At least 37 records · Page 2

A Miniature Mineralogical Instrument for In-Situ Characterization of Ices and Hydrous Minerals at the Lunar Poles

Lunar missions over the past few years have provided new evidence that water may be present at the lunar poles in the form of cold-trapped ice deposits, thereby rekindling interest in sampling the polar regions. Robotic landers fitted with mineralogical instrumentation for in-situ analyses could provide unequivocal answers on the presence of crystalline water ice and/or hydrous minerals at the lunar poles. Data from Lunar Prospector suggest that any surface exploration of the lunar poles should include the capability to drill to depths of more than 40 cm. Limited data on the lunar geotherm indicate temperatures of approximately 245-255 K at regolith depths of 40 cm, within a range where water may exist in the liquid state as brine. A relevant terrestrial analog occurs in Antarctica, where the zeolite mineral chabazite has been found at the boundary between ice-free and ice-cemented regolith horizons, and precipitation from a regolith brine is indicated. Soluble halogens and sulfur in the lunar regolith could provide comparable brine chemistry in an analogous setting. Regolith samples collected by a drilling device could be readily analyzed by CheMin, a mineralogical instrument that combines X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques to simultaneously characterize the chemical and mineralogical compositions of granular or powdered samples. CheMin can unambiguously determine not only the presence of hydrous alteration phases such as clays or zeolites, but it can also identify the structural variants or types of clay or zeolite present (e.g., well-ordered versus poorly ordered smectite; chabazite versus phillipsite). In addition, CheMin can readily measure the abundances of key elements that may occur in lunar minerals (Na, Mg, Al, Si, K, Ca, Fe) as well as the likely constituents of lunar brines (F, Cl, S). Finally, if coring and analysis are done during the lunar night or in permanent shadow, CheMin can provide information on the chemistry and structure of any crystalline ices that might occur in the regolith samples.

Sarrazin, P.↗

Development and Testing of Laser-induced Breakdown Spectroscopy for the Mars Rover Program: Elemental Analyses at Stand-Off Distances

One of the most fundamental pieces of information about any planetary body is the elemental composition of its surface materials. The Viking Martian landers employed XRF (x-ray fluorescence) and the MER rovers are carrying APXS (alpha-proton x-ray spectrometer) instruments upgraded from that used on the Pathfinder rover to supply elemental composition information for soils and rocks to which direct contact is possible. These in- situ analyses require that the lander or rover be in contact with the sample. In addition to in-situ instrumentation, the present generation of rovers carry instruments that operate at stand-off distances. The Mini-TES is an example of a stand-off instrument on the MER rovers. Other examples for future missions include infrared point spectrometers and microscopic-imagers that can operate at a distance. The main advantage of such types of analyses is obvious: the sensing element does not need to be in contact or even adjacent to the target sample. This opens up new sensing capabilities. For example, targets that cannot be reached by a rover due to impassable terrain or targets positioned on a cliff face can now be accessed using stand-off analysis. In addition, the duty cycle of stand-off analysis can be much greater than that provided by in-situ measurements because the stand-off analysis probe can be aimed rapidly at different features of interest eliminating the need for the rover to actually move to the target. Over the past five years we have been developing a stand-off method of elemental analysis based on atomic emission spectroscopy called laser-induced breakdown spectroscopy (LIBS). A laser-produced spark vaporizes and excites the target material, the elements of which emit at characteristic wavelengths. Using this method, material can be analyzed from within a radius of several tens of meters from the instrument platform. A relatively large area can therefore be sampled from a simple lander without requiring a rover or sampling arms. The placement of such an instrument on a rover would allow the sampling of locations distant from the landing site. Here we give a description of the LIBS method and its advantages. We discuss recent work on determining its characteristics for Mars exploration, including accuracy, detection limits, and suitability for determining the presence of water ice and hydrated minerals. We also give a description of prototype instruments we have tested in field settings.

D A Cremers↗

Sub-Micrometer Scale Minor Element Mapping in Interplanetary Dust Particles: A Test for Stratospheric Contamination

Combined X-ray microprobe (XRM), energy dispersive x-ray fluorescence using a Transmission Electron Microscope (TEM), and electron microprobe measurements have determined that the average bulk chemical composition of the interplanetary dust particles (IDPs) collected from the Earth s stratosphere is enriched relative to the CI meteorite composition by a factor of 2 to 4 for carbon and for the moderately volatile elements Na, K, P, Mn, Cu, Zn, Ga, Ge, and Se, and enriched to approximately 30 times CI for Br. However, Jessberger et al., who have reported similar bulk enrichments using Proton Induced X-ray Emission (PIXE), attribute the enrichments to contamination by meteor-derived atmospheric aerosols during the several weeks these IDPs reside in the Earth s atmosphere prior to collection. Using scanning Auger spectroscopy, a very sensitive surface analysis technique, Mackinnon and Mogk have observed S contamination on the surface of IDPs, presumably due to the accretion of sulfate aerosols during stratospheric residence. But the S-rich layer they detected was so thin (approximately 100 angstroms thick) that the total amount of S on the surface was too small to significantly perturb the bulk S-content of a chondritic IDP. Stephan et al. provide support for the contamination hypothesis by reporting the enrichment of Br on the edges of the IDPs using Time-of-Flight Secondary-Ion Mass-Spectrometry (TOFSIMS), but TOF-SIMS is notorious for producing false edge-effects, particularly on irregularly-shaped samples like IDPs. Sutton et al. mapped the spatial distribution of Fe, Ni, Zn, Br, and Sr, at the approximately 2 m scale, in four IDPs using element-specific x-ray fluorescence (XRF) computed microtomography. They found the moderately volatile elements Zn and Br, although spatially inhomogeneous, were not concentrated on the surface of any of the IDPs they examined, suggesting that the Zn and the Br enrichments in the IDPs are not due to contamination during stratospheric residence.

Flynn, G. J.↗

Definitive Mineralogical Analysis of Mars Analog Rocks Using the CheMin XRD/XRF Instrument

Mineral identification is a critical component of Mars Astrobiological missions. Chemical or elemental data alone are not definitive because a single elemental or chemical composition or even a single bonding type can represent a range of substances or mineral assemblages. Minerals are defined as unique structural and compositional phases that occur naturally. There are about 15,000 minerals that have been described on Earth, all uniquely identifiable via diffraction methods. There are likely many minerals yet undiscovered on Earth, and likewise on Mars. If an unknown phase is identified on Mars, it can be fully characterized by structural (X-ray Diffraction, XRD) and elemental analysis (X-ray Fluorescence, XRF) without recourse to other data because XRD relies on the principles of atomic arrangement for its determinations. XRD is the principal means of identification and characterization of minerals on Earth.

Blake, D. F.↗

Material Analysis and Identification

KeyMaster Technologies, Inc., develops and markets specialized, hand-held X-ray fluorescence (XRF) instruments and unique tagging technology used to identify and authenticate materials or processes. NASA first met with this Kennewick, Washington-based company as the Agency began seeking companies to develop a hand-held instrument that would detect data matrix symbols on parts covered by paint and other coatings. Since the Federal Aviation Administration was also searching for methods to detect and eliminate the use of unapproved parts, it recommended that NASA and KeyMaster work together to develop a technology that would benefit both agencies.

Source record↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Introduction: This paper describes the progress in data acquisition and establishing the observational capability of the AEXS instrument. The AEXS is a miniature instrument[1-4] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam which enables nondestructive evaluation of sample surfaces in planetary ambient atmospheres. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum of the AEXS source from the outside ambient atmosphere. Thus eliminating the need for a vacuum pumped sample chamber as is common in all laboratory SEM s. The transmitted electrons impinge on the sample exciting XRF spectra from the irradiated spot on in-situ or collected samples with sub-mm to cm-scale spatial resolution at Mars atmospheric pressure. The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an XRF detection and analyzer system, and a high voltage power supply. The XRF data are analyzed to determine the elemental abundance for the irradiated spots. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of microfabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. The development of the instrument is described in detail in the poster paper[4] at this conference. This paper focuses on describing the progress of the AEXS instrument to acquire XRF data and using commercially available software to analyze the data streams and determine the accuracy, precision and resolution of the analysis compared to the certified elemental abundance.

Urgiles, E.↗

Identifying Objects via Encased X-Ray-Fluorescent Materials - the Bar Code Inside

Systems for identifying objects by means of x-ray fluorescence (XRF) of encased labeling elements have been developed. The XRF spectra of objects so labeled would be analogous to the external bar code labels now used to track objects in everyday commerce. In conjunction with computer-based tracking systems, databases, and labeling conventions, the XRF labels could be used in essentially the same manner as that of bar codes to track inventories and to record and process commercial transactions. In addition, as summarized briefly below, embedded XRF labels could be used to verify the authenticity of products, thereby helping to deter counterfeiting and fraud. A system, as described above, is called an encased core product identification and authentication system (ECPIAS). The ECPIAS concept is a modified version of that of a related recently initiated commercial development of handheld XRF spectral scanners that would identify alloys or detect labeling elements deposited on the surfaces of objects. In contrast, an ECPIAS would utilize labeling elements encased within the objects of interest. The basic ECPIAS concept is best illustrated by means of an example of one of several potential applications: labeling of cultured pearls by labeling the seed particles implanted in oysters to grow the pearls. Each pearl farmer would be assigned a unique mixture of labeling elements that could be distinguished from the corresponding mixtures of other farmers. The mixture would be either incorporated into or applied to the surfaces of the seed prior to implantation in the oyster. If necessary, the labeled seed would be further coated to make it nontoxic to the oyster. After implantation, the growth of layers of mother of pearl on the seed would encase the XRF labels, making these labels integral, permanent parts of the pearls that could not be removed without destroying the pearls themselves. The XRF labels would be read by use of XRF scanners, the spectral data outputs of which would be converted to alphanumeric data in a digital equivalent data system (DEDS), which is the subject of the previous article. These alphanumeric data would be used to track the pearls through all stages of commerce, from the farmer to the retail customer.

Schramm, Harry F.↗

In Situ Identification of Mineral Resources with an X-Ray-Optical "Hands-Lens" Instrument

The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56). While a sample is being x-rayed, the instrument simultaneously acquires an optical image of the sample surface at magnifications from lx to at least 50x (200x being feasible, depending on the sample surface). We believe that imaging the sample is extremely important as corroborative sample-identification data (the need for this capability having been illustrated by the experience of the Pathfinder rover). Very few geologists would rely on instrument data for sample identification without having seen the sample. Visual inspection provides critical recognition data such as texture, crystallinity, granularity, porosity, vesicularity, color, lustre, opacity, and so forth. These data can immediately distinguish sedimentary from igneous rocks, for example, and can thus eliminate geochemical or mineral ambiguities arising, say between arkose and granite. It would be important to know if the clay being analyzed was part of a uniform varve deposit laid down in a quiescent lake, or the matrix of a megabreccia diamictite deposited as a catastrophic impact ejecta blanket. The unique design of the instrument, which combines Debye-Scherrer geometry with elements of standard goniometry, negates the need for sample preparation of any kind, and thus negates the need for power-hungry and mechanically-complex sampling systems that would have to chip, crush, sieve, and mount the sample for x-ray analysis. Instead, the instrument is simply rested on the sample surface of interest (like a hand lens); the device can interrogate rough rock surfaces, coarse granular material, or fine rock flour. A breadboard version of the instrument has been deployed from the robotic arm of the Marsokhod rover in field trials at NASA Ames, where large vesicular boulders were x-rayed to demonstrate the functionality of the instrument design, and the ability of such a device to comply with constraints imposed by a roving platform. Currently under development is a flight prototype concept of this instrument that will weigh 0.3 kg, using about 4500 J of energy per sample analysis. It requires about 5 min. for XRD analysis, and about 30 min. for XRF interrogation. Its small mass and rugged design make it ideal for deployment on small rovers of the type currently envisaged for the exploration of Mars (e.g., Sojourner-scale platforms). The design utilizes a monolithic P-N junction photodiode pixel array for XRD, a Si PIN photodiode/avalanche photodiode system for XRF, and an endoscopic imaging camera system unobtrusively embedded between the detectors and the x-ray source (the endoscope with its board-mounted camera can be adapted for IR light in addition to visible wavelenths. A rugged, miniature (7 cu cm) x-ray source for the instrument has already been breadboarded.

Marshall, J.↗

Innovative instrumentation for mineralogical and elemental analyses of solid extraterrestrial surfaces: The Backscatter Moessbauer Spectrometer/X Ray Fluorescence analyzer (BaMS/XRF)

We have developed a four-detector research-grade backscatter Moessbauer spectrometer (BaMS) instrument with low resolution x-ray fluorescence analysis (XRF) capability. A flight-qualified instrument based on this design would be suitable for use on missions to the surfaces of solid solar-system objects (Moon, Mars, asteroids, etc.). Target specifications for the flight instrument are as follows: mass less than 500 g; volumes less than 300 cu cm; and power less than 2 W. The BaMS/XRF instrument would provide data on the oxidation state of iron and its distribution among iron-bearing mineralogies and elemental composition information. This data is a primary concern for the characterization of extraterrestrial surface materials.

Shelfer, T. D.↗

In Situ identification of mineral resources with an X-ray-optical "Hand-Lens" instrument

The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56).

Marshall, J.↗

Strategies and Technologies for In Situ Mineralogical Investigations on Mars

Surface landers on Mars (Viking and Pathfinder) have not revealed satisfying answers to the mineralogy and lithology of the planet's surface. In part, this results from their prime directives: Viking focused on exobiology, Pathfinder focused on technology demonstration. The analytical instruments on board the landers made admirable attempts to extract the mineralogy and geology of Mars, as did countless modeling efforts after the missions. Here we suggest a framework for elucidating martian, or any other planetary geology, through an approach that defines (a) type of information required, (b) explorational strategy harmonious with acquisition of these data, (c) interpretation approach to the data, (d) compatible mission architecture, (e) instrumentation for interrogating rocks and soil. (a) Data required: The composition of a planet is ordered at scales ranging from molecules to minerals to rocks, and from geological units to provinces to planetary-scale systems. The largest ordering that in situ compositional instruments can attempt to interrogate is rock type "aggregate" information. This is what the geologist attempts to identify first. From this, mineralogy can be either directly seen or inferred. From mineralogy can be determined elemental abundances and perhaps the state of the compounds as being crystalline or amorphous. Knowledge of rock type and mineralogy is critical for elucidating geologic process. Mars landers acquired extremely valuable elemental data, but attempted to move from elements to aggregates, but this can only be done by making many assumptions and sometimes giant leaps of faith. Data we believe essential are elements, minerals, degree of ordering of compounds, and the aggregate or rock type that these materials compose. (b) Explorational strategy: A lander should function as a surrogate geologist. Of the total landscape, a geologist sees much, but gives detailed attention to an infinitesimally small amount of what is seen. To acquire samples worth detailed scrutiny, as many samples as possible need examining at a cursory or reconnaissance level. A representative, statistically-meaningful sample number cannot be overemphasized. This maxim still applies to geological exploration of our own planet of which we have abundant knowledge. Analysis of many samples mandates low-power consumption per sample. (c) Data interpretation: No single instrument can analyze the full spectrum of the x-axis. An instrument is optimized for detecting certain material characteristics and must therefore affix itself to some point on the x-axis. Any conclusions drawn about data to the left or right of the instrument's position on this axis must necessarily be derived by inference. Hence, it seems logical to include on a mission, instruments that are not closely spaced in their x-axis-position, and if only two analytical methods are used, as shown, they should start at opposite ends of the axis and work towards the center. As examples, we depict a high-resolution camera to evaluate rock type ("aggregate" state) and mineralogy, and an x-ray diffractometer-fluorescence spectrometer (XRD-XRF) to determine elements, minerals, and the degree of order of materials. (d) Mission architecture: No instrument or suite of instruments can be relied upon to always give truly unequivocal analyses. The suite of instruments should therefore permit conclusions of one instrument to be checked against those of another through closed analytical loops. These "loops" can be structured by a combination of orbital imagery, descent imagery, broad-band site viewing/analysis, and data that cover both x and y axes. For example, the detection of a basaltic-looking rock with a microscope should be checked against the elements detected, the appearance of the rock as a lava flow from descent imagery, and so forth. (e) Instrumentation: To satisfy the above criteria, it is necessary to: (i) See the rock or soil with high resolution + magnification, (ii) Examine many samples, (iii) Consume little power per analysis, (iv) Determine elemental species, (v) Determine mineralogy directly (not inferentially) and the degree of ordering of compounds, (vi) Start analyzing from both ends of the x-axis. Every geologist wants to see the hand sample first, and apply a hand lens to its surface. This has not been the starting point for missions to Mars. Thus, our technology satisfies all these criteria . This XRD-XRF-Optical instrument currently being developed, analyses rock or soil surfaces without the need for sample acquisition or preparation; this satisfies the power criterion, and enables many analyses. The device acquires direct mineralogy and determines elemental species. The embedded endoscopic camera satisfies the critical criterion of close inspection of samples; the fiber optic cable can also be used for IR, LTV, or laser sample analysis. Additional information is contained in the original (Figures).

Marshall, J. R.↗

Utilization of independent solar flux measurements to eliminate nongeochemical variation in X-ray fluorescence data

It is shown that the direct method of solar activity correction for lunar XRF data produces XRF data with better statistics than uncorrected data. Direct measurements of the solar flux made by Solrad 10 are converted to emissions of the sun from two assumed temperature regions. These emissions are ratioed to produce emission measure ratios, sensitive indicators of shifts in solar activity. The Tucker-Koren model (1971) of the solar flux is used in the calculation of EMRs and in the calculation of theoretical lunar Si, Al, and Mg fluorescence of maria and highland soils. Al/Si(Mg/Si) ratios calculated at a 'normal' EMR of 0.030 are divided by Al/Si(Mg/Si) ratios at particular EMRs. The relationship between EMR and the quotients of this division, called 'correction factors', is well explained by empirically derived power law functions.

Clark, P. E.↗

A new color correlation method applied to XRF Al/Si ratios and other lunar remote sensing data

Orbital X-ray fluorescence Al/Si intensity ratios, corrected for variations in solar activity, are correlated with normal albedo, elevation measurements from laser altimetry data, and gamma ray data in the 2.75-8.60 MeV range. Each of these data sets is placed into a digital array consisting of 1/4 deg latitude by 1/4 deg longitude pixels. Information relative to the correlation of Al/Si ratios with each of the other data sets is presented in the following forms: (1) histograms are given for each data set to show the frequency distribution within the areas of common coverage; (2) density plots are produced from the plot of a two-dimensional array consisting of the Al/Si ratio vs the other parameter value for each pixel; and (3) color correlation maps are produced by placing the two-dimensional array into a 3 x 3 matrix consisting of nine equal subarrays containing an equal number of data points.

Clark, P. E.↗

X-ray fluorescence analysis of alloy and stainless steels using a mercuric iodide detector

A mercuric iodide detector was used for the XRF analysis of a number of NBS standard steels, applying a specially developed correction method for interelemental effects. It is shown that, using this method and a good peak-deconvolution technique, the HgI2 detector is capable of achieving resolutions and count rates needed in the XRF anlysis of multielement samples. The freedom from cryogenic cooling and from power supplies necessary for an electrically cooled device makes this detector a very good candidate for a portable instrument.

Kelliher, Warren C.↗

Methods for identification and verification using vacuum XRF system

Apparatus and methods in which one or more elemental taggants that are intrinsically located in an object are detected by x-ray fluorescence analysis under vacuum conditions to identify or verify the object's elemental content for elements with lower atomic numbers. By using x-ray fluorescence analysis, the apparatus and methods of the invention are simple and easy to use, as well as provide detection by a non line-of-sight method to establish the origin of objects, as well as their point of manufacture, authenticity, verification, security, and the presence of impurities. The invention is extremely advantageous because it provides the capability to measure lower atomic number elements in the field with a portable instrument.

Schramm, Fred↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Elemental composition of the Martian surface

The Viking landers carried X-ray fluorescence spectrometers (XRFS) to the surface of Mars for direct in-situ measurements of the elemental composition of samples that could be acquired by the surface sampler scoops. A total of 21 samples at two landing sites were acquired and analyzed. In this review, the constraints imposed on the design and operation of the XRFS; the accuracy and precision limitations of XRF; and the interpretation of the results are discussed. The latter includes relevance of the investigation to Martian geological processes, SNC meteorites, the formation and history of Mars, and future mission objectives/capabilities.

Clark, Benton C.↗

CHEMIN: A Mineralogical Dust Analyzer for the Odyssey Mission to Comet Kopff

The Odyssey spacecraft will be launched in June 2006 and will rendezvous with periodic Comet Kopff in September 2009. Odyssey will initially perform slow flybys of the active Kopff nucleus at distances between 500 and 100 km, and will then be placed in orbit around the nucleus at altitudes between 200 and 50 km. Odyssey's scientific payload of seven instruments includes CHEMIN, a mineralogical dust analyzer, which will make the first direct measurements of the crystal structure and elemental composition of cometary dust. CHEMIN will simultaneously perform X-ray Diffraction and X-ray Fluorescence (XRD/XRF) of individual 1-100 micron dust particles collected passively as the spacecraft is immersed in the comet's coma. The instrument has the geometry of a microfocus X-ray camera, with a postage stamp-sized energy-discriminating CCD in place of the film, and a miniature Cu target X-ray tube as the X-ray source. The CHEMIN flight instrument will weigh less than 2 kg., will have a total volume of about 1 liter, and will operate on 3 watts of power. Individual analyses will require 1-2 hours. XRD maxima from 5 to 65 degrees two-theta will be collected, encompassing definitive peaks for all known minerals. XRF data will be simultaneously collected for elements C through U. The instrument has sufficient resolution to allow Rietveld refinement of the diffraction data. Rock types as complex as basalt have been quantitatively analyzed using a CHEMIN laboratory prototype. Selected examples of diffraction experiments performed on more than 30 minerals and rock types by the CHEMIN laboratory prototype will be discussed.

Blake, David↗