Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tri-molybdenum phosphide (Mo 3 P) and multi-walled carbon nanotube junctions for volatile organic compounds (VOCs) detection

Detection and analysis of volatile organic compounds' (VOCs) biomarkers lead to improvement in healthcare diagnosis and other applications such as chemical threat detection and food quality control. Here, we report on tri-molybdenum phosphide (Mo3P) and multiwalled carbon nanotube (MWCNT) junction-based vapor quantum resistive sensors (vQRSs), which exhibit more than one order of magnitude higher sensitivity and superior selectivity for biomarkers in comparison to pristine MWCNT junctions based vQRSs. Transmission electron microscope/scanning tunneling electron microscope with energy dispersive x-ray spectroscopy, x-ray diffraction, and x-ray photoelectron spectroscopy studies reveal the crystallinity and the presence of Mo and P elements in the network. The presence of Mo3P clearly enhanced the performance of vQRS as evidenced in sensitivity and selectivity studies. The vQRSs are stable over extended periods of time and are reproducible, making them a potential candidate for sensing related applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of wood plastic composites made from landfill-derived plastic and sawdust: Volatile compounds and olfactometric analysis

Graphical abstract: This work details the characterization of VOCs of WPC, produced from residual materials which would have landfills as current destination, and evaluates their odor profile. Highlights: ► More than 140 volatile compounds were identified in raw materials and WPC products. ► Markers were related to the thermal degradation, sawdust or coupling agents. ► WPC prototype showed a characteristic odor profile of burnt, sweet and wax-like. ► Aldehydes, carboxylic acids, ketones and phenols were odor descriptors of WPC. - Abstract: Application of wood plastic composites (WPCs) obtained from recycled materials initially intended for landfill is usually limited by their composition, mainly focused on release of volatile organic compounds (VOCs) which could affect quality or human safety. The study of the VOCs released by a material is a requirement for new composite materials. Characterization and quantification of VOCs of several WPC produced with low density polyethylene (LDPE) and polyethylene/ethylene vinyl acetate (PE/EVA) films and sawdust were carried out, in each stage of production, by solid phase microextraction in headspace mode (HS-SPME) and gas chromatography–mass spectrometry (GC–MS). An odor profile was also obtained by HS-SPME and GC–MS coupled with olfactometry analysis. More than 140 compounds were observed in the raw materials and WPC samples. Some quantified compounds were considered WPC markers such as furfural, 2-methoxyphenol, N-methylphthalimide and 2,4-di-tert-butylphenol. Hexanoic acid, acetic acid, 2-methoxyphenol, acetylfuran, diacetyl, and aldehydes were the most important odorants. None of the VOCs were found to affect human safety for use of the WPC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soil Samplers: New Techniques for Subsurface Sampling for Volatile Organic Compounds

Soil sampling techniques for volatile organic analysis must be designed to minimize loss of volatile organic compounds (VOCs) from the soil that is being sampled. Preventing VOC loss from soil cores that are collected from the subsurface and brought to the surface for subsampling is often difficult. Subsurface bulk sample retrieval systems are designed to obtain intact cylindrical cores of soil ranging anywhere from one to four inches in diameter, and one to several feet in length. The current technique that is used to subsample these soil cores for VOC analysis is to expose a horizontal section of the soil core to the atmosphere; screen the exposed soil using a photoionization detector (PID) or other appropriate device to locate contamination in the soil core; and use a hand-operated coring tool to collect samples from the exposed soil for analysis. Because the soil core can be exposed to the atmosphere for a considerable length of time during screening and sample collection, the current sub-sampling technique provides opportunity for VOCs to be lost from the soil. This report describes three alternative techniques from the current technique for screening and collecting soil samples from subsurface soil cores for VOC analysis and field testing that has been done to evaluate the techniques. Based on the results of the field testing, ASTM D4547, Standard Guide for Sampling Waste and Soils for Volatile Organic Compounds, was revised to include information about the new techniques.

54 ENVIRONMENTAL SCIENCES↗

Comparing and contrasting In-Vial and full-scale systems for sparging volatile analytes

Here, in-vial sparging was demonstrated as an effective, practical alternative to a full-scale sparging system for supporting the analysis of volatile constituents. Using elemental mercury (Hg 0 ) and toluene as representative purgeable analytes, the mass removal for various sparge configurations was measured and a reduced order model was developed and validated. In the primary experiments, Hg 0 in the sparge gas was trapped on activated carbon or gold, thermally desorbed, and quantified using atomic absorption or atomic fluorescence spectroscopy. Toluene experiments using the same in-vial sparge apparatus and sparge parameters were performed to demonstrate the applicability of the reduced order model to a broad range of compounds. Toluene removal was tracked by measuring the remaining toluene in sparged aliquots using Ultraviolet-visible (UV–Vis) spectroscopy. For the sparging, flow rates varied from 25 to 75 mL/min for periods from 0 to 30 min. Sparge performance, mass removal as a function of time, and sparge gas volume were measured for both in-vial and full-scale systems. A model based on dimensionless Henry's Law coefficient, normalized sparge gas volume, and fractional extent of equilibrium matched the experimental data for both compounds and provides a practical tool for future applications. For the conditions tested in this study, the calibrated model indicated that the sparge gas in the in-vial system reached approximately 33% of its equilibrium value before exiting the water surface, while a full-scale system reached approximately 100%. The tests validated the quality, reproducibility, and predictability of sparging performance for both full scale and in-vial sparge systems. Related factors such as waste generation, worker risk, and labor were also assessed. Full scale sparge systems provide the advantage of lower detection levels due to larger sample volume, while the in-vial sparge systems provide advantages for most other factors; including automatability, reducing secondary wastes, lessening the need to clean and check the sparge apparatus, and lowering labor and costs. The data and associated reduced order model support continued development and deployment of in-vial sparge platforms as a practical option for analysis of purgeable analytes such as volatile organic compounds and volatile metals/organometallics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volatility of sodium, potassium, and cesium perrhenates determined by thermogravimetry

Here, in this study, we investigated the volatility of sodium, potassium, and cesium perrhenates using thermogravimetry (TG) performed on single salts and their binary mixed salts. We performed simultaneous TG and differential scanning calorimetry under a ramp heating condition at 10°C/min up to 1200°C to characterize volatilization behavior as a function of temperature. We also performed isothermal TG over a temperature range of 700 to 975°C to estimate the vapor pressures of the alkali perrhenates based on a modified Langmuir equation that relates the rate of free evaporation from the open surface to vapor pressure. In this paper, we discuss the results of our study on the temperature of evaporation and temperature-dependent vapor pressure of sodium, potassium, and cesium perrhenates in relation to rhenium volatilization behavior observed during melting of simulated waste glass.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvent hold tank sample results for MCU-15-815-816-817-818-819-820 November monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-815-816-817-818-819-820), pulled on 11/29/2015 for analysis. The samples were inspected, combined, and analyzed for composition. Chemical analysis of the composite sample MCU-15-815-816-817-818-819-820 indicated the TiDG, Isopar™L, and MaxCalix are at nominal levels. The modifier concentration is 3% below its nominal concentration. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent on November 28, 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 12.5 ± 3 micrograms of mercury per gram of solvent (or 10.4 μg/mL) was detected in this sample. The solids residues found at the bottom of the p-nut vial from sample MCU-15-815 were determined to be left-over pipe residues that were flushed into the sample and they were found to have no impact on the solvent purity or on the chemical and physical properties of the solvent. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-15-556-557-558: March 2015 Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-556, MCU-15-557, and MCU-15-558), pulled on 03/16/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-556-557-558 indicated a low concentration (~ 78 % of nominal) of the suppressor (TiDG) and concentrations of the extractant (MaxCalix), and of the modifier (CS-7SB) in the solvent that were slightly lower than nominal. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier are sufficient for continuing operation without adding a trim at this time. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). However, the p-nut vials that delivered the samples contained small (1 mm) droplets of oxidized modifier and amides (as detected by the FTIR analysis). In addition, up to 21 microgram of mercury per gram of solvent (or 17.4 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Demonstration Program Plan for RCRA Constituent Analysis of Solidified Wastes (Rev 8)

The Performance Demonstration Program (PDP) for Resource Conservation and Recovery Act (RCRA) constituents distributes test samples for analysis of volatile organic compounds (VOCs), semivolatile organic compounds (SVOCs), and metals in solid matrices. Each distribution of test samples is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD; DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department. The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the RCRA PDP. Participating laboratories demonstrate acceptable performance by successfully analyzing single- blind performance evaluation samples (subsequently referred to as PDP samples) according to the criteria established in this plan. PDP samples are used as an independent means to assess laboratory performance regarding compliance with the WAP quality assurance objectives (QAOs). The concentrations of analytes in the PDP samples address levels of regulatory concern and encompass the range of concentrations anticipated in waste characterization samples. The WIPP requires analyses of homogeneous solid wastes to demonstrate compliance with regulatory requirements. These analyses must be performed by laboratories that demonstrate acceptable performance in this PDP. These analyses are referred to as WIPP analyses, and the samples on which they are performed are referred to as WIPP samples. Participating laboratories must analyze PDP samples using the same procedures used for WIPP samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent hold tank sample results for MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017): Quarterly Report

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017) are reported. Analyses indicate that the modifier (CS-7SB) and the extractant (MaxCalix) concentrations are at their nominal recommended levels (169,000 mg/L and 46,300 mg/L respectively). The suppressor (TiDG) level has decreased to a steady state level of 673 mg/L well above the minimum recommended level (479 mg/L). This analysis confirms the Isopar™ addition to the solvent in January 18, 2017. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). Another impurity observed in the samples was mercury. Up to 38 ± 8 micrograms of mercury per mL of solvent was detected in these samples (the average of the CV-AA and XRF methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 8 and 9 (Tank 49H) or mixing of previously undisturbed areas of high mercury concentration in Tank 49H. The gamma level (0.21E5 dpm/mL) measured in the February SHT sample was one order of magnitude lower than the gamma levels observed in the December and January SHT samples. The February gamma level is consistent with the solvent being idle (since January 10, 2017). The gamma levels observed in the December and January SHT samples were consistent with previous monthly measurements where the process operated normally. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvent Hold Tank Sample Results for MCU-16-934-935-936: June 2016 Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-934-935-936), pulled on 07/01/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-934-935-936 indicated the Isopar™L concentration is above its nominal level (101%). The modifier (CS-7SB) and the TiDG concentrations are 8% and 29 % below their nominal concentrations. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 21.1 ± 4 micrograms of mercury per gram of solvent (or 17.5 μg/mL) was detected in this sample (as determined by the XRF method of undigested sample). The current gamma level (1.41E5 dpm/mL) confirmed that the gamma concentration has returned to previous levels (as observed in the late 2015 samples) where the process operated normally and as expected.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent hold tank sample results for MCU-15-914-915-916. December 2015 Monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-914-915-916), pulled on 12/22/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-914-915-916 indicated the TiDG, Isopar™L, and MaxCalix are at nominal levels. The modifier concentration is 3% below its nominal concentration. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in November 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, the Fourier transform infra-red spectroscopy (FTIR) method detected trace levels (a few ppm) of amides (more indicative of bacteria than a possible degradation product of TiDG). In addition, up to 18 ± 4 micrograms of mercury per gram of solvent (or 14.8 μg/mL) was detected in this sample. The current gamma concentration level (8.48E4 dpm/mL) confirmed that the gamma concentration has returned to the previous level where the process operated normally as expected. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent hold tank sample results for MCU-16-53-55. January 2016 Monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-53-54-55), pulled on 01/25/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-53-54-55 indicated the Isopar™L, and MaxCalix are at nominal levels. The modifier and TiDG concentrations are 3% and 23 % below their nominal concentrations. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent on November 28, 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, the Fourier transform infra-red spectroscopy (FTIR) method detected trace levels (a few ppm) of amides (a possible degradation product of TiDG). In addition, up to 21 ± 4 micrograms of mercury per gram of solvent (or 17.5 μg/mL) was detected in this sample. There appears to be a possible correlation between the mercury level and the TiDG concentration in the solvent. The current gamma level (9.16 E4 dpm/mL) confirmed that the gamma concentration has returned to previous level where the process operated normally and as expected. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyses and Comparison of Bulk and Coil Surface Samples from the DWPF Slurry Mix Evaporator

Sludge samples from the DWPF Slurry Mix Evaporator (SME) heating coil frame and coil surface were characterized to identify differences that might help identify heat transfer fouling materials. The SME steam coils have seen increased fouling leading to lower boil-up rates. Samples of the sludge were taken from the coil frame somewhat distant from the coil (bulk tank material) and from the coil surface (coil surface sample). The results of the analysis indicate the composition of the two SME samples are very similar with the exception that the coil surface sample shows ~5-10X higher mercury concentration than the bulk tank sample. Elemental analyses and x-ray diffraction results did not indicate notable differences between the two samples. The ICP-MS and Cs-137 data indicate no significant differences in the radionuclide composition of the two SME samples. Semi-volatile organic analysis revealed numerous organic molecules, these likely result from antifoaming additives. The compositions of the two SME samples also match well with the analyzed composition of the SME batch with the exception of significantly higher silicon, lithium, and boron content in the batch sample indicating the coil samples are deficient in frit relative to the SME batch composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results For MCU-15-750-751-752-: June Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-750, MCU-15-751, and MCU-15-752), pulled on 06/22/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-750-751-752 indicated a low concentration (~ 49 % of nominal) of the suppressor (TiDG) and slightly lower than nominal concentrations of the extractant (MaxCalix), and of the modifier (Cs-7SB) in the solvent. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier are sufficient for continuing operation without adding a trim at this time but it is recommended that an addition of TiDG, modifier and Isopar™L should be made in the near future. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). In addition, up to 13.9 micrograms of mercury per gram of solvent (or 11.5 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Capture of volatile fission products: present status and future perspectives - 15680

The performance of some adsorbent materials for retention of volatile fission products has been assessed. Two different zeolites (Zeolite 4A and silver-coated mordenite) have been chosen owing to their known capacity to entrap cesium and iodine, respectively. To this purpose experiments have been made with a pilot plant termed OGATA (Off-Gas Treatment Apparatus), installed at ENEA laboratories. The tests have been carried out by heating the volatile species at 900 deg. C and passing them through zeolite pellets with the help of argon as carrier gas. The products arising from the interaction with the zeolites have been analyzed mainly by X-rays diffractometry and scanning electron microscopy. The general conclusion from these experiments is that the retention of volatile elements, like cesium and iodine, occurs through a simple adsorption mechanism, which confirms the need to improve the trapping capacity of these materials, especially in view of the final disposal. Moreover, a metal-organic framework (MOF-5), as representative of the new class of materials proposed as adsorbents for volatile radionuclides has been taken into account. The metal-organic frameworks are a sub-family of the nano-porous crystals, characterized by metal-oxygen cages connected by organic bridges which currently attract intensive interest for their excellent potential for storing and separating gases. The synthesis of MOF-5 has been made according to a novel method reported in the literature. FTIR, XRD and Raman spectra, as well as SEM-EDS and thermal gravimetric analysis performed on the synthesized product are perfectly in agreement with current data and reveal the crystal structure of the MOF-5. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗