Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-RAY FLUORESCENCE SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Terrestrial bodies orbiter, LUNAR - A system for detailed global measurements of a planet's properties

The NASA Lunar Polar Orbiter, to be launched by a Delta vehicle in 1980, is designed to perform a global exploration of such moon properties as the gravity field, figure, and surface composition, as well as a lunar resource survey. The paper reviews the mission, spacecraft, and data system concepts in terms of baseline mission sequence, choice of orbits, spacecraft configuration requirements, mission sequence requirements and data system and operations. Scientific experiments planned for the Orbiter mission include geophysical altimetry and gravity experiments, heat flow experiment, magnetic field experiments, measurements of the moon's natural gamma-ray spectrum, X-ray fluorescence of lunar surface materials, sunlight reflectance spectroscopy, and spectro-stereo imaging. Characteristics of instruments designed for use in these investigations are examined. Through the use of advanced sensors and data-system techniques, coupled with well-developed spacecraft systems, the mission promises to return a very large quantity and variety of lunar data at a cost comparable with that of simpler missions in the past.

Burke, J. D.↗

Infrared spectroscopy of simulated Martian surface materials

Mineralogy inferred from the Viking X-ray fluorescence spectrometry (XRFS) is compared with mineralogy indicated by spectral data. The comparison is done by taking laboratory spectra of Viking analog minerals. Both XRFS and infrared data are consistent with clays as the dominant SiO2 containing minerals on Mars. The X-ray fluorescence data might also be consistent with the dominance of certain mafic SiO2 igneous minerals, but the spectral data are probably inconsistent with such materials. Sulfates, inferred by XRFS, are consistent with the spectral data. Inferences following Mariner 9 that high-SiO2 minerals were important on Mars may have been biased by the presence of sulfates. Calcium carbonate, in the quantities indirectly suggested by XRFS are inconsistent with the spectral data, but smaller quantities of CaCO3 are consistent, as are large quantities of other carbonates.

Toon, O. B.↗

EUVE survey observations of the moon

Preliminary survey images of the moon obtained by the Extreme Ultraviolet Explorer and results of data analysis are presented. The preliminary results indicate that the brightness of the moon varies little from observation to observation. Early results also show that the lunar albedo closely matches the relative reflectivity of mineral found on the moon's surface. Further studies are conducted during the spectroscopy phase of the EUVE mission to confirm current results regarding the presence of X-ray fluorescence in the data.

Mcdonald, J. S.↗

Measurement techniques for trace metals in coal-plant effluents: A brief review

The strong features and limitations of techniques for determining trace elements in aerosols emitted from coal plants are discussed. Techniques reviewed include atomic absorption spectroscopy, charged particle scattering and activation, instrumental neutron activation analysis, gas/liquid chromatography, gas chromatographic/mass spectrometric methods, X-ray fluorescence, and charged-particle-induced X-ray emission. The latter two methods are emphasized. They provide simultaneous, sensitive multielement analyses and lend themselves readily to depth profiling. It is recommended that whenever feasible, two or more complementary techniques should be used for analyzing environmental samples.

Singh, J. J.↗

Results from the X-ray polychromator on SMM

Observations of the soft X-ray emitting plasma by means of the X-Ray Polychromator (XRP) on the Solar Maximum Mission satellite are described. The scientific advances achieved by use of the XRP are in the areas of: (1) flare morphology, (2) spectroscopy and plasma diagnostics, (3) chromospheric evaporation and the physics of flare loops, (4) studies of the microwave emission mechanisms of active regions, (5) the fluorescent excitation of Fe II K-alpha radiation, (6) measurement of variations of calcium abundance for X-ray plasmas, and (7) soft X-ray observations of spray transients. The findings in each of these areas are discussed.

Culhane, J. L.↗

Miniaturization in x ray and gamma ray spectroscopy

The paper presents advances in two new sensor technologies and a miniaturized associated electronics technology which, when combined, can allow for very significant miniaturization and for the reduction of weight and power consumption in x-ray and gamma-ray spectroscopy systems: (1) Mercuric iodide (HgI2) x-ray technology, which allows for the first time the construction of truly portable, high-energy resolution, non-cryogenic x-ray fluorescence (XRF) elemental analyzer systems, with parameters approaching those of laboratory quality cryogenic instruments; (2) the silicon avalanche photodiode (APD), which is a solid-state light sensitive device with internal amplification, capable of uniquely replacing the vacuum photomultiplier tube in scintillation gamma-ray spectrometer applications, and offering substantial improvements in size, ruggedness, low power operation and energy resolution; and (3) miniaturized (hybridized) low noise, low power amplification and processing electronics, which take full advantage of the favorable properties of these new sensors and allow for the design and fabrication of advanced, highly miniaturized x-ray and gamma-ray spectroscopy systems. The paper also presents experimental results and examples of spectrometric systems currently under construction. The directions for future developments are discussed.

Iwanczyk, Jan S.↗

High-Resolution Detector For X-Ray Diffraction

Proposed x-ray-sensitive imaging detector offers superior spatial resolution, counting-rate capacity, and dynamic range. Instrument based on laser-stimulated luminescence and reusable x-ray-sensitive film. Detector scans x-ray film line by line. Extracts latent image in film and simultaneously erases film for reuse. Used primarily for protein crystallography. Principle adapted to imaging detectors for electron microscopy and fluorescence spectroscopy and general use in astronomy, engineering, and medicine.

Carter, Daniel C.↗

Development and Testing of Laser-induced Breakdown Spectroscopy for the Mars Rover Program: Elemental Analyses at Stand-Off Distances

One of the most fundamental pieces of information about any planetary body is the elemental composition of its surface materials. The Viking Martian landers employed XRF (x-ray fluorescence) and the MER rovers are carrying APXS (alpha-proton x-ray spectrometer) instruments upgraded from that used on the Pathfinder rover to supply elemental composition information for soils and rocks to which direct contact is possible. These in- situ analyses require that the lander or rover be in contact with the sample. In addition to in-situ instrumentation, the present generation of rovers carry instruments that operate at stand-off distances. The Mini-TES is an example of a stand-off instrument on the MER rovers. Other examples for future missions include infrared point spectrometers and microscopic-imagers that can operate at a distance. The main advantage of such types of analyses is obvious: the sensing element does not need to be in contact or even adjacent to the target sample. This opens up new sensing capabilities. For example, targets that cannot be reached by a rover due to impassable terrain or targets positioned on a cliff face can now be accessed using stand-off analysis. In addition, the duty cycle of stand-off analysis can be much greater than that provided by in-situ measurements because the stand-off analysis probe can be aimed rapidly at different features of interest eliminating the need for the rover to actually move to the target. Over the past five years we have been developing a stand-off method of elemental analysis based on atomic emission spectroscopy called laser-induced breakdown spectroscopy (LIBS). A laser-produced spark vaporizes and excites the target material, the elements of which emit at characteristic wavelengths. Using this method, material can be analyzed from within a radius of several tens of meters from the instrument platform. A relatively large area can therefore be sampled from a simple lander without requiring a rover or sampling arms. The placement of such an instrument on a rover would allow the sampling of locations distant from the landing site. Here we give a description of the LIBS method and its advantages. We discuss recent work on determining its characteristics for Mars exploration, including accuracy, detection limits, and suitability for determining the presence of water ice and hydrated minerals. We also give a description of prototype instruments we have tested in field settings.

D A Cremers↗

Mapping the composition of planetary surfaces by Auger electron spectroscopy

The feasibility of AES as a remote-sensing technique to map the composition of the sunlit surfaces of planetary bodies without atmospheres is studied. Solar X-rays eject photoelectrons from the planetary surface. The resulting ions relax by emission of fluorescence X-rays or Auger electrons, with energies characteristic of the element which is ionized. The spectrum of Auger electrons and photoelectrons is computed for a variety of elements and for representative lunar rock types illuminated by soft-X-ray line and continuum emission typical of solar long-lived coronal active regions. The Auger electron lines for O, Si, Mg, Al, Fe, and Ca in lunar rocks stand well above the continuum background from photoelectrons and backscattered interplanetary electrons, with typical line-to-continuum ratios from about 20 to over 1000.

Lin, R. P.↗

Spectroscopy from 2 to 200 keV

The astrophysical processes responsible for line and continuum emission in the spectra range 2 keV to 200 keV are examined from the viewpoint of designing a spectrometer which would operate in this regime. Phenomena considered include fluorescent line radiation in X-ray binaries, magnetically shifted iron lines and cyclotron emission from neutron star surfaces, line emission from cosmically abundant elements in thermal plasmas, and nuclear deexcitation lines in fresh nucleosynthetically produced matter. An instrument consisting of a approximately 10 sq cm array of planar germanium detectors surrounded by a large sodium-iodide anticoincidence shield is described and projected background rates and sensitivities are considered. A sample observing program for a two-day shuttle-based mission is included as an example of the wide range of scientific questions which could be addressed by such an instrument.

Helfand, D. J.↗

Enhanced orbital geochemical images by the Laplacian subtraction method

Orbital geochemical studies of the moon based on X-ray fluorescence and gamma-ray spectroscopy have been successful. There are, however, difficulties if geologic units or other features to be investigated are too small. Investigations have been conducted with the objective to improve with the aid of image enhancement methods both spatial resolution and contrast for the geochemical experiments. A description is provided of the Laplacian subtraction method of enhancement. It was found that the application of a least-squares version of this method to the Mg/Al ratios obtained by orbital X-ray fluorescence improved geochemical images considerably. The spatial resolution increased by about a factor of 2 and the contrast also increased. The Laplacian of an image can also be used to detect very small 'hot' or 'cold' spots in an image.

Schonfeld, E.↗

A portable x-ray analyzer for wearmetal particles in lubricants

An extensive program exists for the systematic sampling and analysis of lubricants in U.S. Air Force aircraft engines. The sudden development of excessive engine wear can usually be detected on the basis of monitoring the concentration of several key metallic elements for each aircraft engine. In many cases even the specific fault within an engine can be recognized. The two types of equipment which are currently being employed for the conduction of oil analyses make use of atomic emission or atomic absorption spectroscopy. In both cases, heavy, large, and relatively fragile pieces of equipment are involved. Difficulties concerning the transportation of these devices have led to the development of a small, sturdy, and easily portable wearmetal analyzer. The analyzer makes use of an X-ray fluorescence technique.

Clark, B. C.↗

Planetary and satellite x ray spectroscopy: A new window on solid-body composition by remote sensing

The rings and most of the satellites of the outer planets orbit within the radiation belts of their parent bodies. This is an environment with intense fluxes of energetic electrons. As a result, these objects are strong emitters of X-rays. The characteristic X-ray lines from these bodies depend on atomic composition, but they are not sensitive to how the material is arranged in compounds or mixtures. X-ray fluorescence spectral analysis has demonstrated its unique value in the laboratory as a qualitative and quantitative analysis tool. This technique has yet to be fully exploited in a planetary instrument for remote sensing. The characteristic X-ray emissions provide atomic relative abundances. These results are complementary to the molecular composition information obtained from IR, visible, and UV emission spectra. The atomic relative abundances are crucial to understanding the formation and evolution of these bodies. They are also crucial to the proper interpretation of the molecular composition results from the other sensors. The intensities of the characteristic X-ray emissions are sufficiently strong to be measured with an instrument of modest size. Recent developments in X-ray detector technologies and electronic miniaturization have made possible space-flight X-ray imaging and nonimaging spectrometers of high sensitivity and excellent energy resolution that are rugged enough to survive long-duration space missions. Depending on the application, such instruments are capable of resolving elemental abundances of elements from carbon through iron. At the same time, by measuring the bremsstrahlung intensity and energy spectrum, the characteristics of the source electron flux can be determined. We will discuss these concepts, including estimated source strengths, and will describe a small instrument capable of providing this unique channel of information for future planetary missions. We propose to build this instrument using innovative electronics packaging methods to minimize size and weight.

Chenette, D. L.↗

X-ray spectroscopy of AGN with the AXAF 'Microcalorimeter'

A novel technique for X-ray spectroscopy has been configured as part of the definition payload of the AXAF Observatory. It is basically a calorimeter which, operating at 0.1 K, senses the total conversion of single photoelectrically absorbed X-rays via the differential temperature rise of the absorber. The technique promises to achieve less than 10 eV FWHM with near-unit efficiency simultaneously over the entire AXAF bandpass. This combination of high resolution and high efficiency allows for the possibility of investigating thermal, fluorescent and absorption X-ray line features in many types of X-ray source, including a large sample of active galactic nuclei.

Holt, Stephen S.↗

Nature and origin of interstellar diamond from the Allende CV3 meteorite

Data and experimental evidence which support the contention that the C delta diamonds may result from grain-grain collisions in supernova shocks in the interstellar medium are presented. Fragments of the Allende CV3 chondrite were acid-treated. A whitish powder was obtained. For the Analytical Electron Microscopy (AEM) a small drop of ethanol suspension was transferred onto holey carbon support films on 3 mm EM grids. The AEM was performed on transmission-thin fragments of the material which overlay holes in the film, to eliminate interference from the substrate. Electron Spectroscopy for Chemical Analysis (ESCA) was performed on a large aliquot of C. Diamond was identified by selected area electron diffraction. Scanning Transmission Electron Microscope / Energy Dispersive X-ray (STEM-EDS) microanalyses of the C delta diamond, using a light-element detector, show that oxygen and possibly nitrogen are the only impurities consistently present. ESCA spectra from bulk C delta material confirm the presence of N at a level of 0.35 percent or less. Under UV irradiation a yellow-red fluorescence is observed, consistent with that of natural diamonds containing substitutional N. Electron Energy Loss Spectra (EELS) were recorded at 2 eV resolution from the C delta diamond, high pressure synthetic diamond, a diamond film produced in a low pressure plasma by chemical vapor deposition (CVD) on a heated silicon substrate (Roy, 1987), graphite, and amorphous arc sputtered carbon. Comparison of the carbon K edge shape and fine structure shows the Allende C delta phase to be largely diamond, but with a significant pre-edge absorption feature indicative of transitions of C 1s electrons into pi asterisk orbitals which are absent in the purely sp(3)-bonded diamond but present in graphite and amorphous carbon.

Blake, David↗

A Mossbauer investigation of iron-rich terrestrial hydrothermal vent systems: lessons for Mars exploration

Hydrothermal spring systems may well have been present on early Mars and could have served as a habitat for primitive life. The integrated instrument suite of the Athena Rover has, as a component on the robotic arm, a Mossbauer spectrometer. In the context of future Mars exploration we present results of Mossbauer analysis of a suite of samples from an iron-rich thermal spring in the Chocolate Pots area of Yellowstone National Park (YNP) and from Obsidian Pool (YNP) and Manitou Springs, Colorado. We have found that Mossbauer spectroscopy can discriminate among the iron-bearing minerals in our samples. Those near the vent and on the surface are identified as ferrihydrite, an amorphous ferric mineraloid. Subsurface samples, collected from cores, which are likely to have undergone inorganic and/or biologically mediated alteration (diagenesis), exhibit spectral signatures that include nontronite (a smectite clay), hematite (alpha-Fe2O3), small-particle/nanophase goethite (alpha-FeOOH), and siderite (FeCO3). We find for iron minerals that Mossbauer spectroscopy is at least as efficient in identification as X-ray diffraction. This observation is important from an exploration standpoint. As a planetary surface instrument, Mossbauer spectroscopy can yield high-quality spectral data without sample preparation (backscatter mode). We have also used field emission scanning electron microscopy (FESEM), in conjunction with energy-dispersive X ray (EDX) fluorescence spectroscopy, to characterize the microbiological component of surface sinters and the relation between the microbiological and the mineralogical framework. Evidence is presented that the minerals found in these deposits can have multi-billion-year residence times and thus may have survived their possible production in a putative early Martian hot spring up to the present day. Examples include the nanophase property and the Mossbauer signature for siderite, which has been identified in a 2.09-billion-year old hematite-rich chert stromatolite. Our research demonstrates that in situ Mossbauer spectroscopy can help determine whether hydrothermal mineral deposits exist on Mars, which is significant for exobiology because of the issue of whether that world ever had conditions conductive to the origin of life. As a useful tool for selection of samples suitable for transport to Earth, Mossbauer spectroscopy will not only serve geological interests but will also have potential for exopaleontology.

NASA Discipline Exobiology↗

Apollo 15 geochemical X-ray fluorescence experiment - Preliminary report.

Although only part of the information from the X-ray fluorescence geochemical experiment has been analyzed, it is clear that the experiment was highly successful. Significant compositional differences among and possibly within the maria and highlands have been detected. When viewed in the light of analyzed lunar rocks and soil samples, and the data from other lunar orbital experiments (in particular, the Apollo 15 gamma-ray spectroscopy experiment), the results indicate the existence of a differential lunar highland crust, probably feldspathic. This crust appears to be related to the plagioclase-rich materials previously found in the samples from Apollo 11, Apollo 12, Apollo 14, Apollo 15, and Luna 16.

Adler, I.↗