Results for “Volatility analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quantitative analysis of volatile organic compounds using ion mobility spectra and cascade correlation neural networks

Ion Mobility Spectrometry (IMS) is a powerful technique for trace organic analysis in the gas phase. Quantitative measurements are difficult, because IMS has a limited linear range. Factors that may affect the instrument response are pressure, temperature, and humidity. Nonlinear calibration methods, such as neural networks, may be ideally suited for IMS. Neural networks have the capability of modeling complex systems. Many neural networks suffer from long training times and overfitting. Cascade correlation neural networks train at very fast rates. They also build their own topology, that is a number of layers and number of units in each layer. By controlling the decay parameter in training neural networks, reproducible and general models may be obtained.

Harrington, Peter DEB.↗

Analysis of Volatile Compounds from CO2 Removal Systems

One of the primary concerns when designing CO2 scrubber systems that will be integrated with a Sabatier reactor to produce water and methane is the amount of water released from the scrubber. Because the gas stream entering a Sabatier reactor must be compressed, water entering the reactor can condense and compromise the integrity of the system, thus rendering its valuable conversion capability useless. When the Johnson Space Center Environmental Chemistry Laboratory was tasked to develop an assay to quantify the water concentration in air samples from CO2 scrubbers, additional testing was also performed to see if any other compounds were being concentrated on the scrubbers. It was thought that the efficiency of the scrubber systems could be quantified by comparing the differences in samples from the ambient air on the International Space Station (ISS) to the exit gas of the scrubber. As this analysis was carried out, it became evident that the concentrations of certain volatile compounds were higher in the samples from the scrubbers than they were in nominal environmental samples. This meant these compounds were being retained and concentrated on the scrubber beds. Based on this finding, concerns were raised about their potential for these compounds to poison the Sabatier reactor. Further investigation was required to identify these compounds due to their high concentrations and unique matrix of the CO2 scrubber exhaust. This paper describes these events as well as the process that was developed to identify the volatile compounds that increased. An examination of how much the certain compounds can be concentrated by the scrubber systems is also included.

Volatiles↗

Analysis of Volatile Compounds From CO2 Removal Systems

One of the primary concerns when designing CO2 scrubber systems that will be integrated with a Sabatier reactor to produce water and methane is the amount of water released from the scrubber. Because the gas stream entering a Sabatier reactor must be compressed, water entering the reactor can condense and compromise the integrity of the system, thus rendering its valuable conversion capability useless. When the Johnson Space Center Environmental Chemistry Laboratory was tasked to develop an assay to quantify the water concentration in air samples from CO2 scrubbers, additional testing was also performed to see if any other compounds were being concentrated on the scrubbers. It was thought that the efficiency of the scrubber systems could be quantified by comparing the differences in samples from the ambient air on the International Space Station (ISS) to the exit gas of the scrubber. As this analysis was carried out, it became evident that the concentrations of certain volatile compounds were higher in the samples from the scrubbers than they were in nominal environmental samples. This meant these compounds were being retained and concentrated on the scrubber beds. Based on this finding, concerns were raised about their potential for these compounds to poison the Sabatier reactor. Further investigation was required to identify these compounds due to their high concentrations and unique matrix of the CO2 scrubber exhaust. This paper describes these events as well as the process that was developed to identify the volatile compounds that increased. An examination of how much the certain compounds can be concentrated by the scrubber systems is also included.

Volatiles↗

Pressure Analysis for LAVA-OVEN

The Lunar Advanced Volatiles Analysis (LAVA) and the Oxygen Volatiles Extraction Node (OVEN) are subsystems included in the Regolith Environment Science, and Oxygen Lunar Volatiles Extraction (RESOLVE) payload bound for the Moon in 2019. This Resource Prospector Mission (RPM) has the objective of landing on a shadowed region of the Moons South Pole to collect data and determine whether the resources could be effectively used for space exploration systems. The quantification of the resources will help understand if it can adequately minimize materials carried from Earth by: providing life support, propellants, construction materials or energy supply to the payload or crew. This paper outlines the procedures done for the pressure analysis of the LAVA-OVEN (LOVEN) Integration Testing. The pressure analysis quantifies how much gases and water are present in the sample tested during the Engineering Testing Unit (ETU) phase of instrument development. Ultimately the purpose of these tests is to improve the estimate of the amount of water in each Lunar sample and reduce the time necessary for this estimate. The governing principle that was used for the analysis is the Ideal Gas Law, PV=nRT where P stands for pressure, V for volume, n for number of moles, R being the gas constant and T for temperature. We also estimate the errors involved in these measured and derived quantities since a key objective of the mission is to estimate the quantity of volatiles present in the lunar samples introduced into OVEN.

Lunar↗

Analysis of Volatile Organic Compounds in a Controlled Environment: Ethylene Gas Measurement Studies on Radish

Volatile organic compound(VOC), ethylene gas, was characterized and quantified by GC/FID. 20-50 ppb levels were detected during the growth stages of radish. SPME could be a good analytical tool for the purpose. Low temperature trapping method using dry ice/diethyl ether and liquid nitrogen bath was recommended for the sampling process for GC/PID and GC/MS analysis.

Kong, Suk Bin↗

Analysis of volatile combustion products and a study of their toxicological effects.

An experimental program was conducted to study the thermochemical, flammability and toxicological characteristics of uncoated and coated polyisocyanurate foams. The coatings used were fluorinated copolymer and an intumescent material. Combustion and pyrolysis gases were analyzed by gas chromatography and mass spectrometry. The LD-50 and LD-100 tests were performed on Sprague-Dawley rats housed in an environmental chamber. The isocyanurate foam, fluorinated-copolymer-coated foam, and the intumescent-coated foam were found to have excellent flammability and insulation characteristics, although smoke development was substantial.

Seader, J. D.↗

Analysis of volatile organic compounds

An apparatus and method are described for reproducibly analyzing trace amounts of a large number of organic volatiles existing in a gas sample. Direct injection of the trapped volatiles into a cryogenic percolum provides a sharply defined plug. Applications of the method include: (1) analyzing the headspace gas of body fluids and comparing a profile of the organic volatiles with standard profiles for the detection and monitoring of disease; (2) analyzing the headspace gas of foods and beverages and comparing the profile with standard profiles to monitor and control flavor and aroma; and (3) analyses for determining the organic pollutants in air or water samples.

Zlatkis, A.↗

Analysis of volatile metabolites in biological fluids as indicators of prodromal disease condition

The volatile profile cannot be defined as a single class of substances, rather it is a broad spectrum of materials of different polarities characterized by having a boiling-point in the low to medium range (up to approximately 300 C) and the fact that the compounds are suitable for gas chromatography without derivatization. The organic volatile profiles are very complex mixtures of metabolic byproducts, intermediates, and terminal products of enzymatic degradations composed mainly of alcohols, ketones, aldehydes, pyrazines, sulfides, isothiocyanates, pyrroles, and furans. The concentration of organic volatiles in biological fluids covers a wide range with many important components present at trace levels. The complexity of the organic volatile fraction requires the use of capillary columns for their separation.

Zlatkis, A.↗

In situ extraction and analysis of volatiles and simple molecules in interplanetary dust particles, contaminants, and silica aerogel

Results are presented for the analyses of eight interplanetary dust particles (IDPs) for the volatile elements H, C, N, O, and S and their molecular species, as well as of the volatiles associated with contaminants (i.e., the compounds used during the collection and curation of IDPs), which were carried out using a laser microprobe interfaced with a quadrupole mass spectrometer. It was found that the volatile species from contaminants were always present in the spectra of IDPs. Despite the contamination problems, several indigenous molecular species could be identified, including OH, CO2 or C2H4, C and CS2, CO2 along with CO (possibly indicating the presence of carbonate), H2S, SO, COS, SO2, and CS2. In some cases, the sulfur components can be attributed to aerosols; however, in one of the IDPs, the presence of H2S, SO, COS, and SO2 indicates the possible presence of elemental sulfur.

Hartmetz, C. P.↗

In situ extraction and analysis of volatile elements and molecules from carbonaceous chondrites

A laser microprobe mass spectrometer was used to measure volatiles released, on a scale of 30-50 microns, from freshly broken, sawed, and weathered surfaces in fragments of the Allende, Murchison, Coolidge, Felix, and Orgueil carbonaceous chondrites. Samples were heated to about 120 C under a vacuum of 200 ntorr and illuminated with the focused beam of a Q-switched Nd:glass laser of variable energy output (0.1-1.0 J); the gases released were analyzed using a computer-controlled mass-selective detector. The results are presented in tables and graphs and discussed in detail, with particular attention to aqueous alteration; weathering; thermal metamorphism; the distribution of sulfur-bearing phases; and differences in the amounts of volatiles in matrix, inclusions, and chondrules.

Hartmetz, C. P.↗

Light Water Analysis and Volatile Extraction (Light WAVE)

The presence of water ice in permanently shadowed regions on the lunar sur-face may enable a sustained human presence on the Moon with minimal need for consumables. The first step toward utilizing lunar water ice to advance human space exploration will be to determine the abundance, accessibility, and distribution of this valuable resource.

Aaron J Paz↗

Mass spectrometric analysis of the volatiles released by heating or crushing rocks

Vacuum extraction with subsequent mass spectrometric analysis of evolved volatiles was selected as the analytical procedure. The high-vacuum gas-handling system was constructed of stainless steel. The system was completely free from mercury, grease, or volatile organic materials. The furnace for heating the samples is discussed together with the high-vacuum crusher, the mass spectrometer, and approaches for water determination. The analytical procedure is considered, giving attention to the extraction of volatiles, adsorption studies, and the analysis of volatiles.

Barker, C.↗

Characterization of a Carbon Nanotube Field Emission Electron Gun for the VAPoR Miniaturized Pyrolysis-Time-of-Flight Mass Spectrometer

We are developing the VAPoR (Volatile Analysis by Pyrolysis of Regolith) instrument towards studying soil composition, volatiles, and trapped noble gases in the polar regions of the Moon. VAPOR will ingest a soil sample and conduct analysis by pyrolysis and time-of-flight mass spectrometry (ToF-MS). Here, we describe miniaturization efforts within this development, including a carbon nanotube (CNT) field emission electron gun that is under consideration for use as the electron impact ionization source for the ToF-MS.

Getty, Stephanie↗

LAVA Subsystem Integration and Testing for the RESOLVE Payload of the Resource Prospector Mission: Mass Spectrometers and Gas Chromatography

The Regolith and Environment Science & Oxygen and Lunar Volatile Extraction (RESOLVE) payload is part of Resource Prospector (RP) along with a rover and a lander that are expected to launch in 2020. RP will identify volatile elements that may be combined and collected to be used for fuel, air, and water in order to enable deeper space exploration. The Resource Prospector mission is a key part of In-Situ Resource Utilization (ISRU). The demand for this method of utilizing resources at the site of exploration is increasing due to the cost of resupply missions and deep space exploration goals. The RESOLVE payload includes the Lunar Advanced Volatile Analysis (LAVA) subsystem. The main instrument used to identify the volatiles evolved from the lunar regolith is the Gas Chromatograph-Mass Spectrometer (GC-MS). LAVA analyzes the volatiles emitted from the Oxygen and Volatile Extraction Node (OVEN) Subsystem. The objective of OVEN is to obtain, weigh, heat and transfer evolved gases to LAVA through the connection between the two subsystems called the LOVEN line. This paper highlights the work completed during a ten week internship that involved the integration, testing, data analysis, and procedure documentation of two candidate mass spectrometers for the LAVA subsystem in order to aid in determining which model to use for flight. Additionally, the examination of data from the integrated Resource Prospector '15 (RP' 15) field test will be presented in order to characterize the amount of water detected from water doped regolith samples.

RESOLVE↗

Test and Recommendation of Flight-forward Resistive Temperature Detector for Resource Prospector Mission

The Resource Prospector Mission (RPM) is an in-situ resource utilization (ISRU) technology demonstration mission planned to launch in 2018. The mission will use the Regolith and Environment Science & Oxygen and Lunar Volatile Extraction (RESOLVE) Payload to prospect for lunar volatiles such as water, oxygen, and carbon dioxide. These compounds will validate ISRU capability. The payload, particularly the Lunar Advanced Volatile Analysis (LAVA) subsystem, requires numerous temperature measurements to accurately control on-board heaters that keep the volatiles in the vapor phase to allow quantification and prevent the clogging of delivery lines. Previous spaceflight missions have proven that Resistive Temperature Detector (RTD) failure impedes mission success. The research resulted in a recommendation for a flight-forward RTD. The recommendation was based on accuracy, consistency, and ease of installation of RTDs procured from IST, QTI, and Honeywell.

LAVA↗

Test and Recommendation of Flight-Forward Resistive Temperature Detector for Resource Prospector Mission

The Resource Prospector Mission (RPM) is an in-situ resource utilization (ISRU) technology demonstration mission planned to launch in 2018. The mission will use the Regolith and Environment Science & Oxygen and Lunar Volatile Extraction (RESOLVE) Payload to prospect for lunar volatiles such as water, oxygen, and carbon dioxide. These compounds will validate ISRU capability. The payload, particularly the Lunar Advanced Volatile Analysis (LAVA) subsystem, requires numerous temperature measurements to accurately control on-board heaters that keep the volatiles in the vapor phase to allow quantification and prevent the clogging of delivery lines. Previous spaceflight missions have proven that Resistive Temperature Detector (RTD) failure impedes mission success. The research resulted in a recommendation for a flight-forward RTD. The recommendation was based on accuracy, consistency, and ease of installation of RTDs procured from IST, QTI, and Honeywell.

LAVA↗

Percentage of Water Retained in Icy Lunar Regolith Simulant During Transfer into a Sample Container

We now know that water ice exists on the lunar surface thanks to the findings of multiple lunar missions such as LRO and LCROSS. However, before we develop systems that can utilize this precious resource at a useful scale, we need to acquire more data about the concentration of water in the lunar regolith and how it may vary by depth and location. The OVEN (Optimized Volatile Extraction Node) system is designed to determine the concentration of water as part of an instrument called WAVE (Water Analysis & Volatile Extraction) which can be deployed during a lunar resource prospecting mission. Experiments were carried out at the Johnson Space Center in order to better understand the potential losses of water that may occur during a prospecting mission when a sample is transferred from a drill to the OVEN. A description of the experiment as well as the results will be presented here.

ISRU↗