Search NASA⌕ Search

SEARCH · Search NASA

Results for “WHITE NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Universal CMB 𝐵-mode spectrum from early causal tensor sources

Many early Universe scenarios predict postinflationary tensor perturbations from causality-limited, subhorizon sources. While the microphysical details may be different, as long as these sources are bounded in duration and correlation length, their tensor power spectra exhibit a universal scaling behavior at small wave number: 𝒫 ℎ ⁡(𝑘)∝𝑘 3 , corresponding to white noise on superhorizon scales at the time of production. If these early causal tensor sources (ECTs) exclusively produce gravitational waves before redshift 𝑧 ∼10 5 , this scaling is realized on all of the scales observed in the CMB, and thus yields a universal multipole distribution for the 𝐵-mode angular power spectrum. Unlike the scale-invariant distributions of inflationary 𝐵 modes, ECTs generically predict enhanced power on small scales and suppressed power on large scales, which allows these source classes to be distinguished given measurements over a sufficient range of angular scales. In this paper, we introduce a unified framework for characterizing ECTs and demonstrate how their universal infrared scaling manifests in low-frequency observables, including CMB 𝐵 modes and stochastic gravitational wave spectral densities. We illustrate this mapping with representative case studies of this universality class involving first-order phase transitions, topological defects, and enhanced scalar perturbations, which source tensor modes at second order in perturbation theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Earth-Centered, Earth-Fixed Inertial Navigation System & Error-State Kalman Filter Reference Manual

This is a self-contained reference document that derives the equations necessary to build a combined inertial navigation system and error-state Kalman filter. Coordinate transform, linear time invariant system, inertial sensing, and error-state Kalman filtering theory is built up from first principles. This theory is then leveraged to derive the system equations for two combined inertial navigation system and error-state Kalman filters: (1) a 15-state system modeling white-noise-integrating accelerometer and gyroscope biases, and (2) a 39-state system modeling static and first-order Gauss-Markov accelerometer and gyroscope biases, scale factor errors, and cross-axis sensitivity errors.

42 ENGINEERING↗

Testing the ΛCDM Cosmological Model with Forthcoming Measurements of the Cosmic Microwave Background with SPT-3G

We forecast constraints on cosmological parameters enabled by three surveys conducted with SPT-3G, the third-generation camera on the South Pole Telescope. The surveys cover separate regions of 1500, 2650, and 6000 deg$^{2}$ to different depths, in total observing 25% of the sky. These regions will be measured to white noise levels of roughly 2.5, 9, and 12μK-armin, respectively, in cosmic microwave background (CMB) temperature units at 150 GHz by the end of 2024. The survey also includes measurements at 95 and 220 GHz, which have noise levels a factor of ∼1.2 and 3.5 times higher than 150 GHz, respectively, with each band having a polarization noise level ∼2times higher than the temperature noise. We use a novel approach to obtain the covariance matrices for jointly and optimally estimated gravitational lensing potential band powers and unlensed CMB temperature and polarization band powers. We demonstrate the ability to test the ΛCDM model via the consistency of cosmological parameters constrained independently from SPT-3G and Planck data, and consider the improvement in constraints on ΛCDM extension parameters from a joint analysis of SPT-3G and Planck data. The ΛCDM cosmological parameters are typically constrained with uncertainties up to ∼2 times smaller with SPT-3G data, compared to Planck, with the two data sets measuring significantly different angular scales and polarization levels, providing additional tests of the standard cosmological model.

79 ASTRONOMY AND ASTROPHYSICS↗

SPT-3G D1: Maps of the millimeter-wave sky from 2019 and 2020 observations of the SPT-3G Main field

Maps of the sky in millimeter wavelengths contain rich information on cosmology through anisotropies of the cosmic microwave background (CMB). Creating multifrequency sky maps of anisotropies in the $I$, $Q$, and $U$ Stokes parameters is one of the first steps of CMB cosmology analyses. In this work, we describe the production and validation of a set of sky maps from the South Pole Telescope's third-generation camera, SPT-3G. The maps are from data taken in frequency bands centered at 95, 150, and 220 GHz and taken during the first two years, 2019 and 2020, of the SPT-3G Main survey, which covers $4\%$ of the sky. We applied high-pass filters to time series of individual detectors and binned the filtered time series samples into map pixels. After that, we calibrated and cleaned the maps to reduce known systematic errors. In addition, we searched for other systematic errors through null tests and mitigated a significant systematic error detected therein. The white noise levels of the full-depth maps of the $I$ Stokes parameter are $5.4$, $4.4$, and $16.2$$\mathrm{μK}$-$\mathrm{arcmin}$ in the 95, 150, and 220 GHz bands, respectively, and $8.4$, $6.6$, and $25.8$$\mathrm{μK}$-$\mathrm{arcmin}$ for $Q/U$. These maps are the deepest to date used for measurements of mid-to-high-$\ell$ primary temperature and $E$-mode polarization CMB anisotropies, and reconstructions of the CMB gravitational lensing potential. We make these maps and supporting data products publicly accessible.

Quan, W. [Argonne (main); Chicago U., EFI; Chicago↗

Galaxy Clusters Selected via the Sunyaev-Zel'dovich Effect in 5 year data from the SPT-3G Main Survey

We report a new galaxy cluster catalog, selected using the thermal Sunyaev-Zel'dovich (SZ) effect, from 5 years of observations of the SPT-3G Main field. Drawn from arcminute-resolution data with white noise levels of 3.2, 2.5, and 8.9 $μ$K-arcmin at 95, 150, and 220 GHz, respectively, the sample consists of 8,892 cluster candidates detected above significance $ξ=4$, with an expected purity of $>82\%$ (4,480 at $ξ\ge5$ with purity $>99\%$). Using optical and infrared data we have confirmed 7,190 candidates as clusters. The sample spans a mass range $7.9 \times 10^{13}M_\odot/h_{70}< M_\textrm{500c} < 1.6 \times 10^{15}M_\odot/h_{70}$ with a median mass of $1.65 \times 10^{14}M_\odot/h_{70}$, and a redshift range of $0.0371$ and 271 at $z>1.5$. Compared to previous SZ cluster samples from South Pole Telescope and Atacama Cosmology Telescope data, the SPT-3G sample is highly consistent in mass and redshift but is significantly deeper, with per-cluster detection signal-to-noise 2-4 times higher and a cluster density of 4.5 confirmed clusters/deg$^2$. We cross match with eRASS1 cluster and point source catalogs, finding 1,279 and 1,319 matches, respectively. The SPT and eROSITA cluster mass estimates are in relatively good agreement. We perform a series of validation checks using both internal data splits and comparisons to external samples. These tests show increasing correlated (dusty) emission with redshift, with a $\sim17\times$ larger 220 GHz temperature increment for clusters at $z\sim1.5$ than $z\sim0.25$, but only weak evidence for correlated synchrotron emission. Finally, a number of clusters are flagged as candidate strong gravitational lenses.

Bleem, L. E. [Argonne (main); Chicago U., KICP; Ch↗

Detecting Unclassified Electromagnetic Signals for Secure Wireless Communication Using Open Set Recognition

We developed multiple machine learning methods for the detection and classification of new wireless communication waveforms, which is critical for targeted attacks in wireless networks and electronic warfare. Our machine learning models are capable of dynamically detecting security threats in near real time through our advanced open set recognition (OSR) approach. This model has demonstrated significant improvements in the detection of unknown waveforms, thereby enhancing the security and reliability of mission critical communications. Our approach to detecting uncertain security threats is novel; we advanced OSR techniques by incorporating domain knowledge of wireless signals. Specifically, we combined time and frequency domain model features to enhance the model’s performance. Utilizing an OSR approach eliminates the need for training data to be distributed similarly to the deployment environment and removes the requirement for the training set to contains all possible threat classes. This is crucial because it is often infeasible to determine and characterize all potential security threats in advance. Our model were trained on simulated data, generated in partnership with the University at Albany, State of New York. The data set contained a diverse array of wireless signals, including those with additive white Gaussian noise and multipath signals, with and without line of sight. This comprehensive training set allowed us to optimize our models to detect unknown waveforms under various challenging scenarios, such as low signal-to-noise ratios. By training on various waveforms, varying signal-to-noise ratio, and different sample sizes under normal conditions, our models were fine tuned to perform effectively in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

Syncopated dynamical decoupling to suppress crosstalk in quantum circuits

Theoretically understanding and experimentally characterizing and modifying the underlying Hamiltonian of a quantum system is of utmost importance in achieving high-fidelity quantum gates for quantum computing. Here, in this work, we explore the use of dynamical decoupling (DD) in characterizing and suppressing undesired two-qubit couplings as well as the underlying single-qubit decoherence, both significant hurdles to achieving precise quantum control and realizing quantum computing on many hardware prototypes. Through discrete search of DD sequences, we identify sequences that protect against decoherence and selectively target unwanted two-qubit interactions of general form. On a transmon-qubit-based superconducting quantum device, we identify separate white and 1/𝑓 noise components underlying the single-qubit decoherence and a static ZZ coupling between pairs of qubits. A family of syncopated DD sequences is found and their efficiency is demonstrated in two-qubit benchmarking experiments. The syncopated decoupling technique significantly boosts performance in a realistic algorithmic quantum circuit.

97 MATHEMATICS AND COMPUTING↗

Patch2Self2: Self-supervised Denoising on Coresets via Matrix Sketching

Diffusion MRI (dMRI) non-invasively maps brain white matter yet necessitates denoising due to low signal-to-noise ratios. Patch2Self (P2S) employing self-supervised techniques and regression on a Casorati matrix effectively denoises dMRI images and has become the new de-facto standard in this field. P2S however is resource intensive both in terms of running time and memory usage as it uses all voxels (n) from all-but-one held-in volumes (d-1) to learn a linear mapping Phi : \mathbb R ^ n x(d-1) \mapsto \mathbb R ^ n for denoising the held-out volume. The increasing size and dimensionality of higher resolution dMRI acquisitions can make P2S infeasible for large-scale analyses. This work exploits the redundancy imposed by P2S to alleviate its performance issues and inspect regions that influence the noise disproportionately. Specifically this study makes a three-fold contribution: (1) We present Patch2Self2 (P2S2) a method that uses matrix sketching to perform self-supervised denoising. By solving a sub-problem on a smaller sub-space so called coreset we show how P2S2 can yield a significant speedup in training time while using less memory. (2) We present a theoretical analysis of P2S2 focusing on determining the optimal sketch size through rank estimation a key step in achieving a balance between denoising accuracy and computational efficiency. (3) We show how the so-called statistical leverage scores can be used to interpret the denoising of dMRI data a process that was traditionally treated as a black-box. Experimental results on both simulated and real data affirm that P2S2 maintains denoising quality while significantly enhancing speed and memory efficiency achieved by training on a reduced data subset.

Fadnavis, Shreyas↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

Statistical White-Line Analysis in High-Throughput TXM-XANES for Chemical State Quantification

The transmission X-ray microscopy (TXM) based X-ray absorption near-edge structure (XANES) technique provides three-dimensional mapping of element-specific chemical states at nanometer-scale spatial resolution and micrometer-scale fields of view. However, compared to conventional volume-averaged XANES (VA-XANES) measurements, the inherently small voxel size in TXM-XANES leads to a lower signal-to-noise ratio, making full-spectrum analysis computationally demanding and less robust. Here, we present the structural and compositional conditions for a statistical white-line analysis framework under which chemical state information can be directly extracted from the white-line peak position in voxel spectra without the need for voxel-wise background subtraction or normalization, under well-defined structural and compositional conditions. The method is validated on layered oxide cathode materials, where low-order polynomial fitting accurately reproduces white-line features, and the extracted energy distributions correlate strongly with VA-XANES results. This statistical approach enables high-throughput, dose-efficient, and noise-robust chemical state quantification in TXM-XANES, offering broad applicability to functional materials requiring nanoscale oxidation-state mapping.

TXM↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

The mass profiles of dwarf galaxies from Dark Energy Survey lensing

We present a novel approach to extracting dwarf galaxies from photometric data to measure their average halo mass profile with weak lensing. We characterize their stellar mass and redshift distributions with a spectroscopic calibration sample. By combining the ${\sim} 5000\,\mathrm{deg}^2$ multiband photometry from the Dark Energy Survey and redshifts from the Satellites Around Galactic Analogs Survey with an unsupervised machine learning method, we select a low-mass galaxy sample spanning redshifts $z\lt 0.3$ and divide it into three mass bins. From low to high median mass, the bins contain [146 420, 330 146, 275 028] galaxies and have median stellar masses of $\log _{10}(M_*/\text{M}_\odot)=\left[8.52\substack{+0.57 -0.76},\, 9.02\substack{+0.50 -0.64},\, 9.49\substack{+0.50 -0.58}\right]$ . We measure the stacked excess surface mass density profiles, $\Delta \Sigma (R)$, of these galaxies using galaxy–galaxy lensing with a signal-to-noise ratio of [14, 23, 28]. Through a simulation-based forward-modelling approach, we fit the measurements to constrain the stellar-to-halo mass relation and find the median halo mass of these samples to be $\log _{10}(M_{\rm halo}/\text{M}_\odot)$ = [$10.67\substack{+0.2 -0.4}$, $11.01\substack{+0.14 -0.27}$, $11.40\substack{+0.08 -0.15}$]. The cold dark matter profiles are consistent with NFW (Navarro, Frenk, and White) profiles over scales ${\lesssim} 0.15 \, {h}^{-1}$ Mpc. We find that ${\sim} 20$ per cent of the dwarf galaxy sample are satellites. This is the first measurement of the halo profiles and masses of such a comprehensive, low-mass galaxy sample. The techniques presented here pave the way for extracting and analysing even lower mass dwarf galaxies and for more finely splitting galaxies by their properties with future photometric and spectroscopic survey data.

dark matter↗

Cyclic Background Noise Variations on Infrasound Microbarometers From Micrometeorology and Human Activity

Infrasound microbarometers deployed on the Earth's surface capture pressure fluctuations and acoustic signatures, revealing trends in surface wind speed and cycles in ambient sound. Previous studies investigated wind noise trends at quarter day resolution and urban acoustic background variations on hourly to weekly scales. Cyclic variations at sub-hourly resolution over local distances remain unaddressed. We show that topography-driven micrometeorology impacts diurnal background noise levels below 10 Hz. Anthropogenic noise occurs over daily and weekly cycles, with inputs from traffic, ventilation systems, and power lines. These noise patterns vary at stations spaced less than a kilometer apart. We observe these phenomena by using a circular spectrogram to visualize frequency trends over a periodic temporal scale. This study demonstrates that infrasound microbarometer deployments can highlight localized wind patterns and time scales of human activity. The results suggest that future microbarometer deployments may benefit from site noise surveys before selecting final sensor locations.

Malach, Amrit Kaur [Sandia National Lab. (SNL-CA),↗