Development of Cadmium Magnesium Telluride for Picosecond Response X-Ray Optical Laser Photodetector
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Problem / Opportunity Statement: Future high-impact scientific applications at synchrotron and Free-Electron Laser (FEL) X-ray sources require the development of processing and mounting methods for ultra-thin diamond crystals to meet the most challenging needs of pioneering research at next generation light source facilities. These methods should be capable of manufacturing crystal plates as thin as 10 micrometers over an area of a few mm2, and with a surface cut in different crystal orientations, such as the diamond {100}, {111}, {110} and {113} planes. Project Purpose and Approach: In Phase I, Great Lakes Crystal Technologies (GLCT) partnered with Stonybrook University (SUNY) to created thin diamond drumhead crystals. The purpose of the Phase I project is to transfer the drumhead membrane window etching technology from SUNY to GLCT. Testing of a device using the beamline at Stanford Linear Accelerator Laboratory was initially planned, however, a delay on the part of a third party service provided required us to get beamline testing done at Argonne National Laboratory. Phase I Taskwork: Testing of a high purity diamond plate thinning and etching process was performed. By SUNY and GLCT. Plates were sent to a third party service provider for thinning to ~100 microns, however, delays required that GLCT develop an in-house thinning process to complete the taskwork. GLCT successfully developed this in-house capability even though it was initially planned to be part of the Phase II Taskwork. Multiple practice and deliverable plates were provided to SUNY to be etched into the target drumhead devices. GLCT practiced and refined an in-house plate thinning process and produced five plates with thicknesses in the 60 – 150 micron range. Processing of the plates has begun and will continue in a no-cost extension period necessitated by the third party service provider delay. GLCT also procured and installed a reactive ion etching/inductively coupled plasma system. In addition, one of the thinned plates was measured at the Applied Photon Source at APL for a pre-processing assessment of the crystalline strain. After processing the plate into a drumhead and annealing, a post-processing assessment of the strain will be performed. Phase I Results: The initial data from GLCT’s plate thinning process development, SUNY’s drumhead etching processing, and characterization at APS/ANL demonstrate our teams capabilities to achieve the project goals. Commercial Applications & Benefits: The proposed technology will benefit advanced x-ray science performed at BNL and the 70+ additional advanced beamlines around the world. There are also a number of medical and homeland security applications which could benefit from the technology.
A compact low-cost cryocooling system has been designed, constructed, and tested at SLAC National Accelerator Laboratory. The cooling power is provided by natural convection and phase change of the liquid nitrogen. The initial application was to cool silicon crystal optics to the sub-100 K range. A silicon crystal of dimension (width × depth × height) 50 × 50 × 30 mm3 has been used with an electric heater on the top surface in this prototyping test. This system can effectively provide more than 80 W of cooling power to the optics with a consumption of liquid nitrogen less than 2.1 l/h. The vibration of the silicon crystal was monitored during the tests with added electric heater power on the crystal. We note the vibration of the silicon crystal due to liquid nitrogen boiling is negligible.
In this work, we use imaging from the first three years of the Dark Energy Survey to characterize the dynamical state of 288 galaxy clusters at 0.1 ≲ z ≲ 0.9 detected in the South Pole Telescope (SPT) Sunyaev–Zeldovich (SZ) effect survey (SPT-SZ). We examine spatial offsets between the position of the brightest cluster galaxy (BCG) and the centre of the gas distribution as traced by the SPT-SZ centroid and by the X-ray centroid/peak position from Chandra and XMM data. We show that the radial distribution of offsets provides no evidence that SPT SZ-selected cluster samples include a higher fraction of mergers than X-ray-selected cluster samples. We use the offsets to classify the dynamical state of the clusters, selecting the 43 most disturbed clusters, with half of those at z ≳ 0.5, a region seldom explored previously. We find that Schechter function fits to the galaxy population in disturbed clusters and relaxed clusters differ at z > 0.55 but not at lower redshifts. Disturbed clusters at z > 0.55 have steeper faint-end slopes and brighter characteristic magnitudes. Within the same redshift range, we find that the BCGs in relaxed clusters tend to be brighter than the BCGs in disturbed samples, while in agreement in the lower redshift bin. Possible explanations includes a higher merger rate, and a more efficient dynamical friction at high redshift. The red-sequence population is less affected by the cluster dynamical state than the general galaxy population.
Not Available
Explore the source record for details and available documents.
The invention utilizes one exposure without moving parts to provide multiple x-ray views of an object. It relies on a 3D detector, which can be a stack of film plates, and a specified focusing x-ray optic. The x-ray optic, discussed below, allows collection of x-rays from a localized volume, just like an ordinary optical lens, and the stacked film plate, or other 3D detector design, allows collection of the multiple focal plane information from one line of sight.
High-brightness X-rays, as produced at synchrotrons and X-ray free electron laser (XFEL) facilities, are used to characterize materials in a variety of scientific experiments. In most cases, effective use of the high-energy light requires precisely-aligned focusing optics; one example being a compound refractive lens (CRL). To align a CRL, the position and rotation must be optimized along four axes. In practice, this is a labor-intensive, time-consuming manual process that can monopolize scarce experimental time at the necessary X-ray facilities. Models of the expected Xray transmission function suggest that this task can be automated; however, the temporally-varying intensity at X-ray free electron laser facilities preclude the direct use of standard implementations of optimization solvers such as steepest descent algorithms. In this paper, we propose a novel technique to estimate the gradient of noisy functions with temporally-varying amplitudes. We construct this dynamicamplitude correction by systematically sampling a fixed central location within the standard finite difference stencil, accounting for the observed changes in time, and normalizing the difference quotients against those fluctuations. In addition to a rigorous error analysis of the sampling technique, we demonstrate its efficacy in stochastic descent optimization methods. Further, we demonstrate how this approach may be implemented to optimize X-ray focusing optics at synchrotrons or XFEL facilities
High-brightness X-ray pulses, as generated at synchrotrons and X-ray free electron lasers (XFELs), are used in a variety of scientific experiments. At these facilities, measurements often require optical equipment, e.g Compound Refractive Lenses (CRLs) to be precisely aligned and focused. The lateral alignment of CRLs to a beamline requires precise positioning along four axes: two translational, and the two rotational. At a synchrotron, alignment is often accomplished manually. However, XFEL beamlines present a beam brightness that fluctuates stochastically, making manual alignment a time-consuming endeavor. Automation using simplex or classic stochastic descent often fails, given the errant gradient estimates. Herein we present a dynamic-amplitude correction to the usual gradient based on the combination of a generalized finite difference stencil and a time-dependent sampling pattern. Intensity is recorded periodically, then used to normalize numerical derivatives against fluctuations. Error expectation is analyzed, and efficacy is demonstrated on classic benchmarks. We provide a proof of concept by laterally aligning optics on a simulated XFEL beamline using data recorded at both synchrotron and XFEL facilities.
Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.
Abstract Over the past decades, zinc oxide semiconductor and its derivatives have been extensively developed because of its optoelectronic properties. Since ZnO is an intrinsic n-type semiconductor, how to synthesize high-quality p-type ZnO semiconductors and investigate their optoelectronic properties and local chemical structures are important and necessary. In this article, two studies of synthesizing both undoped and phosphorus-doped ZnO nanostructures by hydrothermal method and chemical vapor deposition (CVD) technique are presented. Scanning electron microscopy (SEM) and laboratory X-ray diffraction (XRD) are used to track the surface morphology and the crystalline structure of both undoped and phosphorus doped ZnO nanostructures, respectively. X-ray absorption near edge structures (XANES), X-ray emission spectroscopy (XES) and X-ray excited optical luminescence (XEOL) are also used to determine the local chemical information of both undoped and phosphorus-doped ZnO nano/microstructures such as local symmetry and optical properties. It is found that the phosphorus is successfully doped into the surface of ZnO and substituted the Zn. The phosphorus-doped ZnO products have better crystallinity and less oxygen vacancies on the surface. These two are correlated as one leads to the other. The XEOL results suggest that the average bandgap for undoped and phosphorus doped ZnO is the same, 3.24 eV. The second derivative of the absorption-emission spectra yields the fundamental bandgap for undoped ZnO and phosphorus-doped ZnO is 3.25 eV. The implication of this observation is discussed.
In this review, we advocate describing the liquid dynamics using the Van Hove correlation function, a temporal and spatial correlation function. Recent progress in X-ray optics and X-ray sources makes it possible to carry out inelastic and quasi-elastic x-ray scattering whose spectra can be converted into the dynamic correlation function in real space. We describe the basic concept of the Van Hove correlation function, how it is obtained from the X-ray scattering spectra using synchrotron X-rays and X-ray free electron lasers, and the atomic dynamics in water and aqueous salt solution.
We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.
Techniques are provided for the production of high-contrast, x-ray and/or gamma-ray radiographic images. The images have minimal contributions from object-dependent background radiation. The invention utilizes the low divergence, quasi-monoenergetic, x-ray or gamma-ray output from a laser-Compton source in combination with x-ray optical technologies to produce a converging x-ray or gamma-ray beam with which to produce a high-contrast, shadowgraph of a specific object. The object to be imaged is placed within the path of the converging beam between the x-ray optical assembly and the focus of the x-ray beam produced by that assembly. The beam is then passed through an optically thick pinhole located at the focus of the beam. Downstream of the pinhole, the inverted shadowgraph of the object is then recorded by an appropriate 2D detector array.
This study investigates the elemental composition and surface morphology of solid tribochemical films formed on steel surfaces. The reversible addition-fragmentation chain transfer (RAFT) method was used to synthesize nine different metal-free polymers, which were blended into commercial base oils. The polymers were either homopolymers of dodecyl methacrylate and ethylhexyl methacrylate or were co-polymers of these monomers with six polar monomers. After tribological testing at 100 degrees C using the ball-on-flat geometry, the resulting tribochemical films were imaged using scanning electron microscopy (SEM) and optical microscopy. The resulting tribochemical films have thicknesses around 50-100 nm. Two of the films corresponding to small (P1-imidazole-containing copolymer) and large (P3-less polar homopolymer) wear were cross-sectioned using focused ion beam (FIB) and analyzed for elemental composition using energy-dispersive X-Ray (EDX) mapping. Oxygen and nitrogen enrichment was observed, consistent with the relative chemical composition of the precursor polymers. Transmission electron microscopy (TEM) evidence suggests that at the worn surface, some organic elements penetrate or are mixed into the steel substrate giving an interlocking appearance. The two samples examined with TEM showed that P1 tribofilm is diffused or mixed with the steel substrate more so than P3, suggesting a stronger affinity and contact during tribofilm formation.
A multi-modal approach combining in situ X-ray absorption spectroscopy, optical spectroscopy, and ab initio molecular dynamics simulations was used to investigate and understand nickel metal speciation in molten salt systems.