Search NASA⌕ Search

SEARCH · Search NASA

Results for “WHITE LIGHT FRINGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Star Confusion Effect on SIM PlanetQuest Astrometric Performance

SIM PlanetQuest will measure star positions to an accuracy of a few microarcseconds using precise white light fringe measurements. One challenge for SIM observation scenario is "star confusion," where multiple stars are present in the instrument field of view. This is especially relevant for observing dim science targets because the density of number of stars increases rapidly with star magnitude. We study the effect of star confusion on the SIM astrometric performance due to systematic fringe errors caused by the extra photons from the confusion star(s}. Since star confusion from multiple stars may be analyzed as a linear superposition of the effect from single star confusion, we quantify the astrometric errors due to single star confusion surveying over many spectral types, including AOV, FOV, K5III, and MOV, and for various visual magnitude differences. To the leading order, the star confusion effect is characterized by the magnitude difference, spectral difference, and the angular separation between the target and confusion stars.Strategies for dealing with star confusion are presented. For example, since the presence of additional sources in the field of view leads to inconsistent delay estimates from different channels, with sufficient signal to noise ratio, the star confusion can be detected using chi-square statistics of fringe measurements from multiple spectral channels. An interesting result is that the star confusion can be detected even though the interferometer cannot resolve the separation between the target and confusion stars when their spectra are sufficiently different. Other strategies for mitigating the star confusion effect are also discussed.

crowded field↗

The StarLight Space Interferometer: Optical design and performance modeling

The StarLight mission aimed to place the first formation flying optical interferometer into space in year 2006. Utilizing two spacecraft to form a long baseline Michelson interferometer, it would measure white light fringes on a number of partially resolved stars of magnitudes >5 in the wavelength range 600 to 1000nm. The interferometer baseline is variable between 30 and 125 m, and also has a fixed 1 m mode. The spacecraft are flown in a parabolic geometry which requires an optical delay line to build up more than 14m of delay on one arm of the interferometer. To obtain high fringe visibility, starlight wavefront, pointing and intensity must be preserved through 22 reflections from mirrors and beamsplitters. The alignment of a total of 27 optics is maintained through careful thermal design and the use of two actuated mirrors on each arm. This paper describes the optical layout in depth, including the beam combiner design which allows star tracking, optical system alignment and fringe formation on a single CCD. The effects of diffraction of the starlight transferred from a distant spacecraft and from optical surface imperfections are modeled. Other contributors to the visibility budget and the resulting variation of fringe visibility across the focal plane are discussed .

StarLight↗

Method and apparatus for white-light dispersed-fringe interferometric measurement of corneal topography

An novel interferometric apparatus and method for measuring the topography of aspheric surfaces, without requiring any form of scanning or phase shifting. The apparatus and method of the present invention utilize a white-light interferometer, such as a white-light Twyman-Green interferometer, combined with a means for dispersing a polychromatic interference pattern, using a fiber-optic bundle and a disperser such as a prism for determining the monochromatic spectral intensities of the polychromatic interference pattern which intensities uniquely define the optical path differences or OPD between the surface under test and a reference surface such as a reference sphere. Consequently, the present invention comprises a snapshot approach to measuring aspheric surface topographies such as the human cornea, thereby obviating vibration sensitive scanning which would otherwise reduce the accuracy of the measurement. The invention utilizes a polychromatic interference pattern in the pupil image plane, which is dispersed on a point-wise basis, by using a special area-to-line fiber-optic manifold, onto a CCD or other type detector comprising a plurality of columns of pixels. Each such column is dedicated to a single point of the fringe pattern for enabling determination of the spectral content of the pattern. The auto-correlation of the dispersed spectrum of the fringe pattern is uniquely characteristic of a particular optical path difference between the surface under test and a reference surface.

Hochberg, Eric B.↗

Observational Model for Precision Astrometry with the Space Interferometry Mission

The Space Interferometry Mission (SIM) is a space-based 10-m baseline Michelson optical interferometer operating in the visible waveband that is designed to achieve astrometric accuracy in the single digits of the microarcsecond domain. Over a narrow field of view SIM is expected to achieve a mission accuracy of 1 microarcsecond. In this mode SIM will search for planetary companions to nearby stars by detecting the astrometric "wobble" relative to a nearby reference star. In its wide-angle mode, SIM will provide 4 microarcsecond precision absolute position measurements of stars, with parallaxes to comparable accuracy, at the end of its 5-year mission. The expected proper motion accuracy is around 3 microarcsecond/year, corresponding to a transverse velocity of 10 m/ s at a distance of 1 kpc. The basic astrometric observable of the SIM instrument is the pathlength delay. This measurement is made by a combination of internal metrology measurements that determine the distance the starlight travels through the two arms of the interferometer, and a measurement of the white light stellar fringe to find the point of equal pathlength. Because this operation requires a non-negligible integration time, the interferometer baseline vector is not stationary over this time period, as its absolute length and orientation are time varying. This paper addresses how the time varying baseline can be "regularized" so that it may act as a single baseline vector for multiple stars, as required for the solution of the astrometric equations.

TILE OBSERVATIONS↗

The Effect of Companions on the SIM Reference Frame

The Space Interferometry Mission (SIM) is a 10-m Michelson space-based optical interferometer designed for precision astrometry (4 microarcseconds, 3 microarcseconds/year) with better accuracy than before over a narrow field of view. One of the primary objectives of the SIM instrument is to determine accurately the directions to a grid of stars, together with their proper motions and parallax, improving a priori knowledge by nearly three orders of magnitude over Hipparcos and one order of magnitude over FAME's planned accuracy (Johnston, 2000). The instrument does not measure directly the angular separation between stars, but rather it measures the projection of each star's direction vector onto the interferometer baseline vector by measuring the pathlength delay of starlight as it passes through the two arms of the interferometer. The accuracy and stability of SIM's celestial reference frame is subject to degradation over the 5-year mission from the reflex motion induced by massive companions of the objects used to construct the celestial reference frame. The authors present the results of simulations that show the sensitivity of reference frame accuracy to companions as a function of mass and period. They assume that pre-launch ground surveys will eliminate all objects with RMS radial velocity greater than 10 m/s. They further assume that the standard astrometric parameters of position, parallax, and proper motion plus acceleration terms in right ascension and declination will be allowed to absorb reflex motion.

ASTROMETRY↗

Analysis of Calibration Errors for Both Short and Long Stroke White Light Experiments

This work will analyze focusing and tilt variations introduced by thermal changes in calibration processes. In particular the accuracy limits are presented for common short- and long-stroke experiments. A new, simple, practical calibration scheme is proposed and analyzed based on the SIM PlanetQuest's Micro-Arcsecond Metrology (MAM) testbed experiments.

instruments↗

White light modeling, algorithm development, and validation on the micro-arcsecond metrology testbed

The Space Interferometry Mission (SIM), scheduled for launch in early 2010, is an optical interferometer that will perform narrow angle and global wide angle astrometry with unprecedented accuracy, providing differential position accuracies of 1uas, and 4uas global accuracies in position, proper motion and parallax. SIM astrometric measurements are synthesized from pathlength delay measurements provided by three Michelson-type, white light interferometers. Two of the interferometers are used for making precise measurements of variations in the spacecraft attitude, while the third interferometer performs the science measurement. The ultimate performance of SIM relies on a combination of precise fringe measurements of the interfered starlight with picometer class relative distance measurements made between a set of fiducials that define the interferometer baseline vectors. The focus of the present paper is on the development and analysis of algorithms for accurate white light fringe estimation, and on the preliminary validation of these algorithms on the Micro-Arcsecond Testbed (MAM).

Shen, Janice TsaePyng↗

White Light Modeling, Algorithm Development, and Validation on the Micro-arcsecond Metrology Testbed

The Space Interferometry Mission (SIM) scheduled for launch in early 2010, is an optical interferometer that will perform narrow angle and global wide angle astrometry with unprecedented accuracy, providing differential position accuracies of 1uas, and 4uas global accuracies in position, proper motion and parallax. The astrometric observations of the SIM instrument are performed via delay measurements provided by three Michelson-type, white light interferometers. Two 'guide' interferometers acquire fringes on bright guide stars in order to make highly precise measurements of variations in spacecraft attitude, while the third interferometer performs the science measurement. SIM derives its performance from a combination of precise fringe measurements of the interfered starlight (a few ten-thousandths of a wave) and very precise (tens of picometers) relative distance measurements made between a set of fiducials. The focus of the present paper is on the development and analysis of algorithms for accurate white light estimation, and on validating some of these algorithms on the MicroArcsecond Testbed.

metrology↗

Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method and apparatus for checking the stability of a setup for making reflection type holograms

A method and apparatus are described for checking the stability of a setup for recording reflection-type (white light) holograms. Two sets of interference fringes are simultaneously obtained, one giving information about coherence and stability of the setup alone and the other demonstrating coherence of the entire system, including the holographic recording plate. Special emphasis is given to the stability of the plate, due to the fact that any minute vibration might severely degrade or completely destroy the recording.

Lackner, H. G.↗

The Least-Squares Calibration on the Micro-Arcsecond Metrology Test Bed

The Space Interferometry Mission (S1M) will measure optical path differences (OPDs) with an accuracy of tens of picometers, requiring precise calibration of the instrument. In this article, we present a calibration approach based on fitting star light interference fringes in the interferometer using a least-squares algorithm. The algorithm is first analyzed for the case of a monochromatic light source with a monochromatic fringe model. Using fringe data measured on the Micro-Arcsecond Metrology (MAM) testbed with a laser source, the error in the determination of the wavelength is shown to be less than 10pm. By using a quasi-monochromatic fringe model, the algorithm can be extended to the case of a white light source with a narrow detection bandwidth. In SIM, because of the finite bandwidth of each CCD pixel, the effect of the fringe envelope can not be neglected, especially for the larger optical path difference range favored for the wavelength calibration.

interferometer calibrations↗

Multiplexable high-temperature stable and low-loss intrinsic Fabry-Perot in-fiber sensors through nanograting engineering

This paper presents a method of using femtosecond laser inscribed nanograting as low-loss– and high-temperature–stable in-fiber reflectors. By introducing a pair of nanograting inside the core of a single-mode optical fiber, an intrinsic Fabry-Perot interferometer can be created for high-temperature sensing applications. The morphology of the nanograting inscribed in fiber cores was engineered by tuning the fabrication conditions to achieve a high fringe visibility of 0.49 and low insertion loss of 0.002 dB per sensor. Using a white light interferometry demodulation algorithm, we demonstrate the temperature sensitivity, cross-talk, and spatial multiplexability of sensor arrays. Both the sensor performance and stability were studied from room temperature to 1000°C with cyclic heating and cooling. Our results demonstrate a femtosecond direct laser writing technique capable of producing highly multiplexable in-fiber intrinsic Fabry-Perot interferometer sensor devices with high fringe contrast, high sensitivity, and low-loss for application in harsh environmental conditions.

Wang, Mohan (ORCID:0000000166784993)↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

A two-dimensional white-light amplitude interferometer

A review of the applications of a point-symmetric, 180-degree, rotational shearing interferometer is given. Material includes, photographs of the Michelson stellar interferometer fringes from Alpha-Lyr, measures of amplitude of phase excursions in the atmosphere, and a measure of the order of interference of speckle patterns. New material includes unpublished double star speckle patterns to illustrate the isoplanatic patch, a measure of the time fluctuations in the earth's atmosphere, and measurements of the properties of a 256 channel linear reticon.

Breckinridge, J. B.↗

Carbon suboxide polymer, an explanation for the wave of darkening on Mars

The carbon suboxide thermal polymer or its irradiated product is affected by water vapor. The polymerized carbon suboxide simulates the Martian wave of darkening on the inner wall of a glass tube when humidified by passage of water vapor through the tube. The polymer was visibly darkened by the advancing vapor front. With increasing polymer thickness and/or water vapor concentration the wave of darkening similarly intensifies simulating the dark fringe in the Martian circumpolar areas. Surfaces are lightened constantly being renewed by particulate material settling from the atmosphere. It is hypothesized that light and dark areas have polymer coatings, but light areas have small particles which scatter white light more effectively and appear brighter on the surface of Mars.

Oyama, V. I.↗

A white-light amplitude interferometer with 180-degree rotational shear

The paper reports on the fabrication, alignment, and test techniques of an equal-path, wave-front, folding amplitude interferometer with 180-degree rotational shear. The device may be used for measuring atmospheric phase-perturbing properties and designing optical filters used in processing spatial information. The instrument has been used to photograph the Michelson Stellar interferometer fringes.

Breckinridge, J. B.↗

SIM Narrow and wide angle astrometric demonstration on the MAM testbed.

The Space Interferometry Mission (SIM) requires fringe measurements to the level of picometers in order to produce astrometric data at the micro-arc-second level. To be more specific, it is necessary to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer to tens of picometers. The internal path is measured with a small heterodyne metrology beam, whereas the starlight fringe position is estimated with a CCD sampling a large concentric annular beam. One major challenge for SIM is to align the metrology beam with the starlight beam to keep the consistency between these two sensors at the system level while articulating the instrument optics over the field of regard. The Micro-Arcsecond Metrology testbed (MAM), developed at the Jet Propulsion Laboratory, features an optical interferometer with a white light source, all major optical components of a stellar interferometer and heterodyne metrology sensors. The setup is installed inside a large vacuum chamber in order to mitigate the atmospheric and thermal disturbances. Astrometric observations are simulated by articulating the optics over the 15 degrees field of regard to generate multiple artificial stars. Recent data show agreement between the metrology and starlight paths to 20pm in the narrow angle field and to 350pm in the full wide angle field of regard of SIM. This paper describes the MAM optical setup, the observation process, the current data and how the performance relates to SIM.

Catanzarite, Joseph H.↗

Progress in Interferometric Rayleigh Scattering to Measure Fluctuations Spectra of Velocity and Temperature in High Speed Flows

A new, spectrally-resolved, Rayleigh scattering setup at NASA Ames is further developed to measure fluctuations in velocity and temperature. Using a combination of a continuous-wave laser, a stabilized Fabry-Perot interferometer (FPI), an EMCCD camera, and a photo-multiplier tube, the setup was demonstrated to provide fairly accurate measurements of time-averaged velocity, temperature, density and spectrum of density fluctuations in a high-speed free jet (Panda & White, 2018). This paper describes further progress in fast measurement of the Rayleigh-Brillouin spectrum via a 16-anode linear-array of photo-multiplier tube and a multi-channel, photo-electron counter. Rayleigh scattered light from a 0.4mm long probe volume was directly imaged through the FPI and was imaged on the linear array. Synchronous photo-electron counting over a series of short, contiguous gates provided time-evolution of the fringes at a 10 kHz sampling rate. Sample spectra collected from a Mach 0.98 jet show spectral content floating on high noise-floor. Efforts to collect longer time series of data and different schemes of extracting velocity and temperature information are now in progress.

Panda, J.↗