Search NASASearch

SEARCH · Search NASA

Results for “WALL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The role of wall calcium in the extension of cell walls of soybean hypocotyls

Calcium crosslinks are load-bearing bonds in soybean (Glycine max (L.) Merr.) hypocotyl cell walls, but they are not the same load-bearing bonds that are broken during acid-mediated cell elongation. This conclusion is reached by studying the relationship between wall calcium, pH and the facilitated creep of frozen-thawed soybean hypocotyl sections. Supporting data include the following observations: 1) 2-[(2-bis-[carboxymethyl]amino-5-methylphenoxy)methyl]-6-methoxy-8-bis[car boxymethyl]aminoquinoline (Quin 2) and ethylene glycol-bis(2-aminoethyl ether)-N,N,N',N'-tetraacetic acid (EGTA) caused only limited facilitated creep as compared with acid, despite removal of comparable or larger amounts of wall calcium; 2) the pH-response curves for calcium removal and acid-facilitated creep were different; 3) reversible acid-extension occurred even after removal of almost all wall calcium with Quin 2; and 4) growth of abraded sections did not involve a proportional loss of wall calcium. Removal of wall calcium, however, increased the capacity of the walls to undergo acid-facilitated creep. These data indicate that breakage of calcium crosslinks is not a major mechanism of cell-wall loosening in soybean hypocotyl tissues.

Non-NASA Center

Comparison of Turbulent Heat-Transfer Results for Uniform Wall Heat Flux and Uniform Wall Temperature

The purpose of this note is to examine in a more precise way how the Nusselt numbers for turbulent heat transfer in both the fully developed and thermal entrance regions of a circular tube are affected by two different wall boundary conditions. The comparisons are made for: (a) Uniform wall temperature (UWT); and (b) uniform wall heat flux (UHF). Several papers which have been concerned with the turbulent thermal entrance region problem are given. 1 Although these analyses have all utilized an eigenvalue formulation for the thermal entrance region there were differences in the choices of eddy diffusivity expressions, velocity distributions, and methods for carrying out the numerical solutions. These differences were also found in the fully developed analyses. Hence when making a comparison of the analytical results for uniform wall temperature and uniform wall heat flux, it was not known if differences in the Nusselt numbers could be wholly attributed to the difference in wall boundary conditions, since all the analytical results were not obtained in a consistent way. To have results which could be directly compared, computations were carried out for the uniform wall temperature case, using the same eddy diffusivity, velocity distribution, and digital computer program employed for uniform wall heat flux. In addition, the previous work was extended to a lower Reynolds number range so that comparisons could be made over a wide range of both Reynolds and Prandtl numbers.

Siegel, R.

Bioenergy sorghum stem density increases threefold following internode elongation due to continued accumulation of lignified cell walls and complex regulation of genes involved in cell wall biosynthesis

Bioenergy sorghum is a highly productive drought tolerant C4 grass that accumulates ~ 80% of its harvested biomass in ~ 4 m long stems comprised of > 40 internodes that develop sequentially during an extended vegetative growth phase. Following elongation of each internode, internode density increases ~ threefold to fourfold primarily due to the accumulation of cell walls composed of cellulose, glucuronoarabinoxylan and lignin. Lignin accumulates initially on cell walls of sclerenchyma cells surrounding vascular bundles and later on cell walls of the stem rind and stem core pith parenchyma. Many genes involved in cell wall biosynthesis were expressed continuously during the stem internode densification process whereas others showed dynamic patterns of expression (high to low, low to high). Several CESA genes involved in primary cell wall cellulose synthesis were expressed in the stem rind and core throughout the stem densification phase. In contrast, CESA genes involved in secondary cell wall biogenesis were expressed continuously in the stem rind but downregulated in the stem core shortly after completion of internode elongation. Overall, accumulation of cell wall biomass in elongated internodes during stem densification increases stem mechanical strength and biomass bulk density while modifying biomass composition in ways that could impact the amount and release of cellulosic sugars and lignin-derived bioproducts.

09 BIOMASS FUELS

Transonic wall interference assessment and corrections for airfoil data from the 0.3-meter TCT adaptive wall test section

The wall interference assessment/correction code presented is nonlinear, involves four walls, and is applicable to transonic airfoil data from wind tunnels with shaped, solid top and bottom walls. Attention is given to its application to data from the NASA 0.3-m Transonic Cryogenic Tunnel Adaptive Test Section, for two sizes of a NACA 0012 airfoil and to simulated data for an inviscid two-dimensional full-potential code. This study indicates that while adaptive wall wind tunnels significantly reduce some aspects of wall-interference effects (by comparison to straight solid and slotted wall wind tunnels), residual wall and other interference effects are present.

Green, Lawrence L.

Wall shear stress measurement in blade end-wall corner region

The magnitude and the direction of wall shear stress and surface pressure in the blade end-wall corner region were investigated. The measurements were obtained on a specially designed Preston tube, the tip of which could be concentrically rotated about its axis of rotation at the measurement location. The magnitude of wall shear stress in the vicinity of the corner was observed to increase significantly (170 percent) compared to its far-upstream value; the increase was consistently higher on the blade surface compared to the value on the plate surface of the blade end-wall corner. On both surfaces in the blade end-wall corner, the variation of the wall shear stress direction was found to be more predominant in the vicinity of the blade leading-edge location. The trend of the measured wall shear stress direction showed good agreement with the limiting streamline directions obtained from the flow visualization studies.

Bhargava, R.

Simultaneous axial conduction in the fluid and the pipe wall for forced convective laminar flow with blowing and suction at the wall

Numerical solutions are reported for conjugate heat transfer in a porous pipe having an internal flow with blowing or suction at the inner surface of the pipe and constant heat flux at the outer surface. The effect of the simultaneous axial conduction through the wall and the fluid has been studied for the combined hydrodynamic and thermal entry lengths. The results show that the ratio of the thermal conductivities of the pipe wall to the fluid and the thickness of the pipe wall may become significant factors on the heat transfer when the Peclet number is small, especially for the case when fluid is injected into the pipe. It is also shown that the effect of axial wall conduction for the case of constant heat flux at the outer wall surface can be neglected when the wall thickness is small and the ratio of the conductivities of the wall to the fluid approaches unity.

Faghri, Amir

Effect of uneven wall temperature on local heat transfer in a rotating square channel with smooth walls and radial outward flow

The effect of uneven wall temperature on the local heat transfer coefficient in a rotating square channel with smooth walls and radial outward flow is investigated for Reynolds numbers from 2500 to 25,000 and rotation numbers from 0 to 0.352. Three cases of thermal boundary conditions are studied: (1) four walls uniform temperature, (2) four walls uniform heat flux, and (3) leading and trailing walls hot and two side walls cold. It is shown that the heat transfer coefficients on the leading surface are much lower than that of the trailing surface due to rotation. For case 1, the leading surface heat transfer coefficient decreases and then increases with increasing rotation numbers, and the trailing surface heat transfer coefficient increases monotonically with rotation numbers. The trailing surface heat transfer coefficients, as well as those for the side walls, for case 2 are higher than for case 1, and the leading surface heat transfer coefficients for cases 2 and 3 are significantly higher than for case 1.

Han, J.-C.

Assessment of lift- and blockage-induced wall interference in a three-dimensional adaptive-wall tunnel

A three-dimensional adaptive-wall wind tunnel experiment was conducted at Ames Research Center. This experiment demonstrated the effects of wall interference on the upwash distribution on an imaginary surface surrounding a lifting wing. This presentation demonstrates how the interference assessment procedure used in the adaptive-wall experiments to determine the wall adjustments can be used to separately assess lift- and blockage-induced wall interference in a passive-wall wind tunnel. The effects of lift interference on the upwash distribution and on the model lift coefficient are interpreted by a simple horseshoe vortex analysis.

Schairer, E. T.

Comparison of NAE porous wall and NASA adaptive wall test results using the NAE CAST-10 airfoil model

Wind tunnels can now simulate flows over airfoils at high Reynolds numbers and high subsonic speeds. Methods to correct for (or reduce) test section wall interference at these test conditions must be validated. The National Aeronautics Establishment (NAE) of Canada and NASA have a cooperative agreement to study this area. The NAE designed, built, and tested a CAST-10 airfoil model in its conventional Two-Dimensional High Reynolds Number Facility. The results were corrected using classical correction techniques. NASA then tested the same model in its 0.3-meter Transonic Cryogenic Tunnel with the adaptive wall test section. The adaptive wall test section reduced the wall interference to what was expected to be an acceptable level. The corrected NAE results are compared with the uncorrected NASA results. The NAE results are also compared with NASA results after residual corrections for top and bottom wall interference. Finally, a comparison of both sets of results corrected for interference from all four walls is presented.

Mineck, Raymond E.

Wall Interference Study of the NTF Slotted Tunnel Using Bodies of Revolution Wall Signature Data

This paper is a description of the analysis of blockage corrections for bodies of revolution for the slotted-wall configuration of the National Transonic Facility (NTF) at the NASA Langley Research Center (LaRC). A wall correction method based on the measured wall signature is used. Test data from three different-sized blockage bodies and four wall ventilation settings were analyzed at various Mach numbers and unit Reynolds numbers. The results indicate that with the proper selection of the boundary condition parameters, the wall correction method can predict blockage corrections consistent with the wall measurements for Mach numbers as high as 0.95.

Iyer, Venkit

Wall Interference Study of the NTF Slotted Tunnel Using Bodies of Revolution Wall Signature Data

This paper is a description of the analysis of blockage corrections for bodies of revolution for the slotted-wall configuration of the National Transonic Facility (NTF) at the NASA Langley Research Center (LaRC). A wall correction method based on the measured wall signature is used. Test data from three different-sized blockage bodies and four wall ventilation settings were analyzed at various Mach numbers and unit Reynolds numbers. The results indicate that with the proper selection of the boundary condition parameters, the wall correction method can predict blockage corrections consistent with the wall measurements for Mach numbers as high as 0.95.

Iyer, Venkit

Controlled Patterning and Growth of Single Wall and Multi-wall Carbon Nanotubes

Method and system for producing a selected pattern or array of at least one of a single wall nanotube and/or a multi-wall nanotube containing primarily carbon. A substrate is coated with a first layer (optional) of a first selected metal (e.g., Al and/or Ir) and with a second layer of a catalyst (e.g., Fe, Co, Ni and/or Mo), having selected first and second layer thicknesses provided by ion sputtering, arc discharge, laser ablation, evaporation or CVD. The first layer and/or the second layer may be formed in a desired non-uniform pattern, using a mask with suitable aperture(s), to promote growth of carbon nanotubes in a corresponding pattern. A selected heated feed gas (primarily CH4 or C2Hn with n=2 and/or 4) is passed over the coated substrate and forms primarily single wall nanotubes or multiple wall nanotubes, depending upon the selected feed gas and its temperature. Nanofibers, as well as single wall and multi-wall nanotubes, are produced using plasma-aided growth from the second (catalyst) layer. An overcoating of a selected metal or alloy can be deposited, over the second layer, to provide a coating for the carbon nanotubes grown in this manner.

Lance D Delzeit

Smallholder Crop Area Mapped with Wall-To-Wall WorldView Sub-Meter Panchromatic Image Texture: A Test Case for Tigray, Ethiopia

Global food production in the developing world occurs within sub-hectare fields that are difficult to identify with moderate resolution satellite imagery. Knowledge about the distribution of these fields is critical in food security programs. We developed a semi-automated image segmentation approach using wall-to-wall sub-meter imagery with high-performance computing to map crop area (CA) throughout Tigray, Ethiopia that encompasses over 41,000 km (exp 2). Multiple processing streams were tested to minimize mapping error while applying five unique smoothing kernels to capture differences in land surface texture associated to CA. Typically, very-small fields (mean < 2 ha) have a smooth image roughness compared to natural scrub/shrub woody vegetation at the ~1m scale and these features can be segmented in panchromatic imagery with multi-level histogram thresholding. Multi-temporal very-high resolution (VHR) panchromatic imagery with multi-spectral VHR are sufficient in extracting critical CA information needed in food security programs. A 2011 to 2015 CA map was produced, using over 3000 WorldView-1 panchromatic images wall-to-wall in 1/2 deg mosaics for Tigray, Ethiopia. CA was evaluated with nearly 3000 WorldView-2 2m multispectral 250 X 250 m image subsets by seven expert interpretations, and with in-situ global positioning system photography. CA estimates ranged from 32 to 41% in sub regions of Tigray with median maximum per bin commission and omission errors of 11% and 1% respectively, with most of the error occurring in bins <15%. This empirical, simple, and low direct cost approach via U.S. government license agreement to access commercial VHR data, could be a viable big-data high-performance computing methodology to extract wall-to-wall CA for other regions of the world that have very-small agriculture fields with similar image texture."

Ethiopia

Reduction of wind-tunnel wall interference by controlled wall flow

Corrections for wind tunnel wall interferences are applied successfully to high lift models when the model to tunnel size ratio is small. The accuracy of the corrections becomes poorer when larger models are tested. An alternate method of testing was developed in which flow through the porous walls of the tunnel was actively controlled so as to approximate free air conditions in the neighborhood of the model during the test. The amount and distribution of the controlled flow through the walls is computed using a potential flow representation of the model based on the measured lift. Theoretical analysis is presented to prove the convergence of the method to free air conditions and to substantiate the general three dimensional theory of operation when the normal flow distribution is continuous. A two dimensional tunnel was constructed to evaluate the concept. Results show that substantial reduction of wall interference may be achieved with relatively low values of porosity of actively controlled walls.

Bernstein, S.

A detailed experimental study of the flow in the vicinity of the slotted wall of a wind tunnel with applications to the homogeneous slotted-wall boundary condition

The results of an experimental study of the flow in the vicinity of the slotted wall of a transonic wind tunnel are presented. A general description of the test setup and the wall configurations studied are given as are examples of the pressure data measured on the airfoil and the walls of the tunnel. The flow angles measured in the vicinity of the slot are examined with implications as to their use in the theory of homogeneous slotted walls. Preliminary values of the classical, homogeneous, slotted-wall boundary-condition coefficient are given and compared with theory.

Everhart, J. L.

Wall interference tests of a CAST 10-2/DOA 2 airfoil in an adaptive-wall test section

A wind-tunnel investigation of a CAST 10-2/DOA 2 airfoil model has been conducted in the adaptive-wall test section of the Langley 0.3-Meter Transonic Cryogenic Tunnel (TCT) and in the National Aeronautical Establishment High Reynolds Number Two-Dimensional Test Facility. The primary goal of the tests was to assess two different wall-interference correction techniques: adaptive test-section walls and classical analytical corrections. Tests were conducted over a Mach number range from 0.3 to 0.8 and over a chord Reynolds number range from 6 million to 70 million. The airfoil aerodynamic characteristics from the tests in the 0.3-m TCT have been corrected for wall interference by the movement of the adaptive walls. No additional corrections for any residual interference have been applied to the data, to allow comparison with the classically corrected data from the same model in the conventional National Aeronautical Establishment facility. The data are presented graphically in this report as integrated force-and-moment coefficients and chordwise pressure distributions.

Mineck, Raymond E.

Wall interference assessment/correction (WIAC) for transonic airfoil data from porous and shaped wall test sections

An existing computational wall interference assessment/correction (WIAC) procedure is applied to two sets of transonic airfoil data obtained from the same model tested in both a porous, planar-wall and a solid, shaped-wall test section. The published airfoil data from the porous test section agrees reasonably well with the published data from the shaped wall test section, although some differences exist. The WIAC procedure is applied to the data to assess and correct any wall interference effects; WIAC corrections generally improve the correlation between the two data sets. As an independent verification, both the published and WIAC corrected airfoil data are compared to Navier-Stokes calculations. Correlations are generally better between the WIAC corrected data and the Navier-Stokes calculations than between similar correlations with the published data.

Mineck, Raymond E.

Comparison of a two-dimensional adaptive-wall technique with analytical wall interference correction techniques

A two dimensional airfoil model was tested in the adaptive wall test section of the NASA Langley 0.3 meter Transonic Cryogenic Tunnel (TCT) and in the ventilated test section of the National Aeronautical Establishment Two Dimensional High Reynold Number Facility (HRNF). The primary goal of the tests was to compare different techniques (adaptive test section walls and classical, analytical corrections) to account for wall interference. Tests were conducted over a Mach number range from 0.3 to 0.8 at chord Reynolds numbers of 10 x 10(exp 6), 15 x 10(exp 6), and 20 x 10(exp 6). The angle of attack was varied from about 12 degrees up to stall. Movement of the top and bottom test section walls was used to account for the wall interference in the HRNF tests. The test results are in good agreement.

Mineck, Raymond E.