Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Spatiotemporal Studies of Soluble Inorganic Nanostructures with X‐rays and Neutrons

This Review addresses the use of X-ray and neutron scattering as well as X-ray absorption to describe how inorganic nanostructured materials assemble, evolve, and function in solution. We first provide an overview of techniques and instrumentation (both large user facilities and benchtop). We review recent studies of soluble inorganic nanostructure assembly, covering the disciplines of materials synthesis, processes in nature, nuclear materials, and the widely applicable fundamental processes of hydrophobic interactions and ion pairing. Reviewed studies cover size regimes and length scales ranging from sub-Ångström (coordination chemistry and ion pairing) to several nanometers (molecular clusters, i.e. polyoxometalates, polyoxocations, and metal-organic polyhedra), to the mesoscale (supramolecular assembly processes). Reviewed studies predominantly exploit 1) SAXS/WAXS/SANS (small- and wide-angle X-ray or neutron scattering), 2) PDF (pair-distribution function analysis of X-ray total scattering), and 3) XANES and EXAFS (X-ray absorption near-edge structure and extended X-ray absorption fine structure, respectively). While the scattering techniques provide structural information, X-ray absorption yields the oxidation state in addition to the local coordination. Our goal for this Review is to provide information and inspiration for the inorganic/materials science communities that may benefit from elucidating the role of solution speciation in natural and synthetic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking Thermal Transport in Colloidal Quantum Dot Films Using in Situ Time-Resolved X-ray Diffraction

Colloidal quantum dots (QDs) and their thin films are increasingly used in electronic and photonic devices replacing traditional bulk semiconductors. However, thermal properties of QDs remain underexplored relative to device development efforts. This study shows the use of time-resolved X-ray diffraction as a contact-free method to probe the thermal response of QDs in environments representative of the active layer in QD optoelectronic devices, providing in situ insights for future thermal management strategies. Through the extraction of Debye–Waller factors on a subnanosecond time scale, we directly capture the heating and cooling of core/shell CdSe/CdS QDs following pulsed optical excitation. In a QD thin film that actively provides optical gain, the thermal conductivity is found to be as low as 0.13 W m –1 K –1 , because of the poor heat flow between close-packed QD solids. For QDs dispersed in liquids, interfacial thermal conductance dominates thermal relaxation, with a conductance of 15 MW m –2 K –1 .

36 MATERIALS SCIENCE↗

In Situ EXAFS Study of Mo–P Bond Dynamics in Molybdenum Phosphide during CO 2 Reduction and Hydrogen Evolution

Transition Metal Phosphides (TMPs) are widely studied as catalysts in reactions like hydrogen evolution, oxygen reduction, and hydrodesulfurization. TMPs have demonstrated remarkable efficiency in accelerating reactions by providing active sites for adsorption and facilitating the transformation of reaction intermediates, a feature that has increased the interest of TMPs in the electrochemical carbon dioxide reduction reaction (eCO 2 RR). Despite their growing use, the potential-dependent structural behavior of TMPs under operating electrochemical conditions remains insufficiently understood. This work investigates the dynamics of the Mo−P bond during eCO 2 RR and hydrogen evolution reaction (HER) using in situ extended X-ray absorption spectroscopy (EXAFS) studies at the Mo−K edge. Structural characterization of the synthesized MoP nanoparticles was performed by powder X-ray diffraction (XRD) and transmission electron microscopy (TEM). Results of the overall electrochemical activity of MoP are presented through linear sweep voltammetry (LSV) experiments in the potential range of 0 to −1.5 V versus Ag/AgCl and chronoamperometry (CA). Liquid products were analyzed by 1 H NMR spectroscopy. The synthesized catalyst showed increasing activity with the highest Faradaic efficiency of 11.75% for C 2+ products at −1.3 V vs Ag/AgCl. In situ EXAFS revealed a change in the average Mo−P bond distance during eCO 2 RR, whereas no such change was observed during the hydrogen evolution reaction (HER). This finding suggests that phosphorus, particularly through modulation of the Mo−P bond length, plays an important role in the eCO 2 RR and demonstrates how in situ EXAFS can track local structural perturbations in MoP catalysts during electrochemical operation, providing complementary structural insight that correlates with electrochemical behavior.

Catalysts↗

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.

(Ga1- xZnx)(N1-xOx)↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Early results in the search for extreme coronal line emitters with the Dark Energy Spectroscopic Instrument

Here, we present the results of our search through the early data release (EDR) of the Dark Energy Spectroscopic Instrument (DESI) for extreme coronal line emitters (ECLEs) – a rare classification of galaxies displaying strong, high-ionization iron coronal emission lines within their spectra. With the requirement of a strong X-ray continuum to generate the coronal emission, ECLEs have been linked to both active galactic nuclei (AGNs) and tidal disruption events (TDEs). We focus our search on identifying TDE-linked ECLEs. We identify three such objects within the EDR sample, highlighting DESI’s effectiveness for discovering new nuclear transients, and determine a galaxy-normalized TDE-linked ECLE rate of RG=5 −3+5×10−6 galaxy−1 yr−1 at a median redshift of z=0.2 – broadly consistent with previous work. Additionally, we identify more than 200 AGNs displaying coronal emission lines, which serve as the primary astrophysical contaminants in searches for TDE-related events. We also include an outline of the custom python code developed for this search.

Clark, Peter [Southampton U.; Portsmouth U., ICG] ↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Single-shot hard X-ray spectrometer with uniform spatial and spectral response

We demonstrate a single-shot hard X-ray spectrometer based on small-angle scattering from glassy carbon that is insensitive to XFEL beam-dependent spatial and spectral variations. Comparison with established X-ray Thomson scattering diagnostics using stochastic correlation X-ray spectroscopy demonstrates full-bandwidth coverage with meV-scale spectral resolution, enabling reliable single-shot spectroscopic measurements.

47 OTHER INSTRUMENTATION↗

EDXplorer: A Utility for APA Analysis

The automated particle analysis (APA) method of scanning electron microscopy (SEM) energy dispersive X-ray spectroscopy (EDS/EDX) is a useful tool for analyzing the elemental and morphological data of particulate samples. Often, such datasets have many thousands of particles, and it can be difficult to sift through the data to find meaningful trends. EDXplorer is a software utility for processing APA data. They enable the user to easily load data and determine the important components and aspects of the datasets using a powerful and versatile library of data plotting functions, mainly centered around scatter plots and histograms. These programs are intended to fill a void in the data processing of data from certain instruments, where often the user must rely on their own code or other software that is not user-friendly. EDXplorer is intended as a general plotting utility for browsing through data and discovering data trends.

Moseley, Duncan [ORNL] (ORCID:0000000343518347)↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE↗

Mass dependence of halo baryon fractions from the kinetic Sunyaev–Zeldovich effect

ABSTRACT We detect the kinetic Sunyaev–Zeldovich imprint of peculiar motions of galaxy groups and clusters, using the photometric Dark Energy Spectroscopic Instrument Legacy Surveys together with cosmic microwave background (CMB) maps from the Atacama Cosmology Telescope (ACT). We develop a comprehensive forward model based on the AbacusSummit cosmological simulations: Mock galaxy group catalogues and synthetic kinetic Sunyaev–Zeldovich (kSZ) maps are generated, together with a reconstructed peculiar velocity field that allows for photo-z errors, redshift-space distortions, and survey masks. We investigate possible contamination from the cosmic infrared background (CIB), finding that CIB effects are subdominant to the kSZ signal in the relevant ACT frequency channel. We then predict the kSZ signal expected when stacking CMB temperature maps around groups, taking account of their estimated radial velocities. Comparing the model with observations, we are able to constrain the total baryon fraction within haloes, as well as their internal gas profiles. We find evidence for mass dependence of the halo baryon fraction within the virial radius. The gas fraction in massive groups is consistent with the universal baryon fraction, but low-mass groups ($10^{12.5} \lesssim M\, /\, h^{-1}\, \mathrm{M}_\odot \lesssim 10^{14}$) are depleted to $0.38 \pm 0.11$ times the universal baryon fraction. We find this low virial baryon fraction to be consistent with an extended gas profile, for which the total baryon content reaches the universal value well beyond the virial radius. This conclusion is consistent with previous analyses using X-ray, kSZ, and weak lensing, and plausibly reflects energetic feedback processes from the galaxies in these haloes.

Roper, Finn A [Institute for Astronomy, University↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗