Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Image processing of angiograms: A pilot study

The technology transfer application this report describes is the result of a pilot study of image-processing methods applied to the image enhancement, coding, and analysis of arteriograms. Angiography is a subspecialty of radiology that employs the introduction of media with high X-ray absorption into arteries in order to study vessel pathology as well as to infer disease of the organs supplied by the vessel in question.

Larsen, L. E.↗

Design and mathematical analysis of a three-mirror X-ray telescope based on ATM S-056 X-ray telescope hardware

The mathematical design of the aspheric third mirror for the three-mirror X-ray telescope (TMXRT) is presented, along with the imaging characteristics of the telescope obtained by a ray trace analysis. The present design effort has been directed entirely toward obtaining an aspheric third mirror which will be compatible with existing S-056 paraboloidal-hyperboloidal mirrors. This compatability will facilitate the construction of a prototype model of the TMXRT, since it will only be necessary to fabricate one new mirror in order to obtain a working model.

Foreman, J. W., Jr.↗

Multiple loop activations and continuous energy release in the solar flare of June 15, 1973

The spatial and temporal evolution of the high-temperature plasma in the solar flare of June 15, 1973, is studied using XUV spectroheliograms and X-ray filtergrams obtained from Skylab. The analysis focuses on the changing forms and brightness of Fe XXIII 263-A and Fe XXIV 255-A images. Temperatures and emission measures computed for different times during the flare are compared with those derived from Solrad-9 flux data, the electron temperature in the bright compact core of the Fe XXIV image is determined, and a coronal origin is suggested for this bright core. The observational evidence shows that the overall flare event involved a number of different preexisting loops and arches which were activated in succession. The activation and heating are found to have persisted well past the end of the burst phase, implying that the energy release did not end when the impulsive phase was over. The overall development of the flare is summarized on the basis of the observed order of appearance of the loops.

Widing, K. G.↗

Interdisciplinary investigations of comparative planetology

Research supported wholly or in part by NASA's Planetary Programs Office is summarized. Topics covered include: the evaporation of ice in planetary atmospheres: ice-covered rivers on Mars; reducing greenhouses and the temperature history of Earth and Mars; particle motion on Mars inferred from the Viking Lander cameras; the nature and visibility of crater-associated streaks on Mars; the equilibrium figure of Phobos and other small bodies; striations on Phobos; radiation pressure and Poynting-Robertson drag for small spherical particles; direct imaging of extra-solar planets with stationary occultations; the relation between planetology and conventional astrophysics; remote spectral studies and in situ X-ray fluorescence analysis of the Martian surface; small channels on Mars; junction angles of Martian channels; constraints on Aeolian phenomena on Mars; the geology of Mars; and the flow of erosional debris on the Martian terrain.

Sagan, C.↗

Angiocardiography - Past and present

Angiocardiography is defined as an X-ray procedure which uses an intravascularly injected contrast material for visualization of the internal anatomy of the heart and great vessels. Past and present efforts in angiocardiography technology and methodology are reviewed, with special emphasis on qualitative and quantitative measurements of heart and vessel geometry. One of the more recent applications of angiographic image analysis has been for pattern recognition of margin motions over a cardiac cycle, termed contourography. Angiocardiography will continue to serve, as it has served in the past, as the principal standard of reference for calibration and/or comparison of newer methods for determining volume or dimensional change, depending on further technologic advances in X-ray equipment and means for displaying computer-processed information.

Sandler, H.↗

Transmission ultrasonography

Review of the results of the application of an advanced signal-processing technique, called time delay spectrometry, in obtaining soft tissue transmission images by transmission ultrasonography, both in vivo and in vitro. The presented results include amplitude ultrasound pictures and phase ultrasound pictures obtained by this technique. While amplitude ultrasonographs of tissue are closely analogous to X-ray pictures in that differential absorption is imaged, phase ultrasonographs represent an entirely new source of information based on differential time of propagation. Thus, a new source of information is made available for detailed analysis.

Heyser, R. C.↗

Research in Solar Physics: Analysis of Skylab/ATM S-056 X-Ray Data

Data obtained by the X-ray event analyzer are described as well as methods used for film calibration. Topics discussed include analyses of the 15 June 1973 flare, oscillations in the solar soft X-ray flux, and deconvolution of X-ray images of the 5 September 1973 flare.

Henze, W., Jr.↗

Image improvement and three-dimensional reconstruction using holographic image processing

Holographic computing principles make possible image improvement and synthesis in many cases of current scientific and engineering interest. Examples are given for the improvement of resolution in electron microscopy and 3-D reconstruction in electron microscopy and X-ray crystallography, following an analysis of optical versus digital computing in such applications.

Stroke, G. W.↗

Imaging Proportional X-ray Counter for HEAO

The HEAO-B Imaging Proportional Counter (IPC) is an X-ray imaging instrument designed for use in the High Energy Astronomy Observatory - Mission B (HEAO-B) X-ray Telescope. It measures the spatial location of individual X-ray photons by the risetime method and energy of photons by pulse height analysis. The IPC can locate photons in the energy range 0.2 to 4 keV to within 1 mm and provides 5 bits of energy level information. Each measured X-ray event is also time tagged with 7 bits of temporal data. The IPC also includes an in-flight-calibration source and uses a gas control system that maintains the counter gas density constant to an accuracy of 0.25 percent.

Humphrey, A.↗

A correlation study based on Al/Si X-ray fluorescence data from southwestern part of Mare Serenitatis

A correlation study based on Al/Si intensity ratios, broad-spectrum visible-albedo measurements, color-difference photography, color-ratio images, and spectral-reflectivity curves was undertaken to understand why the Tacquet Formation in southwestern Mare Serenitatis has unusually low visible albedos for the Al/Si intensity ratios measured by the Apollo 15 X-ray fluorescence experiment. The statistical analysis of the Al/Si data is described, general correlations among all the remote-sensing data are noted, and correlations in the area of the Tacquet Formation are examined. It is shown that the discrepancy between visible albedos and Al/Si intensities may be due primarily to the presence of unevenly deposited highland-type ejecta from Menaleus crater, although the possibility cannot be excluded that the Tacquet Formation is more complex than a simple mixture of highland and mare materials.

Andre, C. G.↗

Evidence for opposed currents in active region loops

EUV and X-ray images of the sun are used as tracers of the magnetic-field structure in the solar atmosphere in order to study the existence of currents in active regions. Criteria are suggested for comparing the data with theoretical extrapolations of magnetic-field lines above the level of magnetograph observations. Analysis of the data presented in conjunction with force-free field calculations suggests the existence of currents flowing in opposite directions in nearby sets of loops in the active regions considered. Some simple qualitative implications of opposed current structures are suggested.

Levine, R. H.↗

The interpretation of simultaneous soft X-ray spectroscopic and imaging observations of an active region

Simultaneous soft X-ray spectroscopic and broad-band imaging observations of an active region have been analyzed together to determine the parameters which describe the coronal plasma. From the spectroscopic data, models of temperature-emission measure-elemental abundance have been constructed which provide acceptable statistical fits. By folding these possible models through the imaging analysis, models which are not self-consistent can be rejected. In this way, only the oxygen, neon, and iron abundances of Pottasch (1967), combined with either an isothermal or exponential temperature-emission-measure model, are consistent with both sets of data. Contour maps of electron temperature and density for the active region have been constructed from the imaging data. The implications of the analysis for the determination of coronal abundances and for future satellite experiments are discussed.

Davis, J. M.↗

A computer program to evaluate optical systems

A computer program is used to evaluate a 25.4 cm X-ray telescope at a field angle of 20 minutes of arc by geometrical analysis. The object is regarded as a point source of electromagnetic radiation, and the optical surfaces are treated as boundary conditions in the solution of the electromagnetic wave propagation equation. The electric field distribution is then determined in the region of the image and the intensity distribution inferred. A comparison of wave analysis results and photographs taken through the telescope shows excellent agreement.

Innes, D.↗

Vidicon spectral imaging - Color enhancement and digital maps

A silicon imaging photometer system (SIPS) was used to obtain visible and near-infrared spectral imaging data in four narrow bandpasses (0.38, 0.56, 0.85, and 1.05 microns) for a 400-by-400-km lunar region which includes the Serenitatis-Tranquillitatis border. Three ratio frames were used to make color composites of radio images, and spectral maps based on interactive 'cluster' analysis were produced from four video channels. A low albedo titanium-poor unit occurs near the southern edge of the Serenitatis and south of the basin; this unit appears to postdate the high-titanium dark Tranquillitatis and 'blue-ring' material and may be associated with an Al/Si anomaly noticed in Apollo orbital X-ray data.

Johnson, T. V.↗

EUV emission, filament activation and magnetic fields in a slow-rise flare

Results are reported for observations and analysis of synoptic data on a 1B flare that occurred on January 19, 1972. The observations include large-scale H-alpha movies of the flare and pre-flare developments, OSO-7 satellite data on soft X-ray and EUV developments, magnetograms, and hard X-ray observations. Theoretical force-free magnetic field configurations are compared with structures seen in the soft X-ray, EUV, and H-alpha images, and the evolution of the flare is described. The energy available for the flare is estimated from the change of magnetic field inferred from the H-alpha filtergrams and from force-free field calculations. It is suggested that the flare originated in a twisted filament where it was compressed by emerging fields, and it is shown that the flare started below the corona and appeared to derive its energy from the magnetic fields in or near the filament.

Rust, D. M.↗

Iodine imaging using spectral analysis

Existing radiographic imaging systems provide images which represent an integration or averaging over the energy spectrum. In order to provide noninvasive angiography it is necessary to image the relatively small amounts of iodine which are available following an intravenous administration. This is accomplished by making use of the special spectral characteristics of iodine. Two methods will be presented. One involves a special grating for encoding the iodine information in the form of a fine line pattern. This is subsequently decoded to provide images of iodinated structures which are otherwise almost invisible. The second method utilizes a scanned X-ray beam which is rapidly switched in the high energy region. In this region, iodine experiences significant variations in the attenuation coefficient while bone and soft tissue do not. An efficient and accurate X-ray detector can be used with scanned X-ray beams. This provides a high degree of sensitivity enabling the visualization of small vessels containing relatively dilute iodine.

Macovski, A.↗

Spectrophotometry of the transient X-ray source A0620-00

Optical observations of the transient X-ray source A0620-00 over the wavelength range from about 3200 to 6600 A are analyzed which were made with the 5-m Hale telescope using a multichannel spectrometer, a digital spectrograph with a cooled integrating SIT vidicon, and an image photon-counting system attached to the camera of the coude spectrograph. Infrared observations at 1.65, 2.2, and 3.5 microns are also examined. Individual spectral lines of special interest are discussed, the E(B-V) color excess is estimated to be about 0.40, and a distance of 1200 pc is adopted. Analysis of the continuous spectrum yields several simple binary models. A specific model is proposed in which one of the continuum sources is an optically thick object characterized by a model atmosphere at a temperature of 25,000 to 30,000 K and the second source is either a cool black body at 4000 K or a partially optically thick source of bound-free plus free-free radiation from a hydrogen gas with an electron temperature of at least 100,000 K. Some possible parameters of these sources and of the accretion disk are considered.

Oke, J. B.↗