Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner

Purpose: In this study, newly formulated XR-RV3 GafChromic film was calibrated with National Institute of Standards and Technology (NIST) traceability for measurement of patient skin dose during fluoroscopically guided interventional procedures. Methods: The film was calibrated free-in-air to air kerma levels between 15 and 1100 cGy using four moderately filtered x-ray beam qualities (60, 80, 100, and 120 kVp). The calibration films were scanned with a commercial flatbed document scanner. Film reflective density-to-air kerma calibration curves were constructed for each beam quality, with both the orange and white sides facing the x-ray source. A method to correct for nonuniformity in scanner response (up to 25% depending on position) was developed to enable dose measurement with large films. The response of XR-RV3 film under patient backscattering conditions was examined using on-phantom film exposures and Monte Carlo simulations. Results: The response of XR-RV3 film to a given air kerma depended on kVp and film orientation. For a 200 cGy air kerma exposure with the orange side of the film facing the source, the film response increased by 20% from 60 to 120 kVp. At 500 cGy, the increase was 12%. When 500 cGy exposures were performed with the white side facing the x-ray source, the film response increased by 4.0% (60 kVp) to 9.9% (120 kVp) compared to the orange-facing orientation. On-phantom film measurements and Monte Carlo simulations show that using a NIST-traceable free-in-air calibration curve to determine air kerma in the presence of backscatter results in an error from 2% up to 8% depending on beam quality. The combined uncertainty in the air kerma measurement from the calibration curves and scanner nonuniformity correction was {+-}7.1% (95% C.I.). The film showed notable stability. Calibrations of film and scanner separated by 1 yr differed by 1.0%. Conclusions: XR-RV3 radiochromic film response to a given air kerma shows dependence on beam quality and film orientation. The presence of backscatter slightly modifies the x-ray energy spectrum; however, the increase in film response can be attributed primarily to the increase in total photon fluence at the sensitive layer. Film calibration curves created under free-in-air conditions may be used to measure dose from fluoroscopic quality x-ray beams, including patient backscatter with an error less than the uncertainty of the calibration in most cases.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of calibration curves and energy dependence GafChromic{sup TM} XR-QA2 model based radiochromic film dosimetry system

Purpose: The authors investigated the energy response of XR-QA2 GafChromic{sup TM} film over a broad energy range used in diagnostic radiology examinations. The authors also made an assessment of the most suitable functions for both reference and relative dose measurements. Methods: Pieces of XR-QA2 film were irradiated to nine different values of air kerma in air, following reference calibration of a number of beam qualities ranging in HVLs from 0.16 to 8.25 mm Al, which corresponds to effective energy range from 12.7 keV to 56.3 keV. For each beam quality, the authors tested three functional forms (rational, linear exponential, and power) to assess the most suitable function by fitting the delivered air kerma in air as a function of film response in terms of reflectance change. The authors also introduced and tested a new parameterχ = netΔR·e{sup m} {sup netΔR} that linearizes the inherently nonlinear response of the film. Results: The authors have found that in the energy range investigated, the response of the XR-QA2 based radiochromic film dosimetry system ranges from 0.222 to 0.420 in terms of netΔR at K{sub air}{sup air} = 8 cGy. For beam qualities commonly used in CT scanners (4.03–8.25 mm Al), the variation in film response (netΔR at K{sub air}{sup air} = 8 cGy) amounts to ± 5%, while variation in K{sub air}{sup air} amounts to ± 14%. Conclusions: Results of our investigation revealed that the use of XR-QA2 GafChromic{sup TM} film is accompanied by a rather pronounced energy dependent response for beam qualities used for x-ray based diagnostic imaging purposes. The authors also found that the most appropriate function for the reference radiochromic film dosimetry would be the power function, while for the relative dosimetry one may use the exponential response function that can be easily linearized.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-271: A Feasibility Study to Utilize XR-QA2 Radiochromic Films as An Alternative Tool for Measuring Beam Parameters of Kilovoltage CBCT Systems

Purpose: The beam parameters of the x-ray beams used in image guidance are difficult to measure in water due to the low exposure. This study is to investigate if XR-QA2 radiochromic films can be used in obtaining beam parameters, such as beam profiles and outputs for kV-CBCT systems. Methods: The kV-CBCT beams were from a Varian OBI system. The films used were XR-QA2-GAFCHROMICTM films placed in the middle of two Plastic -Water slab phantoms at isocenter. The scanner used to analyze the films was an Epson Expression 1680 flat-bed scanner. Pre and 24 h-post-irradiated scans of films were obtained by using the reflective mode. The corresponding pixel-by-pixel dose in the films was obtained using a dose calibration equation as a function of net reflectance from the literature. Beam profiles of different scan protocols with and without bow-tie filters were measured. Monte Carlo simulations were used to compare the accuracy of the measured dose profiles. Results: The beam profiles measured from XR-QA2 films for different clinical default kV-CBCT scan protocols were benchmarked against Monte Carlo simulated profiles which have been validated by measurements performed in water phantom. We confirmed that a minimum post-irradiated time of 24 hours is necessary to pass to scan the films to account for light scatter stability. We found that the uncertainties of the results depend on the scan orientation of the film when analyzed in different directions. Conclusion: The XR-QA2 radiochromic films are sensitive to measure the x-ray beam profiles with irradiated dose ranging 1–5 cGy. The film measurements can be performed with an easy setup compared to ion chamber measurements in a water phantom. These films provide an alternative method to obtain the beam profiles for kV-CBCT beams.

60 APPLIED LIFE SCIENCES↗

A reanalysis of the orbital inclination of Cygnus XR-1 determined polarimetrically

The orbital inclination of the Cyg XR-1/HDE 226868 system was determined by Dolan and Tapia (1989) to be 62 deg (+5 deg, -37 deg) from polarimetric observations. Together with the spectroscopic mass function of the binary, this corresponds to a mass of 6.3 solar masses for the X-ray source. Numerical simulations show that there is no straightforward way to removing tidal deformation polarization (TDP) from polarimetric observations of close binaries. A reanalysis of the data shows that the existence of TDP in the Stokes parameter light curves observed from Cyg XR-1 does not significantly bias the mass derived to larger values. The mass of Cyg XR-1 must be significantly larger than 5 solar masses. This fact alone does not require Cyg XR-1 to be a black hole, however. Recent theoretical investigations of possible equations of state of matter at nuclear density show that the maximum mass of a compact object which is not a black hole may be much greater than 5 solar masses.

Dolan, Joseph F.↗

Numerical Simulations of the XR-5 Hall Thruster for Life Assessment at Different Operating Conditions

NASA's Jet Propulsion Laboratory has been investigating the applicability of Aerojet Rocketdyne's XR-5 thruster, a 4.5 kW class Hall thruster, for deep-space missions. Major considerations for qualifying the XR-5 for deep-space missions are demonstration of a wide throttling envelope and a usable life capability in excess of 10,000 h. Numerical simulations with the 2-D axisymmetric code Hall2De are employed to inform the qualification process by assessing erosion rates at the thruster surfaces in a wide range of throttling conditions without the need for conducting costly endurance testing. In previous work at JPL by Jorns et al., the anomalous collision frequency distribution for 11 different throttling conditions of the XR-5 spanning 0.3-4.5 kW were identified based on probe measurements of the electron temperature in the near plume region. In this paper, we provide estimates for the erosion rates at the channel walls and pole covers for the same 11 conditions. Uncertainties in the plasma measurements and in the anomalous collision frequency distribution are addressed by determining upper and lower bounds of the erosion rates. Results suggest that erosion of the walls only occurs in the last 5% of the acceleration channel and the rate of such erosion decreases as the geometry of the thruster changes in time due to magnetic shielding. A quasi-zero-erosion state is eventually achieved in all the examined throttling conditions. Examination of the results for pole surface erosion and estimated cathode life indicates that the XR-5 propellant throughput capability will exceed 700 kg, which provides 50% margin over the usable throughput capability of 466 kg as already demonstrated in wear testing.

Lopez Ortega, Alejandro↗

Pathfinding for Airspace with Autonomous Vehicles (PAAV) ACAS Xr Terminal Area Simulation Overview

This presentation provides an overview of an upcoming human-in-the-loop simulation planned by the Pathfinding for Airspace with Autonomous Vehicles (PAAV) subproject, as part of the Air Traffic Management eXploration project. The study will investigate Detect and Avoid (DAA) concepts in and around the DAA terminal area (DTA). The DTA has received little investigation in real-time, pilot-in-the-loop simulation. This study proposes to use current remotely piloted aircraft system (RPAS) pilots to investigate the effectiveness of current DTA requirements using the FAA's Airborne Collision Avoidance System X for Rotorcraft (ACAS Xr) as the DAA system under test. The findings of this stufy will be used to inform DTA and ACAS Xr standards development. This presentation will be provided to RTCA Special Committee 228 as an overview and as an opportunity to collect feedback from the larger RPAS/DAA community on the study design and key scenarios and metrics. The presentation provides a brief overview of open areas of research with ACAS Xr, the experimental design, the simulation environment and the simulation schedule.

advanced air mobility↗

Characteristics of Gafchromic XR-RV2 radiochromic film

Gafchromic XR-RV2 is a revised version of the obsolete Gafchromic XR-R-type radiochromic film. This article investigates the dose response, energy response, postexposure growth, and polarizing effects of this film after exposure to ionizing radiation in the diagnostic energy range. The effect of bit depth on scanning was also investigated. Films were scanned using an Epson Expression 10000XL document scanner or an X-Rite model 301 spot densitometer. Color channel analysis was performed. The film showed usable response in the air kerma range of 1-1000 cGy, although by 1500 cGy the film appeared saturated when using the red color channel on a document scanner. The film response varied by 11% between 60 and 96 kVp and 3.5% between 96 and 125 kVp for doses above 1 Gy. Postexposure growth was found to be approximately logarithmic and fairly stable after 24 h. Films stored under office lighting exhibited around twice the density growth compared with film stored in a dark environment. The film showed strong orientation dependence when scanned using a polarized light source. A 48 bit scan provided no increase in sensitivity over 24 bits. Gafchromic XR-RV2 film is a radiochromic film ideally suited for measurement of wide dose ranges at diagnostic energies. The energy dependence of this film limits its accuracy for dosimetry of unknown energy beams. For the document scanners used in this study a 24 bit scan was more than sufficient compared to a 48 bit scan. This is likely to be the case for most document scanners where electrical noise prevents higher bit depths from increasing the sensitivity of measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Possible Evidence for an Event Horizon in Cyg XR-1

The X-ray emitting component in the Cyg XR-1/HDE226868 system is a leading candidate for identification as a stellar-mass sized black hole. The positive identification of a black hole as predicted by general relativity requires the detection of an event horizon surrounding the point singularity. One signature of such an event horizon would be the existence of dying pulse trains emitted by material spiraling into the event horizon from the last stable orbit around the black hole. We observed the Cyg XR-1 system at three different epochs in a 1400 - 3000 A bandpass with 0.1 ms time resolution using the Hubble Space Telescope's High Speed Photometer. Repeated excursions of the detected flux by more than three standard deviations above the mean are present in the UV flux with FWHM 1 - 10 ms. If any of these excursions are pulses of radiation produced in the system (and not just stochastic variability associated with the Poisson distribution of detected photon arrival times), then this short a timescale requires that the pulses originate in the accretion disk around Cyg XR-1. Two series of pulses with characteristics similar to those expected from dying pulse trains were detected in three hours of observation.

Dolan, Joseph F.↗

Dying Pulse Trains in Cygnus XR-1: Initial Results of X-Ray Searches

Dying pulse trains (DPT's) are a signature of a black hole as described by general relativity. Detecting DPT's would establish the existence of black holes by ruling out more exotic objects in systems in which a neutron star or white dwarf component has already been excluded by maximum mass arguments. The positive identification of a black hole would also be an additional test of general relativity. Two possible DPT's were detected in W photometry of Cygnus XR-1, the leading candidate for a stellar mass sized BH, in 3 hours of observational data. A search of X-ray photometry of Cygnus XR-1 from the Ross1 X-ray Timing Explorer (RXTE) has begun. No DPT's have been detected in the first 4 hours of data searched. Because of the low event rate detected in the W data, these initial results are consistent with such disparate scenarios as the rate of DPT occurrence being dependent on the luminosity state of the system; or being more difficult to detect in the X-ray region relative to the W region; or occurring at the same rate in the W and X-ray regions; or even not occurring at all from Cygnus XR-1. The search for DPT's in RXTE photometry is continuing.

Dolan, Joseph F.↗

Characterization of GafChromic XR-RV2 film and comparator strip using a flatbed scanner in reflection mode

Interventional cardiology procedures are an effective alternative for the reestablishment of correct sanguineous circulation in the heart. However, this kind of procedures exposes to the patients to a relatively high radiation doses. Usually, the surface peak skin dose is evaluated using a visual scale with a comparator strip, nevertheless, even if the comparator strip provides a simple and quick method for estimating the dose it has an uncertainty of {+-}25%. For this reason, a better evaluation method is needed. The objective of our project is to determine the surface peak skin dose of interventional cardiology procedures using GafChromic XR-RV2 film together with a commercial flatbed scanner in reflection mode. Here we report a protocol to handle GafChromic XR-RV2 film using a commercial flat bed scanner in reflection mode aiming at an uncertainty of {+-}3%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reference dosimetry during diagnostic CT examination using XR-QA radiochromic film model

Purpose: The authors applied 2D reference dosimetry protocol for dose measurements using XR-QA radiochromic film model during diagnostic computed tomography (CT) examinations carried out on patients and humanoid Rando phantom. Methods: Response of XR-QA model GAFCHROMIC film reference dosimetry system was calibrated in terms of Air-Kerma in air. Four most commonly used CT protocols were selected on their CT scanner (GE Lightspeed VCT 64), covering three anatomical sites (head, chest, and abdomen). For each protocol, 25 patients ongoing planned diagnostic CT examination were recruited. Surface dose was measured using four or eight film strips taped on patients' skin and on Rando phantom. Film pieces were scanned prior to and after irradiation using Epson Expression 10000XL document scanner. Optical reflectance of the unexposed film piece was subtracted from exposed one to obtain final net reflectance change, which is subsequently converted to dose using previously established calibration curves. Results: The authors' measurements show that body skin dose variation has a sinusoidal pattern along the scanning axis due to the helical movement of the x-ray tube, and a comb pattern for head dose measurements due to its axial movement. Results show that the mean skin dose at anterior position for patients is (51 {+-} 6) mGy, (29 {+-} 11) mGy, (45 {+-} 13) mGy and (38 {+-} 20) mGy for head, abdomen, angio Abdomen, and chest and abdomen protocol (UP position), respectively. The obtained experimental dose length products (DLP) show higher values than CT based DLP taken from the scanner console for body protocols, but lower values for the head protocol. Internal dose measurements inside the phantom's head indicate nonuniformity of dose distribution within scanned volume. Conclusions: In this work, the authors applied an Air-Kerma in air based radiochromic film reference dosimetry protocol for in vivo skin dose measurements. In this work, they employed green channel extracted from the scanned RGB image for dose measurements in the range from 0 to 200 mGy. Measured skin doses and corresponding DLPs were higher than DLPs provided by the CT scanner manufacturer as they were measured on patients' skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ionospheric effects of X-ray source Scorpius XR-1

A simple two-ion model was employed to evaluate the ionospheric effects of various nocturnal ionization sources. The model was used to calculate the decay of the electron number density at 90 km with and without illumination by Scorpius XR-1 X rays. Reflection parameters for the determination of the effect of cosmic x-ray sources on radio wave propagation were also obtained. The results obtained in the investigation do not support the proposal made by Anathakrishnan and Ramanathan (1969) that the X-ray source in Scorpius XR-1 affects the nighttime lower ionosphere of the earth.

Poppoff, I. G.↗

Intensity transitions in Cyg XR-1 observed at high energies from OSO 8

The observed transitions at energies above 20 keV show that the spectrum of Cyg XR-1 exhibits the pivoting effect during intensity transitions expected from two-temperature accretion disk models of the X-ray emitting region. Cyg XR-1 was observed with the high-energy X-ray spectrometer on board the OSO-8 satellite from November 11-19, 1975 and from October 27 to November 15, 1976 (excluding the period from November 1 to November 7, 1976).

Dolan, J. F.↗

The high-energy X-ray spectrum of Centaurus XR-3 observed from OSO 8

Observations of the X-ray binary Cen XR-3 in the 20-120 keV energy range by means of OSO 8's high energy X-ray spectrometer, during July 16-19, 1975, and July 5-14 and 28-29, 1978, indicate that the source was in a high luminosity state during 1975 and a low luminosity one in 1978. While mean orbital light curves appear similar in shape in both years, orbit-to-orbit intensity variations are noted. Spectral, luminosity, and the 4.84 sec modulation are characterized. Cen XR-3 may be a system in which mass transfer by Roche lobe overflow, and by accretion from a stellar wind, are both effective in the production of observable X-ray radiation.

Dolan, J. F.↗

Using XR for Improving Scientific Discovery With Numerical Weather Models

Our work explores the use of extended reality (XR) to im- prove scientific discovery with numerical weather/climate models that inform Earth science digital twins, specifically the NASA Goddard Earth Observing System (GEOS) global atmospheric model. The overall project is named the Vi- sualization And Lagrangian dynamics Immersive eXtended Reality Toolkit (VALIXR), which has two main areas of focus: (1) enhancing the understanding of and interaction with model output data through advanced visualizations in the XR environment, and (2) the integration of Lagrangian dynamics into the GEOS model, which allows a natural, feature-specific analysis of Earth science phenomena as op- posed to traditional, fixed-point Eulerian dynamics. Here, we report initial work on these focus areas.

Thomas Grubb↗

Probing the Electronic Structures of [Cmu(Mu-XR(2)]**N+ Diamond Cores As a Function of the Bridging X Atom (X = N Or P) And Charge (N=0, 1, 2)

A series of dicopper diamond core complexes that can be isolated in three different oxidation states ([Cu{sub 2}({mu}-XR{sub 2})]{sup n+}, where n = 0, 1, 2 and X = N or P) is described. Of particular interest is the relative degree of oxidation of the respective copper centers and the bridging XR{sub 2} units, upon successive oxidations. These dicopper complexes feature terminal phosphine and either bridging amido or phosphido donors, and as such their metal-ligand bonds are highly covalent. Cu K-edge, Cu L-edge, and P K-edge spectroscopies, in combination with solid-state X-ray structures and DFT calculations, provides a complementary electronic structure picture for the entire set of complexes that tracks the involvement of a majority of ligand-based redox chemistry. The electronic structure picture that emerges for these inorganic dicopper diamond cores shares similarities with the Cu{sub 2}({mu}-SR){sub 2} Cu{sub A} sites of cytochrome c oxidases and nitrous oxide reductases.

59 BASIC BIOLOGICAL SCIENCES↗

Deploying Extended Reality (XR) for Digital Operations and Maintenance (O&M) at the Mechanisms Engineering Test Loop (METL)

This report documents the preliminary efforts to digitize operation and maintenance (O&M) activities for the Mechanisms Engineering Test Loop (METL). METL became operational in September 2018 with the mission to provide an ecosystem for Advanced Reactor Development (ARD). METLs flagship facility’s primary purpose is conducting small to intermediate scale tests for Sodium Fast Reactors (SFR). Its resemblance to commercial SFR’s intermediate heat transport system, prototypic operating conditions, and industrial construction practices/materials provides the overarching benefit of establishing a proving ground for emerging operations and maintenance (O&M) activities such as incorporating Extended Reality (XR) applications throughout the program lifecycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ACAS Xr Part Task Sim, Preliminary Experiment Design

In early 2022, the Human Autonomy Teaming Lab (NASA Ames Research Center) will conduct a manned, human-in-the-loop (HITL) simulation. This part task HITL will begin the lab’s Hazard Perception and Avoidance (HPA) technical work under NASA’s Advanced Air Mobility (AAM), Automated Flight and Contingency Management (AFCM) Sub-Project. The goals will be to assess levels of automation for manned, electric vertical takeoff and landing (eVTOL) aircraft. This simulation will test manual and automated Resolution Advisory (RA) responses and return-to-course (RTC) maneuvers for the first version of the Airborne Collision Avoidance System’s (ACAS) rotary-wing (Xr) variant. This will be conducted on a fixed-based simulator designed to fly eVTOL aircraft while maneuvering for intruding traffic. Variables for this study include levels of autonomy (i.e., manual and automated) as well as the types of alerts at the onset of conflicts (i.e., Corrective and RA). The data collected will include response times, losses of well clear, and maneuver sizes and durations as well as subjective ratings like acceptability, perceived workload, and meaningful human control. Additional details and future anticipations are also discussed.

air taxis↗