Search NASA⌕ Search

SEARCH · Search NASA

Results for “WATER REMOVAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Wash water solids removal system study

During wash water purification, surfactants tend to precipitate and foul the RO membranes, causing water flux decline and loss of salt rejection. The use of 165 to 190 ppm ferric chloride and optionally 0.25 to 1.0 ppm polymeric flocculate precipitates 92 to 96 percent of the surfactant from an Olive Leaf Soap based wash water. Crossflow filtration and pressure filtration yield good soap rejection at high water flux rates. Post-treatment of the chemically pretreated and filtered wash water with activated charcoal removes the residual soap down to an undetectable level.

Source record↗

A novel membrane device for the removal of water vapor and water droplets from air

One of the key challenges facing NASA engineers is the development of systems for separating liquids and gases in microgravity environments. In this paper, a novel membrane-based phase separator is described. This device, known as a water recovery heat exchanger (WRHEX), overcomes the inherent deficiencies of current phase-separation technology. Specifically, the WRHEX cools and removes water vapor or water droplets from feed-air streams without the use of a vacuum or centrifugal force. As is shown in this paper, only a low-power air blower and a small stream of recirculated cool water is required for WRHEX operation. This paper presents the results of tests using this novel membrane device over a wide range of operating conditions. The data show that the WRHEX produces a dry air stream containing no entrained or liquid water - even when the feed air contains water droplets or mist. An analysis of the operation of the WRHEX is presented.

Ray, Rod↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Mechanical Trash Compactor (Mpactor) for Exploration Missions

NASA is developing a mechanical trash compactor (Mpactor), a pneumatically driven trash compaction system, for human space exploration missions to manage trash items such as food packaging, sanitary wipes, clothing, tape, and other types of waste. The compaction system that is under development does not involve heating, water removal, or water recovery which eliminates the need for complex ancillary hardware required to manage gaseous effluents, as well as condense the water vapor. A system called the Crew Exploration Vehicle (CEV) Compactor, intended for use in the micro-gravity environment, was developed at NASA Ames Research Center for the Constellation Program 2007. This CEV Compactor is being further developed and renamed the Mpactor (short for mechanical trash compactor). The Mpactor is being used to gather engineering data that will allow engineers and planners to scale a future design for different mission scenarios and to evaluate different bag materials and designs that help retain compaction.

transit vehicle↗

Characterization of metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Characterization of the performance of a silver-oxide-based absorbent in terms of its ability to remove both gaseous CO2 and water vapor in an astronaut portable life support systems (PLSS) is discussed. Attention is focused on regeneration of the absorbent from the carbonite state of the oxide state, preconditioning of the absorbent using a humidified gas stream, and absorption breakthrough testing. Based on the results of bench-scale experiments, a test plan is carried out to further characterize the silver-oxide-based absorbent on a larger scale; it calls for examination of the absorbent in both an adiabatic packed bed and a near-isothermal cooled bed configuration. It is demonstrated that the tested absorbent can be utilized in a way that removes substantial amounts of CO2 and water vapor during an 8-hour extravehicular activity mission, and that applying the absorbent to PLSS applications can simplify the ventilation loop.

Kast, Timothy P.↗

Extended duration orbiter study: CO2 removal and water recovery

Two electrochemical depolarized carbon dioxide concentrator subsystems were evaluated against baseline lithium hydroxide for (1) the baseline orbiter when expanded to accommodate a crew of seven (mission option one), (2) an extended duration orbiter with a power extension package to reduce fuel cell expendables (mission option two), and (3) an extended duration orbiter with a full capability power module to eliminate fuel cell expendables (mission option three). The electrochemical depolarized carbon dioxide concentrator was also compared to the solid amine regenerable carbon dioxide removal concept. Water recovery is not required for Mission Option One since sufficient water is generated by the fuel cells. The vapor compression distillation subsystem was evaluated for mission option two and three only. Weight savings attainable using the vapor compression distillation subsystem for water recovery versus on-board water storage were determined. Combined carbon dioxide removal and water recovery was evaluated to determine the effect on regenerable carbon dioxide removal subsystem selection.

Marshall, R. D.↗

Understanding water management in platinum group metal-free electrodes using neutron imaging

Platinum group metal-free (PGM-free) catalysts are a low-cost alternative to expensive PGM catalysts for polymer electrolyte fuel cells. However, due to the low volumetric activity of PGM-free catalysts, the catalyst layer thickness of the PGM-free catalyst electrode is an order of magnitude higher than PGM based electrodes. The thick PGM-free electrodes suffer from increased transport resistance and poor water management, which ultimately limits the fuel cell performance. This manuscript presents the study of water management in the PGM-free electrodes to understand the transport limitations and improve fuel cell performance. Here, in-operando neutron imaging is performed to estimate the water content in different components across the fuel cell thickness. Water saturation in thick PGM electrodes, with similar catalyst layer thickness to PGM-free electrodes, is lower than in the PGM-free electrodes irrespective of the operating conditions, due to high water retention by PGM-free catalysts. Improvements in fuel cell performance are accomplished by enhancing water removal from the flooded PGM-free electrode in three ways: (i) enhanced water removal with a novel microporous layer with hydrophilic pathways incorporated through hydrophilic additives, (ii) water removal through anode via novel GDL in the anode, and (iii) lower water saturation in PGM-free electrode structures with increased catalyst porosity.

25 ENERGY STORAGE↗

Metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Recent studies of Allied Signal metal oxide based absorbents demonstrated that these absorbents offer a unique capability to regeneratively remove both metabolic carbon dioxide and water vapor from breathing air; previously, metal oxides were considered only for the removal of CO2. The concurrent removal of CO2 and H2O vapor can simplify the astronaut Portable Life Support System (PLSS) by combining the CO2 and humidity control functions into one regenerative component. The use of metal oxide absorbents for removal of both CO2 ad H2O vapor in the PLSS is the focus of an ongoing program. The full scale Metal Oxide Carbon dioxide and Humidity Remover (MOCHR) and regeneration unit is described.

Hart, Joan M.↗

Energetics of water expulsion from intervening space between two particles during aggregation

Solvent expulsion away from an intervening region between two approaching particles plays important roles in particle aggregation yet remains poorly understood. Here, in this work, we use metadynamics molecular simulations to study the free energy landscape of removing water molecules from gibbsite and pyrophyllite slit pores representing the confined spaces between two approaching particles. For gibbsite, removing water from the intervening region is both entropically and enthalpically unfavorable. The closer the particles approach each other, the harder it is to expel water molecules. For pyrophyllite, water expulsion is spontaneous, which is different from the gibbsite system. A smaller pore makes the water removal more favorable. When water is being drained from the intervening region, single chains of water molecules are observed in gibbsite pore, while in pyrophyllite pore water cluster is usually observed. Water-gibbsite hydrogen bonds help stabilize water chains, while water forms clusters in pyrophyllite pore to maximize the number of hydrogen bonds among themselves. This work provides the first assessment into the energetics and structure of water being drained from the intervening region between two approaching particles during oriented attachment and aggregation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Zeolitic Imidazole Framework Decorated Substrates for Lead Removal From Water

Lead contamination in water supplies necessitates efficient and mechanistically understood removal strategies. Zeolitic imidazole frameworks (ZIFs) are promising adsorbents; however, ZIF-67 (Co-based) is more susceptible to hydrolysis than its zinc analogue ZIF-8, raising questions about stability during metal uptake. In this study, we systematically compare ZIF-8 and ZIF-67 under controlled pH conditions and evaluate how substrate anchoring influences hydrolytic stability and Pb 2+ adsorption behavior. By integrating adsorption capacity measurements, kinetic analysis, metal-node leaching data, and structural characterization, we distinguish ion exchange from framework degradation and clarify the temporal interplay between adsorption and hydrolysis. Although ZIF-67 exhibits greater hydrolytic sensitivity, coordination with phosphoryl-bearing Mucor hiemalis membranes significantly reduces Co 2+ leaching and enhances structural retention. Under the optimized conditions (pH 5), ZIF-67@Mucor achieves a maximum Pb 2+ adsorption capacity of 867 mg g −1 . These findings demonstrate that substrate-dependent stabilization enables controlled exploitation of ZIF reactivity for aqueous metal remediation.

Adsorption↗

Removing Solids From Supercritical Water

Apparatus removes precipitated inorganic salts and other solids in water-recycling process. Designed for use with oxidation in supercritical water which treats wastes and yields nearly pure water. Heating coils and insulation around vessel keep it hot. Locking bracket seals vessel but allows it to be easily opened for replacement of filled canisters.

Hong, Glenn T.↗

Plaster core washout tool

Tool powered by pressurized water or air removes water soluble plaster lining from Kevlar/epoxy duct. Rotating plastic cutterhead with sealed end fitting connects flexible shaft that allows tool to be used with curved ducts.

Heisman, R. M.↗

Increased fuel-cell cross-pressure limit

Polytetrafluoroethylene (PTFE) impregnated support screen increases cross pressure on electrolyte-filled matrix in fuel-cell passive water-removed unit. This increases cell operating pressure limit which may improve performance and life characteristics of passive water-removal-type fuel cells.

Bell, W. F.↗

Defect engineering of porous aromatic frameworks via end capping improves dioxane removal from water

Amorphous porous organic polymers show promise for energy-efficient adsorptive separations, but it is difficult to understand or improve their performance through intentional structural modification. Herein, we report the synthesis of porous aromatic frameworks (PAFs) with pore structures tailored by the incorporation of a monofunctionalized end-capping monomer that disrupts framework topology. Combining experimental characterization with molecular simulations, we show that this defect engineering strategy yields less densely crosslinked networks, which leads to pore collapse and the presence of unique adsorption sites. These defect-engineered PAFs exhibit enhanced removal of 1,4-dioxane, an important environmental pollutant, from water. Increasing the concentration of end-capping monomers produces PAFs with narrower pore size distributions and improved 1,4-dioxane uptake. These results illustrate that defect engineering can effectively modulate polymer connectivity and porosity for applications in selective adsorptive separations. In conclusion, this technique avoids post-synthetic treatments and presents another approach to tailor amorphous polymeric adsorbents.

36 MATERIALS SCIENCE↗

Electrodeionization Salt Removal from Water

This project developed a method to selectively extract sodium (Na) from complex, mission-relevant wastewaters using electricity as a driving force. The team investigated capacitive deionization (CDI), which has been used for general desalination but not for selective removal of Na. Three tasks supported this overall aim: designing and building a reactor and electrodes, engineering absorption and desorption parameters, and investigating varying water compositions and sources. Potential benefits of this approach include integrating into existing Environmental Control & Life Support Systems (ECLSS) treatment trains, reducing salinity for hydroponic installations, and producing food preservatives. Significant accomplishments, including building new reactors and characterizing their optimal operations and applications, advance the frontier of in-situ resource utilization for planetary habitation.

Luke Roberson↗

Intergranular corrosion of Ni-30Cr in high-temperature hydrogenated water after removing surface passivating film

Abstract High-resolution transmission electron microscopy and atom probe tomography are used to characterize the initial passivation and subsequent intergranular corrosion of degraded grain boundaries in a model Ni-30Cr alloy exposed to 360 °C hydrogenated water. Upon initial exposure for 1000 h, the alloy surface directly above the grain boundary forms a thin passivating film of Cr 2 O 3 , protecting the underlying grain boundary from intergranular corrosion. However, the metal grain boundary experiences severe Cr depletion and grain boundary migration during this initial exposure. To understand how Cr depletion affects further corrosion, the local protective film was sputtered away using a glancing angle focused ion beam. Upon further exposure, the surface fails to repassivate, and intergranular corrosion is observed through the Cr-depleted region. Through this combination of high-resolution microscopy and localized passive film removal, we show that, although high-Cr alloys are resistant to intergranular attack and stress corrosion cracking, degradation-induced changes in the underlying metal at grain boundaries make the material more susceptible once the initial passive film is breached.

(S)TEM↗

Novel Approaches to the Isolation of Glucaric Acid from Fermentation Broth. Final report

Kalion has successfully demonstrated a fermentation route using glucose as the feedstock. This game-changing technology allows Kalion to economically produce large-scale quantities of high-purity glucaric acid products. Kalion has also developed a novel downstream processing strategy for isolating and purifying glucaric acid forms, including the free acid, monoammonium glucarate, and monopotassium glucarate. Despite the low solubility of these products, significant water removal is needed prior to crystallization, requiring energy intensive evaporation or reverse osmosis. Here, we work in collaboration with the Separations Consortium to develop novel, low-cost means of water removal in Kalion’s glucarate/glucaric acid purification process. This proposed CRADA project with national labs (ORNL, ANL, and NREL) evaluated various technologies developed by the Separations Consortium as applied to glucaric acid purification, intended to generate a scalable, cost-effective, energy-efficient process. Four approaches were evaluated with mock aqueous solutions of glucaric acid or glucarate, and the results analyzed with respect to separation effectiveness and potential cost savings. The leading technology will then be further developed and tested with actual clarified or non-clarified broth (depending on the approach) obtained from 20L fermentations provided by Kalion, that will contain inorganic ions, byproducts, and residual sugars in addition to the product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Hydrophilic, Composite Membranes for Air Removal from Water Coolant Systems

Liquid coolants are commonly used as thermal transport media to increase efficiency and flexibility in aerospace vehicle design. The introduction of gas bubbles into the coolant can have negative consequences, including: loss of centrifugal pump prime, irregular sensor readings, and blockage of coolant flow to remote systems. One solution to mitigate these problems is the development of a passive gas removal device, or gas trap, installed in the flight cooling system. In this study, a new hydrophilic, composite membrane has been developed for passage of the coolant fluid and retention of gas bubbles. The trapped bubbles are subsequently vented from the system by a thin, hydrophobic, microporous membrane. The original design for this work employed a homogeneous membrane that was susceptible to fouling and pore plugging. Spare gas traps of this variety have degraded during storage, and recreation of the membranes has been complicated due to problems with polymer duplication and property variations in the final membranes. In this work, replacements have been developed based on deposition of a hydrophilic polymer on the bore-side of a porous polyethylene (PE) tube. The tube provides excellent chemical and mechanical stability, and the hydrophilic layer provides retention of gas bubbles. Preliminary results have shown that intimate contact is required between the deposited layer and the substrate to overcome material differences. This has been accomplished by presoaking the membrane tube in the solvent to raise its surface energy. Polymer solutions of various concentrations have been used to promote penetration of the polymer layer into the porous substrate and to control separation layer thickness. The resulting composite membranes have shown repeatable decrease in nitrogen permeability, which is indicative of a decrease in membrane pore size. Studies with water permeation have yielded similar results. We have observed some swelling of the added polymer layer, which causes a slight decrease in membrane pore size, and should result in improved bubble retention. Preliminary studies have also been performed on gas retention in flowing systems. Initial results have been promising, with negligible gas permeation for the coated membranes compared to 100% gas permeation in the uncoated tube.

Ritchie, Stephen M. C.↗