Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vertically Pointing High-Resolution Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Ice Cryo-Encapsulation Balloon (Project ICEBall) Field Campaign Report

The Ice Cryo-Encapsulation Balloon (ICEBall) field campaign was designed to sample the ice crystals that compose high-altitude cirrus with a passive device. The campaign made use of a new instrument, ICEBall, which is a balloon-borne ice crystal sampling system. The ice crystal sounding system is capable of measuring ice crystal concentration, temperature, atmospheric pressure, ice crystal habit, aerosol particle morphology, and residual composition. The 3-kg instrument is carried upwards at 5 m s-1 by a high-altitude balloon. The instrument can be cut down from the balloon at any altitude up to 20 km, and the apparatus returns to the surface by parachute. Basic measurements such as temperature and pressure are recorded onboard, and high-frequency Global Positioning System (GPS) records altitude and latitude/longitude. Ice crystal concentrations are measured through the use of a high-resolution video camera mounted on the device. Ice crystals are collected through an open aperture leading to insulated collection chambers cooled with dry ice. Upon exiting the top of the cloud system, the chamber aperture is closed, and the ~1 mm3 sample cell is magnetically sealed and isolated at -78 °C, ensuring that ice particles do not sublimate or grow after collection. Once the crystals are returned to the surface, they are double-sealed and immersed at liquid nitrogen temperature in “dry-cryo shippers” before being transported back to the laboratory. Dr. Magee’s laboratory at The College of New Jersey contains a cryo-stage scanning electron microscope (SEM), which was used to interrogate the crystals and aerosol particles. The main purpose of this pilot field campaign was to provide an unprecedented level of detail on the crystal habits and ice surface complexity in mid-latitude cirrus, which may help resolve issues associated with habit identification and classification in cirrus. The ICEBall campaign was originally scheduled to run from March 28 to April 18 of 2021 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains observatory. The COVID-19 pandemic intervened and caused us to shift the dates of the experiment to October 16-November 6 of 2021. This period is also climatologically favorable for cirrus. The approximately six-month gap between our original field campaign dates and the actual dates afforded us the opportunity to build two new ICEBall payload instruments. These instruments were tested during an August 2021 trip to The College of New Jersey. During this field testing phase, we decided to launch the ICEBall payload upstream from the ARM SGP site with the goal of landing in the vicinity of the site. Our goal was to sample the ice crystals before the cirrus were advected over the remote-sensing instruments at the SGP site. The team assembled for the field campaign consisted of the Principle Investigator (PI) and Co-Principle Investigator (Co-PI) (Drs. Harrington and Magee), The Pennsylvania State University research scientist Dr. Alfred Moyle, and two graduate students (Ms. Marley Majetic and Gwenore Pokrifka). The team operated out of a house rented in Enid, Oklahoma. We successfully sampled seven cirrus cloud systems during the three-week field campaign (October 21, 23-26, 31, and November 1). This was a much higher success rate than either of the PIs anticipated (our goal was closer to sampling three or four cases). The balloon was typically launched from oil pads or farm fields northwest of Enid and the payload was typically retrieved somewhat north of the SGP site. We never landed directly at the SGP site, and so did not need regular access to the SGP facilities. Our greatest concern going into the field campaign was the longer-term storage of crystals in the -196°C cryo dry-shipper dewars and the subsequent transport across the country. We had tested storage and transport prior to the field campaign, but we had never stored crystals for a few weeks nor had we transported the dewars over long distances. To our great relief, the storage and transport worked flawlessly and we were able to image a large number of crystals from six of the seven cases. Working with the staff at the ARM SGP office was excellent. They not only helped us find the sources we needed for helium, liquid nitrogen, and other materials, but also helped with contacts within the Federal Aviation Administration (FAA) and Vance Air Force Base. One goal of our field project was to tie the in situ measurements of ice crystal habits to the radar signatures derived from the Ka-band ARM Zenith-pointing Radar (KAZR). Unfortunately KAZR was down for the duration of our experiment. However, the Ka-band Scanning ARM Cloud Radar (KASACR) was put into vertically pointing mode during the ICEBall campaign and those data, along with Doppler lidar measurements, have proved very useful.

54 ENVIRONMENTAL SCIENCES↗

The energy landscape of glassy dynamics on the amorphous hafnium diboride surface

Direct visualization of the dynamics of structural glasses and amorphous solids on the sub-nanometer scale provides rich information unavailable from bulk or conventional single molecule techniques. We study the surface of hafnium diboride, a conductive ultrahigh temperature ceramic material that can be grown in amorphous films. Our scanning tunneling movies have a second-to-hour dynamic range and single-point current measurements extend that to the millisecond-to-minute time scale. On the a-HfB{sub 2} glass surface, two-state hopping of 1–2 nm diameter cooperatively rearranging regions or “clusters” occurs from sub-milliseconds to hours. We characterize individual clusters in detail through high-resolution (<0.5 nm) imaging, scanning tunneling spectroscopy and voltage modulation, ruling out individual atoms, diffusing adsorbates, or pinned charges as the origin of the observed two-state hopping. Smaller clusters are more likely to hop, larger ones are more likely to be immobile. HfB{sub 2} has a very high bulk glass transition temperature T{sub g}, and we observe no three-state hopping or sequential two-state hopping previously seen on lower T{sub g} glass surfaces. The electronic density of states of clusters does not change when they hop up or down, allowing us to calibrate an accurate relative z-axis scale. By directly measuring and histogramming single cluster vertical displacements, we can reconstruct the local free energy landscape of individual clusters, complete with activation barrier height, a reaction coordinate in nanometers, and the shape of the free energy landscape basins between which hopping occurs. The experimental images are consistent with the compact shape of α-relaxors predicted by random first order transition theory, whereas the rapid hopping rate, even taking less confined motion at the surface into account, is consistent with β-relaxations. We make a proposal of how “mixed” features can show up in surface dynamics of glasses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Advancements in Tomographic Gamma Scanning for Non- Destructive Assay - 17321

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3- dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has the capability to measure containers of various sizes. Canberra has incorporated numerous enhancements and improvements to the latest system in both its hardware and software components. The signal processing chain and data analysis software have been configured to use either an electronic pulser or digital signal processing (DSP) electronics for dead time corrections. In the case of using the DSP electronics, the need to calibrate and maintain a pulser can be eliminated without sacrificing any performance. For the 120 liter container, the TGS system has been calibrated and validated with three different spatial resolutions, using two collimator aperture sizes, measuring 2.54 and 1.27 cm in width. The system has also been supplied and calibrated with a wide, rectangular collimator (25.4 cm W x 10.2 cm H) for scanning containers solely in the vertical axis. The TGS system also has an automated attenuator assembly, which has the capability to use a combination of attenuators to reduce the count rate for high activity samples. An extensive measurement campaign was performed in addition to the calibration verification to evaluate the accuracy of the system using rod sources, point sources, and a variety of matrices and source distributions. Improvements to the evaluation of the total measurement uncertainty based upon these studies have been incorporated into the analysis software package. Finally, the performance of this new TGS system will be demonstrated in the context of Canberra's previous TGS systems, including several 208 liter-based systems and a smaller, 20 liter container TGS system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Impacts of Source Location in Tomographic Gamma Scanning - 17324

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has been equipped to use various collimators and attenuators to assay containers under a wide range of operational conditions. In this paper, we report on experimental work using TGS systems aimed at evaluating the effects of source locations at the limits of volume elements, or voxels, defined in the image reconstruction. These include sources placed at voxel boundaries within a single vertical layer and sources placed in the lowest and highest possible vertical positions within the containers. Building upon previous studies, the accuracy of the TGS system was also assessed by varying the radial position of a point source within a vertical segment. The robustness of the TGS image reconstruction algorithm to location of the sources location was also analyzed as a function of matrix density and gamma-ray energy. Methods to reduce the biases from source location at extreme positions within the container were implemented and tested. The results from this work have been used to better understand the total measurement uncertainty (TMU) and analysis methodology used in TGS systems currently deployed and under development. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗