Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray total scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effect of Rabi dynamics in resonant x-ray scattering of intense attosecond pulses

Here, we theoretically study the effects of Rabi oscillations on resonant x-ray scattering in Ne + using intense attosecond and few-femtosecond pulses. The total photon yield strongly depends on the pulse area and has an upper bound at high intensities. Resonant scattering yields with attosecond pulses can be an order of magnitude higher than those far from resonances. Interference between resonance fluorescence and elastic scattering channels depends on the pulse area and initial state. Our results suggest that resonant x-ray scattering can be exploited for high-resolution, site-specific imaging.

Venkatesh, Akilesh [Argonne National Laboratory (A↗

Effects of Cooling Rates on Self-Reinforced Polyethylene Composites via Multiscale Experimental Characterizations

This study investigates cooling rate effects on self-reinforced polyethylene composites (PE-SRCs), focusing on macroscopic thermal and mechanical properties, and micro- to sub-micron morphologies. Unlike conventional fiber-reinforced composites (e.g., carbon and glass fiber based), cooling rate effects on SRCs remain less studied. PE-SRCs were fabricated from ultrahigh molecular weight polyethylene (UHMWPE) fabric and high-density polyethylene (HDPE) matrix with cooling rates from 0.76°C/min to 425°C/min. Tensile properties, including modulus (~9.5 GPa), strength (~360 MPa), and ultimate elongation (~6%), showed no significant cooling rate dependence. However, thermal analysis revealed melting temperature of HDPE matrix decreased from ~130°C to ~126.5°C with total crystallinity reducing from 84% to 75%. Wide-angle X-ray scattering confirmed decreasing crystallinity but at lower values (67%–59%), as thermal analysis might overestimate crystallinity. Small-angle X-ray scattering showed long period decreased from 24.3 to 17.4 nm, attributed to thinner lamellae and closer packing, suggesting limited crystal growth and faster nucleation. While cooling rates alter melting point and crystalline structures of HDPE matrix, these changes do not translate to substantial impact on macroscale mechanical properties of PE-SRCs. This insensitivity might be related to low interfacial shear strength at PE/PE interfaces, enabling process optimization while maintaining mechanical performance.

Cooling rate↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Limited proteolysis of pea protein to promote aggregation/gelation: role of enzyme concentration and molecular characteristics

Limited proteolysis promotes aggregation/gelation of plant proteins, but its relationship with the molecular characteristics of hydrolysates remains poorly understood. In here, response surface methodology was employed to evaluate the effects of protein concentration, Alcalase level, and hydrolysis time on the storage modulus (G′) of pea protein hydrolysates (PPH). 7.5% protein, 1.65% Alcalase, and a 6-min reaction time resulted in the highest relative increase in G′ upon heating PPH, whereas both higher (3.55%) and lower (0.3%) Alcalase levels led to less increment. Increasing the Alcalase level increased the degree of hydrolysis while decreasing the molecular weight, surface hydrophobicity, and total sulfhydryl and disulfide bond contents of PPH. Confocal laser scanning microscopy and X-ray scattering analyses found PPH produced with 1.65% Alcalase formed interconnected aggregates with dual structural domains, but not at other Alcalase conditions. These results demonstrate the role of controlled proteolysis in governing the aggregation/gelation behavior of PPH.

X-ray scattering↗

Probing the local structure of Bi 2 O 3 chemical derivatives: the neglected cation sublattice

High-resolution synchrotron X-ray diffraction data confirm the stabilization of the average structure at ambient temperatures as a defect fluorite structure in ternary and quaternary oxides of Bi 2 O 3 , where some Bi cations are replaced with Dy 3+ and/or Er 3+ , Nb 5+ and W 6+ . Rietveld refinement of the diffraction data indicates that when the larger cation Er 3+ (0.89 Å) is replaced with smaller cations W 6+ (0.42 Å) and/or Nb 5+ (0.48 Å), the unit-cell parameter a, based on the relative ionic radii of the substituents, counterintuitively increases. Total scattering data show that the identity of the cation substituent is important in determining the positions of some Bi cations in the defect fluorite structure. Er 3+ and Dy 3+ cations induce monoclinic-like distortions that extend only locally in the Bi 3+ sublattice. X-ray absorption spectroscopy provides evidence that some Dy cations, in the δ phases, prefer to keep a similar local environment to that in the parent Dy 2 O 3 . W cations are found to be predominantly tetrahedrally coordinated in the δ phases explored in this work.

36 MATERIALS SCIENCE↗

Neutron Total Scattering Analysis of Materials for the Nuclear Fuel Cycle

Here, this paper reviews recent experimental efforts at the University of Tennessee and Oak Ridge National Laboratory to comprehensively characterize the structural details of materials relevant for the nuclear fuel cycle by employing advanced neutron scattering techniques. For the study of nuclear ceramics, neutron scattering offers distinct advantages over traditional laboratory or synchrotron X-ray diffraction, including enhanced sensitivity to elements with a low atomic mass, such as oxygen, nitrogen, and carbon. The key to these efforts is the recent advancement in the neutron scattering infrastructure at the high-flux diffractometers at the Spallation Neutron Source. The high neutron flux at these instruments enables neutron total scattering, a nondestructive bulk technique that simultaneously captures both short-range structural effects through pair distribution function analysis and long-range order through diffraction pattern analysis. This approach is particularly important for a comprehensive description of defective, disordered, or amorphous nuclear materials. The case studies presented here include analyses of the local defect structure in hyperstoichiometric uranium oxides and short-range order of ion-irradiated ceramics. This advanced analytical methodology will improve our understanding of the behavior of materials in extreme environments and contribute to the development of more resilient nuclear materials.

Neutron scattering↗

Optimizing microfluidic flow cell geometry for in situ resonant soft X-ray characterization of molecular nanostructures

Liquid-phase resonant soft X-ray scattering (LP-RSoXS) is an emerging label-free technique to probe chemically resolved nanostructures of molecular or hybrid materials in liquid environments. Still, quantitative analysis is hindered by the pressure-induced deformation of thin silicon nitride (SiN) membranes used as windows in microfluidic flow cells, which attenuates the signal in nonlinear ways, making experimental optimization difficult. Here, in this work, we directly characterize this deformation under experimental conditions for a variety of cell configurations. We use this to develop a predictive model that combines transmission effects of SiN bowing, incident X-ray beam profiles, and material-dependent resonant scattering cross sections to simulate the effective scattering intensity at the detector across the carbon K-edge. Maps of the total signal across the flow cell window reveal that increasing the window width and polymer concentration shifts the anisotropic intensity distributions from the center toward the edges of the window. It was determined that an optimal SiN thickness of 50 nm, with a window aperture of 104 μm, maximizes the total signal for typical solute concentrations and energies across the carbon K-edge. Our results overturn the assumption that corner regions dominate the scattering signal, offering explicit design guidelines for maximizing LP-RSoXS signals and significantly advancing the quantitative application of this technique to the characterization of molecular and hybrid nanostructured materials in liquids.

Grabner, Devin [Washington State Univ., Pullman, W↗

Quantum Interference in Two-Atom Resonant X-ray Scattering of an Intense Attosecond Pulse

We theoretically investigate resonant x-ray scattering from two noninteracting Ne+ ions driven by an intense attosecond pulse using a nonrelativistic, QED-based time-dependent framework. Our model includes Rabi oscillations, photoionization, Auger decay, and quantum interference among elastic scattering and resonance fluorescence pathways. We analyze how the total scattering signal depends on pulse intensity, atomic configuration, and initial electronic state. We find that the total resonant scattering yield exceeds its nonresonant counterpart; the angular dependence of the signal qualitatively resembles a two-atom structure factor; and the visibility of interference fringes is sensitive to pulse area and the initial electronic state. Only a subset of final states reached via resonance fluorescence exhibits interference, determined by the indistinguishability of photon emission pathways. Fringe visibility is maximized in the linear scattering regime, where ionization is minimal and resonance fluorescence pathways can be largely indistinguishable. These results highlight optimal conditions for applying ultrafast resonant x-ray scattering to single-particle imaging.

Venkatesh, Akilesh↗

Ion Clusters in Multicomponent Solutions Determined from X-ray PDF and SAXS Analysis: The NaNO 2 –NaOH–H 2 O System

Here, this study explores ion cluster formation in the NaNO 2 –NaOH–H 2 O system to understand how ion cluster formation is influenced by the composition in multicomponent mixtures. X-ray pair distribution function (PDF) and small-angle X-ray scattering (SAXS) identified complex ion clusters in concentrated NaNO 2 and NaOH solutions as well as their mixtures. PDF analysis showed that the Na–O distance depended primarily on total Na + concentrations rather than anion composition, whereas the nitrite-water oxygen distance stayed the same regardless of concentration or composition. This result indicates that the nitrite ion hydration was relatively independent of composition. SAXS confirms local fluctuations and coherent clusters with notable size differences between NaOH and NaNO 2 solutions. SAXS analysis of mixed solutions shows that their clusters are an average of the individual solutions, indicating mixed clusters.

Reynolds, Jacob G. [Central Plateau Cleanup Compan↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗

Actinide 5f Occupations: The Case of PuO 2

In actinide chemistry, the formal number of open-shell 5f electrons, n open , is a well-defined quantity with an integer value. The effective 5f occupation, n f , additionally takes donation and back-donation into account, generally has a non-integer value, and has varying numerical definitions. The present study explores the important distinction between n f and n open in actinide chemistry with the example of PuO2, by using electronic structure methods with a relativistic Hamiltonian in combination with experimental Pu M 5 -edge high-energy-resolution X-ray absorption and emission spectroscopic data. The total donation to the metal in PuO 2 is between 3.1 and 2.4 electrons, depending on the type of calculation, most of which is to the Pu 6d and 5f shells. The donation into 5f is sensitive to the approximations in the electronic structure model but likely amounts to 1.6/0.8 electrons when the diffuse regions of the 5f shell are included/excluded. Valence band resonant inelastic X-ray scattering experiments demonstrate that Pu 5f electron density is present in the valence band; thus, there is a clear experimental signature of covalent bonding in PuO 2 . Pu M 5 -edge and M 3 -edge high-energy-resolution X-ray absorption near-edge structures for Pu 3+ and Pu 4+ in an aqueous solution are compared to PuO 2 , showing that Pu in PuO 2 has an nf closer to Pu 4+ (aq).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Intercalation-Induced Amorphization Boosts Aqueous Magnesium-Ion Storage

The design of aqueous battery cathode materials that can store divalent ions with high capacity and satisfactory reversibility is of great technical importance and challenge. Here, we report that divalent Mg 2+ storage is facilitated by an intercalation-induced amorphization of vanadate electrode materials. Electrokinetic analyses and in situ synchrotron X-ray diffraction and absorption spectroscopy collectively demonstrate that vanadate layered materials (Li–V 3 O 8 ) undergo a structural transformation to amorphization induced by Mg 2+ intercalation, and a reversible restoration of crystalline structure upon Mg 2+ deintercalation. Debye scattering simulations suggest that intercalation-induced turbostratic disorder, especially random rotations, translational shifts, oscillatory motions, or varied interlayer spacing of adjacent V–O molecular layers, could be responsible for the observed amorphization. The highly distorted local structure, in turn, facilitates Mg 2+ intercalation across the vanadate electrode materials, responsible for nearly 3/7 of the total Mg 2+ ions intercalated. The study presented reveals an intriguing relationship between ion transport and the reversible amorphization-to-crystallization dynamics it induces, opening a paradigm for designing advanced aqueous battery electrodes.

36 MATERIALS SCIENCE↗

Structure of Complex Liquid–Liquid Extraction Organic Phases for Rare Earth Separations

Complex, multicomponent liquids with hierarchical structure and phase transitions are encountered in many natural and industrial processes, including in chemical separations. One notable example is aggregation and organic phase splitting in liquid–liquid extraction (LLE) of metal ions. While these two phenomena that have long been closely associated, a mechanistic link between mesoscale structure and the capacity-limiting organic phase splitting remains elusive due to complexity of these systems. Here, in this study, we combine small-angle X-ray scattering (SAXS), X-ray photon correlation spectroscopy (XPCS), and molecular dynamics simulation to reveal a comprehensive picture of structure at the nano- and mesoscale in these complex solutions. For the representative case of rare earth extraction from an acidic aqueous phase by a malonamide extractant in dodecane, we investigate a wide range of process-relevant extractant and acid concentrations to provide a complete picture of how aggregation depends on composition. We decompose organic phase structure from SAXS into two contributions, which together can capture the scattering at all compositions: composition fluctuations described by the Ornstein–Zernike equation at low wavenumber Q, and nanostructure modeled by a “pre-peak” at intermediate Q. The former contains information about the thermodynamics of demixing, while the latter reflects nanoscopic self-assembly of the extractant and extracted solutes. While fluctuations have typically not been considered in the literature, we find they in fact dominate the total structure for nearly all practical conditions. As only the fluctuations have a strong temperature response, we confirm this attribution with temperature-dependent SAXS measurements, including for extracted europium nitrate complexes. SAXS and XPCS measurements near the critical point find static and dynamic scaling consistent with theory. Overall, this new paradigm for understanding LLE organic phases connects composition, nanoscale, and mesoscale structuring to phase behavior, providing both a comprehensive picture of solution structure and a quantitative link between aggregation and third phase formation.

Peroutka, Allison A. [Argonne National Laboratory ↗

Influence of helium bubbles on the bulk equation of state of gold under static compression

Nuclear materials often evolve into two-phase systems comprising a bulk matrix with dispersed inert-gas bubbles. The presence of these bubbles can have consequences to the thermomechanical response of materials and is a key life-limiting factor in some nuclear fuel forms. Understanding the behavior of these two-phase, bubble-matrix systems is, thus, important to improved predictive models and frameworks for many nuclear materials applications. While temperature excursions of these two-phase systems have been characterized, fewer studies have focused on the evolution of inert-gas bubbles under pressure. Here, in this paper, we use x-ray tools to interrogate a He-implanted gold foil to determine the pressure-dependent evolution of the individual components (Au matrix + bubbles), and we compare that total pressure dependence to theoretical equation-of-state descriptions based on mixing rules.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗