Search NASASearch

SEARCH · Search NASA

Results for “X-ray micro-diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

262 records · Page 2

Phase Stability and Electrochemical Performance of La-Site-Doped Li6La3Zr0.5Nb0.5Ta0.5Hf0.5O12 High-Entropy Garnets

We investigate La-site substitution in the high-entropy garnet Li6La3Zr0.5Nb0.5Ta0.5Hf0.5O12 (LLZNTH) using Ba2+, Sr2+, and Sm3+ to elucidate how dopant governs phase stability, Li-site distribution, and electrochemical behavior. X-ray diffraction shows that Sr2+ is incorporated homogeneously into the garnet lattice, whereas the larger Ba2+ and smaller Sm3+ ions partially exceed the structural tolerance, generating secondary phases. Nevertheless, the Sm-doped composition (x = 0.05) exhibits the highest room-temperature ionic conductivity (2.7 × 10–4 S cm–1). Neutron powder diffraction reveals that Sm substitution drives a redistribution of Li+ from the tetrahedral 24 d sites into the higher-mobility 96 h positions, enhancing the connectivity of the three-dimensional Li-ion migration network. A Sm-doping series (x = 0.01–0.05) further shows that only sufficiently high Sm levels induce this redistribution, whereas lower concentrations retain Li arrangements similar to the undoped garnet. Critical current density measurements demonstrate that La-site dopants also influence interfacial stability against Li metal, underscoring a trade-off between bulk transport enhancement and mechanical robustness. Collectively, these findings reveal that in high-entropy garnets improved ionic conductivity can originate not only from phase-pure structures but also from targeted modification of the Li sublattice, even when accompanied by secondary phases, offering a compositional design principle for garnet electrolytes.

Li, Chang [Mechanical Engineering, School of Scien

Tailoring Ion Transport in Li 3‐3y Ho 1+y Cl 6‐x Br x via Transition‐Metal Free Structural Planes and Charge Carrier Distribution

Abstract Localized atomistic disorder in halide‐based solid electrolytes (SEs) can be leveraged to boost Li + mobility. In this study, Li + transport in structurally modified Li 3 HoCl 6 , via Br − introduction and Li + deficiency, is explored. The optimized Li 3‐3 y Ho 1+ y Cl 6‐ x Br x achieves an ionic conductivity of 3.8 mS cm −1 at 25 °C, the highest reported for holmium halide materials. 6,7 Li nuclear magnetic resonance and relaxometry investigations unveil enhanced ion dynamics with bromination, attaining a Li + motional rate neighboring 116 MHz. X‐ray diffraction analyses reveal mixed‐anion‐induced phase transitions with disproportionate octahedral expansions and distortions, creating Ho‐free planes with favorable energetics for Li + migration. Bond valence site energy analysis highlights preferred Li + transport pathways, particularly in structural planes devoid of Ho 3+ blocking effects. Molecular dynamics simulations corroborate enhanced Li + diffusion with Br − introduction into Li 3 HoCl 6 . Li‐Ho electrostatic repulsions in the (001) plane presumably drive Li + diffusion into the Ho‐free (002) layer, enabling rapid intraplanar Li + motion and exchange between the 2d and 4h sites. Li 3‐3 y Ho 1+ y Cl 6‐ x Br x also demonstrates good battery cycling stability. These findings offer valuable insights into the intricate correlations between structure and ion transport and will help guide the design of high‐performance fast ion conductors for all‐solid‐state batteries.

Chemistry

Next-Generation Hard X-ray Missions: SuperHERO and HEROIX

High-energy X-ray observations have transformed our understanding of astrophysical systems where non-thermal processes dominate, from shock-accelerated particles in supernova remnants to relativistic jets and hot coronae in active galactic nuclei. NuSTAR’s pioneering focusing images of the hard X-ray sky have demonstrated the immense scientific potential of this band, while also highlighting how limited angular resolution constrains our ability to fully characterize complex physical processes in faint extended sources and resolving faint sources in crowded sky regions. In this presentation, I will discuss a pathway to overcome these challenges through NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology. Specifically, I will discuss the SuperHERO hard X-ray telescope to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon flight observing the Crab Nebula, and the High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept to achieve an integrated effective area of 570 cm2 at 30 keV with 5 arcsec HPD angular resolution.

AGN

High EneRgy Observatory for Imaging X-rays (HEROIX) Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) is a next-generation broadband X-ray space telescope concept under development as a Medium-Class Explorer mission. Building on more than three decades of replicated NiCo shell technology at NASA’s Marshall Space Flight Center, HEROIX will deliver 5 arcsecond half-power-diameter imaging resolution in the hard X-ray band. The observatory will incorporate four co-aligned telescopes with advanced multilayer coatings, extending the bandpass into the hard X-ray regime and providing an integrated effective area of 380 cm² at 30 keV. A suite of focal plane detectors will enable imaging capability throughout its 1–80 keV bandpass. This combination of angular resolution and high-energy coverage will open new windows into non-thermal processes in extreme astrophysical environments. HEROIXwill deliver transformative science, advancing the astrophysics community’s understanding of supernova physics, the X-ray binary population of the Galactic Center, accretion-driven galaxy evolution, and the origin of the Cosmic X-ray Background.

Nick Thomas

Unraveling interphase-driven failure pathways in LiMn0.6Fe0.4PO4/graphite pouch cells

LiMnxFe1−xPO4 (LMFP) is a promising high-voltage, thermally stable, and earth-abundant cathode material, yet its practical application is limited by interphase instability and Mn dissolution. In this work, we systematically evaluate LiMn0.6Fe0.4PO4/graphite pouch cells using three electrolyte formulations including control carbonate electrolyte, control + 2 wt% vinylene carbonate (VC), and control + 2 wt% VC + 1 wt% 1,3,2-dioxathiolane 2,2-dioxide (DTD), to establish how electrolyte composition governs interphase chemistry and long-term degradation. Electrochemical testing shows that both additives are preferentially reduced prior to ethylene carbonate (EC) during cell formation, generating robust cathode-electrolyte interphase (CEI) and solid-electrolyte interphase (SEI) layers that suppress gas evolution and raise the first-cycle coulombic efficiency to 89.3%. Additionally, the dual-additive electrolyte delivers the most stable performance, retaining over 85% capacity after 600 cycles while minimizing impedance growth under long-term cycling at C/3 and 40 °C. Soft X-ray absorption spectroscopy confirms that VC + DTD effectively suppresses electrolyte oxidation at the cathode surface, and micro-X-ray fluorescence shows substantially reduced Mn dissolution and deposition on the graphite anode. Density functional theory simulations further provided insights into the structural and energetic influences of alkoxide species on the cathode surface, proposing a Mn2+ extraction mechanism. The combined experimental and computational findings establish a mechanistic link between electrolyte composition and interphase evolution, highlighting the effectiveness of electrolyte engineering for extending the operational lifetime of LMFP-based lithium-ion batteries.

Chak, Chanmonirath Michael

Impact of the Annealing Temperature on the Local Se Distribution and Optical Properties in CdSexTe1-x Solar Cells by Multimodal X-ray Microscopy

The introduction of Se in CdTe solar-cell absorbers has led to multiple beneficial effects in the devices, including an increased short-circuit current and an extended charge-carrier lifetime. A critical manufacturing step of CdSexTe1-x solar cells is CdCl2 annealing at high temperatures, during which Se diffuses through the absorber layer. Understanding the local Se distribution in the absorber and its impact on optical properties of the material is key for the further development of this thin-film solar cell technology. In a multimodal x-ray scanning microscopy approach, we investigated the impact of the annealing temperature of CdSexTe1-x solar cells on the Se distribution and on optical characteristics of the material. For this purpose, we exploited an upgraded x-ray excited optical luminescence (XEOL) detection unit that enables simultaneous spectrally and temporally resolved XEOL mapping at synchrotron facilities that are ideal for studying thin-film solar-cell materials with hard x-rays featuring high penetration depth and lateral resolution.

14 SOLAR ENERGY

X-Ray Polarization From the Atoll 4U 1735−44 Suggests a Low Inclination

X-ray polarimetry is a new tool capable of probing the geometry of accretion onto weakly magnetized neutron stars. Here we present the first X-ray spectro-polarimetric results from coordinated observations of the atoll source 4U 1735−44, conducted with the Imaging X-ray Polarimetry Explorer (IXPE), NICER, and NuSTAR . Over the 2–8 keV energy range, we obtained a marginal detection of polarization with the polarization degree of 1.4% ± 0.7% and polarization angle of −29◦ ± 14◦, corresponding to a 3σ upper limit on the polarization degree of 3.5%. The best-fit model to describe the spectrum comprises a thermal component associated with the accretion disk, a Comptonized black body component, and a relativistic reflection component. From the reflection model, we infer a disk inclination of ∼40◦. The spectroscopic and polarimetric properties of 4U 1735−44 are consistent with those observed in other atoll sources studied by IXPE, with its low polarization likely due to its low inclination

X-rays: binaries

X-Ray Polarization of Z-Type Neutron Star Low-Mass X-Ray Binaries II. Spectropolarimetric Analysis

IXPE has provided for the first time detailed energy- and time-resolved X-ray polarimetry of Z-type neutron star low-mass X-ray binaries (NS-LMXBs) as they move along their color-color diagrams (CCDs). These sources can reach the highest polarization observed for NS-LXMBs in the 2–8 keV range when they move along the horizontal branch. In a previous paper, we characterized the spectral state of a sample of Z-sources using the CCD and estimated the polarization with model-independent analysis. Here, we present detailed spectropolarimetric analysis for each source on each branch using data from IXPE, NICER, and NuSTAR. The continuum X-ray emission of all the sources is well described with a combination of thermal accretion disk emission plus a harder Comptonized component. In addition, reflection features, in particular the relativistically broadened Fe Kα line, are observed for our sources, except GX 5–1. For most of the sources and branches, the main contribution to the X-ray emission and polarization is due to Comptonization: moving from the horizontal branch (HB) to the normal branch (NB), the polarization degree (PD) in the 2–8 keV band varies from about 6% to 3–4%, while the PD is loosely constrained in the flaring branch (FB), due to the shorter exposures. These PD values are significantly higher than theoretical expectations for typical spreading or boundary layer configurations. The polarization of the disk is generally lower (below 3%) but still higher than predictions for an electron scattering-dominated, plane-parallel atmosphere above the disk observed at the corresponding inclination. Moreover, the polarization angle (PA) of the disk seems to be significantly misaligned and not perpendicular to that of Comptonization. We find no correlation between the polarization signal and the inclination, nor with the contribution of reflected photons throughout the Z-track.

accretion

Li 21 Ge 8 P 3 S 34 : New Lithium Superionic Conductor with Unprecedented Structural Type

Abstract Lithium superionic conductors are pivotal for enabling all‐solid‐state batteries, which aim to replace liquid electrolytes and enhance safety. Herein, we report the discovery of an unprecedented lithium superionic conductor, Li 21 Ge 8 P 3 S 34 , featuring a novel structural type and a new composition in the Li–Ge–P–S system. This material exhibits high lithium ionic conductivity of approximately 1.0 mS cm −1 at 303 K with a low activation energy of 0.20(1) eV. It's unique crystal structure was elucidated using three‐dimensional electron diffraction (3D ED) and further refined through combined powder X‐ray and neutron diffraction analyses. The structure consists of alternating two‐dimensional slabs: one of corner‐sharing GeS 4 tetrahedra and the other of isolated PS 4 tetrahedra, enabling efficient lithium‐ion transport through a tetrahedrally interconnected network of 1D, 2D, and 3D diffusion pathways. This distinctive structural motif provides a novel design strategy for next‐generation solid electrolytes, broadening the structural landscape of lithium superionic conductors. With further advancements in compositional tuning and interfacial engineering, Li 21 Ge 8 P 3 S 34 could contribute to the development of high‐performance all‐solid‐state batteries.

Chemistry

Structured illumination for surface-resolved grazing-incidence X-ray scattering

Grazing-incidence (GI) scattering techniques are widely used to characterize thin films, offering high surface sensitivity and insight into morphology and structure. However, these approaches typically provide statistical averaged information due to elongated footprint or limited spatial resolution due to beam size. Here we introduce a method that combines structured illumination with GI X-ray scattering and leverages our computational imaging approach to resolve local structural details. We demonstrate that our method captures local features of an organic semiconductor thin film without the need for sample rotation as in tomography. The method expands GI techniques from statistical averaging to high-resolution imaging, thereby providing the capability for detailed analysis of local material properties, such as domain shape, orientation and polymorphism, which are critical for advancing material design towards more efficient and tailored materials.

Gursoy, Doga

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

SuperHERO X-ray Telescope Balloon Mission

The SuperHERO hard X-ray telescope will observe extended sources at unprecedented imaging resolution, revealing the origins of non-thermal emission in extreme astrophysical environments. Employing NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon platform, SuperHERO consists of seven identical, co-aligned telescopes with a combined effective area of 45 cm² at 30 keV. SuperHERO was selected in the APRA 2023 call as a five-year mission, with an inaugural two-day flight scheduled from Fort Sumner, New Mexico, in the fall of 2028. For its initial target, SuperHERO will observe the Crab pulsar wind nebula, localizing hard X-ray emission. Mission development is currently underway, with updates and status to be provided in this presentation.

Nick Thomas

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE

The HEROIX Broadband X-Ray Space Telescope Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept envisions a next-generation broadband X-ray observatory designed to meet the astrophysics community’s need for high-angular-resolution studies of the Cosmic X-ray Background. Building on the science legacy of NASA’s NuSTAR mission and more than 30 years of advances in replicated NiCo shell technology at NASA Marshall, HEROIX proposes a space observatory comprising four co-aligned telescopes achieving 5 arcsecond half-power diameter (HPD) angular resolution. This capability, approached by the resolution demonstrated in the FOXSI-4 sounding rocket mission and under development through the SuperHERO balloon mission, will be extended to energies up to 80 keV through multilayer coatings. Marshall’s inhouse precision optics manufacturing enables an integrated effective area of 380 cm² at 30 keV, which, combined with high-resolution optics, opens new windows into extreme astrophysical non-thermal processes.

Nick Thomas