 [Slides]

239 Pu files validated: ENDF/B-VIII.0, ENDF/B-VIII.0 except for 239 Pu from INDEN (p49) which performs the same in crit testing as (p53), ENDF/B-VIII.0 except for 239 Pu from INDEN (p51), ENDF/B-VIII.0 except for 239 Pu from LANL (4/21), ENDF/B-VIII.0 except for 239 Pu from LLNL (5/16); tweaked nu-bar, ENDF/B-VIII.0 except for 239 Pu from LLNL (5/1)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation, Challenge Testing & Validation of Occupancy Recognition & CO 2 Technologies (Final Project Report)

This final report covers the results of the development of testing methods of occupancy sensor systems connected to HVAC controls. This project focused on the development of test methods to evaluate the performance of HVAC-connected occupancy sensor systems, including occupancy presence, occupancy counting, and CO 2 sensor systems in commercial and residential buildings. This included evaluation of the reliability, ease of commissioning, and energy savings potential of these sensor systems. The results of this work help to standardize the methods used to evaluate performance, to enable the ability to compare sensor system performance following the same methods, to understand which sensor systems perform better or worse compared to others. The U.S. building stock’s energy usage can benefit substantially from having building system operations informed by reliable occupancy recognition and CO 2 measurements, however to date, standard methods have not been in place to ensure that sensor systems’ reported performance is uniformly evaluated. The results of this work support the development of a standard or guideline that outlines the developed methods of testing. This project also included the testing of both off-the-shelf and novel SENSOR team-developed low-cost occupancy sensor systems, using the developed methods of testing. The results of this testing helped to inform further development and improvement of new low-cost sensor systems that will benefit from being used in residential and commercial buildings throughout the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TEAMER - AquaHarmonics High Fidelity WEC Sim PTO and Control Model Validation, Test Logs and Results

Collaborative effort between AquaHarmonics, Sandia National Laboratories (SNL), and the National Renewable Energy Laboratory (NREL) to revise and validate Aquaharmonics' full wave to wire model, allowing for reduced uncertainty and increased understanding of design requirements of a utility scale wave energy converter (WEC). SNL and NREL in collaboration with AquaHarmonics, will set up and run WEC Simulator (WEC-Sim) models of the AquaHarmonics WEC, building off past model developments for inclusion of custom PTO (power take-off) dynamics. The intent is to review, update, and verify or validate a new WEC-Sim model against wave tank experimental data. Furthermore, the WEC-Sim model will be coupled to an energy storage system model to better understand the wave-to-wire functionality. This data set is described in the "Test Log" excel file. Please refer to that document for details on each specific test date/time, constraint parameters and model hardware setup details. Sim model can be found in the associated MHKDR link below.

16 TIDAL AND WAVE POWER↗

Verification and validation testing and tools: comparison between MCNP code versions and nuclear data libraries [Slides]

This presentation discusses the primary goal of software testing which is to test the code for correctness. It also discusses the results for individual suites and the role of validation and verification also referred to in the presentation as V&V. In summation, the V&V framework enables easy comparison between calculations performed with different code versions and/or nuclear data libraries. This entire framework will be distributed with the upcoming MCNP6.3 release. V&V test suites shown and several that were not (Criticality, LAQGSM, Lockwood) will be distributed in the new framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Temperature Test Facility At Scale Testing, Validation, and Demonstration

Theses slides will be used to brief the Tribal DOE and Council Chairman for the project listed below. The High Temperature Test Facility (HTTF) is a demonstration-scale high temperature electrolysis (HTE) system that provides the ability to produce, process, store, and dispense electrolytically produced hydrogen. The system will be designed to accommodate electrolysis systems from various industry partners. The HTTF will be supplied up to 10 MW of power for electrolysis at 5 separate test article locations, each up to 2MW. The system will include post-processing and compression, storage, and capabilities to provide hydrogen for consumption by future end users. The HTTF will also provide the ability to test and demonstrate an HTE system in a configuration that would simulate the use of a nuclear generated steam supply for the high temperature heat source. The HTTF will be located at the Central Facilities Area (CFA) adjacent to CFA-686 on the INL site, 45 miles west of Idaho Falls.

08 HYDROGEN↗

Assessing the accuracy of time-fraction and ductility exhaustion approaches for creep-fatigue damage prediction through feature-test validation

Determining creep-fatigue damage formation is critical for elevated temperature components integrity. This study evaluates creep-fatigue assessments with emphasis on differences between creep damage models. Evaluated are the time-fraction model and the classical and stress-modified ductility exhaustion creep damage models. This work extends the domain of stress-modified ductility exhaustion models by introducing and validating such formalism to Ni-based alloys. The fidelity of the assessments was benchmarked against uniaxial creep-fatigue and multiaxial feature tests of Alloy 617. For uniaxial specimens, best estimate predictions rank ductility exhaustion as the most accurate and precise and time-fraction as markedly conservative. For feature tests, ductility exhaustion predictions are within < 4.0 times difference, whereas time-fraction underpredicts life by factors of 7–14. The observations suggest ductility exhaustion models as alternative to time-fraction models in design codes for situations requiring characterization of the design margin. Further work in employing such models to assess other relevant phenomena (e.g., stress relaxation cracking) is discussed.

creep-fatigue↗

Performance analysis and tank test validation of a hybrid ocean wave-current energy converter with a single power takeoff

This paper introduces a hybrid ocean wave-current energy converter (HWCEC) that harvests energy from ocean waves and current simultaneously with a single power takeoff (PTO). Specifically, the wave energy is extracted through relative heaving motion between a floating buoy and a submerged second body, while the current energy is extracted using a marine current turbine (MCT). Energy from both sources are integrated by a hybrid PTO whose concept is based on a mechanical motion rectifier (MMR). The hybrid PTO with two one-way clutches converts bidirectional, up-and-down motion from the waves into unidirectional rotation of the generator. Meanwhile a third one-way clutch couples the MCT with the same generator. The wave and current can simultaneously or separately drive the same generator through different engagement and disengagement statuses of the one-way clutches. Time-domain simulation is conducted with hydrodynamic coefficients obtained from computational fluid dynamics analysis and boundary element method. Tank tests were conducted for a HWCEC under co-existing wave and current inputs. For comparison, separate baseline tests of a turbine and a two-body point absorber, each acting in isolation, are conducted. Experimental results validate the dynamic modeling and show that a HWCEC can increase the output power with a range between 29-87% over either current turbine and wave energy converter acting individually, and it can reduce by up to 70% the peak-to-average power ratio compared with the wave energy converter on the tested conditions.

16 TIDAL AND WAVE POWER↗

PMT-004 Validation Testing for Thermal Scattering Laws and Some Interesting Temperature-Dependent Implications [Slides]

This presentation finds that PMT-004 has four new benchmark cases highly sensitive to PE TSL (2 cases) and PMMA TSL (2 Cases). Additionally discovered was that the PE cases were well predicted using MCNP6.2 and ENDF/B-VIII.0. PMMA cases overpredicted by approximately 0.6-0.7% in k eff likely due to the lack of integral benchmarks sensitive to PMMA. The NCSU ENDF/B-VIII.1 PMMA TSL is an improvement over VIII.0. This was Accepted at last ICSBEP meeting pending comment resolution, should be published in 2024 version of the Handbook. It was found that temperature had a large impact on reactivity of the critical configuration. This has Implications for validation work for thermal cases- need to adjust TSL data to correct temperature as it can have hundreds of pcm effects for a few °C. Future thermal experiments should try and measure reactivity at multiple temperatures to add in data testing and benchmark adjustment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Verification and Validation Testing and Tools [Slides]

All MCNP team supported V&V test suites are now developed in a separate repository from the MCNP source code within a Python-based framework. This entire framework will be distributed with the upcoming MCNP6.3 release. Most V&V test suites distributed with MCNP6.2 will be distributed in new framework. New V&V test suites are done or being worked on for the MCNP6.3 release.

97 MATHEMATICS AND COMPUTING↗

Electrical Validation Testing for ORPC MHK Generator, Modification 6: ORPC SBV for MHK Generator System (CRADA Final Report)

For the U.S. Department of Energy’s (DOE) 2016 Small Business Voucher for Marine and Hydrokinetic (MHK) System, Second Round 2016, ORPC intends to work with the National Renewable Energy Laboratory (NREL) to perform dynamometer testing of the MHK generator systems and its associated controls and inverters. ORPC will provide the generator, variable frequency drives (VFD), controls, and inverter for this testing. NREL will utilize the NREL Energy Systems Integration Facility (ESIF) and dynamometer facilities at the National Wind Technology Center (NWTC) for this work. Modification 6: Additionally, NREL will conduct a feasibility study for implementing passive DC rectification at the turbine.

17 WIND ENERGY↗