Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated stress test (AST)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Durability of Pt-Alloy Catalyst for Heavy-Duty Polymer Electrolyte Fuel Cell Applications under Realistic Conditions

As an emerging technology, polymer electrolyte fuel cells (PEFCs) powered by clean hydrogen can be a great source of renewable power generation with flexible utilization because of high gravimetric energy density of hydrogen. To be used in real-life applications, PEFCs need to maintain their performance for long-term use under a wide range of conditions. Therefore, it's important to understand the degradation of the PEFC under protocols that are closely related to the catalyst lifetime. Alloying Pt with transitional metal improves catalyst activity. It is also crucial to understand Pt alloys degradation mechanisms to improve their durability. To study durability of Pt alloys, accelerated stress tests (ASTs) are performed on Pt-Co catalyst supported on two types of carbon. Two different AST protocols were being studied: Membrane Electrolyte Assembly (MEA) AST based on the protocol introduced by the Million Mile Fuel Cell Truck consortium in 2023 and Catalyst AST, adopted from the U.S. Department of Energy (DoE).

25 ENERGY STORAGE↗

Operando carbon corrosion measurements in fuel cells using boron-doped carbon supports

Carbonaceous materials are the most common catalyst supports in proton exchange membrane fuel cell (PEMFCs), yet their corrosion is one of the limiting factors in achieving high durability. Herein, we doped carbon supports with boron (B) to increase the corrosion-resistance of the support. Two types of B-doped carbons were synthesized and studied as platinum support materials. Further, they varied in their morphologies, surface areas, and the types of boron species. The durability of Pt/B-doped carbon catalysts was investigated using the US-DOE catalysts’ supports accelerated stress test (AST) and a mass-spectrometer connected to the fuel cell effluent stream to quantify the mass of corroded carbon support in operando. The addition of boron to the carbon increased the stability of Pt catalysts in long-term usage of PEMFC. After 4000 AST cycles, more than 50% of initial current density was preserved for the boron-containing systems, while less than 30% of it remained with Vulcan carbon (Pt/V). Also, the Pt/B-doped carbon samples demonstrated better electrochemical active surface area (ECSA) stability when compared to Pt/V. Carbon loss measurements showed that B-doped carbons have higher resistance to electrochemical corrosion than unmodified carbon. Specifically, the substitutional boron-doped carbon demonstrated an extremely high stability and low corrosion rate.

25 ENERGY STORAGE↗

Visualization, understanding, and mitigation of process-induced-membrane irregularities in gas diffusion electrode-based polymer electrolyte membrane fuel cells

Polymer electrolyte membrane fuel cells (PEMFC) show substantial promise for their application in electric vehicles. For large-scale manufacturing of PEMFCs, roll-to-roll coated gas-diffusion-electrodes (GDE) offer certain advantages over other production pathways. Procedures including hot pressing and coating an ionomer overlayer may be necessary for this manufacturing pathway to enable a suitable catalyst layer/membrane interface. The same procedures may potentially introduce membrane irregularities, especially when thin membranes are used. Limited understanding exists regarding if and to what extent such irregularities impact PEMFC performance and lifetime, and therefore be considered defects. In this study, NREL's customized fuel cell hardware that enables quasi in-situ infrared (IR) thermography studies was utilized to visualize spatial hydrogen crossover and identify membrane irregularities that originated from the GDE-based MEA fabrication process. The structure of these membrane irregularities was investigated by scanning electron microscopy (SEM) and its impact on initial H2/air performance was determined. Accelerated stress testing (AST) revealed that these irregularities develop into failure point locations. These results were validated across many MEAs with identified process-induced membrane irregularities. By selecting specific gas diffusion media properties and by fine tuning the MEA hot pressing parameters, the formation of such membrane irregularities was mitigated.

08 HYDROGEN↗

Inverse Consequences of the SnO 2 Protection Layers on Pt/C Catalysts in Proton-Exchange Membrane Fuel Cells

Proton-exchange membrane fuel cells (PEMFCs) are promising energy-conversion systems, offering an appealing blend of high energy efficiency and low environmental impact. However, carbon corrosion of PEMFCs is known to significantly degrade their performance, remaining a critical challenge to overcome. In this study, we applied a Nb-doped SnO 2 (Nb-SnO 2 ) nanoparticle coating on Pt/C catalysts as a protective layer, with the Sn/C ratio in the precursors varying from 0.25:1 to 2.0:1. Contradictory behaviors of the coated Pt/C catalysts were observed at different Sn/C ratios. The Sn/C = 1.0 sample exhibited improved electrochemically active surface area retention after 500 cycles of accelerated stress testing (AST) but with more significant polarization and resistance increase observed in the polarization curves. In addition, agglomeration of Nb-SnO 2 particles was observed at a higher Sn/C ratio in the AST of a membrane electrode assembly, with less shrinkage of the total thickness of the Nb-SnO 2 -coated Pt/C electrode. We speculate that formation of Nb-SnO 2 agglomerates occurs once the protective layer is broken down or the unprotected carbon surface is corroded and that these Nb-SnO 2 agglomerates increase the tortuosity of the electron pathways and significantly increase the cell polarization.

30 DIRECT ENERGY CONVERSION↗

Regulating Catalytic Properties and Thermal Stability of Pt and PtCo Intermetallic Fuel-Cell Catalysts via Strong Coupling Effects between Single-Metal Site-Rich Carbon and Pt

Developing low platinum-group-metal (PGM) catalysts for the oxygen reduction reaction (ORR) in proton-exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles (HDVs) remains a great challenge due to the highly demanded power density and long-term durability. Here, this work explores the possible synergistic effect between single Mn site-rich carbon (Mn SA -NC) and Pt nanoparticles, aiming to improve intrinsic activity and stability of PGM catalysts. Density functional theory (DFT) calculations predicted a strong coupling effect between Pt and MnN 4 sites in the carbon support, strengthening their interactions to immobilize Pt nanoparticles during the ORR. The adjacent MnN 4 sites weaken oxygen adsorption at Pt to enhance intrinsic activity. Well-dispersed Pt (2.1 nm) and ordered L1 2 -Pt 3 Co nanoparticles (3.3 nm) were retained on the Mn SA -NC support after indispensable high-temperature annealing up to 800 °C, suggesting enhanced thermal stability. Both PGM catalysts were thoroughly studied in membrane electrode assemblies (MEAs), showing compelling performance and durability. The Pt@Mn SA -NC catalyst achieved a mass activity (MA) of 0.63 A mg Pt –1 at 0.9 V iR-free and maintained 78% of its initial performance after a 30,000-cycle accelerated stress test (AST). The L1 2 -Pt 3 Co@Mn SA -NC catalyst accomplished a much higher MA of 0.91 A mg Pt –1 and a current density of 1.63 A cm –2 at 0.7 V under traditional light-duty vehicle (LDV) H 2 –air conditions (150 kPa abs and 0.10 mg Pt cm –2 ). Furthermore, the same catalyst in an HDV MEA (250 kPa abs and 0.20 mg Pt cm –2 ) delivered 1.75 A cm –2 at 0.7 V, only losing 18% performance after 90,000 cycles of the AST, demonstrating great potential to meet the DOE targets.

25 ENERGY STORAGE↗

Regulating in situ gaseous deposition to construct highly durable Fe–N–C oxygen-reduction fuel cell catalysts

The activity–stability trade-off challenges the design of high-performance atomically dispersed iron–nitrogen–carbon (Fe–N–C) catalysts for the acidic oxygen reduction reaction in polymer electrolyte fuel cells. Here we develop an in situ chemical vapour deposition approach during catalyst synthesis to break the trade-off, producing highly stable Fe–N–C catalysts while maintaining adequate oxygen reduction reaction activity. The optimal catalyst exhibits a half-wave potential of 0.867 V, remaining unchanged after an accelerated stress test (AST) of 100,000 potential cycles in rotating disk electrode tests. In membrane electrode assemblies under H 2 –air conditions, it delivers 93 mA cm −2 at 0.8 V after a standard AST of 30,000 voltage cycles, and shows minimal current density losses (2.9% at 0.6 V; 14.2% at 0.7 V) after an extended AST up to 120,000 cycles. Furthermore, the catalyst’s durability improvement is primarily due to the in situ chemical vapour deposition, which strengthens Fe–N bonds, increases active-site density, mitigates iron aggregates and reduces surface porosity.

Chemical engineering↗

A low temperature unitized regenerative fuel cell realizing 60% round trip efficiency and 10 000 cycles of durability for energy storage applications

Unitized regenerative fuel cells (URFC) convert electrical energy to and from chemical bonds in hydrogen. URFCs have the potential to provide economical means for efficient long-term, seasonal, energy storage and on-demand conversion back to electrical energy. We first optimize the catalyst layer for discrete electrolyzer and fuel cell and then configure the URFC. The goal is to identify a cost competitive configuration for URFCs, and demonstrate it in terms of upper limit of round trip efficiencies (RTEs). Two possible configurations of URFCs are compared via experiments and techno-economic analysis (TEA), which emphasize the advantages of the unconventional constant-electrode (CE) URFC over the traditional constant-gas (CG) configuration. We also study the stability via accelerated stress tests (ASTs) and demonstrate steady state operation in a daily cycle for day to night energy shifting. From the investigations, the optimum composition of the URFC anode catalyst layer is 90 at% Ir-black balanced by Pt-black for both CE and CG configurations. At 80 °C and 1 A cm -2 , the optimized CE URFC achieves 57% and 60% RTE with air and O 2 as the reductant gases, respectively. We then evaluated the differences in durability using an AST over 10k charge–discharge cycles; the results reveal that the wider potential window at the anode in CE (0.05–1.55 V) has minimal effect on catalyst layer stability compared to CG (0.55–1.55 V). Furthermore, there was no degradation up to the range of 2k–5k cycles; beyond that the fuel cell (discharge) performance degraded while the electrolyzer (charge) performance was still stable. Finally, the observations here indicate substantial potential to employ URFCs as efficient and cost-effective bidirectional energy-conversion devices within energy storage and utilization systems after appropriate technological and operational optimizations.

25 ENERGY STORAGE↗

Correlating the Morphological Changes to Electrochemical Performance During Carbon Corrosion in Polymer Electrolyte Fuel Cells

A mechanistic understanding of carbon corrosion in polymer electrolyte fuel cells (PEFCs) is required to design durable catalyst layers. Uncontrolled startup and shutdown of PEFCs cause electrochemical oxidation of carbon, which leads to several degradation phenomena, such as loss in electrochemical surface area (ECSA), pore structure collapse or increase in mass transport resistance. In this study, the chronology of morphological changes in the cathode catalyst layer due to carbon corrosion was identified and correlated with electrochemical performance degradation. PEFCs were subjected to the Department of Energy carbon corrosion accelerated stress test (AST) protocol. The study revealed two phases: in the initial phase (~500 AST cycles), amorphous carbon in contact with Pt nanoparticles oxidized fast. Rapid carbon loss and catalyst layer thinning occurred, but pore structure did not change significantly. Pt nanoparticles detached from the support and ECSA decreased drastically. In the second phase (~1500 AST cycles), carbon corrosion slowed down, but severe pore structure collapse was observed. Porosity and pore connectivity within the cathode catalyst layer decreased considerably. Electrochemical diagnostics corroborated this finding by showing significantly higher O2 mass transport resistance. Lastly, no significant change was observed in the concentration of oxides on the carbon surface after AST. But overall water management in the cathode catalyst layer deteriorated as the pore structure collapsed. This study provides an in-depth understanding of morphological changes during PEFC carbon corrosion AST protocol and motivates novel material design strategies to enable durable PEFCs.

catalyst layers↗

Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts

High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by the catalyst metal itself and its interactions with the carbon support. Several low-loaded PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. Overall, this is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration.

25 ENERGY STORAGE↗

Review—Development of Highly Active and Durable Hybrid Compressive Platinum Lattice Catalysts for Polymer Electrolyte Membrane Fuel Cells: Mathematical Modeling and Experimental Work

This review provides a comprehensive overview on the development of highly active and durable platinum catalysts with ultra-low Pt loadings for polymer electrolyte membrane fuel cells (PEMFCs) through a combined mathematical modeling and experimental work. First, simulation techniques were applied to evaluate the validity of the Tafel approximation for the calculation of the mass activity (MA) and specific activity (SA). A one-dimensional agglomeration model was developed and solved to understand the effects of exchange current density, porosity, agglomerate size, Nafion ® film thickness, and Pt loading on the MA and SA. High porosity (> 60%) and agglomerations at high Pt loadings cause the loss of the Tafel approximation and consequently the decrease in MA and SA. A new structure parameter was introduced to estimate the real porous structure using the fractal theory. The volumetric catalyst density was corrected by the fractal dimension (measured by Hg porosimetry), which gave a good agreement with the experimental values. The loading-dependent Tafel equation was then derived, which contains both the utilization and the non-linear scaling factor. Second, activated carbon composite support (ACCS) with optimized surface area, porosity, pore size, and pore size distribution was developed. The hydrophilic/hydrophobic ratio, structural properties (amorphous/crystalline ratio), and the number of active sites were optimized through metal-catalyzed pyrolysis. Stability of ACCS and Pt/ACCS were evaluated using an accelerated stress test (AST). The results indicated that Pt/ACCS showed no significant loss of MA and power density after 5,000 cycles at 1.0–1.5 V, while the commercial Pt/C catalysts showed drastic losses of MA and power density. Finally, monolayers of compressed Pt (core–shell-type Pt 3 Co 1 ) catalysts were structured by diffusing Co atoms (previously embedded in ACCS) into Pt. Compressive Pt lattice (Pt * ) catalysts were synthesized through an annealing procedure developed at the University of South Carolina (USC). The Pt * /ACCS catalyst showed high initial power density (rated) of 0.174 g Pt kW −1 and high stability (24 mV loss) at 0.8 A cm −2 after 30,000 cycles (0.6–1.0 V). The outstanding performance of Pt * /ACCS is due to the synergistic effect of ACCS and compressive Pt * lattice.

25 ENERGY STORAGE↗

Stability of Atomically Dispersed Fe–N–C ORR Catalyst in Polymer Electrolyte Fuel Cell Environment

We have investigated the durability of a platinum group metal (PGM-)free Fe–N–C catalyst in which the Fe sites are atomically dispersed (AD), and found it to be quite stable in standard accelerated stress test (AST) cycles normally used for low-PGM catalysts: a square wave with 0.6 V lower potential limit (LPL)—0.95 V upper potential limit (UPL) with 3-s holds at UPL and LPL in H 2 /N 2 , at 1.5 atm, 80 °C and 100% RH. Considering the metrics normally employed to characterize the durability of the low-PGM catalysts after 30,000 AST cycles, this PGM-free catalyst lost <50% catalyst activity, <50% H 2 /air performance at 0.8 V, and 40 mV at 1.5 A cm -2 . However, it is less stable in H 2 /air, losing ~50% catalyst activity after just 7.5 h of polarization measurements (load cycles). In combined cycles, the majority of the loss in catalyst activity occurred during the load cycles in H 2 /air rather than AST cycles in H 2 /N 2 . We have concluded that, unlike low-PGM catalysts that lose electrochemically active surface area (ECSA) through potential cycling-induced processes, (AD)Fe–N–C catalysts degrade by processes associated with the presence of oxygen.

25 ENERGY STORAGE↗

Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts

High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by not only the composition and morphology of the catalyst particle itself, but also its interactions with the carbon support. In this study several low-PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. This is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration. However porous supports also exhibit greater increases in transport resistance probably associated with enhanced Co leaching under the AST conditions.

25 ENERGY STORAGE↗

Mitigation of PtCo/C Cathode Catalyst Degradation via Control of Relative Humidity

Maintaining the high performance of proton-exchange membrane fuel cells (PEMFC) over the course of its lifetime is a key enabling factor for its successful commercialization as a primary power source in zero-emission transportation applications. In this context, it is important to mitigate the degradation of PtCo-alloy based cathode catalysts used for oxygen reduction reaction (ORR). PtCo-alloy catalysts exhibit high activity at beginning-of-life (BOL) which tends to decrease during operation due to loss of electrochemical surface area (ECSA) and dissolution-contamination related effects of the Co-alloying component. Here, we demonstrate the use of relative humidity (RH) of the inlet gases as a controllable parameter to mitigate the degradation of PtCo-alloy catalyst degradation. We employ a catalyst-specific voltage cycling accelerated stress test (AST) durability protocol as a function of inlet RH to degrade PtCo catalysts. A series of in situ electrochemical diagnostics and ex situ characterizations have been carried out to investigate the catalyst layer characteristics at end-of-test (EOT). Our results show that at sub-saturated conditions of durability protocol operation, PtCo catalyst sustains higher EOT H 2 /air performance due to better retention of ECSA and smaller impact of Co 2+ dissolution/contamination.

25 ENERGY STORAGE↗

Investigating the Particle Growth in Bimodal Pt/C Catalysts by In-Situ Small-Angle X-ray Scattering: Challenges in the Evaluation of Stress Test Protocol-Dependent Degradation Mechanisms

The influence of different combinations of accelerated stress test (AST) protocols simulating load-cycle and start/stop conditions of a proton exchange membrane fuel cell (PEMFC) vehicle is investigated on a bimodal Pt/C catalyst. The bimodal Pt/C catalyst, prepared by mixing two commercial catalysts, serves as a model system and consists of two distinguishable size populations. The change in mean particle size was investigated by in situ small-angle X-ray scattering (SAXS). The comparison to the reference catalysts, i.e., the two single-size population catalysts, uncovers the presence of electrochemical Ostwald ripening as a degradation mechanism in the bimodal catalyst. Increasing the harshness of the applied AST protocol combinations by faster changing between load-cycle or start/stop conditions, the particle size of the larger population of the bimodal catalyst increases faster than expected. Surprisingly, the change in mean particle size of the smaller size population indicates a smaller increase for harsher AST protocols, which might be explained by a substantial electrochemical Ostwald ripening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Baselining Activity and Stability of ORR Catalysts and Electrodes for Proton Exchange Membrane Fuel Cells for Heavy-Duty Applications

Activity and stability of electrodes with Pt and PtCo alloy catalysts supported on high surface area carbon, hereafter to as a-Pt/C and d-PtCo/C, were evaluated for heavy-duty applications. Both catalysts had nearly identical Pt loading (50-wt% Pt on carbon and 0.25 mg Pt cm −2 ) and had undergone thermal treatment to stabilize them by growing the average particle size to 4–5 nm. Both were subjected to 90,000 (90 k) standard accelerated stress tests (AST) cycles consisting of 0.6–0.95 V square wave potentials, 3-s hold at upper and lower potential limits in H 2 /N 2 at 1.5 atm, 80 °C and 100% RH. Test protocols were developed to monitor the performance losses and characterize them in terms of activity for the oxygen reduction reaction (ORR), oxygen transport in the electrode and proton transport in the membrane and cathode catalyst layer. Despite the nearly double initial ORR activity, the PtCo/C electrode degraded faster due to the leaching of Co from the catalyst that had started even before the imposition of the AST potential cycles. Commensurate with Co leaching, Co poisoning of ionomer is responsible for the inferior performance of d-PtCo/C electrode at high current densities both before and after AST.

30 DIRECT ENERGY CONVERSION↗

Performance and Durability of Heavy-Duty Fuel Cell Systems with an Advanced Ordered Intermetallic ORR Alloy Catalyst and Novel Support

Ordered PtCo intermetallic (OIM) catalyst (L1 0 -PtCo/C) is a promising candidate as the oxygen reduction reaction (ORR) catalyst in hybrid fuel cell systems (FCS) for class-8 heavy duty (HD) trucks. Compared to a baseline annealed Pt on high surface area carbon (a-Pt/HSC) catalyst, its mass activity (MA) is 71% higher initially and 144% higher after 90,000 potential cycles in an accelerated stress test (AST). Analysis of the AST data indicates that the ORR kinetic constants do not change with aging and the degradation in the OIM catalyst activity is linearly proportional to the loss in the electrochemically active surface area (ECSA). Several operational strategies are investigated to mitigate catalyst degradation and achieve 25,000-h electrode lifetime and 2.5 kW g −1 Pt utilization on a HD truck duty cycle including load sharing with the hybrid battery, regulating the radiator fan power to maintain the coolant temperature close to 60 °C, clipping the maximum cell voltage below 850 mV, limiting the ECSA loss to 55%, and oversizing the active area of the membrane electrode assemblies by 20%. Drive cycle simulations indicate that the lifetime average voltage degradation rate is about 1.8 μV h −1 and the integrated stack and FCS drive cycle efficiencies decrease by 3.5 to 3.9%.

25 ENERGY STORAGE↗

(Invited) Fuel Cell Component Durability for Million Mile Fuel Cell Trucks

While significant advances have been made and early commercial fuel cell light-duty vehicles (LDVs) are starting to be produced, fuel cells in the heavy-duty-vehicle (HDV) transportation sector (including trucks, long-haul semitrailers, maritime, trains, etc.) are nascent, despite the fact that advantages of fuel cells compared to both diesel and electric powertrains are very compelling in terms of emissions, charging time, efficiency, power-to-weight ratio, among others. However, the fuel-cell technology for HDVs requires a paradigm shift in fuel-cell research and development compared to LDVs, where the emphasis becomes efficiency and improvements in durability instead of a focus on increased power densities and lower cell costs. Heavy-duty applications require significantly longer vehicle lifetimes (>25,000 hours/1,000,000 miles for heavy-duty trucks), and therefore require improved fuel cell durability compared to light-duty vehicles. In 2020, HFTO formed the Million Mile Fuel Cell Truck Consortium (M2FCT) that includes a core team of five national laboratories to overcome durability and efficiency challenges in PEMFCs for heavy-duty applications with an initial focus on long-haul trucks. While targets and testing protocols have been developed for light-duty vehicles, the same level of targets and testing protocols have not been established for heavy-duty transportation. With operational times of greater than > 25,000 hours required, the need for well-developed accelerated stress tests (ASTs) is amplified. Results from these ASTs demonstrate the need for more durable electrode layers and well-controlled potential variations. Finally, this presentation will provide an overview of the DOE's Fuel Cell R&D approach, highlighting past and current activities, as well as strategies to enable fuel cell competiveness for heavy-duty applications.

25 ENERGY STORAGE↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗