Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multidiagnostic analysis of ion dynamics in ultrafast laser ablation of metals over a large fluence range

The dynamics of ions in ultrafast laser ablation of metals is studied over fluences ranging from the ablation threshold up to ≈75 J/cm{sup 2} by means of three well-established diagnostic techniques. Langmuir probe, Faraday cup, and spectrally resolved intensified charge coupled device imaging simultaneously monitored the ions produced during ultrafast laser ablation of a pure copper target with 800 nm, ≈50 fs, Ti: Sapphire laser pulses. The fluence dependence of ion yield is analyzed, resulting in the observance of three different regimes. The specific ion yield shows a maximum at about 4–5 J/cm{sup 2}, followed by a gradual reduction and a transition to a high-fluence regime above ≈50 J/cm{sup 2}. The fluence dependence of the copper ions angular distribution is also analyzed, observing a gradual increase in forward-peaking of Cu ions for fluences up to ≈10 J/cm{sup 2}. A broader ion component is observed at larger angles for fluences larger than ≈10 J/cm{sup 2}. Finally, an experimental characterization of the ionic angular distribution for several metallic targets (Mg, Al, Cr, Fe, Cu, and W) is carried out at a relatively high fluence of ≈66 J/cm{sup 2}. Interestingly, the ion emission from the volatile metals shows a narrow, forward-peaked distribution, and a high peak ion yield compared to the refractory metals. Moreover, the width of ionic angular distributions presents a striking correlation with the peak ion yield.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional single-mode nonlinear ablative Rayleigh-Taylor instability

The nonlinear evolution of the single-mode ablative Rayleigh-Taylor instability is studied in three dimensions. As the mode wavelength approaches the cutoff of the linear spectrum (short-wavelength modes), it is found that the three-dimensional (3D) terminal bubble velocity greatly exceeds both the two-dimensional (2D) value and the classical 3D bubble velocity. Unlike in 2D, the 3D short-wavelength bubble velocity does not saturate. The growing 3D bubble acceleration is driven by the unbounded accumulation of vorticity inside the bubble. The vorticity is transferred by mass ablation from the Rayleigh-Taylor spikes to the ablated plasma filling the bubble volume.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Percutaneous Renal Tumor Ablation: Radiation Exposure During Cryoablation and Radiofrequency Ablation

IntroductionOnce reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues.Materials and MethodsRetrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique.ResultsFor the 331 cryoablation procedures, the mean DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDI{sub vol} was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDI{sub vol} was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001).ConclusionBoth cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Weakly nonlinear ablative Rayleigh-Taylor instability at preheated ablation front

Stuart's weakly nonlinear theory is generalized to study single-mode ablative Rayleigh-Taylor instability (ARTI) at a broad ablation front caused by preheating. The thickness effect of the ablation front is considered and the spatial amplitude distributions of density, temperature, and velocity for harmonic modes are obtained in the present model. It is confirmed that the modified Lindl formula [W. H. Ye et al., Phys. Rev. E 65, 057401 (2002)] is valid for predicting the linear growth rate when the ablation front is broad. It is shown by the present model that the mass ablation of the shell is enhanced obviously due to the generation of harmonics while the harmonics' effect on the mass asymmetry of the shell is weaker than the expectation given by the classical theory. It is also indicated by the present model that ARTI is stabilized by the nonlinear correction for all modes. This conclusion is physical and different from the sharp boundary model where ARTI is enhanced by the nonlinear correction for the short wavelength case. The reason for this difference is due to the thickness effect of the ablation front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigations of ablation stream interaction dynamics in tungsten wire arrays: Interpenetration, magnetic field advection, and ion deflection

Experiments have been carried out to investigate the collisional dynamics of ablation streams produced by cylindrical wire array z-pinches. A combination of laser interferometric imaging, Thomson scattering, and Faraday rotation imaging has been used to make a range of measurements of the temporal evolution of various plasma and flow parameters. This paper presents a summary of previously published data, drawing together a range of different measurements in order to give an overview of the key results. The paper focuses mainly on the results of experiments with tungsten wire arrays. Early interferometric imaging measurements are reviewed, then more recent Thomson scattering measurements are discussed; these measurements provided the first direct evidence of ablation stream interpenetration in a wire array experiment. Combining the data from these experiments gives a view of the temporal evolution of the tungsten stream collisional dynamics. In the final part of the paper, we present new experimental measurements made using an imaging Faraday rotation diagnostic. These experiments investigated the structure of magnetic fields near the array axis directly; the presence of a magnetic field has previously been inferred based on Thomson scattering measurements of ion deflection near the array axis. Although the Thomson and Faraday measurements are not in full quantitative agreement, the Faraday data do qualitatively supports the conjecture that the observed deflections are induced by a static toroidal magnetic field, which has been advected to the array axis by the ablation streams. It is likely that detailed modeling will be needed in order to fully understand the dynamics observed in the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implosion Experiments using Glass Ablators for Direct-Drive Inertial Confinement Fusion

Direct-drive implosions with 20-{mu}m-thick glass shells were conducted on the Omega Laser Facility to test the performance of high-Z glass ablators for direct-drive, inertial confinement fusion. The x-ray signal caused by hot electrons generated by two-plasmon-decay instability was reduced by more than {approx}40x and hot-electron temperature by {approx}2x in the glass compared to plastic ablators at ignition-relevant drive intensities of {approx}1x10{sup 15} W/cm{sup 2}, suggesting reduced target preheat. The measured absorption and compression were close to 1D predictions. The measured soft x-ray production in the spectral range of {approx}2 to 4 keV was {approx}2x to 3x lower than 1D predictions, indicating that the shell preheat caused by soft x-rays is less than predicted. A direct-drive-ignition design based on glass ablators is introduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids

Purpose: To report the first clinical experience with targeted vessel ablation during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic uterine fibroids. Methods: Pretreatment T1-weighted contrast-enhanced magnetic resonance angiography was used to create a detailed map of the uterine arteries and feeding branches to the fibroids. A three-dimensional overlay of the magnetic resonance angiography images was registered on 3D T2-weighted pretreatment imaging data. Treatment was focused primarily on locations where supplying vessels entered the fibroid. Patients were followed 6 months after treatment with a questionnaire to assess symptoms and quality of life (Uterine Fibroid Symptom and Quality of Life) and magnetic resonance imaging to quantify shrinkage of fibroid volumes. Results: In two patients, three fibroids were treated with targeted vessel ablation during MR-HIFU. The treatments resulted in almost total fibroid devascularization with nonperfused volume to total fibroid volume ratios of 84, 68, and 86%, respectively, of treated fibroids. The predicted ablated volumes during MR-HIFU in patients 1 and 2 were 45, 40, and 82 ml, respectively, while the nonperfused volumes determined immediately after treatment were 195, 92, and 190 ml respectively, which is 4.3 (patient 1) and 2.3 (patient 2) times higher than expected based on the thermal dose distribution. Fibroid-related symptoms reduced after treatment, and quality of life improved. Fibroid volume reduction ranged 31-59% at 6 months after treatment. Conclusion: Targeted vessel ablation during MR-HIFU allowed nearly complete fibroid ablation in both patients. This technique may enhance the use of MR-HIFU for fibroid treatment in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plastic ablator ignition capsule design for the National Ignition Facility

The National Ignition Campaign, tasked with designing and fielding targets for fusion ignition experiments on the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Nucl. Fusion 44, S228 (2004)], has carried forward three complementary target designs for the past several years: a beryllium ablator design, a plastic ablator design, and a high-density carbon or synthetic diamond design. This paper describes current simulations and design optimization to develop the plastic ablator capsule design as a candidate for the first ignition attempt on NIF. The trade-offs in capsule scale and laser energy that must be made to achieve a comparable ignition probability to that with beryllium are emphasized. Large numbers of one-dimensional simulations, meant to assess the statistical behavior of the target design, as well as two-dimensional simulations to assess the target's susceptibility to Rayleigh-Taylor growth are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Early plume and shock wave dynamics in atmospheric-pressure ultraviolet-laser ablation of different matrix-assisted laser ablation matrices

Pulsed laser ablation of molecular solids is important for identification and quantification in (bio-)organic mass spectrometry, for example using matrix-assisted laser desorption/ionization (MALDI). Recently, there has been a major shift to using MALDI and related laser ablation/post-ionization methods at atmospheric pressure. However, the underlying laser ablation processes, in particular early plume formation and expansion, are still poorly understood. Here, we present a study of the early ablation processes on the ns-time scale in atmospheric pressure UV-laser ablation of anthracene as well as of different common MALDI matrices such as 2,5-dihydroxybenzoic acid (2,5-DHB), {alpha}-cyano-4-hydroxycinnamic acid and sinapinic acid. Material release as well as the formation and expansion of hemi-spherical shock waves were studied by shadowgraphy with high temporal resolution ({approx}5 ns). The applicability of the classical Taylor-Sedov model for expansion of strong shock waves ('point-blast model'), as well as the drag force model, were evaluated to mathematically describe the observed shock wave propagation. The time- and energy-dependent expansion of the shock waves could be described using a Taylor-Sedov scaling law of the form R {proportional_to} t{sup q}, when a q-exponent of {approx}0.5 instead of the theoretical value of q 0.4 was found, indicating a faster expansion than expected. The deviations from the ideal value of q were attributed to the non-negligible influence of ambient pressure, a weak versus strong shock regime, and additional acceleration processes present in laser ablation that surpass the limit of the point-blast model. The onset of shock wave formation at a fluence of {approx}15-30 mJ/cm{sup 2} for the compounds investigated coincides with the onset of bulk material release, whereas, pure desorption below this fluence threshold did not lead to features visible in shadowgraphy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ablation enhancement of silicon by ultrashort double-pulse laser ablation

In this study, the ultrashort double-pulse ablation of silicon is investigated. An atomistic simulation model is developed to analyze the underlying physics. It is revealed that the double-pulse ablation could significantly increase the ablation rate of silicon, compared with the single pulse ablation with the same total pulse energy, which is totally different from the case of metals. In the long pulse delay range (over 1 ps), the enhancement is caused by the metallic transition of melted silicon with the corresponding absorption efficiency. At ultrashort pulse delay (below 1 ps), the enhancement is due to the electron excitation by the first pulse. The enhancement only occurs at low and moderate laser fluence. The ablation is suppressed at high fluence due to the strong plasma shielding effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ablation of high-Z material dust grains in edge plasmas of magnetic fusion devices

The model, including shielding effects of high-Z dust grain ablation in tokamak edge plasma, is presented. In a contrast to shielding models developed for pellets ablation in a hot plasma core, this model deals with the dust grain ablation in relatively cold edge plasma. Using some simplifications, a closed set of equations determining the grain ablation rate Γ is derived and analyzed both analytically and numerically. The scaling law for Γ versus grain radius and ambient plasma parameters is obtained and confirmed by the results of numerical solutions. The results obtained are compared with both dust grain models containing no shielding effects and the pellet ablation models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond ultraviolet laser ablation of silver and comparison with nanosecond ablation

The ablation plume dynamics arising from ablation of silver with a 500 fs, 248 nm laser at {approx}2 J cm{sup -2} has been studied using angle-resolved Langmuir ion probe and thin film deposition techniques. For the same laser fluence, the time-of-flight ion signals from femtosecond and nanosecond laser ablation are similar; both show a singly peaked time-of-flight distribution. The angular distribution of ion emission and the deposition are well described by the adiabatic and isentropic model of plume expansion, though distributions for femtosecond ablation are significantly narrower. In this laser fluence regime, the energy efficiency of mass ablation is higher for femtosecond pulses than for nanosecond pulses, but the ion production efficiency is lower.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic-field generation and its effect on ablative Rayleigh–Taylor instability in diffusive ablation fronts

The effects of self-generated magnetic fields on the ablative Rayleigh–Taylor (RT) instability are investigated in the linear regime. The main governing parameters are the Froude number (Fr), which stands for the ratio between ablative convection and acceleration of the target, and the Mach number at the ablation front (Ma), assumed to be small (isobaricity). During the development of the RT instability, magnetic fields are generated due to misalignment between pressure and density gradients (Biermann-battery effect). They accumulate at the section of the ablation front where the Nernst and the plasma velocities cancel each other. The magnetic field modifies the dynamics of the instability through the Righi–Leduc term, which acts as a heat source in the energy equation. It is found that the B fields affect perturbations with short wavelengths up to the most unstable wave in the spectrum. Here, the B field plays a destabilizing role for moderate Froude numbers and becomes stabilizing for large Froude numbers. For plastic ablators, the Fr threshold is found to be Fr = 5.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Momentum Transfer by Laser Ablation of Irregularly Shaped Space Debris

Proposals for ground-based laser remediation of space debris rely on the creation of appropriately directed ablation-driven impulses to either divert the fragment or drive it into an orbit with a perigee allowing atmospheric capture. For a spherical fragment, the ablation impulse is a function of the orbital parameters and the laser engagement angle. If, however, the target is irregularly shaped and arbitrarily oriented, new impulse effects come into play. Here we present an analysis of some of these effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional fluorescence spectroscopy of uranium isotopes in femtosecond laser ablation plumes

Here, we demonstrate measurement of uranium isotopes in femtosecond laser ablation plumes using two-dimensional fluorescence spectroscopy (2DFS). The high-resolution, tunable CW-laser spectroscopy technique clearly distinguishes atomic absorption from 235 U and 238 U in natural and highly enriched uranium metal samples. We present analysis of spectral resolution and analytical performance of 2DFS as a function of ambient pressure. Simultaneous measurement using time-resolved absorption spectroscopy provides information on temporal dynamics of the laser ablation plume and saturation behavior of fluorescence signals. The rapid, non-contact measurement is promising for in-field, standoff measurements of uranium enrichment for nuclear safety and security.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Streaked radiography measurements of convergent ablator performance (invited)

The velocity and remaining ablator mass of an imploding capsule are critical metrics for assessing the progress toward ignition of an inertially confined fusion experiment. These and other ablator rocket parameters have been measured using a single streaked x-ray radiograph. A regularization technique has been used to determine the ablator density profile {rho}(r) at each time step; moments of {rho}(r) then provide the areal density, average radius, and mass of the unablated, or remaining, ablator material, with the velocity determined from the time derivative of the average radius. The technique has been implemented on experiments at the OMEGA laser facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of areal density in the ablators of inertial-confinement-fusion capsules via detection of ablator (n, n Prime {gamma}) gamma-ray emission

We report the first gamma-ray-based measurements of the areal density of ablators in inertial-confinement-fusion capsule implosions. The measurements, made at the OMEGA laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], used observations of gamma rays arising from inelastic scattering of 14.1-MeV deuterium-tritium (DT) neutrons on {sup 12}C nuclei in the compressed plastic ablators. The emission of {sup 12}C(n,n Prime {gamma}) gamma rays from the capsules is detected using the Gamma Reaction History instrument [H. W. Herrmann et al., J. Phys.: Conf. Ser. 244, 032047 (2010)] operating at OMEGA. From the ratio of a capsule's {sup 12}C(n,n Prime {gamma}) emission to the emission from the same processes in an in situ reference graphite 'puck' of known mass and geometry [N. M. Hoffman et al., in IFSA 2011 proceedings (submitted)], we determine the time-averaged areal density of {sup 12}C in the capsule's compressed ablator. Measured values of total ablator areal density for thirteen imploded capsules, in the range 23 {+-} 10 to 58 {+-} 14 mg/cm{sup 2}, are comparable to values calculated in 1D radiation-hydrodynamic simulations, and measured by charged-particle techniques.

36 MATERIALS SCIENCE↗

A survey of pulse shape options for a revised plastic ablator ignition design

Recent experimental results using the “high foot” pulse shape for inertial confinement fusion ignition experiments on the National Ignition Facility (NIF) [Moses et al., Phys. Plasmas 16, 041006 (2009)] have shown encouraging progress compared to earlier “low foot” experiments. These results strongly suggest that controlling ablation front instability growth can significantly improve implosion performance even in the presence of persistent, large, low-mode distortions. Simultaneously, hydrodynamic growth radiography experiments have confirmed that ablation front instability growth is being modeled fairly well in NIF experiments. It is timely then to combine these two results and ask how current ignition pulse shapes could be modified to improve one-dimensional implosion performance while maintaining the stability properties demonstrated with the high foot. This paper presents such a survey of pulse shapes intermediate between the low and high foot extremes in search of an intermediate foot optimum. Of the design space surveyed, it is found that a higher picket version of the low foot pulse shape shows the most promise for improved compression without loss of stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗