Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Intact archeological human bones and age at death studied with transmission x–ray diffraction and small angle x–ray scattering

In this work, high-energy, wide-angle x-ray scattering (WAXS, x-ray diffraction) and small-angle x-ray scattering (SAXS) were used to study intact human second metacarpal bones (mc2) from two UK archeological sites. A novel method correcting for irregular mass distribution was applied in these transmission geometry experiments done at beamline 1-ID of the Advanced Photon Source. The authors asked whether there were age-at-death-related changes in carbonated apatite (cAp) lattice parameters and whether SAXS could detect collagen D-period peaks in the archeological mc2. For each of the two sites, Ancaster and Wharram Percy in England, six female mc2s were studied; for each site, two were from each of three age-at-death cohorts (young, 18-29 years; middle, 30-49 years; old >= 50 years) along with a modern control mc2. The Rietveld method was applied to the WAXS patterns to provide precise lattice parameter values. The cAp lattice parameters did not correlate with age-at-death estimated from dental wear. From WAXS and the 00.2 diffraction peak widths, four archeological mc2s possessed coherently scattering domain lengths (crystallite c-axis sizes) that matched that of the modern mc2; SAXS revealed the same four archeological mc2 had D-period peak intensities equivalent to that of the modern mc2. The other eight archeological mc2s had significantly larger crystallite sizes (than the modern mc2) and weak or absent D-period peaks, differences attributed to diagenetic changes. Based on these data, the authors suggest that WAXS 00.2 peak width and SAXS D-period peak intensity can be used with intact bones to select those likely to retain largely unaltered tissue nanostructure, which might be required for other analyses. Taken as a whole, the results suggest detecting age-related deterioration in nanostructural features may be difficult in bone showing significant bioerosion.

59 BASIC BIOLOGICAL SCIENCES↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

X-Ray Spectroscopic Studies of X-Pinch Plasmas with 3-5 Picosecond Resolution: A Quest for Clear Experimental Evidence for Radiative Collapse in the X-ray Spectra (Final Report)

Dense Z-pinch plasmas produced from current-carrying exploding wires frequently produce very brief (less than 0.1 nanosecond), intense, bursts of soft X-rays from tiny (about 1 micrometer), very hot (10-30 million K) regions of the plasma. This project addresses the physical processes that lead to those tiny, high-energy density plasmas and develops means to measure the conditions just before and during the X-ray bursts. One possible relevant process is radiative collapse, which starts if the power radiated by a dense Z-pinch, proportional to the density-squared, exceeds the resistive heating rate from the current flow, thereby cooling the plasma and enabling the magnetic pinching force to exceed the outward plasma thermal pressure. As the resulting radius reduction further increases the radiation rate, this process produces a runaway magnetic implosion. A competing mechanism is a sausage-like instability that can develop in a Z-pinch plasma at a lower current than is needed to induce radiative collapse. This mechanism can also produce tiny hot spots in the neck regions of the sausage-shaped plasma column. It is also possible that these two mechanisms work together to produce the X-ray emitting hot spots. If radiative collapse does contribute to hot spot formation, it would be terminated when the plasma becomes so dense that the radiation cannot escape, enabling the plasma kinetic pressure to build up and stop the current-driven implosion. This project aims to study the development of the hot spots by means of high temporal and spatial resolution X-ray spectroscopy to determine if there is evidence for the presence of the radiative collapse mechanism. Progress toward this goal is presented. To summarize, during the four-year period 09/15/2017 - 9/14/2021, we have collected necessary spectroscopic data to determine the plasma conditions and continue to do so. We are also now in the process of calibrating diagnostic systems (especially the x-ray streak camera system) and analyzing data to determine plasma conditions as a function of time before, during and after the X-ray burst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray-induced piezoresponse during X-ray photon correlation spectroscopy of PbMg 1/3 Nb 2/3 O 3

X-ray photon correlation spectroscopy (XPCS) holds strong promise for observing atomic-scale dynamics in materials, both at equilibrium and during non-equilibrium transitions. Here an in situ XPCS study of the relaxor ferroelectric PbMg 1/3 Nb 2/3 O 3 (PMN) is reported. A weak applied AC electric field generates strong response in the speckle of the diffuse scattering from the polar nanodomains, which is captured using the two-time correlation function. Correlated motions of the Bragg peak are also observed, which indicate dynamic tilting of the illuminated volume. This tilting quantitatively accounts for the observed two-time speckle correlations. The magnitude of the tilting would not be expected solely from the modest applied field, since PMN is an electrostrictive material with no linear strain response to the field. A model is developed based on non-uniform static charging of the illuminated surface spot by the incident micrometre-scale X-ray beam and the electrostrictive material response to the combination of static and dynamic fields. The model qualitatively explains the direction and magnitude of the observed tilting, and predicts that X-ray-induced piezoresponse could be an important factor in correctly interpreting results from XPCS and nanodiffraction studies of other insulating materials under applied AC field or varying X-ray illumination.

36 MATERIALS SCIENCE↗

Long duration x-ray source development for x-ray diffraction at the National Ignition Facility

We present the results of experiments to produce a 10 ns-long, quasi-monochromatic x-ray source. This effort is needed to support time-resolved x-ray diffraction (XRDt) measurements of phase transitions during laser-driven dynamic compression experiments at the National Ignition Facility. To record XRDt of phase transitions as they occur, we use high-speed (∼1 ns) gated hybrid CMOS detectors, which record multiple frames of data over a timescale of a few to tens of ns. Consequently, to make effective use of these imagers, XRDt needs the x-ray source to be narrow in energy and uniform in time as long as the sensors are active. The x-ray source is produced by a laser irradiated Ge foil. Our results indicate that the x-ray source lasts during the whole duration of the main laser pulse. Both time-resolved and time-integrated spectral data indicate that the line emission is dominated by the He-α complex over higher energy emission lines. Time-integrated spectra agree well with a one-dimensional Cartesian simulation using HYDRA that predicts a conversion efficiency of 0.56% when the incident intensity is 2 × 1015 W/cm2 on a Ge backlighter.

Werellapatha, K. (ORCID:0000000293154054)↗

Anomalous X-Ray Scattering and Extended X-Ray Absorption Fine Structure Study of the Local Structure of CrFeCoNiMo x (x = 0.11, 0.18, and 0.23) High-Entropy Alloys

Anomalous x-ray scattering (AXS) and extended x-ray absorption fine structure (EXAFS) were used to determine the local structure of Mo in CrFeCoNiMo x (x = 0.11, 0.18, and 0.23), a high-entropy alloy with a face-centered cubic (FCC) lattice. No superlattice peaks were observed down to the 10 -4 intensity level. This observation along with the nearly constant decrease of the FCC diffraction peaks above the Mo K absorption edge suggests that Mo atoms have no preferred site occupancy in the FCC lattice. Modeling of the EXAFS data suggests a local chemical order in CrFeCoNiMo x , where in Mo-rich samples (e.g., x = 0.23), Mo atoms are preferably surrounded by lighter atoms, such as Cr.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anthropogenic Influences on the Chemical and Mineral Composition in Pond Sediment by X-Ray Absorption Spectroscopy and X-Ray Powder Diffraction

Manmade detention ponds have historically been impacted by anthropogenic activities such as rainwater runoff, car emissions, and drainage from infrastructures, which can lead to complications for pond ecosystems. Sediment samples collected from the northern, southern, western, and eastern regions of a small pond on a suburban high school campus on Long Island, NY, were analyzed for potential chemical changes resulting from an inundation of water by a broken water main. Incorporating synchrotron X-ray techniques, sediment was analyzed using Submicron Resolution Spectroscopy, Tender Energy X-ray Spectroscopy, and X-ray Powder Diffraction to examine heavy metals, light elements, and minerals. Results include a Zn:Cu ratio increase from 4:1 to 10:1 in the eastern zone and a higher heavy metal presence in the western zone for all elements examined, with greater distribution throughout the pond post-inundation. Lighter elements appear to remain relatively unchanged. The appearance of diopside in the eastern zone post-inundation samples suggests contamination from the water main break, while the presence of carbonate minerals in the western zone is consistent with erosion of asphalt material from the adjacent parking lot.

54 ENVIRONMENTAL SCIENCES↗

Linear and Nonlinear X-ray Spectra of Chiral Molecules: X-ray Circular Dichroism, Sum- and Difference-Frequency Generation of Fenchone and Cysteine

Recent advancements in X-ray light sources enable element-sensitive nonlinear spectroscopies for probing molecular chirality. We simulate X-ray absorption spectroscopy, X-ray circular dichroism (XCD), and nonlinear optical/X-ray SFG and DFG (OX SFG/DFG) signals for two prototypical chiral molecules, fenchone and cysteine. Furthermore, our multireference simulations reproduce experimental data and reveal how novel X-ray spectroscopies exploit the site- and element-sensitivity of X-rays to uncover molecular asymmetry. The XCD spectra show strong asymmetries at chiral centers, while distant atoms contribute weaker signals. The OX SFG/DFG signals, under fixed resonant optical excitation, strongly depend on the core and valence excitations. This allows us to introduce two-dimensional (2D) chirality-sensitive valence-core spectroscopy, which provides insight into the overlap between valence orbitals and local molecular asymmetry. Finally, our estimates using realistic laser and X-ray pulse parameters demonstrate that such nonlinear experiments are feasible at XFELs, offering a promising tool for investigating chiral molecules.

Circular dichroism spectroscopy↗

Asynchronous x-ray multiprobe data acquisition for x-ray transient absorption spectroscopy

Laser pump X-ray Transient Absorption (XTA) spectroscopy offers unique insights into photochemical and photophysical phenomena. X-ray Multiprobe data acquisition (XMP DAQ) is a technique that acquires XTA spectra at thousands of pump-probe time delays in a single measurement, producing highly self-consistent XTA spectral dynamics. In this work, we report two new XTA data acquisition techniques that leverage the high performance of XMP DAQ in combination with High Repetition Rate (HRR) laser excitation: HRR-XMP and Asynchronous X-ray Multiprobe (AXMP). HRR-XMP uses a laser repetition rate up to 200 times higher than previous implementations of XMP DAQ and proportionally increases the data collection efficiency at each time delay. This allows HRR-XMP to acquire more high-quality XTA data in less time. AXMP uses a frequency mismatch between the laser and x-ray pulses to acquire XTA data at a flexibly defined set of pump-probe time delays with a spacing down to a few picoseconds. AXMP introduces a novel pump-probe synchronization concept that acquires data in clusters of time delays. Further, the temporally inhomogeneous distribution of acquired data improves the attainable signal statistics at early times, making the AXMP synchronization concept useful for measuring sub-nanosecond dynamics with photon-starved techniques like XTA. In this paper, we demonstrate HRR-XMP and AXMP by measuring the laser-induced spectral dynamics of dilute aqueous solutions of Fe(CN) 6 4₋ and [Fe II (bpy) 3 ] 2+ (bpy: 2,2'-bipyridine), respectively.

47 OTHER INSTRUMENTATION↗

Unsupervised machine learning for unbiased chemical classification in X-ray absorption spectroscopy and X-ray emission spectroscopy

Here we report a comprehensive computational study of unsupervised machine learning for extraction of chemically relevant information in X-ray absorption near edge structure (XANES) and in valence-to-core X-ray emission spectra (VtC-XES) for classification of a broad ensemble of sulphorganic molecules. By progressively decreasing the constraining assumptions of the unsupervised machine learning algorithm, moving from principal component analysis (PCA) to a variational autoencoder (VAE) to t-distributed stochastic neighbour embedding (t-SNE), we find improved sensitivity to steadily more refined chemical information. Surprisingly, when embedding the ensemble of spectra in merely two dimensions, t-SNE distinguishes not just oxidation state and general sulphur bonding environment but also the aromaticity of the bonding radical group with 87% accuracy as well as identifying even finer details in electronic structure within aromatic or aliphatic sub-classes. We find that the chemical information in XANES and VtC-XES is very similar in character and content, although they unexpectedly have different sensitivity within a given molecular class. We also discuss likely benefits from further effort with unsupervised machine learning and from the interplay between supervised and unsupervised machine learning for X-ray spectroscopies. Our overall results, i.e., the ability to reliably classify without user bias and to discover unexpected chemical signatures for XANES and VtC-XES, likely generalize to other systems as well as to other one-dimensional chemical spectroscopies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of X-ray detection limit and applications in perovskite X-ray detectors

X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

47 OTHER INSTRUMENTATION↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

36 MATERIALS SCIENCE↗

Characterization of MoS 2 films via simultaneous grazing incidence X-ray diffraction and grazing incidence X-ray fluorescence (GIXRD/GIXRF)

Physical vapor deposited (PVD) molybdenum disulfide (nominal composition MoS 2 ) is employed as a thin film solid lubricant for extreme environments where liquid lubricants are not viable. The tribological properties of MoS 2 are highly dependent on morphological attributes such as film thickness, orientation, crystallinity, film density, and stoichiometry. These structural characteristics are controlled by tuning the PVD process parameters, yet undesirable alterations in the structure often occur due to process variations between deposition runs. Nondestructive film diagnostics can enable improved yield and serve as a means of tuning a deposition process, thus enabling quality control and materials exploration. Grazing incidence X-ray diffraction (GIXRD) for MoS 2 film characterization provides valuable information about film density and grain orientation (texture). However, the determination of film stoichiometry can only be indirectly inferred via GIXRD. The combination of density and microstructure via GIXRD with chemical composition via grazing incidence X-ray fluorescence (GIXRF) enables the isolation and decoupling of film density, composition, and microstructure and their ultimate impact on film layer thickness, thereby improving coating thickness predictions via X-ray fluorescence. We have augmented an existing GIXRD instrument with an additional X-ray detector for the simultaneous measurement of energy-dispersive X-ray fluorescence spectra during the GIXRD analysis. This combined GIXRD/GIXRF analysis has proven synergetic for correlating chemical composition to the structural aspects of MoS 2 films provided by GIXRD. We present the usefulness of the combined diagnostic technique via exemplar MoS 2 film samples and provide a discussion regarding data extraction techniques of grazing angle series measurements.

MoS2↗

Observation of Seeded Mn K β Stimulated X-Ray Emission Using Two-Color X-Ray Free-Electron Laser Pulses

Kβ x-ray emission spectroscopy is a powerful probe for electronic structure analysis of 3d transition metal systems and their ultrafast dynamics. Selectively enhancing specific spectral regions would increase this sensitivity and provide fundamentally new insights. Recently we reported the observation and analysis of Kα amplified spontaneous x-ray emission from Mn solutions using an x-ray free-electron laser to create the 1s core-hole population inversion [Kroll et al., Phys. Rev. Lett. 120, 133203 (2018)]. To apply this new approach to the chemically more sensitive but much weaker Kβ x-ray emission lines requires a mechanism to outcompete the dominant amplification of the Kα emission. Here we report the observation of seeded amplified Kβ x-ray emission from a NaMnO 4 solution using two colors of x-ray free-electron laser pulses, one to create the 1s core-hole population inversion and the other to seed the amplified Kβ emission. Comparing the observed seeded amplified Kβ emission signal with that from conventional Kβ emission into the same solid angle, we obtain a signal enhancement of more than 10 5 . Finally, our findings are the first important step of enhancing and controlling the emission of selected final states of the Kβ spectrum with applications in chemical and materials science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗