Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wavefront reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Using the Gerchberg-Saxton algorithm to reconstruct nonmodulated pyramid wavefront sensor measurements

Adaptive optics (AO) is a technique to improve the resolution of ground-based telescopes by correcting, in real-time, optical aberrations due to atmospheric turbulence and the telescope itself. With the rise of Giant Segmented Mirror Telescopes (GSMT), AO is needed more than ever to reach the full potential of these future observatories. One of the main performance drivers of an AO system is the wavefront sensing operation, consisting of measuring the shape of the above mentioned optical aberrations. Aims. The non-modulated pyramid wavefront sensor (nPWFS) is a wavefront sensor with high sensitivity, allowing the limits of AO systems to be pushed. The high sensitivity comes at the expense of its dynamic range, which makes it a highly non-linear sensor. We propose here a novel way to invert nPWFS signals by using the principle of reciprocity of light propagation and the Gerchberg-Saxton (GS) algorithm. We test the performance of this reconstructor in two steps: the technique is first implemented in simulations, where some of its basic properties are studied. Then, the GS reconstructor is tested on the Santa Cruz Extreme Adaptive optics Laboratory (SEAL) testbed located at the University of California Santa Cruz. This new way to invert the nPWFS measurements allows us to drastically increase the dynamic range of the reconstruction for the nPWFS, pushing the dynamics close to a modulated PWFS. The reconstructor is an iterative algorithm requiring heavy computational burden, which could be an issue for real-time purposes in its current implementation. However, this new reconstructor could still be helpful in the case of many wavefront control operations. In conclusion, this reconstruction technique has also been successfully tested on the Santa Cruz Extreme AO Laboratory (SEAL) bench where it is now used as the standard way to invert nPWFS signal.

47 OTHER INSTRUMENTATION↗

Bench top interferometric test bed for LISA

Adaptive optics systems with Shack-Hartmann wavefront sensors require reconstruction of the atmospheric phase error from slope measurements, with every sensor in the array being used in the computation of each actuator command. This fully populated reconstruction matrix can result in a significant computational burden for adaptive optics systems with large numbers of actuators. A method for generating sparse wavefront reconstruction matrices for adaptive optics is proposed. The method exploits the relevance of nearby slope measurements for control of an individual actuator, and relies upon the limited extent of the influence function for a zonal deformable mirror. Relying only on nearby sensor information can significantly reduce the calculation time for wavefront reconstruction. In addition, a hierarchic controller is proposed to recover some of the global wavefront information. The performance of these sparse wavefront reconstruction matrices was evaluated in simulation, and tested on the Palomar Adaptive Optics System. This paper will present some initial results from the simulations and experiments.

LISA↗

Optical Studies of model binary miscibility gap system

In order to develop a better understanding of separation processes in binary miscibility gap metal alloys, model transparent fluid systems were studied. The system selected was diethylene glycol-ethyl salicylate which has convenient working temperatures (288 to 350 K), low toxicity, and is relatively easy to purify. The system is well characterized with respect to its phase diagram, density, surface and interfacial tensions, viscosity and other pertinent physical properties. Studies of migration of the dispersed phase in a thermal gradient were performed using conventional photomicroscopy. Velocities of the droplets of the dispersed phase were measured and compared to calculated rates which included both Stokes and thermal components. A holographic microscopy system was used to study growth, coalescence, and particle motions. Sequential holograms allowed determination of particle size distribution changes with respect to time and temperature. Holographic microscopy is capable of recording particle densities up to 10 to the 7th power particles/cu cm and is able to resolve particles of the order of 2 to 3 microns in diameter throughout the entire volume of the test cell. The reconstructed hologram produces a wavefront that is identical to the original wavefront as it existed when the hologram was made. The reconstructed wavefront is analyzed using a variety of conventional optical methods.

Lacy, L. L.↗

Resolution-enhanced subpixel phase retrieval method

Phase retrieval is a wavefront sensing method that uses a series of intensity images to reconstruct the wavefront. The resolution of phase retrieval testing is limited mainly by the resolution of intensity images captured by CCD cameras. A subpixel phase retrieval method is presented to retrieve the wave field at subpixel resolution by using the information of a sequence of low-resolution images captured along the propagation direction. In this method, the sampling interval for the wave field under test is smaller than the CCD pixel size in phase reconstruction. The wave field is recovered at subpixel resolution by utilizing the energy conservation relationship between CCD pixels and their subpixels by the subpixel phase retrieval (SPR) algorithm. Numerical experiments have shown that more than a fourfold resolution enhancement can be achieved. The method has also been studied in some experiments under noisy and off-axis conditions. A mirror surface testing experiment was conducted to demonstrate the performance of SPR in the real world. The results of these experiments have shown the effectiveness and robustness of this method. SPR allows low-resolution images to be used to retrieve high-resolution wave fields and will be useful in testing wave fields from large objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional Bragg coherent diffraction imaging of an extended ZnO crystal

A complex three-dimensional quantitative image of an extended zinc oxide (ZnO) crystal has been obtained using Bragg coherent diffraction imaging integrated with ptychography. By scanning a 2.5 µm-long arm of a ZnO tetrapod across a 1.3 µm X-ray beam with fine step sizes while measuring a three-dimensional diffraction pattern at each scan spot, the three-dimensional electron density and projected displacement field of the entire crystal were recovered. The simultaneously reconstructed complex wavefront of the illumination combined with its coherence properties determined by a partial coherence analysis implemented in the reconstruction process provide a comprehensive characterization of the incident X-ray beam.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of an apodized imaged Hartmann wavefront sensor

Here, quantitative wavefront measurements are demonstrated using a Hartmann mask re-imaged onto a camera. The wavefront is reconstructed using standard algorithms applied to the difference of beamlet centroids determined from fluence distributions obtained for two different longitudinal locations of the mask. The wavefront of the optical wave in the object plane is measured independently of imaging-system collimation. Apodization obtained with spatially dithered distributions of small transparent or opaque pixels improves the measurement accuracy by reducing the spatial-frequency content of the mask holes. Simulations and experiments demonstrate the excellent accuracy of this diagnostic over a wide range of parameters, making it suitable, for example, to characterize laser systems.

47 OTHER INSTRUMENTATION↗

Multi-Gbps Fiber-Optic Wavefront Sensing Coherent Optical Receiver

We report recent progress on technology developments at the NASA Glenn Research Center using photonic lanterns for coherent optical communications applications. In particular, the development of a spatial mode-diversity optical receiver using a photonic lantern combined with a photonic integrated circuit (PIC). The PIC is designed for compatibility with the NASA Laser Communication Relay Demonstration’s (LCRD) differential phase-shift keying signaling format. We report on the PIC design and future characterization and packaging efforts. Additionally, we report on the development of a 19-channel photonic lantern and provide updates on efforts to use the photonic lantern as a wavefront sensing device. The photonic lantern insertion loss, and spatial-mode transfer characteristics are detailed, as well as the development of a predictive framework in which the intensities in the 19 single-mode output channels are used to reconstruct the wavefront of the light entering the multi-moded input side of the lantern. Finally, we discuss concepts for potential future systems using photonic lanterns and PICs that combine both wavefront sensing and coherent communications onto a single integrated platform.

Optical Communications↗

WFSUITE: A PYTHON SOFTWARE SUITE FOR X-RAY WAVEFRONT SENDING AND AT-WAVELENGTH METROLOGY

SF-26-025 WFSuite is a graphical and command-line toolkit for coded-mask-based X-ray wavefront sensing and phase reconstruction at synchrotron beamlines. It integrates analysis tools for both relative and absolute speckle-based measurements. In the relative metrology module, WFSuite implements Wavelet-transform-based X-ray Speckle Tracking (WXST) and Wavelet-transform-based Speckle Vector Tracking (WSVT) methods to retrieve differential phase and wavefront distortions by comparing speckle patterns recorded with and without the test sample. In the absolute phase module, WFSuite uses coded-mask speckle patterns and replaces the measured reference with a numerically simulated one, enablingsingle-shot wavefront reconstruction using either WXST or a neural-network-based method (SPINNet).

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Review of phase measuring deflectometry

As a low cost, full-field three-dimensional shape measurement technique with high dynamic range, Phase Measuring Deflectometry (PMD) has been studied and improved to be a simple and effective manner to inspect specular reflecting surfaces. In this review, the fundamental principle and the basic concepts of PMD technique are introduced and followed by a brief overview of its key developments since it was first proposed. In addition, the similarities and differences compared with other related techniques are discussed to highlight the distinguishing features of the PMD technique. In conclusion, we will address the major challenges, the existing solutions and the remaining limitations in this technique to provide some suggestions for potential future investigations.

42 ENGINEERING↗

Multicolor Holography With Phase Shifting

Prototype apparatus constructed to test feasibility of two-color holographic interferometric scheme in which data for reconstructing holographic wavefront obtained with help of phase-shifting technique. Provides two sets of data needed to solve equations for effects of temperature and concentration. Concept extended to holography at three or more wavelengths to measure three or more phenomena associated with significant variations in index of refraction

Vikram, Chandra S.↗

Influence of finite spatial coherence on ptychographic reconstruction

X-ray ptychography is an ultrahigh-resolution scanning coherent diffractive imaging technique, allowing quantitative measurements of extended samples and a simultaneous reconstruction of the illuminating wavefront. Recent development of the mixed-state reconstruction algorithm has triggered a certain interest in utilizing partially coherent X-ray sources for ptychography. Here, we study how finite spatial coherence influences the reconstructed image of a test structure. Our work shows that use of a highly coherent illumination provides images with better spatial resolution and fewer artefacts than the approach with partial coherence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single frame interferogram evaluation

We present a simple and novel algorithm for the phase extraction from a single interferogram based on the spatial processing of interference patterns. This new evaluation procedure is suitable for application in environments where the presence of vibrations impedes the use of a classical phase-shifting interferometry scheme with multiple exposures. The algorithm does not require the introduction of a linear carrier as required in Fourier transform techniques. The addition of a carrier can be a significant drawback, e.g. in the case of wavefronts with strong aberrations where the minimum required linear carrier is not even resolved by the detector. The basic idea relies on the spatial application of a temporal phase-shifting algorithm and an iterative correction process to obtain an accurate reconstruction of the wavefront. The validity and performance of the proposed method is shown with numerical and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards high-resolution ptychographic x-ray diffraction microscopy

Ptychographic x-ray diffraction microscopy is a lensless imaging technique with a large field of view and high spatial resolution, which is also useful for characterizing the wavefront of an x-ray probe. The performance of this technique is degraded by positioning errors due to the drift between the sample and illumination optics. We propose an experimental approach for correcting the positioning errors and demonstrate success by two-dimensionally reconstructing both the wavefront of the focused x-ray beam and the complex transmissivity of the weakly scattering objects at the pixel resolution of better than 10 nm in the field of view larger than 5 {mu}m. This method is applicable to not only the observation of organelles inside cells or nano-mesoscale structures buried within bulk materials but also the characterization of probe for single-shot imaging with x-ray free electron lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-Time Wavefront Control for the PALM-3000 High Order Adaptive Optics System

We present a cost-effective scalable real-time wavefront control architecture based on off-the-shelf graphics processing units hosted in an ultra-low latency, high-bandwidth interconnect PC cluster environment composed of modules written in the component-oriented language of nesC. The architecture enables full-matrix reconstruction of the wavefront at up to 2 KHz with latency under 250 us for the PALM-3000 adaptive optics systems, a state-of-the-art upgrade on the 5.1 meter Hale Telescope that consists of a 64 x 64 subaperture Shack-Hartmann wavefront sensor and a 3368 active actuator high order deformable mirror in series with a 241 active actuator tweeter DM. The architecture can easily scale up to support much larger AO systems at higher rates and lower latency.

GPU↗

Self-Referencing Hartmann Test for Large-Aperture Telescopes

A method is proposed for end-to-end, full aperture testing of large-aperture telescopes using an innovative variation of a Hartmann mask. This technique is practical for telescopes with primary mirrors tens of meters in diameter and of any design. Furthermore, it is applicable to the entire optical band (near IR, visible, ultraviolet), relatively insensitive to environmental perturbations, and is suitable for ambient laboratory as well as thermal-vacuum environments. The only restriction is that the telescope optical axis must be parallel to the local gravity vector during testing. The standard Hartmann test utilizes an array of pencil beams that are cut out of a well-corrected wavefront using a mask. The pencil beam array is expanded to fill the full aperture of the telescope. The detector plane of the telescope is translated back and forth along the optical axis in the vicinity of the nominal focal plane, and the centroid of each pencil beam image is recorded. Standard analytical techniques are then used to reconstruct the telescope wavefront from the centroid data. The expansion of the array of pencil beams is usually accomplished by double passing the beams through the telescope under test. However, this requires a well-corrected, autocollimation flat, the diameter or which is approximately equal to that of the telescope aperture. Thus, the standard Hartmann method does not scale well because of the difficulty and expense of building and mounting a well-corrected, large aperture flat. The innovation in the testing method proposed here is to replace the large aperture, well-corrected, monolithic autocollimation flat with an array of small-aperture mirrors. In addition to eliminating the need for a large optic, the surface figure requirement for the small mirrors is relaxed compared to that required of the large autocollimation flat. The key point that allows this method to work is that the small mirrors need to operate as a monolithic flat only with regard to tip/tilt and not piston because in collimated space piston has no effect on the image centroids. The problem of aligning the small mirrors in tip/tilt requires a two-part solution. First, each mirror is suspended from a two-axis gimbal. The orientation of the gimbal is maintained by gravity. Second, the mirror is aligned such that the mirror normal is parallel to gravity vector. This is accomplished interferometrically in a test fixture. Of course, the test fixture itself needs to be calibrated with respect to gravity.

Korechoff, Robert P.↗

Heterodyne readout for read-write holographic memories

A heterodyne readout technique for read-write holographic memory systems that reconstruct a virtual image wavefront is described and demonstrated. The conventionally recorded hologram is illuminated simultaneously with a suitable combination of temporally modulated reference and modified object waves for readout. Best performance is obtained for temporal phase modulation. The coupling of the illuminating wavefronts by the hologram is analyzed.

Mezrich, R. S.↗