Search NASA⌕ Search

SEARCH · Search NASA

Results for “Water Recovery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities

Improvements in process monitoring and control at water resource recovery facilities (WRRFs) could result in reductions in electricity consumption, chemical inputs, and greenhouse gas emissions, as well as improved energy recovery. Many current WRRF data collection, monitoring, and control approaches use 20th century process monitoring and control systems, which require large design safety factors to ensure reliability in the absence of more advanced, precise controls. Implementation of more modern data-driven control tools could lead to more efficient operations that provide intrinsic reliability with better overall process performance at full-scale. This project (1) developed and demonstrated data-driven process controls at full-scale facilities for five promising WRRF process technologies that provide whole-plant approaches and offer substantial energy and resource recovery benefits, and (2) created a Machine Learning (ML) Toolkit and an implementation guide of new process control approaches that walks users through each step of the ML workflow and illustrates the steps through case study examples.

54 ENVIRONMENTAL SCIENCES↗

Energy Efficient Waste Heat Coupled Forward Osmosis for Effluent Water Management at Coal-Fired Power Plants

This project sought to evaluate the technical and economic viability of the Aquapod©, a transformational low energy (<200 kJ/kg water) waste heat coupled forward osmosis (FO) technology, to manage effluents, meet cooling water demands, and achieve water conservation in a coal-fired power plant environment. The Aquapod© process is innovative because it is heat-driven, avoids the evaporation of water, and uses no toxic chemicals such as ammonia or amines. The Aquapod© process accomplishes this using an aqueous two-phase system (ATPS) coupled FO process. The evaluation revealed that the Aquapod© process offers a pathway to exploit waste heat resources within a power plant to achieve flue-gas desulfurization (FGD) wastewater volume reduction and water recovery with minimal pretreatment. Water recovery of 80% from FGD wastewater was achieved with minimal pretreatment, exceeding the project target of 50%. The estimated electrical energy of 2.16 kWh/m 3 of water produced for the Aquapod© process met the project target of < 3.6 kWh/m 3 . The heat required for the process operation was approximately 186 kJ/kg of produced water, which was slightly lower than the project target of 200 kJ/kg. The estimated treatment cost for installing and operating the Aquapod© process in conjunction with a spray dryer evaporator to achieve zero-liquid discharge (ZLD) of the 100 gpm FGD wastewater was $13.24/m 3 over a 30-year lifetime. As a point of reference, this study’s host power plant currently incurs a cost of $3.70/m 3 – $8.87/m3 on a discharged volume basis to discharge its wastewater into the publicly owned treatment works (POTW) after physical-chemical treatment. Therefore, the Illinois power plant would incur an incremental cost increase of $4.37/m 3 – 9.54/m 3 to achieve ZLD using the Aquapod© and spray dryer combination. Ample opportunities exist to further lower the ZLD capital and operating costs in the next design iteration to attain pipe parity at the higher end of the site treatment costs.

01 COAL, LIGNITE, AND PEAT↗

An Alternating, Current-Induced Electromagnetic Field for Membrane Fouling and Scaling Control during Desalination of Secondary Effluent from Municipal Wastewater

Membrane treatment of secondary effluent for reuse applications is a promising approach to expand water supplies and provide flexibility to water resources management. However, effective control of membrane fouling and scaling is crucial for cost-effective treatment and system resilience. This study compared the performance of antiscalants to an alternating, current-induced electromagnetic field (EMF) as an alternative pretreatment method to reverse osmosis. Compared to the no-EMF control experiments, the EMF device resulted in 13% higher water recovery and 366% lower flux decline at 60% of water recovery, along with 2–8 times lower precipitation of fouling and scaling, as evidenced by scanning electron microscope, energy dispersive X-ray spectroscopy, and chemical extraction analysis. The combination of the EMF with antiscalant was more effective for reducing membrane fouling and scaling, increasing water recoveries up to 89.3%, as compared to the EMF (67.5%) and antiscalant-only (73.6%) configurations. This is the first study to demonstrate synergistic effects of using an EMF in combination with antiscalants and could lead to lower pretreatment costs. Additional research is required to quantify the economics of this approach and to fully understand the fundamental mechanisms governing fouling and scaling control by an EMF.

42 ENGINEERING↗

Analysis of backwash settings to maximize net water production in an engineering-scale ultrafiltration system for water reuse

Ultrafiltration (UF) has been widely utilized as water pretreatment for different applications especially in water reuse. The UF system operation is characterized by a filtration phase, where particles accumulate on the membrane surface resulting in an increase in the transmembrane pressure (TMP) and a cleaning phase, where foulants are removed through cleaning cycles including physical backwash and chemical-enhanced backwash (CEB). In this study, data from an engineering-scale UF system treating reclaimed wastewater were used to assess the impact of backwashing on the filtration process. TMP backwash trigger, backwash duration, and CEB frequency were purposely varied for a cycle-by-cycle investigation on the net water production, water recovery, initial operating TMP, and filtration cycle duration. As the TMP backwash trigger was varied between 62 and 145kPa, the maximum net water production (63 m 3 /d) was achieved at 103kPa and water recovery remained relatively constant at approximately 92%. Backwash durations of 45, 65, and 85s were performed where both net water production and water recovery yielded similar results (~63 m 3 /d and ~ 91%) compared with 103kPa TMP backwash trigger. The CEB frequency was also lowered from one every three backwashes (1/3) to 1/6 and 1/12 and resulted in decreased net water production and water recovery while the initial TMP increased. Interestingly, the total number of CEBs remained approximately constant regardless of their frequency. In conclusion, results suggest that CEB is an important fouling control process to maximize water production.

42 ENGINEERING↗

Evaluating Pretreatment Strategies with Modeling for Reducing Scaling Potential of Reverse Osmosis Concentrate: Insights from Ion Exchange and Activated Alumina

Reverse osmosis concentrate (ROC) treatment is critical for enhancing water recovery and minimizing concentrate volume for disposal, especially in regions facing water scarcity. This study investigates the application of ion exchange (IX) resins and activated alumina (AA) as pretreatment strategies to mitigate scaling in ROC due to high concentrations of total dissolved solids, hardness (Ca 2+ and Mg 2+ ), and silica. Through a series of Langmuir isotherms, continuous column experiments, and model simulation, two types of strong acid cation IX resins and three types of strong base anion IX resins alongside three types of AA were evaluated. Results indicate that AA exhibits superior performance in silica removal, achieving up to a 65% reduction and maintaining performance for up to 800 bed volume without reaching saturation. Model simulation of a secondary reverse osmosis treating ROC after the IX and AA pretreatment indicated an additional water recovery of ~70% using antiscalants. This study demonstrates the potential for achieving higher water recovery while also identifying opportunities for pretreatment improvement. Challenges such as the limited IX capacity treating ROC, which requires frequent regeneration and increases operational costs, along with the restricted regeneration capacity of AA, underscore the importance of innovation. These findings emphasize the critical need for developing advanced materials and optimized strategies to further enhance the efficiency of ROC treatment processes.

activated alumina↗

Transforming Aeration Energy in Water Resource Recovery Facilities (WRRFs) through Suboxic Nitrogen Removal (Final Report)

The objective of this project was to advance two key technological components—aeration control strategies and process design methodologies—to support the development and broader adoption of suboxic biological nitrogen removal (SBNR). The project focused on achieving the following three goals: • Enhance Model Predictive Control (MPC) Technology: Advance the DO/Nmaster MPC platform from its initial 2018 pilot deployment at the Chico Water Resource Recovery Facility in California to full-scale integration. This included partnering with a blower technology commercialization partner and incorporating machine learning (ML) capabilities to enable nationwide deployment. • Bridge Knowledge Gaps in SBNR Process Design: Address fundamental gaps in SBNR process understanding through controlled pilot-scale testing at a dedicated pilot facility. These efforts supported the development of robust kinetic models to inform reliable SBNR control, operational strategies, and design frameworks. • Demonstrate Full-Scale Implementation of Low DO/SBNR with ML: Transition low dissolved oxygen (DO)/SBNR coupled with ML from pilot-scale trials to full-scale demonstration in flow-through biological nutrient removal (BNR) systems, with the goal of enabling scalable, nationwide adoption in activated sludge treatment processes. The project included demonstration of SBNR at the pilot scale as performed by Hampton Roads Sanitation District (HRSD) and at the full-scale as performed by the Los Angeles County Sanitation Districts' (LACSD) Pomona Water Reclamation Plant (POWRP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design considerations for a Digital Twin built to improve nitrification performance at a water resource recovery facility

A Digital Twin built around Activated Sludge Model No. 1 was deployed at a full-scale water resource recovery facility. Its design included a waste rate recommender system based on automatic scenario analyses, where influent loads and waste rates are varied to determine their impact on nitrification. At the same frequency as these scenario analyses, scheduled auto-calibrations allow for nitrifier maximum specific growth rate (μmax-NITO) soft sensing, the only kinetic parameter shown to require adjustment if the objective is aeration tank effluent ammonia forecasting accuracy. By integrating temperature forecasting over the next three sludge ages, this Digital Twin approach creates opportunities for advancing waste rate decisions in anticipation of seasonal temperature changes, optimizing ammonia control authority under varying influent loads, and furnishing valuable insights for future capital projects requiring nitrifier kinetic understanding and modelling.

54 ENVIRONMENTAL SCIENCES↗

Feedforward-feedback ammonia control at a water resource recovery facility based on a digital twin with hybrid model

Ammonia-based aeration control (ABAC) at full-scale Water Resource Recovery Facilities (WRRFs) can be challenged by diurnal loading and transport delays. This work addressed these challenges using a hybrid feedforward–feedback controller built on Activated Sludge Model 1 (ASM1), marking the first full-scale deployment to pair a mechanistic feedforward core with data-driven corrections. The objectives were to improve ammonia setpoint tracking, assess performance of the mechanistic model when enhanced with data-driven corrections, and document full-scale operation. The hybrid model incorporates two data-driven components: (1) a Mechanistic Error Forecasting Engine (MEFE), consisting of a multivariate linear regressor and a long short-term memory (LSTM) ensemble. Defying expectations, low-parameter models outperformed more complex alternatives, reducing the mechanistic error by 71%. (2) A Residual Oscillation Forecasting Engine (ROFE), based on Fast Fourier Transform, reduced the remaining error by another 35%. Two proportional–integral (PI) feedback loops further (i) trim the feedforward output and (ii) eliminate residual controller error in the final aerobic zone. In full-scale operation, the controller reduced mean-squared error (MSE) by 94% over the baseline and produced more stable dissolved oxygen (DO) setpoints. Overall, it was proven that layering multi-timescale data-driven models on a mechanistic core can yield reliable ABAC performance at WRRFs.

54 ENVIRONMENTAL SCIENCES↗

Component innovations for lower cost mechanical vapor compression

Despite significant capital and operating costs, mechanical vapor compression (MVC) remains the preferred technology for challenging brine concentration applications. Here, this work seeks to assess the dependence of MVC costs on feedwater salinity and desired water recovery and to quantify the value of improved component performance or reduced component costs for reducing the levelized cost of water (LCOW) of MVC. We built a cost optimization model coupling thermophysical, heat and mass transfer, and technoeconomic models to optimize and identify low cost MVC system designs as a function of feedwater salinity and water recovery. The LCOW ranges over 3.6 to 6.1 $\$$/m 3 for seawater feed salinities of 25–150 g/kg and water recoveries of 40–80 %. We then perform sensitivity analysis on parameter inputs to isolate irreducible costs and determine high value component innovation targets. The LCOW was most sensitive to evaporator material costs and performance, including the overall heat transfer coefficient in the evaporator. Process and material innovations such as polymer-composite evaporator tubes that reduce evaporator costs by 25 % without reducing heat transfer performance by more than 10 % would result in MVC cost reductions of 8 %.

42 ENGINEERING↗

Superstructure Optimization for Brine Valorization from Brackish Water Desalination

This poster presents preliminary results from a superstructure optimization framework developed to identify cost-optimal brine valorization configurations for brackish water desalination plants across diverse U.S. regional feed chemistries. The study uses brackish groundwater compositions from Arizona, California, Florida, New Mexico, and Texas. Using Pyomo Generalized Disjunctive Programming (GDP) within the WaterTAP modeling environment, the optimization framework simultaneously evaluates thousands of candidate treatment configurations, spanning nanofiltration, reverse osmosis, and chemical precipitation, to minimize the levelized cost of water (LCOW) while meeting water recovery targets and product recovery constraints. Results across eight representative feed clusters demonstrate water recovery rates of 57–87% and net LCOW values ranging from -$0.032/m³ (net revenue-positive) to $0.80/m. Notably, no single process configuration was optimal across all feed types, underscoring the necessity of feed-specific optimization. Products targeted include calcium carbonate (CaCO₃) at $0.01/kg and sodium chloride (NaCl) at $0.10/kg, both at 95% purity, with product revenues offsetting treatment costs in several scenarios. The work advances NAWI's process systems engineering capabilities for multi-configuration screening.

58 GEOSCIENCES↗

Dissolved gas recovery from water using a sidestream hollow-fiber membrane module: First principles model synthesis and steady-state validation

This paper presents a first-principles model for the recovery of dissolved gases from liquids using a sidestream hollow-fiber membrane module. The model avoids the use of new empirical coefficients, thus providing a parametric understanding of the process behavior for future design and optimization of membrane modules. This type of first-principles model could be particularly useful when gas recovery is beneficial to biological or chemical reactions of interest, such as the acetogenesis reactions in two-stage anaerobic digesters. The steady-state behavior of the model was validated against both new experimental data for the recovery of H 2 , CH 4 and H 2 –CH 4 mixtures from pure water, as well as existing published data. The modeled gas recovery predictions agreed with experimental data to an absolute average error of 13%, and an average R value of 0.98. Parametric analysis of mixed-gas recovery suggests possible key transition points in the composition of the recovered gases. For example, at 40 °C, increasing trans-membrane pressure while keeping hydraulic residence time (HRT) under 0.5 s will result in an increase in the ratio of H 2 to CH 4 recovered. Otherwise, increasing trans-membrane pressure will instead decrease the ratio of H 2 to CH 4 recovered. The model has potential to be extended to transient analysis, but has yet to be validated with transient experimental data. Furthermore, this model was successfully implemented in both Python and MATLAB, and provides valuable insights for future net-energy optimization for anaerobic digestion systems with in-situ gas recovery.

Anaerobic Digestion↗

Carbon Storage and Utilization: Perspective on Water Usage and Opportunities

Disseminate technical and non-technical perspective on the opportunities for water recovery from produced water and CO2 storage in the I-WEST region. Concerned citizens and advocacy groups; farmers and ranchers; tribal, state, city, and county leaders; and project leaders working on water-related initiatives are all encouraged to participate in the workshop. This workshop is an opportunity for regional stakeholders to join the conversation about the challenges and opportunities water presents for energy transition in the Inter- Mountain West.

Vikara, Derek↗

Study of Different Formulations for the Multiperiod Blending Problem Applied to Lithium Recovery from Produced Water

We present several formulations to solve the MPBP for the recovery of REE/CMs from produced water and propose a decomposition approach thatleverages strategies in general disjunctive programming to enhance its performance. We compare these proposed formulations/strategies via two illustrative case studies on recovering lithium from a network of produced water sources.

Ovalle, Daniel↗

Electrocoagulation Combined with Ultrafiltration Membranes as Pretreatment for RO Desalination of Synthetic Cooling Tower Blowdown Water

Electrocoagulation (EC), an electrochemical water treatment process, is commonly used to remove particulate and colloidal matter from water. Here, in this study, we demonstrate that EC, when coupled with membrane filtration, is also capable of removing dissolved species, such as Ca + , Mg 2+ , and SiO x . The removal of such species is important for downstream membrane-based desalination treatment of the water that can suffer from reduced performance due to membrane scaling. Here, we describe how EC can be combined with a low-pressure membrane (LPM) system to offer efficient (and potentially universal) pretreatment for downstream membrane desalination. Synthetic water, simulating cooling tower blowdown (CTBD) with elevated concentrations of hardness and silicates (Ca: 418 ppm, Mg: 63 ppm, SiO 2 : 50 ppm) is treated using EC coupled to ultrafiltration (UF) to remove Mg up to 30 ± 1%, Ca up to 29 ± 1%, and silica up to 99 ± 1%. We evaluated the effectiveness of the EC-UF pretreatment system in reducing downstream RO scaling using thermodynamic modeling to predict the saturation index (SI) at the RO membrane/water interface. An SI value below zero (SI < 0) indicates under-saturated conditions (with respect to a particular mineral) where mineral scaling does not take place, which correlates with improved water recovery. Our findings suggest that the EC-UF pretreatment system was able to increase water recovery by up to 30%, compared to 0% recovery without pretreatment, under optimal conditions (feed solution pH of 7 and an EC charge loading of 1800 C/L). Finally, we conducted an economic analysis showing that implementing an EC-UF system for CTBD water could yield a cost benefit of up to $\$$14.13 per m 3 compared to direct brine disposal.

cooling tower blowdown↗

Impact of Organic and Volatile Compounds in Produced Water from Unconventional Reservoirs on Direct Contact Membrane Distillation Permeate Quality

The expansion of oil and gas extraction from unconventional reservoirs has led to an increase in the amount of produced water that has to be managed by this industry. Direct contact membrane distillation (DCMD) is a promising technology for treatment of produced water to enable water recovery and reduce the environmental footprint of this industry. The feasibility of DCMD for the treatment of highly saline produced water from the Permian Basin in TX with commercially available polyethylene and polytetrafluoroethylene membranes was evaluated in this study. An increase in water recovery by a DCMD system operated in the batch (concentrating) mode led to an increase in permeate conductivity. Partial removal of organic compounds from the produced water by biodegradation, chemical oxidation, and/or activated carbon adsorption could not resolve deterioration in permeate quality, and none of the organics observed in the permeate contributed to its conductivity. The observed increase in permeate conductivity was attributed to the passage of ammonia vapor from the feed side followed by protonation on the permeate side. Furthermore, this study revealed that permeate conductivity may not always be a reliable indicator of membrane wetting and underscores the importance of understanding the interactions between specific solutes and membrane materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conducting thermal energy to the membrane/water interface for the enhanced desalination of hypersaline brines using membrane distillation

Membrane distillation (MD) is a membrane-based thermal desalination process capable of treating hypersaline brines. Standard MD systems rely on preheating the feed to drive the desalination process. However, relying on the feed to carry thermal energy is limited by a decline of the thermal driving force as the water moves across the membrane, and temperature polarization. In contrast, supplying heat directly into the feed channel, either through the membrane or other channel surfaces, has the potential of minimizing temperature polarization, increasing single-pass water recoveries, and decreasing the number of heat exchangers in the system. When solar thermal energy can be utilized, particularly if the solar heat is optimally delivered to enhance water evaporation and process performance, MD processes can potentially be improved in terms of energy efficiency, environmental sustainability, or operating costs. Here we describe an MD process using layered composite membranes that include a high-thermal-conductivity layer for supplying heat directly to the membrane-water interface and the flow channel. Here, the MD system showed stable performance with water flux up to 9 L/m 2 /hr, and salt rejection >99.9% over hours of desalinating hypersaline feed (100 g/L NaCl). In addition to bench-scale system, we developed a computational fluid dynamics model that successfully described the transport phenomena in the system.

42 ENGINEERING↗

Separation of volatile organic contaminants from water using a direct-contact dehumidifier: An experimental study and modeling

A packed-bed, direct-contact dehumidifier (PB-DCD) has been developed to selectively condense water from a gaseous mixture of organic contaminants. In this process, hot air is humidified by mixing with wastewater vapor in a static mixer and is dehumidified by subcooled fresh water passing through the PB-DCD in a counter-current configuration. The goal of this study is to understand the relationship between various operating parameters and how they affect separation of isopropyl alcohol (IPA) from the gaseous mixture with the purpose of expanding the investigation to other contaminants in the future. The process has been successfully used to separate IPA from wastewater. Different parameters including the concentration of IPA in water, feed temperature, air-to-vapor ratio, and cooling-water-to-vapor mass ratio, as well as residence time were examined to determine their influence on contaminant separation and clean water recovery rate. The Buckingham Pi theorem was applied to reduce the number of studying variables by generating non-dimensional groups. Experiments were performed to determine the relationship between the non-dimensional parameters and model mass transfer in the system. Mass transfer coefficients for multicomponent gaseous mixture condensation in a packed-bed direct contact condenser column are calculated and a modified correlation of mass transfer is developed. The parameters of the mass transfer model are obtained from operating conditions of the PB-DCD, stream conditions and thermodynamic properties. A modified Sherwood correlation is developed to predict IPA separation from a gaseous mixture consisting of air, water, and IPA. The modified Sherwood correlation is applied to successfully predict the Sherwood number with a mean absolute error equal to 6.6 %. According to the experimental results, the maximum IPA separation achieved was 76.3 %, which corresponds to a water recovery rate of 58.7 %.

42 ENGINEERING↗

Laboratory and pilot-scale studies of membrane distillation for desalination of produced water from Permian Basin

Substantial quantities of produced water generated during the extraction of oil and gas from unconventional reservoirs present significant environmental concern and increase the operating cost for this industry. Membrane Distillation (MD) can serve as a potential solution for beneficial reuse of produced water by generating high-quality permeate and reducing the volume of produced water requiring disposal. This study investigated treatment of produced water from Permian Basin in both laboratory and pilot-scale studies. Laboratory tests revealed the potential to successfully recover 50% of produced water although some increase in permeate conductivity was observed due to the passage of ammonia from the feed side. Initial pilot-scale test with filtration of raw produced water as the only pre-treatment step led to precipitation of SrSO 4 , NaCl, and Fe in the system once the solubility limits for these salts were exceeded. However, chemical pretreatment that included pH adjustment, aeration, and barite precipitation, allowed successful steady-state operation of the AGMD pilot system for 5 days where the produced water was concentrated from 127 g/L to 255 g/L (~50% water recovery) while recovering high quality permeate. Overall, greater than 99.7 % salt rejection was achieved with the average permeate flux of 1.86 LMH. Finally, mass balance analysis suggested potential Ba and Ca precipitation in the system but there was no impact on AGMD performance and permeate quality during 5 days of continuous operation in the field.

42 ENGINEERING↗