SEARCH · Search NASA
Results for “Wire chambers”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Threshold and Delay Circuit for Proportional Wire Chamber Electronics
Explore the source record for details and available documents.
Instruction Manual for Proportional Wire Chamber Memory Processor (SLAC 135-078)
Explore the source record for details and available documents.
High Voltage Protection Chassis For Proportional Wire Chambers
Explore the source record for details and available documents.
CINDY, A CAMAC Module for Scanning Proportional Wire Chamber Data
Explore the source record for details and available documents.
Magnetostrictive readout for ''wire spark chambers''
Magnetostriction in nickel wire spark chamber readout lines
A gamma ray telescope utilizing large area wire spark chambers
Gamma ray telescope utilizing wire spark chamber for balloon borne astronomy
Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings
The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.
Numerical studies of transient gain reduction process in a multi-wire proportional chamber
A gain reduction process caused by successive beam irradiation in a multi-wire proportional chamber was numerically investigated to clarify the relations between the gas gain variation and the ion density distribution. A numerical code was developed based on a two-dimensional drift-diffusion model in order to evaluate the ion and electron density distributions and the electric field variation caused by the space charge effect. In order to consider the gain reduction process which occurs under the high rate and successive irradiation, the simulations were performed for the time period of {approx}10-100 {mu}s, which is much longer than the time required for ions to travel from an anode to a cathode. The numerical simulation results showed that for the low gas gain regime of {approx}10, quasi-stationary density distribution of the ions was formed by the high-rate beams of {approx}10{sup 8}- 10{sup 10} particles per second, and that the transient variation of the gas gain became constant after establishment of the quasi-stationary ion density distributions.
Development of the Pixel Chamber
The ionization chamber has been used for centuries recording the radiation. In the early 70, the wire chamber becomes an important device for particle track detection. In the accelerator application, the segment wire ionization chamber become a useful beam monitor device. In the early 80, it was realized in the AGS experimental area that with added integration electronics, the application of SWIC, (Segmented Wire Ionization Chamber) could be extended to the lower intensity beam. It was decided to apply this technique to the SWIC, using small diameter wire to provide gain and integrated electronics to integrate the low level signal. This device was then used in delivery of the Heavy Ion beam , typically 10**5 or less fully stripped Gold, to the experimental area. It was also apply to even lower level of beam, 10^6-10^7 single charged particles, in the secondary beam line
Preparation for a Measurement of Charge Asymmetry in the Bethe-Heitler Process
We have prepared a measurement of the energy asymmetry in wide- and medium-angle electron/positron pair production off protons and heavy targets. This asymmetry is caused by the interference between the first- and second-order Born diagrams and the Compton scattering diagram. It directly probes aspects of QED, as well as providing a direct measurement of the real part of the Compton amplitude. It will be conducted at the HI??S facility at Duke University, using a 60 MeV photon beam. This dissertation serves as documentation of the preparation stage of the Bethe-Heitler experiment. The major was the recommissioning of the vertical drift chambers previously used in the Q-weak experiment at the Jefferson Lab. Cosmic test runs were conducted, drift time data were collected and efficiency plateaus were measured. We made modifications to the JLAB Hall A analyzer to suit the geometry and drift characteristics of these wire chambers. The analyzer was used for the reconstruction of the trajectories of cosmic ray test runs with the results confirmed by direct measurement of trigger geometry. Spatial and angular resolution is estimated to ~300?? and 0.17° respectively. Geant 4 simulations with generated Bethe-Heitler pairs satisfying theoretical differential cross sections. It was used to check detector acceptance, optimize apparatus layout, and estimate measurable energy asymmetry. The measurable asymmetries from electron/positron pairs with polar angles around between approximately 5° and 8°, azimuthal angles differing by 180°, and energy differing by approximately 9 MeV to 15 MeV are predicted to be above 10%. The kinematics of primary vertices are reconstructed using the data from wire chambers in the simulation. The energy resolution is determined to be better than 1MeV.
The application of multi-wire drift chambers in cosmic ray research
Multiwire drift chambers designed for the neutrino experiment at the IHEP U-70 accelerator have found a new application in the MEPhI experiment focused on the detection of ultrahigh-energy cosmic rays. Their high durability and fine spatial and angular characteristics make these chambers perfectly suitable for such studies. The drift chambers were tested at MEPhI and used in constructing the CTUDC coordinatetracking setup, which operated together with the NEVOD water Cherenkov detector and the DECOR detector. The results of the studies of the parameters of drift chambers in the cosmic-ray flux at test benches and in the CTUDC setup are presented.
A gamma ray telescope utilizing large area wire spark chambers.
Gamma ray telescope development for balloon-borne astronomy in search for discrete gamma sources and supernova explosions
SLAC Large Wire Spark Chamber Spectrometer
Explore the source record for details and available documents.
Wire Spark Chamber Spectrometer at SLAC
Explore the source record for details and available documents.
New Digitizing and Memory System for Wire Spark Chambers
Explore the source record for details and available documents.
A Digitizing and Memory System for Wire Spark Chambers
Explore the source record for details and available documents.
Breakdown Limit Studies in High-Rate Gaseous Detectors
We report results from a systematic study of breakdown limits for novel high-rate gaseous detectors: MICROMEGAS, CAT and GEM, together with more conventional devices such as thin-gap parallel-mesh chambers and high-rate wire chambers. It was found that for all these detectors, the maximum achievable pin, before breakdown appears, drops dramatically with incident flux, and is sometimes inversely proportional to it. Further, in the presence of alpha particles, typical of the breakgrounds in high-energy experiments, additional gain drops of 1-2 orders of magnitude were observed for many detectors. It was found that breakdowns at high rates occur through what we have termed an "accumulative" mechanism, which does not seem to have been previously reported in the literature. Results of these studies may help in choosing the optimum detector for given experimental conditions.