Search NASA⌕ Search

SEARCH · Search NASA

Results for “WIND TUNNEL WALL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigation of adaptive-wall wind tunnels with two measured interfaces

An adaptive wall wind tunnel with two measured interfaces has been studied using two interface static pressure measurements near the tunnel walls. An iterative procedure with static pressure measurements on two interfaces is described. The functional relationships of static pressure on two measured interfaces for the exterior region are presented. The convergence of the selected iterative procedure is proved analytically. The one-step convergence formulae are obtained and validated by the simulation of a numerical wind tunnel. Experimental investigation has been conducted with a two-dimensional airfoil model of NASA 0012 at a supercritical Mach number. The results have indicated that the selected procedure is feasible to speed up the flow convergence to the unconfined condition in applying the one-step convergence formulae.

Lo, C. F.↗

Wind tunnel wall interference

About a decade ago, interest in alleviating wind tunnel wall interference was renewed by advances in computational aerodynamics, concepts of adaptive test section walls, and plans for high Reynolds number transonic test facilities. Selection of NASA Langley cryogenic concept for the National Transonic Facility (NTF) tended to focus the renewed wall interference efforts. A brief overview and current status of some Langley sponsored transonic wind tunnel wall interference research are presented. Included are continuing efforts in basic wall flow studies, wall interference assessment/correction procedures, and adaptive wall technology.

Newman, Perry A.↗

Wind tunnel wall interference effects on a supercritical airfoil at transonic speeds

Wind tunnel tests of a 10% supercritical airfoil have been conducted in the Lockheed Compressible Flow Facility at transonic speeds to determine the effects of varying wind tunnel wall porosity on airfoil performance. Wall configurations ranging in porosity from 1.3% to 10% were investigated at Reynolds numbers of 7 to 30 million. Experimental data presented to show the effect of varying wall porosity include airfoil surface pressures, airfoil forces, and wind tunnel wall pressures. Utilizing the experimental results, an assessment of the applicability of current subcritical theoretical methods to predict wall interference corrections in subsonic and transonic flows is made.

Blackwell, J. A., Jr.↗

Computation of wind tunnel wall effects for complex models using a low-order panel method

A technique for determining wind tunnel wall effects for complex models using the low-order, three dimensional panel method PMARC (Panel Method Ames Research Center) has been developed. Initial validation of the technique was performed using lift-coefficient data in the linear lift range from tests of a large-scale STOVL fighter model in the National Full-Scale Aerodynamics Complex (NFAC) facility. The data from these tests served as an ideal database for validating the technique because the same model was tested in two wind tunnel test sections with widely different dimensions. The lift-coefficient data obtained for the same model configuration in the two test sections were different, indicating a significant influence of the presence of the tunnel walls and mounting hardware on the lift coefficient in at least one of the two test sections. The wind tunnel wall effects were computed using PMARC and then subtracted from the measured data to yield corrected lift-coefficient versus angle-of-attack curves. The corrected lift-coefficient curves from the two wind tunnel test sections matched very well. Detailed pressure distributions computed by PMARC on the wing lower surface helped identify the source of large strut interference effects in one of the wind tunnel test sections. Extension of the technique to analysis of wind tunnel wall effects on the lift coefficient in the nonlinear lift range and on drag coefficient will require the addition of boundary-layer and separated-flow models to PMARC.

Ashby, Dale L.↗

Modeling the effects of wind tunnel wall absorption on the acoustic radiation characteristics of propellers

Finite element theory is used to calculate the acoustic field of a propeller in a soft walled circular wind tunnel and to compare the radiation patterns to the same propeller in free space. Parametric solutions are present for a "Gutin" propeller for a variety of flow Mach numbers, admittance values at the wall, microphone position locations, and propeller to duct radius ratios. Wind tunnel boundary layer is not included in this analysis. For wall admittance nearly equal to the characteristic value of free space, the free field and ducted propeller models agree in pressure level and directionality. In addition, the need for experimentally mapping the acoustic field is discussed.

Baumeister, K. J.↗

Modeling the effects of wind tunnel wall absorption on the acoustic radiation characteristics of propellers

Finite element theory is used to calculate the acoustic field of a propeller in a soft walled circular wind tunnel and to compare the radiation patterns to the same propeller in free space. Parametric solutions are present for a 'Gutin' propeller for a variety of flow Mach numbers, admittance values at the wall, microphone position locations, and propeller to duct radius ratios. Wind tunnel boundary layer is not included in this analysis. For wall admittance nearly equal to the characteristic value of free space, the free field and ducted propeller models agree in pressure level and directionality. In addition, the need for experimentally mapping the acoustic field is discussed.

Baumeister, K. J.↗

Transonic wind-tunnel wall interference

A method for analyzing wall interference is described which avoids the assumption of linear superposition of perturbations in extracting the wall induced velocity field. Measurements of pressure distribution on or near the tunnel walls during the actual wind tunnel test, are imposed as boundary values to be matched. Instead of applying wall interference corrections to the wind tunnel data, some property of the wall is adjusted until a calculated interference free criterion is satisfied for each tunnel data point. The mode of operation for the National Transonic Facility, envisioned as a correctable interference transonic tunnel, combines the capability for accurate assessment of wall interference with a limited capability for wall control.

Kemp, W. B., Jr.↗

Residual interference and wind tunnel wall adaption

Measured flow variables near the test section boundaries, used to guide adjustments of the walls in adaptive wind tunnels, can also be used to quantify the residual interference. Because of a finite number of wall control devices (jacks, plenum compartments), the finite test section length, and the approximation character of adaptation algorithms, the unconfined flow conditions are not expected to be precisely attained even in the fully adapted stage. The procedures for the evaluation of residual wall interference are essentially the same as those used for assessing the correction in conventional, non-adaptive wind tunnels. Depending upon the number of flow variables utilized, one can speak of one- or two-variable methods; in two dimensions also of Schwarz- or Cauchy-type methods. The one-variable methods use the measured static pressure and normal velocity at the test section boundary, but do not require any model representation. This is clearly of an advantage for adaptive wall test section, which are often relatively small with respect to the test model, and for the variety of complex flows commonly encountered in wind tunnel testing. For test sections with flexible walls the normal component of velocity is given by the shape of the wall, adjusted for the displacement effect of its boundary layer. For ventilated test section walls it has to be measured by the Calspan pipes, laser Doppler velocimetry, or other appropriate techniques. The interface discontinuity method, also described, is a genuine residual interference assessment technique. It is specific to adaptive wall wind tunnels, where the computation results for the fictitious flow in the exterior of the test section are provided.

Mokry, Miroslav↗

Wind tunnel wall effects in a linear oscillating cascade

Experiments in a linear oscillating cascade reveal that the wind tunnel walls enclosing the airfoils have, in some cases, a detrimental effect on the oscillating cascade aerodynamics. In a subsonic flowfield, biconvex airfoils are driven simultaneously in harmonic, torsion-mode oscillations for a range of interblade phase angle values. It is found that the cascade dynamic periodicity - the airfoil to airfoil variation in unsteady surface pressure - is good for some values of interblade phase angle but poor for others. Correlation of the unsteady pressure data with oscillating flat plate cascade predictions is generally good for conditions where the periodicity is good and poor where the periodicity is poor. Calculations based upon linearized unsteady aerodynamic theory indicate that pressure waves reflected from the wind tunnel walls are responsible for the cases where there is poor periodicity and poor correlation with the predictions.

Buffum, D. H.↗

Wind tunnel wall effects in a linear oscillating cascade

Experiments in a linear oscillating cascade reveal that the wind tunnel walls enclosing the airfoils have, in some cases, a detrimental effect on the oscillating cascade aerodynamics. In a subsonic flow field, biconvex airfoils are driven simultaneously in harmonic, torsion-mode oscillations for a range of interblade phase angle values. It is found that the cascade dynamic periodicity - the airfoil to airfoil variation in unsteady surface pressure - is good for some values of interblade phase angle but poor for others. Correlation of the unsteady pressure data with oscillating flat plate cascade predictions is generally good for conditions where the periodicity is good and poor where the periodicity is poor. Calculations based upon linearized unsteady aerodynamic theory indicate that pressure waves reflected from the wind tunnel walls are responsible for the cases where there is poor periodicity and poor correlation with the predictions.

Buffum, Daniel H.↗

Experiments On Schemes For Adaptive-Wall Wind Tunnels

Report discusses experimental investigation of various convergence schemes for adaptive-wall wind tunnel. Results show side-wall-pressure measurements used as flow variables yield same unconfined-flow conditions as those obtained by measuring streamwise and perpendicular components of velocity with laser Doppler velocimeter. Justifies use of influence coefficients in one-step and iterative convergence schemes. Also shows with one-step convergence scheme, satisfactory adaptation obtained when number of iterations reduced to one (or sometimes two).

Celik, Z. Z.↗

Computational study of wind-tunnel wall effects on flow field around delta wings

This paper addresses wind-tunnel wall effects on delta-wing flow fields using the Free Vortex Sheet (FVS) theory in support of planned subsonic wind-tunnel tests. The configurations include several sizes of a 65-deg delta wing in the NASA Langley Research Center Low-Turbulence Pressure Tunnel (LTPT), and an aspect ratio 1 delta wing in the Delft University low-speed tunnel. Standard upflow correction methodology is extended to account for angle-of-attack and nonplanar effects. Blockage and streamline curvature corrections are not applied in the present investigation. Resulting corrections to the 65-deg delta flow field were good for model-to-tunnel span ratios up to 0.5 and angles of attack up to 30-deg, both for linear attached flow and nonlinear vortex flow. For the aspect ratio 1 delta wing, corrections to the vortex flow field for the effect of the averaged upflow angle were satisfactory but streamline curvature effects were larger.

Frink, Neal T.↗

Higher-order flow angle corrections for three-dimensional wind tunnel wall interference

A second-order theory including camber effects in wind tunnel wall interference corrections is described. Changes in the geometrical configuration of the model tested are avoided by introducing the camber correction as an equivalent angle-of-attack correction. Tabular and graphic data are presented which indicate improved accuracy for second-order over first-order theory.

Rizk, M. H.↗

Adaptive-Wall Wind Tunnel

Side vents controlled automatically to compensate for interference by walls. Improved test station for 2- by 2-Foot Adaptive-Wall Wind Tunnel at Ames Research Center equipped for automatic sensing and correction of effects of walls on airflow in vicinity of test model. New facility well suited for advanced research and development. Velocities measured along lines near model used to calculate velocities observed along lines farther from model if model were in free air. Calculated values compared with velocities measured along farther lines.

Morgan, Daniel G.↗

Investigation of transonic flow over segmented slotted wind tunnel wall with mass transfer

The flowfield on a segmented multi-slotted wind tunnel wall was studied at transonic speeds by measurements in and near the wall layer using five port cone probes. The slotted wall flowfield was observed to be three-dimensional in nature for a relatively significant distance above the slot. The boundary layer characteristics measured on the single slotted wall were found to be very sensitive to the applied suction through the slot. The perturbation in the velocity components generated due to the flow through the slot decay rapidly in the transverse direction. A vortex-like flow existed on the single slotted wall for natural ventilation but diminished with increased suction flow rate. For flow on a segmented multi-slotted wall, the normal velocity component changes were found to be maximum for measurement points located between the segmented slots atop the active chamber. The lateral influence due to applied suction and blowing, through a compartment, exceeded only slightly that in the downstream direction. Limited upstream influence was observed. Influence coefficients were determined from the data in the least-square sense for blowing and suction applied through one and two compartments. This was found to be an adequate determination of the influence coefficients for the range of mass flows considered.

Bhat, M. K.↗