Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wind turbine generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Control and stabilization of the DOE/NASA Mod-1 two megawatt wind turbine generator

This paper describes the controls design, performance simulation process and specialized dynamic considerations for the DOE/NASA Mod 1 wind turbine generator (WTG). It shows controls, structural and utility interface considerations of the wind turbine generator and shows how a wind turbine generator can be integrated with a synchronous power system. Differences with respect to fossil or hydro generation and their implications are vital to long-term WTG reliability and availability and acceptance by utilities and consumers. The paper describes the control performance requirements to provide stable pitch and excitation control with drivetrain torsional dynamics, and the control of power swing stability and utility feeder voltage due to wind gusts.

Barton, R. S.↗

Measurements and observations of noise from a 4.2 megawatt (WTS-4) wind turbine generator

Noise measurements and calculations are being made for large wind turbine generators to develop a data base for use in designing and siting such systems for community acceptance. As part of this program, measurements were made on the WTS-4 wind turbine generator during its acceptance runs. This paper presents the results of these exploratory measurements for power output conditions in the range 1.0 to 4.2 MW. Data include noise levels, spectra, radiation patterns, effects of distance, and the associated perception thresholds for use in the further development of acceptance criteria for this type of machine.

Shepherd, K. P.↗

Integration of Wind Turbine Generation (WTG) into utility generating systems

In order to obtain information required for the economical integration of wind turbine generation into utility systems, performance simulations of the MOD-2 turbine were conducted. The sensitivity of the utility-cost-of-generation to wind turbine performance models and the accuracy of wind velocity forecasts was analyzed. Four different simulation methods were used and the characteristics of each are discussed.

Mccabe, T. F.↗

Synchronization of the ERDA-NASA 100 kW wind turbine generator with large utility networks

The synchronizing of a wind turbine generator against an infinite bus under random conditions is studied for the first time. With a digital computer, complete solutions for rotor speed, generator power angle, electromagnetic torque, wind turbine torque, wind turbine blade pitch angle, and armature current are obtained and presented by graphs. Experiments have been recently performed on the ERDA-NASA 100 kW wind turbine. Experimental results matched computer study results very closely and confirmed that the synchronization can be accomplished by means of the existing speed control system and an automatic synchronizer.

Hwang, H. H.↗

Variable speed generator application on the MOD-5A 7.3 mW wind turbine generator

This paper describes the application of a Scherbiustat type variable speed subsystem in the MOD-5A Wind Turbine Generator. As designed by General Electric Company, Advanced Energy Programs Department, under contract DEN3-153 with NASA Lewis Research Center and DOE, the MOD-5A utilizes the subsystem for both starting assistance in a motoring mode and generation in a controlled airgap torque mode. Reactive power control is also provided. The Scherbiustat type arrangement of a wound rotor machine with a cycloconverter in the rotor circuit was selected after an evaluation of variable speed technologies that followed a system evaluation of drivetrain cost and risk. The paper describes the evaluation factors considered, the results of the evaluations and summarizes operating strategy and performance simulations.

Barton, Robert S.↗

Utility experience with two demonstration wind turbine generators

Edison has committed 360 MW of nameplate generating capacity to wind energy by year 1990 in its long-range generation plan. To reach this goal the Company's wind energy program focuses on three areas: the continuous evaluation of the wind resource, the hands-on demonstration of wind turbine generators (WTG) and an association with wind park developers. Two demonstration WTGs have been installed and operated at Edison's Wind Energy Center near Palm Springs, California: a 3 MW horizontal axis Bendix/Schachle WTG and a 500 kW vertical axis Alcoa WTG. They are part of a one to two year test program during which the performance of the WTGs will be evaluated, their system operation and environmental impact will be assessed and the design criteria of future WTGs will be identified. Edison's experience with these two WTGs is summarized and the problems encountered with the operation of the two machines are discussed.

Wehrey, M. C.↗

Conceptual design of the 7 megawatt Mod-5B wind turbine generator

Similar to MOD-2, the MOD-5B wind turbine generator system is designed for the sole purpose of providing electrical power for distribution by a major utility network. The objectives of the MOD-2 and MOD-5B programs are essentially identical with one important exception; the cost-of-electricity (COE) target is reduced from 4 cent/Kwhr on MOD-2 to 3 cent/Kwhr on MOD-5B, based on mid 1977 dollars and large quantity production. The MOD-5B concept studies and eventual concept selection confirmed that the program COE targets could not only be achieved but substantially bettered. Starting from the established MOD-2 technology as a base, this achievement resulted from a combination of concept changes, size changes, and design refinements. The result of this effort is a wind turbine system that can compete with conventional power generation over significant geographical areas, increasing commercial market potential by an order of magnitude.

Douglas, R. R.↗

Mod-1 Wind Turbine Generator Analysis

A general summary of the MOD-1 wind turbine generator control system and simulation is presented. Mechanical and speed stabilization control means to add drive train damping were mentioned and MOD-1 simulation results showing the effects of speed stabilization are displayed.

Barton, R. S.↗

WTG Energy Systems' MP1-200 200 kilowatt wind turbine generator

The preliminary design criteria of the MP1-200 wind turbine are given along with a brief description of the wind turbine generator. Performance and operational experience and cost factors are included. Recommendations for additional research are listed.

Spaulding, A. P., Jr.↗

Calculation of guaranteed mean power from wind turbine generators

A method for calculating the 'guaranteed mean' power output of a wind turbine generator is proposed. The term 'mean power' refers to the average power generated at specified wind speeds during short-term tests. Correlation of anemometers, the method of bins for analyzing non-steady data, the PROP Code for predicting turbine power, and statistical analysis of deviations in test data from theory are discussed. Guaranteed mean power density for the Clayton Mod-OA system was found to be 8 watts per square meter less than theoretical power density at all power levels, with a confidence level of 0.999. This amounts to 4 percent of rated power.

Spera, D. A.↗

Transient response to three-phase faults on a wind turbine generator

In order to obtain a measure of its responses to short circuits a large horizontal axis wind turbine generator was modeled and its performance was simulated on a digital computer. Simulation of short circuit faults on the synchronous alternator of a wind turbine generator, without resort to the classical assumptions generally made for that analysis, indicates that maximum clearing times for the system tied to an infinite bus are longer than the typical clearing times for equivalent capacity conventional machines. Also, maximum clearing times are independent of tower shadow and wind shear. Variation of circuit conditions produce the modifications in the transient response predicted by analysis.

Gilbert, L. J.↗

Synchronization of the DOE/NASA 100-kilowatt wind turbine generator with a large utility network

The DOE/NASA 100 kilowatt wind turbine generator system was synchronized with a large utility network. The system equipments and procedures associated with the synchronization process were described. Time history traces of typical synchronizations were presented indicating that power and current transients resulting from the synchronizing procedure are limited to acceptable magnitudes.

Gilbert, L. J.↗

Lewis Research Center studies of multiple large wind turbine generators on a utility network

A NASA-Lewis program to study the anticipated performance of a wind turbine generator farm on an electric utility network is surveyed. The paper describes the approach of the Lewis Wind Energy Project Office to developing analysis capabilities in the area of wind turbine generator-utility network computer simulations. Attention is given to areas such as, the Lewis Purdue hybrid simulation, an independent stability study, DOE multiunit plant study, and the WEST simulator. Also covered are the Lewis mod-2 simulation including analog simulation of a two wind turbine system and comparison with Boeing simulation results, and gust response of a two machine model. Finally future work to be done is noted and it is concluded that the study shows little interaction between the generators and between the generators and the bus.

Gilbert, L. J.↗

Noise measurements for single and multiple operation of 50 kw wind turbine generators

The noise characteristics of the U.S. Windpower Inc., 50 kw wind turbine generator were measured at various distances from 30 m to 1100 m and for a range of output power. The generated noise is affected by the aerodynamic wakes of the tower legs at frequencies below about 120 Hz and the blade trailing edge thickness at frequencies of about 2 kHz. Rope strakes and airfoil fairings on the legs did not result in substantial noise reductions. Sharpening the blade trailing edges near the tip was effective in reducing broad band noise near 2 kHz. For multiple machines the sound fields are superposed. A three-fold increase in number of machines (from 1 to 3) results in a predicted increase in he sound pressure level of about 5 dB. The detection threshold for 14 machines operating in a 13 - 20 mph wind is observed to be at approximately 1160 m in the downwind direction.

Hubbard, H. H.↗

Scalable Wind Turbine Generator Bearing Fault Prediction Using Machine Learning: A Case Study

Operation and maintenance (O&M) costs for wind turbines pose a risk to competitiveness and asset owners. With machine-learning technologies and digitalization rapidly maturing, the wind industry is actively investigating these new technologies to optimize O&M practices and reduce costs. This paper reviews recent work on machine-learning approaches to generator bearing failure prediction and presents a relevant real-world case study through a collaboration between the National Renewable Energy Laboratory and Envision Digital Corporation. In the case study, we evaluate the performance of representative machine-learning algorithms for predicting wind turbine generator bearing failures. Operational supervisory control and data acquisition data from one wind power plant was used to train and test the machine-learning models. The investigated data channels are chosen based on whether physically they reflect the failed generator bearing conditions and the component historical usage, including both environmental and operational conditions. Benefits and drawbacks of different methods are identified.

generator bearing failures↗

Broad band sound from wind turbine generators

Brief descriptions are given of the various types of large wind turbines and their sound characteristics. Candidate sources of broadband sound are identified and are rank ordered for a large upwind configuration wind turbine generator for which data are available. The rotor is noted to be the main source of broadband sound which arises from inflow turbulence and from the interactions of the turbulent boundary layer on the blade with its trailing edge. Sound is radiated about equally in all directions but the refraction effects of the wind produce an elongated contour pattern in the downwind direction.

Hubbard, H. H.↗