Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wastewater System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Method Development for In Situ Microbiome Profiling of the Water Recovery System’s Wastewater Tank Onboard the International Space Station

A distinctive microbial community has inhabited the International Space Station (ISS) Water Recovery System (WRS) for over 14 years and has experienced the stressors associated with the microgravity environment. The WRS generates potable water for the crew from urine distillate, humidity condensate, Sabatier product water, and the occasional off-loading of ground-supplied water (1). The reservoir for these products, the wastewater tank, does not have a means of microbial control. Current in situ microbial monitoring of the WRS is limited to quarterly culture-based assessments of the potable water product using a microbial capture device and coliform detection bag. Additional analysis of the wastewater and condensate sources are collected into Teflon bags for analysis following return to the ground. The time between sample collection and the return to Earth, as well as the lack of preservation, results in a skewed depiction of the microbiome. Routinely observed from these returned wastewater samples are high counts (105 – 106 colony forming units per mL) and two prevailing genera, Ralstonia and Cupriavidus, as well as a high abundance of unidentified organisms (Table 1). The wastewater tank likely contains a more diverse microbiome, as a higher diversity of bacteria and fungi has been noted upstream and downstream of the tank.

Sarah Stahl-Rommel↗

Electrochemical testing of metals for petroleum wastewater monitoring

The purpose of this project was to determine the feasibility of ion-selective electrode (ISE) as compared to x-ray fluorescence (XRF) for determining the concentrations of metal ions in petroleum wastewater. ISEs for silver and cadmium were tested in a laboratory under increasingly realistic conditions, then deployed in the sewer wastewater monitoring complex to simulate a petroleum wastewater system. By verifying the ISE calibration after wastewater exposure and comparing its measurements to the XRF systems within the wastewater monitoring system, we determined that the ISE is more sensitive but less feasible for use in live wastewater monitoring due to fouling concerns.

Energy - Petroleum↗

Hollow Fiber Membrane Bioreactor Systems for Wastewater Processing: Effects of Environmental Stresses Including Dormancy Cycling and Antibiotic Dosing

Membrane-aerated biofilm reactors (MABRs) have been studied for a number of years as an alternate approach for treating wastewater streams during space exploration. While the technology provides a promising pre-treatment for lowering organic carbon and nitrogen content without the need for harsh stabilization chemicals, several challenges must be addressed before adoption of the technology in future missions. One challenge is the transportation of bioreactors containing intact, active biofilms as a means for rapid start-up on the International Space Station or beyond. Similarly, there could be a need for placing these biological systems into a dormant state for extended periods when the system is not in use, along with the ability for rapid restart. Previous studies indicated that there was little influence of storage condition (4 or 25 C, with or without bulk fluid) on recovery of bioreactors with immature biofilms (48 days old), but that an extensive recovery time was required (20+ days). Bioreactors with fully established biofilms (13 months) were able to recover from a 7-month dormancy within 4 days (approximately 1 residence). Further dormancy and recovery testing is presented here that examines the role of biofilm age on recovery requirements, repeated dormancy cycle capabilities, and effects of long-duration dormancy cycles (8-9 months) on HFMB systems. Another challenge that must be addressed is the possibility of antibiotics entering the wastewater stream. Currently, for most laboratory tests of biological water processors, donors providing urine may not contribute to the study when taking antibiotics because the effects on the system are yet uncharacterized. A simulated urinary tract infection event, where an opportunistic, pathogenic organism, E. coli, was introduced to the HFMBs followed by dosing with an antibiotic, ciprofloxacin, was completed to study the effect of the antibiotic on reactor performance and to also examine the development of antibiotic-resistant communities within the system.

Bioreactor Systems↗

A Preliminary Modeling Study of Biofilm Accumulation in the Water Recovery System

Bacterial biofilms are ubiquitous in wastewater systems on earth and in spacecraft, such as in the International Space Station (ISS) wastewater processing assembly (WPA), where they cause problems in the tank, solenoid valves, and pipelines. Downstream filter applications, tank cycling, and regular biocide water flushing have been used to control biofilm accumulation on board the ISS. Biofilm control is expected to be a challenge for long-term missions with a dormancy period of up to a year, as stagnant water systems are highly susceptible to biofilm growth. Flushing of the system with biocidal water has been proposed to avoid biomass problems for long-term missions. To validate the proposed flush method, a mathematical model, based on the metabolism maintenance rate of bacteria, is being developed to understand the current biofilm accumulation rate in the ISS WPA system and to calculate the biomass production rate under dormancy-like conditions. This method of quantification of biofilm can be applied as a function of nutrient inputs to guide the selection and optimization of biofilm mitigation approaches. The method can also be helpful in understanding, defining, quantifying, visualizing, and simulating the state of the water processing system during operation and after dormancy.

Angie M Diaz↗

Energy from aquatic plant wastewater treatment systems

Water hyacinth (Eichhornia crassipes), duckweed (Spirodela sp. and Lemma sp.), water pennywort (Hydrocotyle ranunculoides), and kudzu (Pueraria lobata) were anaerobically fermented using an anaerobic filter technique that reduced the total digestion time from 90 days to an average of 23 days and produced 0.14-0.28 cu m CH4/kg (dry weight) (2.3-4.5 cu ft/lb) from mature filters. The anaerobic filter provided a large surface area for the anaerobic bacteria to establish and maintain an optimum balance of facultative, acid-forming, and methane-producing bacteria. Consequently the efficiency of the process was greatly improved over prior batch fermentations.

Wolverton, B. C.↗

Assessing Energy Infrastructure Devices for Vulnerabilities

Industrial control systems prove to be vital to the health and security of the nation in our critical infrastructure. Critical infrastructure includes the most foundational systems to support modern civilization which includes water and wastewater systems, communications, and the electricity we use to name a few sectors. However, these devices' overall composition remains largely unknown and are untested from a cyber security perspective. As part of the Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, I analyzed one such energy infrastructure device to better understand how it functions, what hardware and software components are present within it, and assess it for security vulnerabilities. To achieve this, I reverse engineered binary files using Ghidra to understand system functionality and learned more about how to collaborate with other researchers on a shared Ghidra project. I learned more about how web sockets function and how to interact with them through Python to test if they are secure or not. This work led me to assess possible vulnerabilities in this device and provide a better understanding of its composition and function, which are essential to INL's mission of securing our nation's energy infrastructure.

99 - GENERAL AND MISCELLANEOUS↗

Wastewater reuse benefits for municipal complete retention lagoons: Life cycle assessment and dynamic modeling

Complete retention lagoons with wastewater reuse for agricultural purposes may offer sustainability advantages over alternative systems for small communities in semiarid regions. This study quantifies the environmental life cycle impact of adopting agriculture water reuse systems using case study data to estimate operating and building infrastructure impacts and spatial–temporal modeling to quantify resource trade-offs. Water reuse system benefits are highly dependent on supply–storage–demand dynamics. The relative size of irrigated agricultural land to the lagoon size was the most significant factor influencing site water application rates. The benefits are sensitive to changes in air emissions occurring from the agricultural land and further emphasize the importance of proper fertilizer management when adopting water reuse systems. Wastewater reuse from complete retention lagoons reduce life cycle GHG emissions, primarily through excavation reductions, offset fertilizer use, and especially from increased crop yields from wastewater reuse at previously rainfed sites.

54 ENVIRONMENTAL SCIENCES↗

Data-driven Community-centered Resilient Assessment and Planning Toolkit for Nexus of Energy and Water (DCRAPT-NEW)

Urban areas, including Detroit and Pittsburgh, have suffered significant dual outages of the electrical and water infrastructure in the past decade due, in part, to the increasing number of extreme weather events. With increasing temperatures and rainfall intensity, these regions need to prepare for increasing extreme events through community-based energy and water resilience analysis, planning, and enhancement. This project developed a suite of open-source, open-access, community-centered, data-driven assessment and distributed energy resource (DER) and planning tools for energy and water resilience enhancement in urban areas. Through establishing a multi-level community awareness and engagement mechanism and a comprehensive collection of power outage and flooding data, an innovative group of community energy and water resilience assessment and planning tools have been developed for a wide range of users with differing and variable sets of data available to them. The developed tools include (1) DOE EAGLE-I data-driven, deep-learning assisted resilience assessment and DER planning tools at the county level with socioeconomic factors incorporated; (2) Utility annual power outage data-driven tools for long term resilience assessment and DER planning and 15-min power outage data-driven tools for short term resilience assessment and planning; (3) Detailed engineering tools for energy and water systems resilience assessment and planning when the system topology and component fragility curves are available; (4) Alternative Resiliency Metric Calculation that extracts and separates outage and restoration processes; and (5) Co-optimization tools that evaluate the resilience of the power and sewage system and allow users to conduct joint planning with energy and wastewater systems. The developed tools provide planners, decision-makers, and stakeholders with powerful capabilities to systematically evaluate system/community resilience and optimal and actionable guidance for enhancing resilience while prioritizing DER investments. The tools have been used and validated in Detroit and Pittsburgh and can be used in other areas of the nation. In addition, this project will (1) advance the knowledge and applications of machine-learning methods in analyzing and fusing different layers of information and generating meaningful data points such as generating rare weather events; (2) significantly improve the energy and water resilience of the identified communities in Detroit and Pittsburgh and prepare for more frequent and severe weather conditions; (3) help communities assess extreme weather event impacts and address short-term and long-term resilience-related issues The developed tools have been made public via GitHub and demonstrated to community stakeholders and utility companies via the two annual workshops and numerous community engagement meetings. The project outcomes are also disseminated through publications in various journals and conference proceedings, and presentations at top conferences.

13 HYDRO ENERGY↗

Water System Architectures for Moon and Mars Bases

Water systems for human bases on the moon and Mars will recycle multiple sources of wastewater. Systems for both the moon and Mars will also store water to support and backup the recycling system. Most water system requirements, such as number of crew, quantity and quality of water supply, presence of gravity, and surface mission duration of 6 or 18 months, will be similar for the moon and Mars. If the water system fails, a crew on the moon can quickly receive spare parts and supplies or return to Earth, but a crew on Mars cannot. A recycling system on the moon can have a reasonable reliability goal, such as only one unrecoverable failure every five years, if there is enough stored water to allow time for attempted repairs and for the crew to return if repair fails. The water system that has been developed and successfully operated on the International Space Station (ISS) could be used on a moon base. To achieve the same high level of crew safety on Mars without an escape option, either the recycling system must have much higher reliability or enough water must be stored to allow the crew to survive the full duration of the Mars surface mission. A three loop water system architecture that separately recycles condensate, wash water, and urine and flush can improve reliability and reduce cost for a Mars base.

moon base↗

Shuttle Wastewater Solution Characterization

During the 31st shuttle mission to the International Space Station, STS-129, there was a clogging event in the shuttle wastewater tank. A routine wastewater dump was performed during the mission and before the dump was completed, degraded flow was observed. In order to complete the wastewater dump, flow had to be rerouted around the dump filter. As a result, a basic chemical and microbial investigation was performed to understand the shuttle wastewater system and perform mitigation tasks to prevent another blockage. Testing continued on the remaining shuttle flights wastewater and wastewater tank cleaning solutions. The results of the analyses and the effect of the mitigation steps are detailed in this paper.

Adam, Niklas↗

A modeling pipeline to relate municipal wastewater surveillance and regional public health data

As COVID-19 becomes endemic, public health departments require improved passive indicators, which are independent of voluntary testing data, to estimate the prevalence of COVID-19 in local communities. Quantification of SARS-CoV-2 RNA from wastewater has the potential to be a powerful passive indicator. However, connecting measured SARS-CoV-2 RNA to community prevalence is challenging. We have developed a generalized methodology to improve the predictive power of wastewater measurements and applied it to data collected from treatment plants in the Chicago area. We built and compared a set of multi-linear regression models, which incorporate pepper mild mottle virus (PMMoV) as a population biomarker, Bovine coronavirus (BCoV) as a recovery control, and wastewater system flow rate into a corrected estimate for SARS-CoV-2 RNA concentration. For our data, models with BCoV performed better than those with PMMoV, but all model estimates of prevalence significantly improved correlation compared to doing no correction. We also investigate the utility of RNA measurements in wastewater as a leading indicator of COVID-19 trends. We do this in a rolling manner for corrected wastewater data and for other prevalence indicators, and statistically compare the temporal relationship between new increases in the wastewater data and those in other prevalence indicators. We find that wastewater trends often lead other COVID-19 indicators in predicting new surges.

60 APPLIED LIFE SCIENCES↗

Implementation of an ICS Ransomware Testbed: Scenarios, Variants, and Evaluation Methods

Ransomware attacks on Industrial Control Systems (ICS) have emerged as a formidable threat to the United States’ critical infrastructure, eliciting grave concerns regarding national security. In March 2023, the FBI Internet Crime Complaint Center (IC3) unveiled its 2022 Internet Crime Report, highlighting a concerning 870 complaints related to ransomware impacting U.S. critical infrastructure. Of the country's 16 critical infrastructure sectors, 14 encountered at least one ransomware attack. Notably, while the Healthcare and Public Health sector suffered the most, reporting 210 attacks, sectors pivotal to ICS networks and governmental organizations were also targeted: the Defense Industrial Base reported 1 attack, Water and Wastewater Systems 3, Chemical 19, Energy 15, Government Facilities 115, and Critical Manufacturing 157. For instance, a ransomware attack on a major chemical company could jeopardize not only its production but also pose environmental risks should systems controlling hazardous materials be compromised. In 2022, three ransomware variants predominantly targeted U.S. critical infrastructure: HIVE, with 87 attacks; ALPHV/BlackCat, with 114; and LOCKBIT, with 149. Several cyber-attacks, such as the MOVEit data breach in May 2023 and the Colonial Pipeline ransomware attack in May 2021, have been so impactful that they commanded national attention. The DarkSide hacking group's assault on the Colonial Pipeline, initiated on May 6th, 2021, stands as one of the most substantial and publicly acknowledged cyber-attacks against U.S. critical infrastructure. The group exploited an exposed Virtual Private Network (VPN) password, paving the way for initial intrusion and subsequent data theft. A mere day later, DarkSide unleashed a ransomware attack that compromised vital accounting and billing systems, prompting an immediate shutdown of the pipeline to mitigate further ransomware proliferation across its network. This crisis spurred a robust response from the U.S. president and regulators, culminating in a national emergency declaration related to the pipeline shutdown on May 9th, 2021. This incident mirrors the 2017 NotPetya ransomware attack that significantly impacted the shipping giant Maersk, highlighting an urgent need for fortified cybersecurity across various industries. Future incidents, akin to the Colonial Pipeline attack, could potentially be mitigated—or entirely averted—should government agencies and private entities scrutinize system vulnerabilities, exploring various ransomware types and entry points. Proactive measures, such as conducting experiments on VPN accounts or auditing passwords to pinpoint duplicate usage across diverse systems and software, might illuminate feasible entry points and vulnerability zones within an organization's systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bacteria Provide Cleanup of Oil Spills, Wastewater

Through Small Business Innovation Research (SBIR) contracts with Marshall Space Flight Center, Micro-Bac International Inc., of Round Rock, Texas, developed a phototrophic cell for water purification in space. Inside the cell: millions of photosynthetic bacteria. Micro-Bac proceeded to commercialize the bacterial formulation it developed for the SBIR project. The formulation is now used for the remediation of wastewater systems and waste from livestock farms and food manufacturers. Strains of the SBIR-derived bacteria also feature in microbial solutions that treat environmentally damaging oil spills, such as that resulting from the catastrophic 2010 Deepwater Horizon oil rig explosion in the Gulf of Mexico.

Source record↗

Water Security: Trends, Capabilities, and Research Directions to Secure Water Infrastructure

Water and wastewater sector is target rich and resource poor ~153k water utilities, serve 80% of US population ~16k publicly-owned wastewater systems in the US serve 75% of the population Need scalable solutions to fit small and medium to large systems Federal attention to critical infrastructure continues to grow – particularly in the water sector Increase in water sector incidents and threats for large scale disruption – particularly by nation-state actors and their proxies EPA is the SRMA DHS CISA focuses on critical infrastructure protection across sectors They must work together to secure WWW systems Research capabilities to enable secure water systems Current and future threats Resilience – natural disasters, accidents, cyber-physical attacks

99 - GENERAL AND MISCELLANEOUS↗

Characterization and Stimulation of Selenium Reducing Microbial Consortia from Real Flue Gas Desulfurization Wastewater Biological Treatment System

Selenium is released into the environment via anthropogenic activities such as coal combustion. The U.S. Environmental Protection Agency’s Effluent Limitation Guideline (ELG) Rule limits the release of selenium species into U.S. waterways. To meet the ELG limit for selenium, coal-fired power plants must treat the wastewater produced by the flue gas desulfurization (FGD) systems. Selenium removal is of interest because small changes of the concentrations of selenium in the environment can cause detrimental ecological consequences. Biological treatment is used to remediate this wastewater, but little is known about the individual species in the microbial consortium that reduce toxic water-soluble selenium oxyanions to insoluble elemental selenium. To optimize current biological treatment capabilities of this water, the selenium-reducing capabilities must be leveraged. In order to do so, the selenium-reducing bacteria (SeRB) in biological treatment systems must be characterized. This study will be the first to characterize the microbial consortia from a real FGD WW biological treatment system and provide insights on how to better achieve selenium removal via biological treatment. This work will provide insights into the microorganisms predominantly responsible for the reduction of selenium oxyanions in FGD wastewater biological treatment systems, which can be used to better optimize more efficient biological treatment strategies of this industrial waste.

geomicrobiology↗