Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile organic compounds detected”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Bacterial volatile organic compound specialists in the phycosphere

Abstract Labile dissolved organic carbon in the surface oceans accounts for about one-fourth of carbon produced through photosynthesis and turns over on average every 3 days, fueling one of the largest engines of microbial heterotrophic production on the planet. Volatile organic compounds are poorly constrained components of dissolved organic carbon. Here, we detected 72 m/z signals, corresponding to unique volatile organic compounds, including petroleum hydrocarbons, totaling ~18.5 nM in the culture medium of a model diatom. In five cocultures with bacteria adapted to grow with this diatom, 1–59 m/z signals were depleted. Two of the most active volatile organic compound consumers, Marinobacter and Roseibium, contained more genes encoding volatile organic compound oxidation proteins, and attached to the diatom, suggesting volatile organic compound specialism. With nanoscale secondary ion mass spectrometry and stable isotope labeling, we confirmed that Marinobacter incorporated carbon from benzene, one of the depleted m/z signals detected in the co-culture. Diatom gross carbon production increased by up to 29% in the presence of volatile organic compound consumers, indicating that volatile organic compound consumption by heterotrophic bacteria in the phycosphere—a region of rapid organic carbon oxidation that surrounds phytoplankton cells—could impact global rates of gross primary production.

Environmental Sciences & Ecology↗

Native Fluorescence Detection Methods and Detectors for Naphthalene and/or Other Volatile Organic Compound Vapors

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds have been identified as serious health hazards. This is especially true for personnel working with JP8 jet fuel and other fuels containing naphthalene as well as other hazardous volatile organic compounds (VOCs). Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to naphthalene or other hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined. The badges employ a new native fluorescence based detection method to identify and differentiate VOCs. The particular focus of some embodiments are the detection and identification of naphthalene while other embodiments are directed to detection and identification of other VOCs like aromatic hydrocarbons such as benzene, toluene, and xylene.

Hug, William F.↗

Mass Spectra Deconvolution of Gaseous Mixtures Containing Volatile Organic Compounds

The Spacecraft Atmosphere Monitor (S.A.M.) analyzes all gaseous pollutants in the 1-150Th mass-to-charge range based on their positive-ion mass spectra. Of particular interest is the Trace Gas Analysis (TGA) mode of operation in which S.A.M detects minute amounts of volatile organic compounds (VOC). Pollutant component of the ambient air is sampled on demand in twenty full mass spectra per second. All spectra is accumulated in two-second intervals by an on-board Field Programmable Gate Arrays (FPGA) unit. Mass spectra represents the number of detected fragment ions in a given mass-to-charge ratio channel. Electron impact ionization of neutral molecules results in creation of numerous fragment ions and most of organic compounds will contribute several identical fragments. Despite the presence of these molecular isobars, we developed the deconvolution algorithm capable of identifying target species based on their characteristic fragmentation patterns. We investigate the efficiency of deconvolution algorithm as a function of mass resolution with which mass spectrum is acquired. Higher the mass resolution, better the chances are to distinguish between stereoisomers using their fragmentation propensities, but also results in higher data volumes to be processed by a set of small footprint software stacks hosted by an on-board computer. Finding the balance between deconvolution accuracy and generated data volume under time constrains and limited computing resources is the main topic of this study.

Darrach, M.↗

Glancing Angle Deposition in Gas Sensing: Bridging Morphological Innovations and Sensor Performances

Glancing Angle Deposition (GLAD) has emerged as a versatile and powerful nanofabrication technique for developing next-generation gas sensors by enabling precise control over nanostructure geometry, porosity, and material composition. Through dynamic substrate tilting and rotation, GLAD facilitates the fabrication of highly porous, anisotropic nanostructures, such as aligned, tilted, zigzag, helical, and multilayered nanorods, with tunable surface area and diffusion pathways optimized for gas detection. This review provides a comprehensive synthesis of recent advances in GLAD-based gas sensor design, focusing on how structural engineering and material integration converge to enhance sensor performance. Key materials strategies include the construction of heterojunctions and core–shell architectures, controlled doping, and nanoparticle decoration using noble metals or metal oxides to amplify charge transfer, catalytic activity, and redox responsiveness. GLAD-fabricated nanostructures have been effectively deployed across multiple gas sensing modalities, including resistive, capacitive, piezoelectric, and optical platforms, where their high aspect ratios, tailored porosity, and defect-rich surfaces facilitate enhanced gas adsorption kinetics and efficient signal transduction. These devices exhibit high sensitivity and selectivity toward a range of analytes, including NO2, CO, H2S, and volatile organic compounds (VOCs), with detection limits often reaching the parts-per-billion level. Emerging innovations, such as photo-assisted sensing and integration with artificial intelligence for data analysis and pattern recognition, further extend the capabilities of GLAD-based systems for multifunctional, real-time, and adaptive sensing. Finally, current challenges and future research directions are discussed, emphasizing the promise of GLAD as a scalable platform for next-generation gas sensing technologies.

Chemistry↗

Soil Sample Plan in Support of the Site 300 Explosives Waste Treatment Facility Ecological Risk Assessment Pursuant to the Hazardous Waste Facility Permit, Part V, Special Condition #14 a-f. August 2020

The Department of Toxic Substances Control issued the Final Hazardous Waste Facility Permit to Lawrence Livermore National Laboratory, Site 300 in 2017. As part of the continual process to ensure waste treatment emissions are not impacting ecological receptors, LLNL analyzed soil samples in the vicinity of the Explosive Waste Treatment Facility (EWTF) Burn Units (i.e., Burn Cage and Burn Pan) and the Detonation Pad. Soil samples were analyzed by EPA Solid Waste 846 Methods for furans, explosives, metals, and semivolatile compounds. In all samples, furans, explosives, and semi-volatile organic compounds were not detected. Metals were detected at concentrations below background levels. This soil sample plan will sample the same four downwind areas of the Burn Units and the same downwind areas of the Detonation, as well as including four new sample locations. The four new locations will be located to the northeast and southwest of the Burn Units and Detonation (as shown in Figure 3). The constituents to be analyzed are in Tables 2 and 3. Perchlorate was not identified as a constituent of concern in the 2007 Soil Sampling Plan. However, for this plan, all soil samples will be analyzed for perchlorate. After completion of the sampling event, a soil sample report will be submitted to DTSC in accordance with requirements specified in the Hazardous Waste Facility Permit, Part V, Special Conditions 16 a-f. This proposed soil sampling plan will be fully implemented no later than one year after receiving DTSC approval, in accordance with the Hazardous Waste Facility Permit, Part V, Special Condition 15.

54 ENVIRONMENTAL SCIENCES↗

Soil Sample Workplan in Support of the Site 300 Explosives Waste Treatment Facility Ecological Risk Assessment Pursuant to the Hazardous Waste Facility Permit (Part V, Special Condition #14 a-f)

The Department of Toxic Substances Control issued the Final Hazardous Waste Facility Permit to Lawrence Livermore National Laboratory, Site 300 in 2017. As part of the continual process to ensure waste treatment emissions are not impacting ecological receptors, LLNL analyzed soil samples in the vicinity of the Explosive Waste Treatment Facility (EWTF) Burn Units (i.e., Burn Cage and Burn Pan) and the Detonation Pad. Soil samples were analyzed by EPA Solid Waste 846 Methods for furans, explosives, metals, and semi-volatile compounds. In all samples, furans, explosives, and semi-volatile organic compounds were not detected. Metals were detected at concentrations below background levels. This soil sample plan will sample the same four downwind areas of the Burn Units and the same downwind areas of the Detonation, as well as including four new sample locations. The four new locations will be located to the northeast and southwest of the Burn Units and Detonation (as shown in Figure 3). The constituents to be analyzed are in Tables 7 and 8. Perchlorate was not identified as a constituent of concern in the 2007 Soil Sampling Plan. However, for this plan, all soil samples will be analyzed for perchlorate. Nitrate and all CAM17 metals have been added to the sampling plan to comply with DTSC comments received in correspondence dated June 4, 2021. After completion of the sampling event, a soil sample report will be submitted to DTSC in accordance with requirements specified in the Hazardous Waste Facility Permit, Part V, Special Conditions 16 a-f. This proposed soil sampling plan will be fully implemented no later than one year after receiving DTSC approval, in accordance with the Hazardous Waste Facility Permit, Part V, Special Condition 15.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Second-Generation Volatile Organic Analyzer for the International Space Station

Early in the development of the Crew Health Care System (CHECS) for the International Space Station (ISS), it was recognized that detection of target volatile organic compounds would be a key component of the air monitoring strategy. Experiences during the NASA/Mir program supported the decision to include a real-time volatile organic analyzer (VOA) aboard ISS to help assess the impact of air quality events on crew health and determine the effectiveness of decontamination efforts. Toward this end, a joint development by the Toxicology Laboratory at Johnson Space Center and Graseby Dynamics produced a VOA that has been delivered and is ready for the first 5 years of ISS operation. The first-generation VOA selection criteria included minimizing size, weight, and power consumption while maintaining analytical performance. Measuring available technologies against these criteria, a VOA system based upon gas chromatography/ion mobility spectrometry (GC/IMS) was selected in the mid-90's. However, as NASA looks forward to later-stage ISS operations and to new frontiers such as human exploration of Mars, the ISS VOA (weighing 43 kg and consuming 160 watts) must be replaced by a smaller, less resource-intensive device. This paper will present a possible second-gene ration VOA based upon the same technology as the first-generation unit. Utilizing GC/IMS technology again will permit the instrumental data and experience gained during the initial phase of ISS to be applied to later ISS phases and advanced spacecraft missions. During the past 3 years, efforts to reduce the size of ion mobility spectrometers have been pursued by Graseby Dynamics, the manufacturer of the first-generation VOA. The concept of operation, expected analytical performance, and estimated size of a fully functional second-generation VOA based upon GC/mini-IMS technology will be presented. Furthermore, results of initial laboratory evaluations will be shown.

Limero, Thomas↗

Seizure detection device

A method of detecting a seizure includes collecting volatile organic compounds with a collector material of a collector; separating a mixture of the volatile organic compounds into its constituent chemicals with a gas chromatography column; ionizing the constituent chemicals to create ionized chemicals and detecting the ionized chemicals; and analyzing the ionized chemicals to identify seizure-indicative volatile organic compounds.

Arnold, Gary Stephen↗

Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers

We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.

quadrupole ion trap↗

Miniaturized pulsed discharge ionization detector, non-radioactive ionization sources, and methods thereof

The present application relates to pulsed discharge ionization detectors (PDIDs) and non-radioactive ionization sources, including miniaturized forms thereof. In some examples, the PDID includes annular electrodes, where each electrode is disposed between annular insulators. Also provided herein are methods of making and using such PDIDs, such as for detecting one or more volatile organic compounds, as well as non-radioactive ionization sources.

42 ENGINEERING↗

Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined.

Hug, William F.↗

Native Fluorescence Detection Methods, Devices, and Systems for Organic Compounds

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds VOCs have been identified as serious health hazards. Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined.

Hug, William F.↗

Synthesis and application of thermally responsive nanofiber coatings for overtemperature monitoring

This study presents a one-pot synthesis route to organometallic nanofibers based on copper thiolate, exhibiting distinctive chemical and physical characteristics. Electron microscopy analysis of morphology and composition revealed 2-10 μm-long, 50-90 nm-diameter hollow and non-hollow fibers composed of copper, sulfur, oxygen, hydrocarbon, and chlorine. Thermogravimetric analysis showed a pronounced mass loss within 120°C-135°C. To elucidate the thermal responsive pathways, the nanofibers were characterized before and after heating. X-ray photoelectron spectroscopy indicates that an initially mixed Cu(I)/Cu(II) oxidation states transition to predominantly Cu(I) upon heating. A layer of nanofiber was coated on battery pouch foil and evaluated as a candidate thermally sensitive coating. At elevated temperature (100-130°C), nanofiber coating released volatile organic compounds, sulfide and sulfur dioxide as detected using multiple gas sensors. This thermally responsive gas release/sensing approach provides a potential large-area temperature monitoring strategy, which is particularly relevant where direct temperature measurements of individual batteries is impractical. The results established proof of concept for nanofiber-coated battery pouch foil as overtemperature warning platform that can provide alerts when surface temperatures exceed a critical threshold. More broadly, the ability to form interconnected fiber networks positions copper thiolate nanofiber coatings as promising materials for advanced applications.

Ihala Gamaralalage, Chanaka [ORNL] (ORCID:00000002↗

Laser-induced graphene gas sensors for environmental monitoring

Artemesia tridentatais a foundational plant taxon in western North America and an important medicinal plant threatened by climate change. Low-cost fabrication of sensors is critical for developing large-area sensor networks for understanding and monitoring a range of environmental conditions. However, the availability of materials and manufacturing processes is still in the early stages, limiting the capacity to develop cost-effective sensors at a large scale. In this study, we demonstrate the fabrication of low-cost flexible sensors using laser-induced graphene (LIG); a graphitic material synthesized using a 450-nm wavelength bench top laser patterned onto polyimide substrates. We demonstrate the effect of the intensity and focus of the incident beam on the morphology and electrical properties of the synthesized material. Raman analyses of the synthesized LIG show a defect-rich graphene with a crystallite size in the tens of nanometers. This shows that the high level of disorder within the LIG structure, along with the porous nature of the material provide a good surface for gas adsorption. The initial characterization of the material has shown an analyte response represented by a change in resistance of up to 5% in the presence of volatile organic compounds (VOCs) that are emitted and detected byArtemisiaspecies. Bend testing up to 100 cycles provides evidence that these sensors will remain resilient when deployed across the landscapes to assess VOC signaling in plant communities. The versatile low-cost laser writing technique highlights the promise of low-cost and scalable fabrication of LIG sensors for gas sensor monitoring.

Chemistry↗

Chemical ionization mass spectrometry utilizing benzene cations for measurements of volatile organic compounds and nitric oxide

We evaluate the capability of chemical ionization mass spectrometry (CIMS) using benzene cations as reagent ions (benzene CIMS) for detecting atmospheric trace gases. We characterize the ionization pathways and product ion distributions for 27 analytes spanning diverse chemical classes. To interpret the complex ion chemistry involving two reagent ions (C 6 H$^{+}_{6}$ and (C 6 H 6 )$^{+}_{2}$) and multiple ionization pathways (charge transfer, proton transfer, adduct formation, and hydride abstraction), we introduce a thermodynamics-based framework that classifies analytes into three categories based on their ionization energy (IE), relative to those of benzene monomer (9.24 eV) and dimer (8.69 eV). Each class exhibits distinct ionization mechanisms and product ions. Analytes with IE smaller than 8.69 eV (low IE) undergo charge transfer with both reagent ions; analytes with IE between 8.69 and 9.24 eV (mid IE) undergo charge transfer with C 6 H$^{+}_{6}$ and potential adduct formation with (C 6 H 6 )$^{+}_{2}$; analytes with IE larger than 9.24 eV (high IE) could undergo adduct formation, proton transfer, or hydride abstraction. Analytes within each class also show similar sensitivity, enabling sensitivity estimation for compounds lacking calibration standards. In addition to volatile organic compounds (VOCs), benzene CIMS detects nitric oxide (NO) with a detection limit of 5 pptv for 1 min integration time, exceeding the performance of most commercial NOx analyzers. Field deployments in Chicago and St. Louis demonstrate good agreement with reference NO measurements. Isoprene measurements show good agreement with a co-located gas chromatography–photoionization detector (GC-PID) in St. Louis, but exhibit substantial positive bias in Chicago, likely due to interferences from anthropogenic VOCs in the polluted urban environment. These results highlight the potential of benzene CIMS for concurrent measurements of NO, VOCs, and their oxidation products using a single instrument, while also underscoring challenges in complex atmospheric conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ExoMars Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Mass Spectrometry (LDI-MS) Analysis of Phototrophic Communities from a Silica-Depositing Hot Spring in Yellowstone National Park, USA

The Mars Organic Molecule Analyzer (MOMA) is a key scientific instrument on the ExoMars Rover mission. MOMA is designed to detect and characterize organic compounds, over a wide range of volatility and molecular weight, in samples obtained from up to two meters below the martian surface. Thorough analog sample studies are required to best prepare to interpret MOMA data collected on Mars. We present here the MOMA characterization of Mars analog samples collected from an alkaline silica depositing hot spring in Yellowstone National Park, WY, USA. These samples contain microbial streamer communities composed primarily of oxygenic and anoxygenic phototrophs. Additionally, in a study focused on detection of key classes of nonvolatile organics, samples of microbial streamers and their total lipid extract (TLE) have been measured on a MOMA Engineering Test Unit (ETU) instrument using its laser desorption/ionization mass spectrometry (LDI-MS) mode. MOMA LDI-MS detected a variety of lipids and pigments in the TLE sample. Species such as chlorophyll a were also detected from the streamer sample with the help of mass isolation. The results add to the LDI-MS sample characterization database, as well as demonstrate the benefit of using mass isolation on the MOMA instrument to reveal the presence of complex organics, and potential biomarkers, preserved in a natural sample, providing guidance to the in situ analysis of surface samples during Mars operations.

59 BASIC BIOLOGICAL SCIENCES↗

A New Field Instrument for Leaf Volatiles Reveals an Unexpected Vertical Profile of Isoprenoid Emission Capacities in a Tropical Forest

Both plant physiology and atmospheric chemistry are substantially altered by the emission of volatile isoprenoids (VI), such as isoprene and monoterpenes, from plant leaves. Yet, since gaining scientific attention in the 1950’s, empirical research on leaf VI has been largely confined to laboratory experiments and atmospheric observations. Here, we introduce a new field instrument designed to bridge the scales from leaf to atmosphere, by enabling precision VI detection in real time from plants in their natural ecological setting. With a field campaign in the Brazilian Amazon, we reveal an unexpected distribution of leaf emission capacities (EC) across the vertical axis of the forest canopy, with EC peaking in the mid-canopy instead of the sun-exposed canopy surface, and moderately high emissions occurring in understory specialist species. Compared to the simple interpretation that VI protect leaves from heat stress at the hot canopy surface, our results encourage a more nuanced view of the adaptive role of VI in plants. We infer that forest emissions to the atmosphere depend on the dynamic microenvironments imposed by canopy structure, and not simply on canopy surface conditions. We provide a new emissions inventory from 52 tropical tree species, revealing moderate consistency in EC within taxonomic groups. We highlight priorities in leaf volatiles research that require field-portable detection systems. Our self-contained, portable instrument provides real-time detection and live measurement feedback with precision and detection limits better than 0.5 nmol VI m -2 leaf s -1 . We call the instrument ‘PORCO’ based on the gas detection method: photoionization of organic compounds. We provide a thorough validation of PORCO and demonstrate its capacity to detect ecologically driven variation in leaf emission rates and thus accelerate a nascent field of science: the ecology and ecophysiology of plant volatiles.

54 ENVIRONMENTAL SCIENCES↗